Spelling suggestions: "subject:"torre??o dde fator dde post?ncia"" "subject:"torre??o dde fator dde port?ncia""
1 |
Contribui??es ? estrat?gia de controle sem detec??o de harm?nicos aplicada a um filtro ativo de pot?ncia paraleloSousa, Raphaell Maciel de 24 November 2014 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-02-03T20:53:54Z
No. of bitstreams: 1
RaphaellMacielDeSousa_TESE.pdf: 6489062 bytes, checksum: ad0b83d06c244d254f4775bacae900af (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-02-04T19:25:01Z (GMT) No. of bitstreams: 1
RaphaellMacielDeSousa_TESE.pdf: 6489062 bytes, checksum: ad0b83d06c244d254f4775bacae900af (MD5) / Made available in DSpace on 2016-02-04T19:25:01Z (GMT). No. of bitstreams: 1
RaphaellMacielDeSousa_TESE.pdf: 6489062 bytes, checksum: ad0b83d06c244d254f4775bacae900af (MD5)
Previous issue date: 2014-11-24 / Os esquemas de controle convencionais aplicados em Filtros Ativos de Pot?ncia
Paralelos (FAPPs) utilizam extra??o de ham?nicos, de modo que o desempenho da
compensa??o depende da velocidade e precis?o com que os componentes harm?nicos da
carga n?o linear s?o identificados. O FAPP pode ser implementado sem o uso de extratores
de harm?nicos. Neste caso, a compensa??o dos componentes harm?nicos ? obtida
a partir do balan?o de pot?ncia do sistema. O desempenho da compensa??o no caso em
que o balan?o de pot?ncia ? utilizado depende da velocidade com que o sistema entra em
estado de equil?brio. Neste caso, as correntes de fase s?o indiretamente reguladas por um
controlador de dupla sequ?ncia (Double sequence controller - DSC) com dois graus de
liberdade, cujo o princ?pio do modelo interno (internal mode principle - IMP) ? utilizado
para evitar transforma??es de coordenadas e garantir erro nulo em regime permanente.
Adicionalmente o DSC apresenta robustez quando o FAPP opera sob condi??es de desbalanceamento.
Al?m disso, o FAPP implementado sem esquemas de detec??o compensam
simultaneamente harm?ncos e reativos da carga. Suas capacidades de compensa??o, entretanto,
s?o limitadas pela pot?ncia dispon?vel no conversor do FAPP. Tal restri??o pode
ser minimizada se o n?vel de pot?ncia reativa compensada for flexibilizado. Um esquema
de estima??o que determina as correntes do filtro ? introduzido para conferir flexibilidade
na compensa??o de reativos da carga. Resultados experimentais s?o apresentados para
demonstrar o desempenho do sistema proposto. / The conventional control schemes applied to Shunt Active Power Filters
(SAPF) are Harmonic extractor-based strategies (HEBSs) because their effectiveness depends
on how quickly and accurately the harmonic components of the nonlinear loads
are identified. The SAPF can be also implemented without the use of the load harmonic
extractors. In this case, the harmonic compensating term is obtained from the system active
power balance. These systems can be considered as balanced-energy-based schemes
(BEBSs) and their performance depends on how fast the system reaches the equilibrium
state. In this case, the phase currents of the power grid are indirectly regulated by double
sequence controllers with two degrees of freedom, where the internal model principle is
employed to avoid reference frame transformation. Additionally the DSC controller presents
robustness when the SAPF is operating under unbalanced conditions. Furthermore,
SAPF implemented without harmonic detection schemes compensate simultaneously harmonic
distortion and reactive power of the load. Their compensation capabilities, however,
are limited by the SAPF power converter rating. Such a restriction can be minimized
if the level of the reactive power correction is managed. In this work an estimation scheme
for determining the filter currents is introduced to manage the compensation of reactive
power. Experimental results are shown for demonstrating the performance of the proposed
SAPF system.
|
2 |
Projeto em FPGA de um controlador unificado para corre??o de fator de pot?ncia em retificadores boost bidirecionais monof?sicosSoares, Antonio Wallace Antunes 18 December 2013 (has links)
Made available in DSpace on 2014-12-17T14:56:18Z (GMT). No. of bitstreams: 1
AntonioWAS_DISSERT.pdf: 2078440 bytes, checksum: 8f0b0683ae325a95be82dafa64af1734 (MD5)
Previous issue date: 2013-12-18 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The use of Field Programmable Gate Array (FPGA) for development of digital
control strategies for power electronics applications has aroused a growing interest of
many researchers. This interest is due to the great advantages offered by FPGA, which
include: lower design effort, high performance and highly flexible prototyping. This
work proposes the development and implementation of an unified one-cycle controller
for boost CFP rectifier based on FPGA. This controller can be applied to a total of
twelve converters, six inverters and six rectifiers defined by four single phase VSI
topologies and three voltage modulation types. The topologies considered in this work
are: full-bridge, interleaved full-bridge, half-bridge and interleaved half-bridge. While
modulations are classified in bipolar voltage modulation (BVM), unipolar voltage
modulation (UVM) and clamped voltage modulation (CVM). The proposed project is
developed and prototyped using tools Matlab/Simulink? together with the DSP Builder
library provided by Altera?. The proposed controller was validated with simulation and
experimental results / A utiliza??o de Field Programmable Gate Array (FPGA) para o
desenvolvimento de estrat?gias de controle digital para aplica??es em eletr?nica de
pot?ncia tem despertado um crescente interesse entre muitos pesquisadores. Tal
interesse se deve as grandes vantagens apresentadas pelo FPGA, que incluem: menor
esfor?o de projeto, alto desempenho e grande flexibilidade de prototipagem. Este
trabalho prop?e o desenvolvimento e implementa??o de um controlador unificado,
mediante o uso de FPGA, utilizando a t?cnica de controle de um ciclo (One-Cycle
Control Technique) para corre??o de fator de pot?ncia com retificadores boost. Este
controlador pode ser aplicado a um total de doze conversores, sendo seis inversores e
seis retificadores, definidos pela topologia e pelo tipo de modula??o de tens?o. As
topologias consideradas neste trabalho s?o: ponte completa, ponte completa intercalada,
meia ponte e meia ponte intercalada. Enquanto que as modula??es s?o classificadas em
modula??o bipolar de tens?o (MBT), modula??o unipolar de tens?o (MUT) e
modula??o com grampeamento de tens?o (MGT). O projeto ? desenvolvido e
prototipado utilizando as ferramentas Matlab?/Simulink em conjunto com a biblioteca
DSP Builder, disponibilizada pela Altera?. O controlador proposto ? com resultados de
simula??o e experimentais
|