• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Classificadores neurais aplicados na detecção de curto-circuito entre espiras estatóricas em motores de indução trifásicos acionados por conversores de frequência / Neural classifier aplied in stator winding inter-turn short circuit in three-phase induction motors driven by frequency converter

Oliveira, Átila Girão de 23 May 2014 (has links)
OLIVEIRA, A. G. Classificadores neurais aplicados na detecção de curto-circuito entre espiras estatóricas em motores de indução trifásicos acionados por conversores de frequência. 2014. 98 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-02-19T18:03:47Z No. of bitstreams: 1 2014_dis_agoliveira.pdf: 2374651 bytes, checksum: d0b7882e7849cec13f6935188050661d (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-02-20T11:17:25Z (GMT) No. of bitstreams: 1 2014_dis_agoliveira.pdf: 2374651 bytes, checksum: d0b7882e7849cec13f6935188050661d (MD5) / Made available in DSpace on 2015-02-20T11:17:25Z (GMT). No. of bitstreams: 1 2014_dis_agoliveira.pdf: 2374651 bytes, checksum: d0b7882e7849cec13f6935188050661d (MD5) Previous issue date: 2014-05-23 / This dissertation reports applications of artificial neural networks to detect stator winding interturn fault of three phase induction motor drived by frequency inverter. The artificial neural networks, like Simple and Multilayer Perceptron, served as off-line classifiers to short-circuit fault condition or healthy condition. In the training of Multilayer Perceptron, two different algorithms are used: the error back-propagation, which is a classic algorithm, and the extreme learning machine, as a relative new alternative for the classic back-propagation. The new one is more worthwhile because of its implementation easiness and higher speed of computation. The database used on the training and validation of the networks is created from an experimental setting, therefore it is composed by true data. The attributes used as failures’ indicators are selected from certain frequencies of the spectrum, based on some theories of current signature analysis. In the second instance, the technique of principal components analysis is employed. The results obtained for the designed classifiers are shown, and some considerations are made on their use in real time embedded applications, which is the most important projection for future researches. / Este trabalho deriva da aplicação de redes neurais artificiais para a detecção de curto-circuito entre espiras em motor de indução trifásico, acionado por inversor de frequência. As redes neurais artificiais, do tipo Perceptron Simples e Multicamadas, são usadas para detectar falhas de curto-circuito no bobinamento estatórico de motores de indução trifásicos de forma off-line. Para treinamento do Perceptron Multicamadas são usados dois algoritmos distintos: o error back-propagation, que figura como o algoritmo clássico na literatura especializada, e o extreme learning machine, que é uma alternativa, relativamente recente, ao algoritmo clássico. Este algoritmo é uma opção atraente para o desenvolvimento rápido de classificadores. O banco de dados usado para treinamento e validação das redes é obtido a partir de experimentação laboratorial, portanto composto de dados reais. Os atributos utilizados para a detecção da falha são componentes de frequência do espectro harmônico da corrente estatórica do motor. O critério de escolha destas componentes, a priori, é fundamentado em resultados de investigações prévias da assinatura de corrente e, em segunda instância, é aplicada a técnica de análise de componentes principais. São apresentados os resultados obtidospelos classificadores projetados, e feitas algumas considerações quanto à utilização destes em aplicação embarcada e em tempo real, que é a principal projeção de futuros trabalhos a partir do atual.
2

Conversor CA-CC trifásico de único estágio, bidirecional, isolado em alta frequência, com correção de fator de potência / A bidirectional single-stage three-phase rectifier with high-frequency isolation and power factor correction

Almeida, Bruno Ricardo de 27 October 2016 (has links)
ALMEIDA, B. R. Conversor CA-CC trifásico de único estágio, bidirecional, isolado em alta frequência, com correção de fator de potência. 2016. 191 f. Tese (Doutorado em Engenharia Elétrica)-Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2017-06-12T13:47:55Z No. of bitstreams: 1 2016_tese_bralmeida.pdf: 7030749 bytes, checksum: cb34090f1dd1d01c4b23b8dce5ea6936 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2017-06-12T13:56:15Z (GMT) No. of bitstreams: 1 2016_tese_bralmeida.pdf: 7030749 bytes, checksum: cb34090f1dd1d01c4b23b8dce5ea6936 (MD5) / Made available in DSpace on 2017-06-12T13:56:15Z (GMT). No. of bitstreams: 1 2016_tese_bralmeida.pdf: 7030749 bytes, checksum: cb34090f1dd1d01c4b23b8dce5ea6936 (MD5) Previous issue date: 2016-10-27 / This work proposes the study and implementation of a single-stage three-phase bidirectional ac-dc converter with high-frequency isolation and power factor correction. Based on the dual active bridge (DAB) converter associated with the three-state switching cell (3SSC), it is possible to state that this topology is adequate for telecom power supply applications operating at 380 V-400 V. Another interesting application for the proposed approach lies in novel concepts involving distributed generation and smart grids, since this converter is able to connect the three-phase grid to other sources/loads and control power flow among them. A theoretical analysis is carried out based on the fundamental model, where it is shown that the voltage across the H-bridge is nearly that obtained with AM-DSB (Amplitude Modulation with Double Side-Band) technique. Thus, the analysis of losses is performed while the limits for the semiconductors operating under soft switching condition are established. A design example is developed, while all hardware is described and software is implemented in a 32-bit microcontroller by Texas Instruments. Simulation and experimental results are properly discussed, validating the proposed converter operation in terms of steady-state condition and transient response when submitted to load steps. / Este trabalho propõe o estudo e implementação de um conversor CA-CC bidirecional trifásico de único estágio, isolado em alta frequência com correção de fator de potência. Baseado no conversor dual active bridge (DAB) e associado com a célula de comutação de três estados (CC3E), pode-se afirmar que esta topologia é adequada para aplicações como fontes de telecomunicação operando em 380 V - 400 V. Outra aplicação interessante para a topologia proposta reside nas novas concepções de geração distribuída e smart grids, pois esse conversor pode conectar a rede elétrica trifásica a outras fontes/cargas e controlar o fluxo de potência entre as mesmas. Uma análise matemática baseada no modelo fundamental é apresentada, na qual se verifica que a tensão efetiva aplicada na ponte H se aproxima daquela obtida com a técnica AM-DSB (Amplitude Modulation with Double Side-Band – Modulação em Amplitude com Banda Lateral Dupla). Dessa forma, desenvolve-se a análise de perdas e são delimitadas as faixas de comutação não dissipativa para os semicondutores. Um exemplo de projeto é desenvolvido, sendo descrito todo o hardware executado e o software implementado em um microcontrolador de 32 bits fabricado por Texas Instruments. Resultados de simulação e experimentais são adequadamente discutidos, validando o funcionamento do conversor proposto tanto em regime permanente quanto no que tange à resposta transitória diante de degraus de carga.
3

Conversor Boost ZCZVT aplicado em um sistema de iluminação de emergência com LED

Amaral, Heberty Huilton January 2011 (has links)
Fundação Araucária / Neste trabalho foi realizado um estudo sobre um sistema de iluminação de emergência não permanente. Este sistema é constituído de baterias, conversor boost e o LED de potência. O foco do trabalho é analisar o conversor boost, que emprega duas técnicas de comutação, sendo elas: comutação dissipativa e comutação suave. As análises feitas no conversor são referentes a comutação da chave semicondutora principal ocorrer de forma dissipativa ou suave para a técnica de comutação dissipativa e verificar se para a comutação suave as chaves semicondutoras (principal e auxiliar) comutam de forma dissipativa ou suave. Outro fato importante é avaliar o rendimento do conversor boost para as duas técnicas de comutação. Ainda é averiguada a autonomia do sistema de iluminação de emergência e também se ele está em conformidade com que cita a norma IEEE 446, referente a autonomia do sistema. Por fim é apresentada as formas de onda da corrente fornecida ao LED. Em suma, o conversor que emprega a técnica de comutação dissipativa demonstrou que a comutação ocorre de forma dissipativa, já para a técnica de comutação suave, a comutação transcorreu de forma suave. A eficiência do conversor mensurada através da autonomia do sistema de iluminação de emergência comprovou que a comutação suave apresenta maior eficiência do que a comutação dissipativa, em torno de 34%, devido a redução das perdas no chaveamento. Foi relatado que o conversor com a técnica de comutação suave empregado no sistema de iluminação de emergência obteve uma autonomia de uma hora e quatro minutos, já o conversor que utiliza a técnica de comutação dissipativa obteve uma autonomia de quarenta e dois minutos. Portanto, os sistemas de iluminação de emergência, no qual o conversor boost faz uso das duas técnicas de comutação estão em conformidade com a norma IEEE- Std 446. Em análise última observou-se que a corrente fornecida ao LED proveniente de um conversor com comutação suave possui uma ondulação em torno de 35% menor que a corrente oriunda de um conversor com comutação dissipativa e, ainda não possui oscilação do nível de corrente, tais características elevam a vida útil do LED e não alteram as características fotométricas do LED. / In this paper we present a study of an emergency lighting system is not permanent. This system consists of batteries, LED boost converter and power. The focus of the paper is to analyze the boost converter, which employs two switching techniques, which are: hard switching and soft switching. The analysis made in the converter are related to the commutation of the main semiconductor switch occur hard or soft switching technique for hard and check for soft switching the switches (main and auxiliary) switch in a hard or soft. Another important fact is to evaluate the performance of the boost converter for the two switching techniques. Also investigated is the autonomy of the emergency lighting system and also if he is quoting in accordance with IEEE 446, regarding the autonomy of the system. Finally is shown the waveform of the current supplied to the LED. In short, the converter that employs the technique of switched hard demonstrated that switching occurs in a hard, since the techniques of soft switching, the switch went soft. The measured efficiency of the converter through the autonomy of the emergency lighting system has proven that soft switching is more efficient than the hard switching, around 34% due to reduction in switching losses. It was reported that the converter with soft switching technique used in emergency lighting system achieved an endurance of one hour and four minutes, as the converter using the switching technique obtained a hard range of forty-two minutes. Therefore, emergency lighting systems, in which the boost converter makes use of two switching techniques are in accordance with IEEE Std-446. In ultimate analysis it was observed that the current supplied to the LED from a converter with soft switching has a ripple around 35% lower than the current coming from a switching converter with hard and does not have oscillation current level, such features increase the lifetime of the LED and do not alter the photometric characteristics of the LED.

Page generated in 0.1073 seconds