• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise e dimensionamento de lajes lisas protendidas sem aderência

Carneiro, Anselmo Leal 25 September 2015 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2015-10-20T19:05:45Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Analise e dimensionamento de lajes lisas protendidas sem aderencia.pdf: 4457304 bytes, checksum: f0f6d1374146e6d686c522c8682209f2 (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2015-10-29T18:57:25Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Analise e dimensionamento de lajes lisas protendidas sem aderencia.pdf: 4457304 bytes, checksum: f0f6d1374146e6d686c522c8682209f2 (MD5) / Made available in DSpace on 2015-10-29T18:57:25Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Analise e dimensionamento de lajes lisas protendidas sem aderencia.pdf: 4457304 bytes, checksum: f0f6d1374146e6d686c522c8682209f2 (MD5) Previous issue date: 2015 / CAPES / Este trabalho se propõe apresentar a resolução de uma laje lisa protendida com cordoalhas não aderentes, abordando principalmente modos de distribuição das cordoalhas na laje, modelos de cálculo e opções de faixas de projeto para análise do pavimento. O dimensionamento quanto ao estado limite último e de serviço se baseia na NBR 6118:2014, mas há algumas prescrições do ACI 318-11 e do ACI 423.3R-05, que se mostram relevantes para a finalidade do trabalho. O dimensionamento se restringe à flexão, não sendo analisado o esforço cortante na ligação laje-pilar (efeito de punção). A análise da laje ocorre por meio da analogia de grelha, utilizando-se o programa comercial CAD/TQS, e do método dos pórticos múltiplos, utilizando-se o programa FTOOL. Tanto no método de grelha quanto nos pórticos, ocorre a inserção de todos os carregamentos atuantes, inclusive os carregamentos equivalentes de protensão. Verificou-se que a distribuição das cordoalhas do modo concentrados e uniformes apresentou vantagens em relação à distribuição dos momentos fletores e deslocamentos da laje. O balanceamento para 60% da carga permanente resultou em protensão parcial, porém como a fissuração ocorreu apenas próximo aos apoios, a análise de deslocamentos considerando a inércia bruta se mostrou suficiente. A diferença no consumo de armaduras entre os métodos de cálculo foi de até 22%. / This report is proposed to present the resolution of a post-tensioned flat slab set with unbonded tendons, mainly covering layouts of tendons, calculation models and design strips options for floor analysis. The dimensioning regarding the ultimate limit state and service is based on NBR 6118:2014, however, there are some requirements from ACI 318-11 and ACI 423.3R-05, which show relevance towards this report aim. The dimensioning is restricted to flexion, not including the punching shear effect. The slab analysis occurs by means of grid analogy, in terms of the commercial program CAD/TQS, as well as multiple frames’ method regarding the FTOOL program. Both the grid method and frames, the inserting of all operating loads occurs, including the equivalent post-tensioned loads. It was concluded that the banded and distributed tendon layout presented advantages in relation to distribution of bending moments and deflections of the slab. The balancing for 60% of the dead load resulted in partial post-tension, but since cracking occurred only near the supports, the deflection analysis considering gross inertia proved enough. The difference in reinforcement consumption between calculation models was up to 22%.
2

Aderência de cordoalhas em concretos de alta resistência com e sem fibras de aço / Bond of strands embedded in plain and steel fiber reinforced high strength concrete

Dumêt, Tatiana Bittencourt 25 July 2003 (has links)
Este trabalho apresenta os resultados das investigações teórica e experimental sobre a aderência de cordoalhas pré-tracionadas, em concretos de alta resistência com e sem fibras de aço. Foram utilizadas cordoalhas de sete fios com &#934p 12,7 mm e fibras de aço curtas, com ganchos nas extremidades (DRAMIX) e fator de forma 1/d=45. Foram realizados dois tipos de ensaios: arrancamento e flexão em viga. Os parâmetros estudados foram: comprimento de ancoragem (5&#934p, 7&#934p e 15&#934p), volume de fibra (zero, 40 kg/m3 e 60 kg/m3 e grau de protensão (zero e 0,8fptk). O concreto apresentou resistências à compressão de 50 MPa no momento da transferência da protensão e 68 MPa na data de ensaio, aproximadamente. Os resultados dos dois tipos de ensaio foram analisados e comparados com as prescrições normativas da NBR 6118 (2001), da FIB Bulletin 1 (1999) e do ACI 318 (2002), onde verificou-se que as prescrições se encontram a favor da segurança. A conclusão principal resultante desta pesquisa foi que a utilização de fibras com 40 kg/\'m3 por metro quadrado não influi na aderência. Já para um volume de fibra de 60 kg/\'m3 por metro quadrado há um ganho de aproximadamente 28% na aderência, em relação aos concretos sem fibras de aço, nos ensaios de arrancamento. Para as vigas, não houve ganho de aderência para os volumes de fibra utilizados, nem na determinação do comprimento de transferência, nem na do comprimento de ancoragem necessário. / This study presents the results of a theoretical and an experimental investigation of the bond of pretensioned strands embedded in plain and steel fiber reinforced high strength concrete. There were used seven wires strands with 12,7 mm diameter and short hooked steel fibers with an aspect ratio of 1/d=45. Two types of tests were carried out to obtain the bond characteristics of the strands: pullout tests and beam under flexure tests. The parameters studied were the volume fraction (0%, 0,51% and 0,76%) of the fibers, and the degree of prestress of the strand (zero and 0,8fptk). The concrete compressive strength was 50 MPa at transfer (3 days of age) and 68 MPa at 28 days of age (test date), approximately. The results were analyzed and compared to the provisions of the following Codes: NBR 6118 (2001) (Brazilian code under public consult), ACI-318 (2002) and FIB-Bulletin 1 (1999). The comparison indicated that the codes give a safe design. The main conclusion of this work was that the use of 0,5% of steel fibers does not influence the bond strength of the strand. The use of 0,76% of steel fibers increases the bond stress in 28% when compared with plain concrete, for the pullout tests. For the beam\'s tests there was no bond improvement due to the steel fibers, in both case (0,5% and (0,76%), neither for the transfer length nor for the development length.
3

Aderência de cordoalhas em concretos de alta resistência com e sem fibras de aço / Bond of strands embedded in plain and steel fiber reinforced high strength concrete

Tatiana Bittencourt Dumêt 25 July 2003 (has links)
Este trabalho apresenta os resultados das investigações teórica e experimental sobre a aderência de cordoalhas pré-tracionadas, em concretos de alta resistência com e sem fibras de aço. Foram utilizadas cordoalhas de sete fios com &#934p 12,7 mm e fibras de aço curtas, com ganchos nas extremidades (DRAMIX) e fator de forma 1/d=45. Foram realizados dois tipos de ensaios: arrancamento e flexão em viga. Os parâmetros estudados foram: comprimento de ancoragem (5&#934p, 7&#934p e 15&#934p), volume de fibra (zero, 40 kg/m3 e 60 kg/m3 e grau de protensão (zero e 0,8fptk). O concreto apresentou resistências à compressão de 50 MPa no momento da transferência da protensão e 68 MPa na data de ensaio, aproximadamente. Os resultados dos dois tipos de ensaio foram analisados e comparados com as prescrições normativas da NBR 6118 (2001), da FIB Bulletin 1 (1999) e do ACI 318 (2002), onde verificou-se que as prescrições se encontram a favor da segurança. A conclusão principal resultante desta pesquisa foi que a utilização de fibras com 40 kg/\'m3 por metro quadrado não influi na aderência. Já para um volume de fibra de 60 kg/\'m3 por metro quadrado há um ganho de aproximadamente 28% na aderência, em relação aos concretos sem fibras de aço, nos ensaios de arrancamento. Para as vigas, não houve ganho de aderência para os volumes de fibra utilizados, nem na determinação do comprimento de transferência, nem na do comprimento de ancoragem necessário. / This study presents the results of a theoretical and an experimental investigation of the bond of pretensioned strands embedded in plain and steel fiber reinforced high strength concrete. There were used seven wires strands with 12,7 mm diameter and short hooked steel fibers with an aspect ratio of 1/d=45. Two types of tests were carried out to obtain the bond characteristics of the strands: pullout tests and beam under flexure tests. The parameters studied were the volume fraction (0%, 0,51% and 0,76%) of the fibers, and the degree of prestress of the strand (zero and 0,8fptk). The concrete compressive strength was 50 MPa at transfer (3 days of age) and 68 MPa at 28 days of age (test date), approximately. The results were analyzed and compared to the provisions of the following Codes: NBR 6118 (2001) (Brazilian code under public consult), ACI-318 (2002) and FIB-Bulletin 1 (1999). The comparison indicated that the codes give a safe design. The main conclusion of this work was that the use of 0,5% of steel fibers does not influence the bond strength of the strand. The use of 0,76% of steel fibers increases the bond stress in 28% when compared with plain concrete, for the pullout tests. For the beam\'s tests there was no bond improvement due to the steel fibers, in both case (0,5% and (0,76%), neither for the transfer length nor for the development length.
4

Dimensionamento à punção em apoios internos de lajes protendidas sem aderência

Leite Júnior, José Carlos Cirino 14 August 2015 (has links)
Submitted by Morgana Andrade (morgana.andrade@ufes.br) on 2016-03-22T19:49:43Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) jose carlos cirino leite junior.pdf: 4435177 bytes, checksum: 8e8f6eb9e0f91d4f07653b556647e567 (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-03-23T15:31:40Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) jose carlos cirino leite junior.pdf: 4435177 bytes, checksum: 8e8f6eb9e0f91d4f07653b556647e567 (MD5) / Made available in DSpace on 2016-03-23T15:31:40Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) jose carlos cirino leite junior.pdf: 4435177 bytes, checksum: 8e8f6eb9e0f91d4f07653b556647e567 (MD5) / Esta dissertação trata da punção em lajes protendidas com cordoalhas não aderentes, para pilares internos, calculadas através das normas ABNT NBR 6118:2007, ABNT NBR 6118:2014, EN 1992-1-1:2004 e ACI 318-11. Ao longo do trabalho, são apresentados dimensionamentos à punção através desses códigos a fim de se obter uma análise comparativa dos resultados. Além disso, são expostas três situações de provas de carga não destrutivas para punção, realizadas em lajes reais. Os casos, verificados a partir da comparação entre as quatro normas, servem de base para avaliações sobre o nível de segurança estrutural entre os dimensionamentos. Após as análises teóricas, conclui-se que, no geral, o EC2:2004 e a NBR 6118:2014 são os códigos que geram os resultados menos conservadores no cálculo das armaduras de punção. Já o ACI 318-11 e a NBR 6118:2007 obtêm os resultados mais conservadores para esse dimensionamento. Quando considerados os carregamentos máximos sem utilização de armadura de punção, a norma americana se destaca, obtendo valores comparáveis aos do EC2:2004 e da NBR 6118:2014. A NBR 6118:2007 resulta em dimensionamentos sempre mais conservadores. / This work studies the punching shear in prestressed slabs with unbonded tendons, for internal columns, calculated by ABNT NBR 6118:2007, ABNT NBR 6118:2014, EN 1992-1-1:2004 and ACI 318-11. Punching shear calculations will be presented in order to obtain comparative results analysis. Also, there are three situations presented of non-destructive load tests for punching shear, in real slabs. The cases, calculated using the four compared regulation codes, provide a basis for assessments of the conservatism level among the formulations. After the theoretical analysis, in general, it is concluded that EC2:2004 and NBR 6118:2014 are the codes that generate less conservative results in punching shear calculation. However, ACI 318-11 and the NBR 6118:2007 obtain the most conservative results for this design. Considering the maximum loads without the use of punching shear reinforcement ACI 318 generates values comparable to EC2 and NBR 6118:2014. The most conservative results are always generated by NBR 6118:2007.

Page generated in 0.0297 seconds