• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistema automatizado com interface IEEE-488 para a calibração de instrumentos

Becerra Sablon, Vicente Idalberto 10 June 1998 (has links)
Orientador: Jose Geraldo Chiquito / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-23T18:52:24Z (GMT). No. of bitstreams: 1 BecerraSablon_VicenteIdalberto_M.pdf: 4478102 bytes, checksum: ee39559cd42262092802adfe3e13e840 (MD5) Previous issue date: 1998 / Resumo: Nesta dissertação apresentamos um sistema automatizado para a calibração de instrumentos com interface IEEE-488 (General Purpose Interface Bus, GPIB),desenvolvido no Laboratório de Calibração Elétrica (LACE) junto ao Departamento de Comunicações (DECOM) da UNICAMP. O sistema integra em uma única rede, instrumentos dos mais diversos fabricantes, tais como: Hewlett Packard, Tektronix, Fluke, National Instruments, Valhalla Scientific e outros. Para isso, é utilizado o cartão controlador PC-IIA da National Instruments, o qual, colocado dentro de um microcomputador IBM-PC, permite realizar o controle de toda a operação da rede, junto ao software desenvolvido chamado GPIBNet, que por sua vez padroniza a comunicação entre todos os instrumentos. Este sistema permite automatizar rotinas de aferição, calibração e teste, compatibilizando as especificações dos diferentes equipamentos. Com essa utilização, busca-se um aumento significativo da produtividade e principalmente da qualidade da medição, devido à minimização e compensação dos erros relativos ao sistema de medição e à apreciação humana. Além disso, possibilita-se a operação do sistema na máxima eficiência e facilita-se a geração da documentação (relatórios, certificados e tabelas ) / Abstract: In this work we present an automatized system for calibration of instruments with the IEEE-488 (General Purpose Interface Bus, GPIB) interface. This system was developed in the Electrical Calibration Laboratory (LACE) together with the collaboration of Department of the Communications (DECOM) of the UNICAMP. The system can integrates the instruments of different rands, such as: Hewlett Packard, Tektronix, Fluke, National Instruments, Valhalla Scientific and others, in a single network interconnected under the interface provided by the controller card of National Instruments PC-IIA put into an IBM-PC microcomputer. For the control of all operations of the network, it was developed a software called GPIBNet, which standardizes the communication of all connected instruments. This system permits the automation of the routines of measurement, calibration and test, making compatible the specifications of different equipment. By using this system, we can get a significant increase in the productivity and, mainly, in the measurement quality, due to the minimization and compensation of the relative errors of the measurement system and the human appreciation. Moreover it permits a maximum efficiency operation of the system and facilitates the documentation generation (reports, certificates and tables) / Mestrado / Eletronica e Comunicações / Mestre em Engenharia Elétrica
2

Sistema automático para caracterização de sensores a fibra óptica para alta tensão / Characterization system for fiber optics based sensors for high-voltage

Spengler, Anderson Wedderhoff, 1986- 16 August 2018 (has links)
Orientador: Elnatan Chagas Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-16T09:48:26Z (GMT). No. of bitstreams: 1 Spengler_AndersonWedderhoff_M.pdf: 5622371 bytes, checksum: dd49f965749d4c55fa19542a3a801d9c (MD5) Previous issue date: 2010 / Resumo: Esta dissertação aborda o projeto de um sistema de caracterização de sensores baseados em fibras ópticas para alta-tensão. O sistema é formado por dois módulos principais, um relacionado com a câmara térmica e outro relativo à alta-tensão. O desenvolvimento do sistema deve-se basicamente às necessidades de personalização e precisão para a caracterização dos sensores e outras aplicações. A câmara climática tem seu projeto eletrônico e mecânico descritos, com ênfase na utilização de módulos termoelétricos, nos controladores proporcional-integral-derivativos utilizados e os parâmetros de sintonia encontrados. Foi feito o estudo da configuração que utiliza dois módulos termoelétricos em série, apontando as vantagens e desvantagens desta configuração. A faixa de temperatura para a câmara obtida é de 0 ºC até 70 ºC, com erro ±0,1 ºC semelhantes às câmaras climáticas comerciais. Há a proposta de um circuito gerador e analisador de ondas arbitrárias de alta-tensão, e ensaios com um sistema semelhante ao proposto para tensões de até 15 kV, para validação do método de eliminação de harmônicas proposto nesta dissertação, obtendo resultados de THD da ordem de 0,04%, valor este limitado pela definição do analisador de sinais / Abstract: This work discusses the project of a characterization system fiber optics based sensors for high-voltage. The system consists of two main modules, one related to the thermal chamber and another on high-voltage part. The system development was mainly due to the needs of customization and precision for the characterization of sensors and other applications. The thermal chamber has its electronic and mechanical design described, with emphasis on the use of thermoelectric modules, the proportional-integral-derivative controllers and their tuning parameters. A study was conducted on the configuration that uses two thermoelectric modules in series, showing the advantages and disadvantages of this configuration. The obtained temperature range for the chamber was 0°C to 70 °C with ± 0.1 °C error, similar to the commercial chambers. There is a proposal for a circuit for arbitrary high voltage wave generator and analyzer, and tests with one system similar to that proposed for voltages up to 15kV, to validate a harmonics eliminator method, obtaining results of THD about 0.04% which is limited by the definition of signal analyzer / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
3

Secagem de uvas Niágara visando obter subsídios para o processamento, supervisão e controle / Drying of Niagara grapes in order to obtain the processing subsidies, supervision and control

Santiago, Wesley Esdrar, 1987- 02 July 2012 (has links)
Orientadores: Bárbara Janet Teruel Mederos, Rafael Augustus de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-20T14:26:52Z (GMT). No. of bitstreams: 1 Santiago_WesleyEsdrar_M.pdf: 1768290 bytes, checksum: 65444ac5fe9ceb573586c9f40d5e1894 (MD5) Previous issue date: 2012 / Resumo: Tradicionalmente utilizada em alguns países vinícolas e com pouca ou nenhuma aplicação no Brasil, a secagem de uvas destinadas a vinificação representa uma importante metodologia para obtenção de vinhos de mesa com elevado nível de qualidade, no entanto até o presente momento diversos problemas oriundos da falta de controle das condições ambientais da secagem destes produtos tem impedido a quantificação e obtenção de um desempenho razoável para tal procedimento. Nesta pesquisa foi desenvolvido um sistema de monitoramento da perda de massa através de um sensor extensométrico e implementado um aplicativo computacional de monitoramento e aquisição de dados do processo de secagem. O objetivo do estudo foi analisar o efeito de cinco níveis de temperatura e de vazão de ar na perda de massa e na qualidade físico química de uvas Niágara rosada a fim de determinar as melhores condições e parâmetros de secagem para os efeitos causados no processo e na qualidade físico-química das uvas. Um planejamento composto central com cinco níveis de variação foi utilizado para determinar as influências dos fatores (temperatura e vazão de ar) nas respostas (Concentração de Sólidos Solúveis, Acidez Total Titulável, concentração de polifenóis, pH, taxa e tempo de secagem). Obteve-se como resultado aumento médio de 2,9 pontos na concentração de sólidos solúveis, sendo o mínimo de 16,1 e o máximo de 23 ºBrix, e aumento médio de 265,1 pontos na concentração de polifenóis, mínimo de 940 e máximo de 1359 mg de ácido gálico para cada 100 gramas de suco, a acidez total titulável apresentou baixa variação entre antes e o depois, tendo maior redução nos ensaios com maior temperatura, comprovando os efeitos positivos da secagem e principalmente quando realizada em condição controlada. O grau das respostas para os diferentes níveis de tratamento não interferiram nas mudanças ocorridas nos parâmetros físico-químicos, porém apenas a concentração de polifenóis teve influência linear e quadrática da temperatura e vazão de ar. A secagem até o nível estabelecido de 12% de perda de massa ocorre no período de taxa constante, caracterizando-a como um processo sem dinâmica, resultante em modelos matemáticos de primeira ordem altamente capazes de representar as variações que ocorrem no processo real. O sistema de pesagem em tempo real desenvolvido mostrou-se adequado para medição da perda de massa de uvas durante a secagem, tanto em alta como em baixa temperatura, sendo uma ferramenta de grande utilidade para a obtenção dos parâmetros necessários para a construção de modelos matemáticos de processos de secagem, além de fornecer subsídios durante a análise do processo e tomada de decisão / Abstract: Traditionally used in wineries and in some countries with little or no application in Brazil, the drying of grapes for wine making is an important methodology for obtaining wines with high quality, yet so far various problems of lack of control of environmental conditions in the drying of these products has prevented the quantification and obtainment of a reasonable performance for such procedure. In this research was developed a system to monitor mass loss through an extensometer sensor and implementing a computer application for monitoring and data acquisition in the drying process. The objective of this study was to analyze the effect of five temperature levels and air flow in the mass loss and qualities physico and chemical from Niagara grapes to determine the best conditions and parameters in the drying for the effects caused during the process and physical chemical quality of the grapes. A central compost planning with five levels of variance was used to determine the influences of the factors (temperature and air flow) in the responses (Concentration of Soluble Solids, Titratable Acidity, Polyphenols Concentration, pH, rate and drying time). It was obtained as a result an average increasing of 2.9 points in the concentration of soluble solids, being the 16,1 minimum and 23 ºBrix maximum, and an average increase of 265.1 points in the concentration of polyphenols, minimum 940 and maximum 1359 mg of gallic acid per 100 grams of juice, the total acidity titratable presented low variation between before and after, having a bigger reduction in the examples with higher temperature, proving the positive effects of the drying and mainly when performed in controlled conditions. The variation of the responses for different levels of treatment did not interfere in the changes that happen, but only the concentration of polyphenols had linear and quadratic influence from temperature and air flow. The drying until the established level of 12% weight loss occurs in the period of constant rate, characterizing it as a process without dynamic, resulting in first order mathematical models of high capacity to represent the variations that happen in the real process. The weighing system developed in real time demonstrated to be adequate for measuring of mass loss during the drying of grapes, as in high as in low temperature, being a very useful tool to obtain the necessary parameters for the construction of mathematical models in the process of drying, besides providing subsidies during the process analysis and decision making / Mestrado / Maquinas Agricolas / Mestre em Engenharia Agrícola

Page generated in 0.0917 seconds