Computer Assisted Coronary CT Angiography Analysis : Disease-centered Software Development

Wang, Chunliang January 2009 (has links)
<p>The substantial advances of coronary CTA have resulted in a boost of use of this new technique in the last several years, which brings a big challenge to radiologists by the increasing number of exams and the large amount of data for each patient. The main goal of this study was to develop a computer tool to facilitate coronary CTA analysis by combining knowledge of medicine and image processing.Firstly, a competing fuzzy connectedness tree algorithm was developed to segment the coronary arteries and extract centerlines for each branch. The new algorithm, which is an extension of the “virtual contrast injection” method, preserves the low density soft tissue around the coronary, which reduces the possibility of introducing false positive stenoses during segmentation.Secondly, this algorithm was implemented in open source software in which multiple visualization techniques were integrated into an intuitive user interface to facilitate user interaction and provide good over¬views of the processing results. Considerable efforts were put on optimizing the computa¬tional speed of the algorithm to meet the clinical requirements.Thirdly, an automatic seeding method, that can automatically remove rib cage and recognize the aortic root, was introduced into the interactive segmentation workflow to further minimize the requirement of user interactivity during post-processing. The automatic procedure is carried out right after the images are received, which saves users time after they open the data. Vessel enhance¬ment and quantitative 2D vessel contour analysis are also included in this new version of the software. In our preliminary experience, visually accurate segmentation results of major branches have been achieved in 74 cases (42 cases reported in paper II and 32 cases in paper III) using our software with limited user interaction. On 128 branches of 32 patients, the average overlap between the centerline created in our software and the manually created reference standard was 96.0%. The average distance between them was 0.38 mm, lower than the mean voxel size. The automatic procedure ran for 3-5 min as a single-thread application in the background. Interactive processing took 3 min in average with the latest version of software. In conclusion, the presented software provides fast and automatic coron¬ary artery segmentation and visualization. The accuracy of the centerline tracking was found to be acceptable when compared to manually created centerlines.</p>
2

Computer-­Assisted  Coronary  CT  Angiography  Analysis : From  Software  Development  to  Clinical  Application

Wang, Chunliang January 2011 (has links)
Advances in coronary Computed Tomography Angiography (CTA) have resulted in a boost in the use of this new technique in recent years, creating a challenge for radiologists due to the increasing number of exams and the large amount of data for each patient. The main goal of this study was to develop a computer tool to facilitate coronary CTA analysis by combining knowledge of medicine and image processing, and to evaluate the performance in clinical settings. Firstly, a competing fuzzy connectedness tree algorithm was developed to segment the coronary arteries and extract centerlines for each branch. The new algorithm, which is an extension of the “virtual contrast injection” (VC) method, preserves the low-density soft tissue around the artery, and thus reduces the possibility of introducing false positive stenoses during segmentation. Visually reasonable results were obtained in clinical cases. Secondly, this algorithm was implemented in open source software in which multiple visualization techniques were integrated into an intuitive user interface to facilitate user interaction and provide good over­views of the processing results. An automatic seeding method was introduced into the interactive segmentation workflow to eliminate the requirement of user initialization during post-processing. In 42 clinical cases, all main arteries and more than 85% of visible branches were identified, and testing the centerline extraction in a reference database gave results in good agreement with the gold standard. Thirdly, the diagnostic accuracy of coronary CTA using the segmented 3D data from the VC method was evaluated on 30 clinical coronary CTA datasets and compared with the conventional reading method and a different 3D reading method, region growing (RG), from a commercial software. As a reference method, catheter angiography was used. The percentage of evaluable arteries, accuracy and negative predictive value (NPV) for detecting stenosis were, respectively, 86%, 74% and 93% for the conventional method, 83%, 71% and 92% for VC, and 64%, 56% and 93% for RG. Accuracy was significantly lower for the RG method than for the other two methods (p&lt;0.01), whereas there was no significant difference in accuracy between the VC method and the conventional method (p = 0.22). Furthermore, we developed a fast, level set-based algorithm for vessel segmentation, which is 10-20 times faster than the conventional methods without losing segmentation accuracy. It enables quantitative stenosis analysis at interactive speed. In conclusion, the presented software provides fast and automatic coron­ary artery segmentation and visualization. The NPV of using only segmented 3D data is as good as using conventional 2D viewing techniques, which suggests a potential of using them as an initial step, with access to 2D reviewing techniques for suspected lesions and cases with heavy calcification. Combining the 3D visualization of segmentation data with the clinical workflow could shorten reading time.
3

Computer Assisted Coronary CT Angiography Analysis : Disease-centered Software Development

Wang, Chunliang January 2009 (has links)
The substantial advances of coronary CTA have resulted in a boost of use of this new technique in the last several years, which brings a big challenge to radiologists by the increasing number of exams and the large amount of data for each patient. The main goal of this study was to develop a computer tool to facilitate coronary CTA analysis by combining knowledge of medicine and image processing.Firstly, a competing fuzzy connectedness tree algorithm was developed to segment the coronary arteries and extract centerlines for each branch. The new algorithm, which is an extension of the “virtual contrast injection” method, preserves the low density soft tissue around the coronary, which reduces the possibility of introducing false positive stenoses during segmentation.Secondly, this algorithm was implemented in open source software in which multiple visualization techniques were integrated into an intuitive user interface to facilitate user interaction and provide good over¬views of the processing results. Considerable efforts were put on optimizing the computa¬tional speed of the algorithm to meet the clinical requirements.Thirdly, an automatic seeding method, that can automatically remove rib cage and recognize the aortic root, was introduced into the interactive segmentation workflow to further minimize the requirement of user interactivity during post-processing. The automatic procedure is carried out right after the images are received, which saves users time after they open the data. Vessel enhance¬ment and quantitative 2D vessel contour analysis are also included in this new version of the software. In our preliminary experience, visually accurate segmentation results of major branches have been achieved in 74 cases (42 cases reported in paper II and 32 cases in paper III) using our software with limited user interaction. On 128 branches of 32 patients, the average overlap between the centerline created in our software and the manually created reference standard was 96.0%. The average distance between them was 0.38 mm, lower than the mean voxel size. The automatic procedure ran for 3-5 min as a single-thread application in the background. Interactive processing took 3 min in average with the latest version of software. In conclusion, the presented software provides fast and automatic coron¬ary artery segmentation and visualization. The accuracy of the centerline tracking was found to be acceptable when compared to manually created centerlines.