Construction and Evaluation of a Controlled Active Mass (CAM) : A new cooling system design for increased thermal comfort using low exergy sources

Ghahremanian, Shahriar, Janbakhsh, Setareh January 2007 (has links)
<p>Nowadays, office buildings often have large temperature variations during the day and building envelope acts as an energy storing mass and damp these effects and so Offices need more cooling because of internal heat sources. But we know that cooling is more expensive than heating and it uses the very good quality of energy sources (exergy). Controlled Active Mass (CAM) is new approach to absorb radiant heating and acts as a passive cooling device. It has direct cooling effect and reduces the peak load. CAM is a new cooling system design with applying the low energy sources and operates at water temperature close to room temperature and increase the efficiency of heat pumps and other systems.</p><p>In this project, we calculated the transient heat transfer analysis for CAM in a very well insulated test room with façade wall, Internal heat generators (such as Manikin, Computer simulator & lighting) and ventilation.</p><p>Then Polished (shiny) CAM constructed from Aluminum sheets with 0.003 m thickness. It is cube shape with 0.6 m length. This size of CAM is according to 2.5 times larger than human body volume and initial water temperature assumed near half of human body temperature. Then in order to more radiation damping (absorption) by CAM, it painted black (also based on color analysis in heat transfer calculation).</p><p>Some velocity and temperature measurement have been carried out on both polished CAM and black CAM, after visualization by smoke and Infrared Camera. And more cases tested to see the effect of façade wall, IHG’s and ventilation inlet temperature. Thermal comfort measurement also have been done for finding PMV, PPD and temperature equivalent for a seated person which is doing an office job with normal closing.</p><p>At the end results discussed which includes the effect of CAM in room, differences between polished CAM and black CAM and effect of main heat sources on both CAM types (Polished / Black).</p>
2

Construction and Evaluation of a Controlled Active Mass (CAM) : A new cooling system design for increased thermal comfort using low exergy sources

Ghahremanian, Shahriar, Janbakhsh, Setareh January 2007 (has links)
Nowadays, office buildings often have large temperature variations during the day and building envelope acts as an energy storing mass and damp these effects and so Offices need more cooling because of internal heat sources. But we know that cooling is more expensive than heating and it uses the very good quality of energy sources (exergy). Controlled Active Mass (CAM) is new approach to absorb radiant heating and acts as a passive cooling device. It has direct cooling effect and reduces the peak load. CAM is a new cooling system design with applying the low energy sources and operates at water temperature close to room temperature and increase the efficiency of heat pumps and other systems. In this project, we calculated the transient heat transfer analysis for CAM in a very well insulated test room with façade wall, Internal heat generators (such as Manikin, Computer simulator &amp; lighting) and ventilation. Then Polished (shiny) CAM constructed from Aluminum sheets with 0.003 m thickness. It is cube shape with 0.6 m length. This size of CAM is according to 2.5 times larger than human body volume and initial water temperature assumed near half of human body temperature. Then in order to more radiation damping (absorption) by CAM, it painted black (also based on color analysis in heat transfer calculation). Some velocity and temperature measurement have been carried out on both polished CAM and black CAM, after visualization by smoke and Infrared Camera. And more cases tested to see the effect of façade wall, IHG’s and ventilation inlet temperature. Thermal comfort measurement also have been done for finding PMV, PPD and temperature equivalent for a seated person which is doing an office job with normal closing. At the end results discussed which includes the effect of CAM in room, differences between polished CAM and black CAM and effect of main heat sources on both CAM types (Polished / Black).