• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 3
  • 2
  • 1
  • Tagged with
  • 13
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo experimental de consolos de concreto com fibras moldados em etapas distintas dos pilares / Experimental research of reinforced fiber concrete corbels shaped in distinct stage to the column

Costa, Jônatas Barreto de Andrade 15 May 2009 (has links)
A produção industrial do consolo tradicional apresenta dificuldades devido à grande quantidade de armadura em um espaço pequeno. Além da armadura do tirante principal, normalmente se utilizam estribos verticais e horizontais. O presente estudo experimental propõe um consolo moldado em etapa anterior à do pilar, com a armadura e superfícies preparadas para a ligação posterior com o pilar, durante a concretagem deste elemento. O consolo dispõe somente da armadura do tirante principal e de fibras metálicas incorporadas à matriz de concreto, sem estribos verticais ou horizontais. Em alguns modelos foi utilizado um tipo de armadura de costura alternativo. As principais variáveis analisadas foram a taxa de armadura e o arranjo das barras dos tirantes. A adição de fibras ao consolo reduziu a fissuração na biela de compressão e aumentou a resistência à ruptura dos consolos em 8%, apresentando boa ductilidade, mesmo depois da máxima solicitação. Com o aumento da armadura do tirante no consolo com fibras, a resistência à ruptura foi 69% maior. Considerando o patamar de solicitação de serviço do consolo tradicional, os modelos moldados em etapas distintas apresentaram aberturas de fissuras na interface consolo-pilar 33% maiores, apesar de demorarem mais a aparecer. Entretanto, quando aumentada a taxa de armadura principal, os modelos moldados em etapas distintas demonstraram fissuras 23% menores que o consolo tradicional. / The industrial production of traditional corbel presents some difficulties due to the great quantity of reinforcement in a small space. Beyond the main bars, it is generally used vertical and horizontal stirrups. This experimental study proposes a corbel shaped in the prior stage to the column, with the reinforcement and surfaces prepared to the later connection with the column during the molding of it. The corbel has only the reinforcement of main bars and steel fibers incorporated to the concrete matrix, without vertical or horizontal stirrups. In some models were used a kind of alternative secondary reinforcement. The main variables analyzed were the reinforcement rate and the arrangement of the main bars. The addition of fibers to the corbel reduced the crack in the compressed diagonal and increased the resistance to rupture of corbels in 8%, presenting a reasonable ductility even after the maximum load. With the increase of reinforcement of main bars in the corbel with fibers, the resistance to rupture was 69% greater. Considering the baseline of service load of traditional corbel, models shaped in distinct stages presented crack openings 33% larger, in spite of taking a longer time to show up. However, when the rate of primary reinforcement was increased, the models shaped in distinct stages had cracks 23% smaller than the traditional corbel.
2

Estudo experimental de consolos de concreto com fibras moldados em etapas distintas dos pilares / Experimental research of reinforced fiber concrete corbels shaped in distinct stage to the column

Jônatas Barreto de Andrade Costa 15 May 2009 (has links)
A produção industrial do consolo tradicional apresenta dificuldades devido à grande quantidade de armadura em um espaço pequeno. Além da armadura do tirante principal, normalmente se utilizam estribos verticais e horizontais. O presente estudo experimental propõe um consolo moldado em etapa anterior à do pilar, com a armadura e superfícies preparadas para a ligação posterior com o pilar, durante a concretagem deste elemento. O consolo dispõe somente da armadura do tirante principal e de fibras metálicas incorporadas à matriz de concreto, sem estribos verticais ou horizontais. Em alguns modelos foi utilizado um tipo de armadura de costura alternativo. As principais variáveis analisadas foram a taxa de armadura e o arranjo das barras dos tirantes. A adição de fibras ao consolo reduziu a fissuração na biela de compressão e aumentou a resistência à ruptura dos consolos em 8%, apresentando boa ductilidade, mesmo depois da máxima solicitação. Com o aumento da armadura do tirante no consolo com fibras, a resistência à ruptura foi 69% maior. Considerando o patamar de solicitação de serviço do consolo tradicional, os modelos moldados em etapas distintas apresentaram aberturas de fissuras na interface consolo-pilar 33% maiores, apesar de demorarem mais a aparecer. Entretanto, quando aumentada a taxa de armadura principal, os modelos moldados em etapas distintas demonstraram fissuras 23% menores que o consolo tradicional. / The industrial production of traditional corbel presents some difficulties due to the great quantity of reinforcement in a small space. Beyond the main bars, it is generally used vertical and horizontal stirrups. This experimental study proposes a corbel shaped in the prior stage to the column, with the reinforcement and surfaces prepared to the later connection with the column during the molding of it. The corbel has only the reinforcement of main bars and steel fibers incorporated to the concrete matrix, without vertical or horizontal stirrups. In some models were used a kind of alternative secondary reinforcement. The main variables analyzed were the reinforcement rate and the arrangement of the main bars. The addition of fibers to the corbel reduced the crack in the compressed diagonal and increased the resistance to rupture of corbels in 8%, presenting a reasonable ductility even after the maximum load. With the increase of reinforcement of main bars in the corbel with fibers, the resistance to rupture was 69% greater. Considering the baseline of service load of traditional corbel, models shaped in distinct stages presented crack openings 33% larger, in spite of taking a longer time to show up. However, when the rate of primary reinforcement was increased, the models shaped in distinct stages had cracks 23% smaller than the traditional corbel.
3

Refuge in Belen Valley

Arias-Caballero, Diego Andres 17 June 2013 (has links)
A story about love and desire to imagine architecture in a peruvian landscape. On one hand, 'Refuge in Belen Valley' is a thesis about discovering the ideal conditions that architecture should meet in a landscape, conditions that approach the idea of an offering of man rather than a conditioning for man. On the other, it is a thesis about thinking architecture as a composition derived out of material properties, emotional intentions, inhabiting possibilities and counterpoint, the arrangement of differences through dialogue. / Master of Architecture
4

Consolos de concreto moldados em duas etapas: influência do tratamento da interface e da adição de fibras de aço / Concrete corbels cast in two stages: influence of treatment of the interface and the addition of steel fibers

Oliveira, Edilene Muniz de 29 August 2012 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-08-26T21:44:47Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação Final_Edilene Muniz.pdf: 17487028 bytes, checksum: 2a254821cacd0301c5e968351a019420 (MD5) / Made available in DSpace on 2014-08-26T21:44:47Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação Final_Edilene Muniz.pdf: 17487028 bytes, checksum: 2a254821cacd0301c5e968351a019420 (MD5) Previous issue date: 2012-08-29 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Concrete corbels are among the most used components to connect precast elements. Series production is often prejudiced by the necessity of making corbels in different positions in precast elements. To reduce this obstacle and rationalize the production, execution of concrete corbels cast in two stages can be a good alternative. The researche reported here intended to evaluate different procedures of making concrete corbels cast in two stages, being column cast firstly and, after removing formwork, corbels can be cast. Concrete corbels with and without steel fibers, both with horizontal stirrups and with steel fibers replacing it, with varying the treatment of joint and the shape of the connect the main steel bars to the column were analyzed. To do so, experimental and analytical analyses of concrete corbels cast monolithically and in two distinct phases were carried out. In the tests, the strength, vertical and horizontal displacements in relation to the column, the opening of cracks and strains of main steel and horizontal stirrups were determined. From these tests it was observed that the ultimate strength of monolithic corbels increased significantly when steel fibers were added to concrete, even when they replaced the horizontal stirrups, but this increase did not occur in concrete corbels cast in two stages. However, it was observed that steel fibers could replace the horizontal stirrups without damage to the bearing capacity. Besides, the presence of horizontal stirrups increased the ultimate strength of the concrete corbels without steel fibers cast in two stages. It was also observed that the opening of the joint between the corbel and the column was also influenced by the presence of horizontal stirrups for concrete corbels cast in two stages and monolithic concrete corbels. In the other hand, steel fibers added to the concrete did not affect the opening of the joint corbel-column of corbel cast in two stages, but substantially reduced this opening in monolithic corbels. Finally, it was observed that the treatment of the interface had little significance in the ultimate strength of the concrete corbels cast in two stages, but it influenced the opening of this interface, although only in concrete corbels with horizontal stirrups. / Os consolos de concreto estão entre os componentes das ligações mais utilizados entre os elementos pré-moldados. A produção em série é muitas vezes prejudicada pela necessidade da confecção de consolos em diferentes posições nas peças pré-moldadas. Visando reduzir esse entrave, otimizando a produção, a execução de consolos de concreto moldados em duas etapas pode ser uma boa alternativa. Essa pesquisa intencionou avaliar diferentes procedimentos de confecção de consolos de concreto moldados em duas etapas, onde molda-se primeiramente o pilar e após a desfôrma, moldam-se os consolos. Foram analisados consolos com e sem a incorporação de fibras metálicas, tanto com armadura de costura como em substituição a ela, variando o tratamento da junta e a forma da ligação do tirante do consolo ao pilar. Para tanto, foram realizadas análises experimental e analítica de consolos moldados monoliticamente e em fases distintas. Nos ensaios, foram determinadas a força, o deslocamento vertical e horizontal do consolo em relação ao pilar, a abertura de fissuras e as deformações da armadura do tirante e armadura de costura. A força última dos consolos monolíticos aumentou significativamente quando foi incorporado fibras metálicas ao concreto, inclusive quando estas foram em substituição da armadura de costura. Já nos consolos moldados em duas etapas não ocorreu esse aumento, no entanto, observou-se que as fibras metálicas poderiam substituir a armadura de costura sem prejuízo à capacidade resistente. A presença da armadura de costura elevou a força última dos consolos de concreto sem fibras, moldados em duas etapas. A abertura na interface entre o consolo e o pilar também é influenciada pela presença da armadura de costura, tanto nos consolos moldados em duas etapas quanto nos consolos monolíticos. Já as fibras metálicas adicionadas ao concreto não influenciaram a abertura da interface consolo-pilar dos consolos moldados em duas etapas, mas reduziram substancialmente nos consolos monolíticos. O tratamento da interface teve pouca significância na força última dos consolos moldados em duas etapas. Já na abertura dessa interface, verificou-se influência apenas em consolos com armadura de costura presentes.
5

Investigation into a beam-column connection in precast concrete

Zang, Jin 03 1900 (has links)
Thesis (MScEng (Civil Engineering))--University of Stellenbosch, 2010. / ENGLISH ABSTRACT: Pre-cast sections have the advantages of structural efficiency, better quality control and less construction time, which enable them to be widely used in building structures. The connections of pre-cast buildings play a vital role for the stability and strength of structures. Nowadays, more attention is drawn to the aesthetical appearance of building structures, especially by architects. The Hidden Corbel Connection (HCC) was then developed to make the building structures stable and aesthetically pleasing. A modified HCC was designed and investigated in this study. Amongst all the mechanisms in the connection zone, the mechanism of the end anchorage length of tension reinforcement plays a key role in the economy of the connection and is hence further investigated. In order to investigate whether the end anchorage length of tension reinforcement can be reduced for a simply supported beam, a 2D non-linear finite element model is used to analyze the stress distribution inside the connection zone. Based on the stress distribution in the connection zone, the tensile force was calculated at the face of the support, which directly correlates to the required end anchorage length of tension reinforcement. The confinement in the connection zone increases the bond stress, which in turn reduces the required anchorage length of tension reinforcement. Therefore, a 3D model is used to analyze the region inside the modified HCC to find the position of the best confinement. By comparing the finite element (FE) results with Eurocode 2 (2004), and SABS 0100-1 (2000), it is demonstrated that the FE results require the shortest anchorage length, while the longest anchorage length is specified in SABS 0100-1 (2000). Based on the comparison between the FE results and the design codes, a laboratory experiment was then performed to determine if the end anchorage length of tension reinforcement can be reduced. Four beams with different support conditions and with different end anchorage length of tension reinforcement were tested. The results of the laboratory experiment indicate that the end anchorage length for simply supported beams can be shortened from the specification of SABS 0100-1 (2000).
6

Ligações de montagem viga-pilar para estruturas de concreto pré-moldado: estudo de caso / Assembly connections beam-column for structures of precast concrete: case study

Prado, Lisiane Pereira 19 September 2014 (has links)
A pesquisa em questão é direcionada ao estudo de uma ligação provisória entre o pilar e a viga pré-moldada para que possa servir de suporte durante a execução da ligação de estrutura, que consiste na utilização de barras de aço salientes do pilar e da viga, traspassando entre si, finalizada por concreto com adição de fibras. O uso de consolo metálico formado por perfil tipo \"U\" e dente metálico constituído de um perfil de seção retangular vazado foi o método proposto para a ligação provisória, na qual a montagem da viga no pilar se dá pelo encaixe dos elementos. O modelo adotado como dente metálico é denominado \"Cazaly Hanger\". Para avaliar o comportamento da ligação estudada foram analisados os modelos analíticos referentes aos elementos da ligação e, posteriormente, foi montado um pórtico estrutural com a ligação provisória em estudo, para analisar o seu comportamento sob um carregamento estático e monotônico. Inicialmente foi aplicada uma força referente a 71,75% da capacidade da ligação, no meio do vão da viga e excêntrico ao seu eixo para analisar a torção na ligação, simulando uma possível força acidental que venha a ocorrer durante a montagem dos elementos. Na segunda etapa foi aplicada uma força a 1/2,94 do vão da viga a fim de determinar a capacidade do dente metálico e, na terceira e última etapa, o carregamento foi aplicado a 1/7,14 do vão da viga, na extremidade oposta a força aplicada na etapa 2, para determinar a capacidade de suporte do consolo metálico. Os resultados dos ensaios mostraram que a capacidade resistida pelo dente metálico foi 33% maior que o determinado no modelo analítico e, o estado limite último do consolo metálico constituído por perfil \"U\" foi caracterizado pela deformação excessiva da alma, na região superior do consolo. Pode-se concluir que o modelo de cálculo usado no trabalho foi coerente com os resultados encontrados para o dente metálico, mas, para os consolos metálicos, os valores teóricos não foram compatíveis com os resultados encontrados no modelo prático. / The research is directed to the study of a beam-column temporary connections to provide support during the execution of structure connection, which consist on using steel bars protruding from the column and beam finalized by addition of concrete with fibers. The use of steel \"U\" shaped corbel in the column and a steel hangers rectangular hollow core section in the beam was proposed for temporary connection method, in which the erecting the beam in the columns occurs by the nest of the elements. To evaluate the behavior of the studied connections it was analyzed the analytical models of connections and, after were building a structural portico with the connection to analyze their behavior under static and monotonic loading. Initially it was applied a load corresponding to 71,75% of the connection capacity, mid-span of the beam and its eccentric to check the torsion moment on the connection, simulating a possible live load that may occur during assembly of the elements. In the second stage was applied a load of 1/2,94 span beam to determine the capacity of steel hanger rectangular hollow core section and the third and last step the load was applied at 1/7,14 span of the beam, the end opposite the load applied in step 2, to determine the ability of the steel \"U\" shaped corbel. The results showed that the steel hanger inserted capacity was 33% higher than determined in the analytical model and the ultimate limit state of the steel \"U\" shaped corbel was characterized by excessive deformation of vertical plate, in the upper region of corbel. Can conclude that the calculation model used in the study was consistent with the results found for the steel hangers rectangular hollow core section, but for the steel \"U\" shaped corbel, the theoretical values were not consistent with the results found in practical model.
7

Estudo teórico-experimental de ligação viga-pilar com consolo metálico embutido em estruturas pré-moldadas de concreto / Estudo Teórico-Experimental de Ligação Viga-Pilar com Consolo Metálico Embutido em Estruturas Pré-Moldadas de Concreto

Bachega, Luís Augusto 14 February 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:18Z (GMT). No. of bitstreams: 1 5038.pdf: 12517869 bytes, checksum: 373976ca3c8851e35a4dbd3dd53ff661 (MD5) Previous issue date: 2013-02-14 / Financiadora de Estudos e Projetos / This study aimed to analyze the structural behavior of a beam-column connection with embedded steel member for precast concrete with no current use still in Brazil. Based on the literature review about hidden corbels found in international technical references, a type of hidden corbel with embedded steel section (so called billet) was selected for this research. Although there are many different analytical models for the design of the billet within the available technical literature, the focus of this research was on the revised models found in the most recent design manuals PCI (2010) and FIB (2011). In addition to the analytical study an experimental investigation was conducted, wherein isolated column members with billet corbels were tested primarily to a full scale test of a sub-frame with two beams six meters long and with a central column assembled in cruciform shape. For the isolated model, named PI Model (Isolated steel corbel), the behavior of the steel corbel and its interaction with the column were evaluated. For the full scale test, named LI Model (connection zone model), the behavior of the connection zone and the behavior of the beam were studied interacting together. For both the theoretical and the experimental studies, the selected billet consisted of a rectangular hollow section of 200 mm x 100 mm x 10 mm in height, width and thickness, respectively. For the PI Model test, the billet showed a rigid behavior and it was capable of resist an applied load of 700 kN with no damage within the concrete of the column. For the case of LI Model, the experimental study analyzed the behavior of the whole connection zone, comprising both the steel corbel and the end of the beam near the corbel. For this case, the connection behaved as rigid until the applied shear force at the connection reached between 239,5 kN and 238,3 kN, for which the flexural stiffness of the connection acted as rigid, with fixity factors of 1.0 and 0.96, for the left and right connections, respectively. The failure of the model occurred at the cast in place topping of the composite beam when the shear force reached 473.5 kN. The comparison between the experimental results with the theoretical values demonstrated that the isolate billet showed compatible resistance with the expected but that the region of the beam top end showed premature failure due to lack of reinforcement in the region of the end of the beam. It is believed that this effect occurred because of the fact that the detailing followed from studies conducted in the UK is suitable for hinged connections while the connection analyzed in this research comprised of continuous negative reinforcing bars passing through the columns within the cast in place topping of the composite precast beam. Finally, this study presents further recommendations for improvements of the reinforcement detailing of the precast beam. / O estudo teve como objetivo principal analisar o comportamento estrutural de uma ligação viga-pilar com Consolo Metálico Embutido para estruturas pré-moldadas de concreto com uso ainda não corrente no Brasil. Após uma revisão bibliográfica sobre os principais consolos metálicos embutidos encontrados nas referências técnicas internacionais, escolheu-se um tipo de consolo metálico embutido que emprega um perfil metálico (chamado tarugo metálico). A revisão bibliográfica permitiu encontrar na literatura técnica e acadêmica vários modelos analíticos para o dimensionamento do perfil metálico, mas o estudo no presente trabalho se concentrou nos modelos revisados encontrados nos manuais do PCI (2010) e da FIB (2011). Além do estudo analítico, foram realizados ensaios exploratórios primeiramente em consolos no pilar isolado e em seguida foi ensaiado um modelo em escala real com duas vigas de seis metros e um pilar central. No primeiro modelo, denominado modelo de ensaio PI (Pilar Isolado), estudou-se o comportamento isolado do consolo e sua interação junto ao pilar. No segundo modelo, denominado modelo de ensaio LI (Ligação), estudou-se o comportamento da região da ligação e de interação com a viga. Para o estudo teórico-experimental, o tarugo metálico escolhido teve perfil retangular vazado de 200 mm x 100 mm x 10 mm de altura, largura e espessura respectivamente. No ensaio do modelo PI, o consolo metálico apresentou um comportamento rígido e foi capaz de suportar uma carga aplicada de 700 kN sem danos dentro do concreto do pilar. Já no caso do modelo LI, o estudo experimental analisou o comportamento conjunto da ligação, envolvendo tanto o consolo metálico quanto a extremidade da viga próximo ao consolo. Para este caso, a ligação se comportou como rígida para uma força cortante entre 239,5 kN e 238,3 kN, para a qual se estimou um momento de engastamento variando entre 1,0 e 0,96 para a ligação da esquerda e direita, respectivamente. Ocorreu ruptura por cisalhamento na capa de concreto na extremidade da viga quando a força cortante na seção atingiu 473,5 kN. A comparação dos resultados experimentais com os valores teóricos de cálculo demonstrou que o consolo isolado apresentou resistência compatível com o esperado, mas que a região da capa na extremidade da viga apresentou uma falha prematura devido à falta de armadura de costura na região da extremidade da viga. Acredita-se que este efeito tenha ocorrido em virtude do fato de que o detalhamento seguido a partir de estudos realizados no Reino Unido seja indicado para ligações articuladas, enquanto a ligação analisada consistiu de uma ligação com continuidade na armadura negativa. Por esta razão, este estudo apresenta recomendações para melhorias no detalhamento da viga.
8

[en] EXPERIMENTAL STUDY OF REINFORCED CONCRETE SHORT CORBELS WITH CARBON FIBER COMPOSITES / [pt] ESTUDO EXPERIMENTAL DOS CONSOLES CURTOS DE CONCRETO ARMADO REFORÇADOS COM COMPÓSITOS DE FIBRAS DE CARBONO

LARISSA AZEVEDO CURTY 29 January 2018 (has links)
[pt] Este trabalho é uma pesquisa experimental realizada no Laboratório de Estruturas e Materiais da PUC–Rio, utilizando–se a técnica de aplicação do compósito de fibras de carbono (CFC) colados externamente em consoles curtos de concreto armado. Foram ensaiados seis consoles curtos, sendo: um de referência, três com reforço de CFC na horizontal e dois com reforço de CFC na diagonal. A resistência média do concreto aos 28 dias foi de 30 MPa. A seção transversal do pilar foi de 25 cm × 50 cm e a seção do transversal console foi de 25 cm × 37,5 cm. O diâmetro da armadura tracionada em laço era de 10 mm e o diâmetro da armadura de costura era de 6,3 mm. Os consoles foram instrumentados com extensômetros elétricos de resistência na armadura tracionada, no estribo, no concreto e no CFC. Os ensaios comprovaram um razoável desempenho dessa técnica de reforço. Os resultados experimentais foram comparados com os resultados obtidos no modelo de Bielas e Tirantes e no modelo cinemático da Teoria da Plasticidade, visando a comparação das forças verticais últimas teóricas e experimentais. Foi avaliado o ângulo de inclinação das bielas e o fator de efetividade da deformação específica no reforço de CFC. / [en] This work is an experimental research of concrete short corbels wrapped with Carbon Fiber Reinforced Polymer (CFRP) strips. Different strengthening configurations were used. Was carried out on six corbels strengthened by CFRP. One control specimen without CFRP, three corbels with horizontal CFRP strips and two corbels with diagonal CFRP strips. The concrete had a 28 day compressive strength of 30 MPa. The column cross-section dimensions were 25 cm x 50 cm and the corbel cross-section dimensions were 25 cm x 37,5 cm. The flexural reinforcement consisted of four deformed bars each of diameter 10 mm with four transverse bars of diameter 6,3 mm. The corbels were instrumented with strain gages in flexural reinforcement, stirrup, concrete surface and CFRP strips. The analytical models based on Strut-and-Tie model and in the kinematic model of the Theory of Plasticity, allows one to determine the bearing capacity of corbels. The experimental values are then compared with the analytical results, showing good agreement. The strut angle and the strengthening effectiveness were evaluated.
9

Ligações de montagem viga-pilar para estruturas de concreto pré-moldado: estudo de caso / Assembly connections beam-column for structures of precast concrete: case study

Lisiane Pereira Prado 19 September 2014 (has links)
A pesquisa em questão é direcionada ao estudo de uma ligação provisória entre o pilar e a viga pré-moldada para que possa servir de suporte durante a execução da ligação de estrutura, que consiste na utilização de barras de aço salientes do pilar e da viga, traspassando entre si, finalizada por concreto com adição de fibras. O uso de consolo metálico formado por perfil tipo \"U\" e dente metálico constituído de um perfil de seção retangular vazado foi o método proposto para a ligação provisória, na qual a montagem da viga no pilar se dá pelo encaixe dos elementos. O modelo adotado como dente metálico é denominado \"Cazaly Hanger\". Para avaliar o comportamento da ligação estudada foram analisados os modelos analíticos referentes aos elementos da ligação e, posteriormente, foi montado um pórtico estrutural com a ligação provisória em estudo, para analisar o seu comportamento sob um carregamento estático e monotônico. Inicialmente foi aplicada uma força referente a 71,75% da capacidade da ligação, no meio do vão da viga e excêntrico ao seu eixo para analisar a torção na ligação, simulando uma possível força acidental que venha a ocorrer durante a montagem dos elementos. Na segunda etapa foi aplicada uma força a 1/2,94 do vão da viga a fim de determinar a capacidade do dente metálico e, na terceira e última etapa, o carregamento foi aplicado a 1/7,14 do vão da viga, na extremidade oposta a força aplicada na etapa 2, para determinar a capacidade de suporte do consolo metálico. Os resultados dos ensaios mostraram que a capacidade resistida pelo dente metálico foi 33% maior que o determinado no modelo analítico e, o estado limite último do consolo metálico constituído por perfil \"U\" foi caracterizado pela deformação excessiva da alma, na região superior do consolo. Pode-se concluir que o modelo de cálculo usado no trabalho foi coerente com os resultados encontrados para o dente metálico, mas, para os consolos metálicos, os valores teóricos não foram compatíveis com os resultados encontrados no modelo prático. / The research is directed to the study of a beam-column temporary connections to provide support during the execution of structure connection, which consist on using steel bars protruding from the column and beam finalized by addition of concrete with fibers. The use of steel \"U\" shaped corbel in the column and a steel hangers rectangular hollow core section in the beam was proposed for temporary connection method, in which the erecting the beam in the columns occurs by the nest of the elements. To evaluate the behavior of the studied connections it was analyzed the analytical models of connections and, after were building a structural portico with the connection to analyze their behavior under static and monotonic loading. Initially it was applied a load corresponding to 71,75% of the connection capacity, mid-span of the beam and its eccentric to check the torsion moment on the connection, simulating a possible live load that may occur during assembly of the elements. In the second stage was applied a load of 1/2,94 span beam to determine the capacity of steel hanger rectangular hollow core section and the third and last step the load was applied at 1/7,14 span of the beam, the end opposite the load applied in step 2, to determine the ability of the steel \"U\" shaped corbel. The results showed that the steel hanger inserted capacity was 33% higher than determined in the analytical model and the ultimate limit state of the steel \"U\" shaped corbel was characterized by excessive deformation of vertical plate, in the upper region of corbel. Can conclude that the calculation model used in the study was consistent with the results found for the steel hangers rectangular hollow core section, but for the steel \"U\" shaped corbel, the theoretical values were not consistent with the results found in practical model.
10

Comportement mécanique de console courte en béton armé renforcée ou réparée par collage des matériaux composites / Mechanical behavior of short concrete corbels reinforced or repaired by bonding of composite materials

Ivanova, Ivelina 19 December 2013 (has links)
Ce travail porte sur l'étude du comportement mécanique d'une console courte en béton armé renforcée par collage de tissus en fibres de carbone et en particulier sur l'influence du nombre de couches de tissus en fibres de carbone, du type du renforcement, de l'orientation des tissus composites, du type de tissus en fibres de carbone. Les résultats montrent que la performance de la console n‘augmente pas linéairement en fonction de l'épaisseur de la plaque composite. Il existe une épaisseur optimale de tissus en fibres de carbone. Dans le cas du renforcement sur les deux faces du béton, il existe un nombre de couches optimales. Dans le cas du renforcement par bandage, l'épaisseur de matériaux composites plus intéressants est de trois couches. Par contre, la résistance de la console renforcée dépend fortement de la surface renforcée. Les résultats montrent également que le comportement d'une console renforcée peut être présenté en trois phases: la phase élastique globale, la phase de la propagation de fissures et la phase de l'ouverture des fissures diagonales. Le renforcement de la console permet d'augmenter considérablement la résistance ultime de 20 à 82% et la rigidité de la console. Les ruptures des consoles renforcées peuvent être résumées en cinq modes. En se basant sur les résultats obtenus et les modèles existants, la résistance ultime de la console renforcée et non renforcée a été estimée et analysée. Un modèle basant sur lа théorie de l'endommagement a été développé dans ce travail. L'effet de fatigue sur le comportement et sur la résistance ultime de la console courte renforcée a été également étudié dans ce travail. / This study deals with mechanical behaviour of strengthening reinforced concrete corbel by bonding carbon fibre sheet and in particular the influence of the number of layers of carbon fiber fabric, the type of strengthening, the orientation of the composite fabric and the type of carbon fiber fabrics .The results show that the performance of the corbel does not increase linearly with the thickness of the composite plate. There is an optimum thickness of the carbon fiber fabrics. In the case of strengthening on both sides of the concrete, there are an optimum number of layers. In the case of fully wrapped strengthening, the most interesting thickness of the composite is three layers. However, the resistance of the strengthening reinforced concrete corbel depends strongly on the bonded surface.The results also show that the behavior of strengthening corbel can be presented in three phases: the overall elastic phase, the phase of crack propagation and the phase of the opening of diagonal cracks. Strengthening the corbel can significantly increase the ultimate strength from 20% to 82 % and the stiffness of the corbel. The failure of the strengthening corbel can be summarized in five modes.Based on the results obtained and the existing models, the ultimate strength of the strengthening corbel or without strengthening, was estimated and analyzed. A model based on damage theory has been developed in this work. The effect of fatigue on the behavior and ultimate strength of the reinforced concrete corbel has also been studied.

Page generated in 0.0226 seconds