Modelagem e controle de uma incubadora neonatalBRAGA JÚNIOR, Gilson Fernandes 08 August 2013 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2014-01-13T19:48:50Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ModelagemControleIncubadora.pdf: 2487143 bytes, checksum: d939f90346a45794889756c2631476cd (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2014-01-15T15:00:04Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ModelagemControleIncubadora.pdf: 2487143 bytes, checksum: d939f90346a45794889756c2631476cd (MD5) / Made available in DSpace on 2014-01-15T15:00:04Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ModelagemControleIncubadora.pdf: 2487143 bytes, checksum: d939f90346a45794889756c2631476cd (MD5)
Previous issue date: 2013 / Este trabalho apresenta uma introdução sobre a história da neonatologia, a conceituação e a modelagem matemática do sistema térmico de uma incubadora neonatal, contendo a relação da mesma com um recém-nascido quanto a trocas térmicas, a partir da primeira lei da termodinâmica. É apresentado o método que foi utilizado para a linearização (Séries de Taylor) e os pontos de operação calculados para o sistema linear obtido no formato de espaço de estados, e a partir deste foi obtida uma representação em função de transferência. A partir da modelagem matemática do sistema, foi realizado um teste em malha aberta para verificar as características do mesmo, como estabilidade, constante de tempo e convergência para um valor final desejado, e como o sistema real opera em malha fechada, foi também realizado um teste com o sistema nesta configuração contendo um ganho unitário de malha. O comportamento do sistema não linear foi comparado ao do sistema linearizado através de suas curvas de resposta temporal a uma entrada degrau para a verificação da validade da representação linear, e após a sua validação, diagramas de bode foram gerados para diferentes parâmetros do modelo, para observar-se o efeito desta variação no comportamento dinâmico da planta, e foi percebido que o comportamento do modelo não é alterado de forma substancial para a variação dentro das faixas verificadas. Um controlador proporcional e integral (PI) foi então projetado para a eliminação do erro de regime permanente presente resposta temporal do sistema.. Testes sob diversas condições de operação foram realizados no sistema linear assim como as curvas de variação de temperatura foram obtidas com o controlador aplicado no modelo não linear, sendo os resultados considerados satisfatórios para este tipo de aplicação. Este trabalho foi realizado com o auxílio da ferramenta computacional Simulink do software Matalb®. / This work presents an introduction about neonatology history, the concept and mathematical modeling of a neonatal incubator’s thermal system, with its thermal exchanges relations to an infant by the first law of thermodynamics. The method used for linearization (Taylor series) it is showed and the operation points calculated to the linear system obtained in the state space format, and then a representation in transfer function format. By the system’s mathematical modelling, an open loop test was done to verify the model behaviour, as characteristics of stability, time constant and convergence to a desired final value, and how the system operates at closed-loop, the system on this configuration was tested with the usage of an unitary gain. The behaviour of the non linear system was compared to the linearized system through their time response curves at a presence of a degree input to the verification of the linearized representation validity, and after the validation, bode diagrams were generated to different model parameters, to notice the effect of this variation on the model’s dynamic behaviour, and was observed that the model’s behaviour do not vary at a substantial form inside the verified ranges of values. A proportional and integral (PI) controller then was designed to eliminate the steady-state error present at the system’s time response. Tests under few operating conditions were done at the linear representation and the temperature variation curves were obtained with the controller applied to the non linear model, and the results were considered satisfactory to this kind of application. This work was made with the assistance of computational tool Simulink of the software Matlab®.
|
2 |
Projeto de um controlador Fuzzy Takagi-Sugeno para uma estação de tratamento de esgoto por lodos ativadosOLIVEIRA FILHO, José Haroldo Sena de 24 January 2013 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-03-07T15:37:09Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoControladorFuzzy.pdf: 1593015 bytes, checksum: 724013024cfa0539e49ad1f252cc7559 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-05-13T17:01:18Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoControladorFuzzy.pdf: 1593015 bytes, checksum: 724013024cfa0539e49ad1f252cc7559 (MD5) / Made available in DSpace on 2014-05-13T17:01:18Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoControladorFuzzy.pdf: 1593015 bytes, checksum: 724013024cfa0539e49ad1f252cc7559 (MD5)
Previous issue date: 2013 / Este trabalho propõe o projeto de um controlador Fuzzy do tipo Takagi-Sugeno em uma estação de tratamento de esgoto por lodos ativados. Este tipo de tratamento ocorre na presença de oxigênio, pois microorganismos aeróbios presentes no licor misto irão proporcionar a remoção tanto da matéria carbonácea quanto nutrientes formados por compostos à base de nitrogênio. O controlador atua via mecanismo de aeração e foi projetado para interpolar os ganhos proporcionais e integrativos de três controladores fixos locais que, por sua vez, foram projetados a partir da linearização de um modelo contínuo de balanço de massa de oxigênio. O controlador auxiliará manter a concentração de oxigênio dissolvido desejável na faixa de operação do processo para que ocorra a nitrificação, reação química de oxiredução que
transforma amônio em nitrito, que é fundamental para o sucesso do processo, e poderá também economizar energia elétrica utilizada pelo mecanismo de aeração. Os ensaios foram realizados via simulação computacional em quatro cenários idealizados comparando o desempenho do controlador fuzzy e o desempenho de um controlador fixo projetado em um ponto de operação diferente do qual se utilizou como valor de referência na planta. Ao aplicar
um degrau no valor de referência estabelecido no cenário de análise, observou-se o tempo de
subida, o tempo de acomodação e o erro em regime. Após os ensaios, observou-se que o
desempenho do controlador fuzzy nos quesitos tempo de subida e tempo de acomodação em
relação ao controlador fixo foi melhor, enquanto nos quesitos sobressinal e erro em regime foi
semelhante. Após as análises, concluiu-se que a estratégia de controle escolhida neste trabalho
é viável, pois de acordo com o valor auferido de oxigênio dissolvido na entrada da planta, o
controlador fuzzy irá interpolar os ganhos proporcionais e integrativos de um controlador fixo
projetado na vizinhança deste valor e assim, atuar de forma bastante satisfatória. / The mean goal of this work is the design of a Takagi-Sugeno fuzzy controller on an activated
sludge wastewater treatment plant. This kind of process requires oxygen and aerobic
microorganisms in the mixed liquor that are necessary to remove the carbonaceous matter and
the nutrients based on nitrogen compounds. The controller acts on the aeration valve engine
and has been designed to interpolate the proportional and integrative gain of three fixes
controllers designed from the linearization of a continuous model of oxygen mass balance.
The controller assists to keep the desirable dissolved oxygen concentration necessary to the
nitrification, an oxi-reduction chemical reaction that transforms ammonia into nitrite and it is
also possible to save electric energy used by the aeration engine. It is imperative the
nitrification occurs for the success of the whole process. The Assays were performed by
computerized simulation in four idealized scenarios analyzing the performances of the fuzzy
controller and the fix controller designed to a different operation point of the set point defined
in the plant. Applying a degree in the set point established in the scenario it was analyzed the
rise time, settling time, overshoot and steady-state error. After the assays, the fuzzy controller
performed better than the fix one at rise time and settling time criteria and equivalent
performance at overshoot and steady-state error. After analysis, it was conclude that the
control strategy chosen in the work is viable, according the dissolved oxygen measure at the
plant entrance, the fuzzy controller interpolate the proportional and integrative gains of a fix
controller designed near this value and thus act quite satisfactory.
|