Spelling suggestions: "subject:"filtro ativa paralelo"" "subject:"tiltro ativa paralelo""
1 |
Sistema de Conversão de Energia Fotovoltaica com Compensação Baseada em Corrente e TensãoAZEVEDO, Gustavo Medeiros de Souza January 2007 (has links)
Made available in DSpace on 2014-06-12T17:39:28Z (GMT). No. of bitstreams: 2
arquivo6905_1.pdf: 3885661 bytes, checksum: fcd58f562637e148348d35d8394e2d26 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2007 / O presente trabalho apresenta uma nova topologia para sistemas de geração
fotovoltaicos conectados à rede elétrica. Essa nova topologia agrega funcionalidades
adicionais aos sistemas fotovoltaicos buscando melhorar a qualidade da energia no
ponto de instalação do sistema.
São apresentados aspectos gerais sobre a geração fotovoltaica e dois dos principais
métodos de rastreamento do ponto de máxima potência (Perturba e Observa e
Condutância Incremental ) são estudados. Uma metodologia para definição dos
parâmetros do método Condutância Incremental é definida.
Duas teorias para determinação dos sinais de compensação de corrente e tensão
são discutidas: a teoria de potência instantânea e a teoria baseada em um sistema de
eixos dq ortogonais girando a velocidade síncrona. O modelo matemático completo do
sistema é feito em referencial dq para elaboração das estratégias de controle. Resultados
de simulação e experimentais do sistema são apresentados e discutidos
|
2 |
Inversor multinível com função de filtro ativo paralelo para sistemas conectados à rede elétricaSANTOS, Antônio Cabral dos 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:41:06Z (GMT). No. of bitstreams: 2
arquivo8972_1.pdf: 8899967 bytes, checksum: 52c9ca9c9a6d1c5bc0fa2bbf2a62cebe (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O desenvolvimento da indústria de dispositivos eletrônicos de potência observado nas
últimas décadas beneficiou a proliferação de cargas não lineares, tais como forno elétrico,
fontes de alimentação chaveada, reguladores de tensão e retificadores. Essas cargas não
lineares absorvem correntes distorcidas e dessa maneira "poluem"a rede elétrica com
harmônicos. A circulação de harmônicos nos sistemas de potência representa um grande
problema na qualidade de energia elétrica. Esses harmônicos distorcem as tensões de
alimentação, aumentam as perdas nos sistemas elétricos e podem provocar problemas de
ressonâncias e mau funcionamento de vários equipamentos eletroeletrônicos. Os prejuízos
econômicos provocados por harmônicos são enormes e a questão da qualidade de energia
elétrica entregue aos consumidores finais é motivo de grande preocupação. Essa dissertação
aborda o inversor de três níveis com função de filtro ativo paralelo. O princípio de
funcionamento do filtro, a técnica de modulação escolhida, as correntes na saída do inversor e o controle da tensão no ponto central dos capacitores são discutidos nessa dissertação.
Também são apresentadas duas técnicas para obter as correntes de referência de controle
do filtro, sendo feitas comparações por simulação. Além disso, é realizado um estudo
comparativo das técnicas de controle de corrente para o filtro ativo paralelo trifásico. A
comparação é feita em termos de conteúdo harmônico, esforço computacional e dificuldade
de implementação
|
3 |
Contribui??es ? estrat?gia de controle sem detec??o de harm?nicos aplicada a um filtro ativo de pot?ncia paraleloSousa, Raphaell Maciel de 24 November 2014 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-02-03T20:53:54Z
No. of bitstreams: 1
RaphaellMacielDeSousa_TESE.pdf: 6489062 bytes, checksum: ad0b83d06c244d254f4775bacae900af (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-02-04T19:25:01Z (GMT) No. of bitstreams: 1
RaphaellMacielDeSousa_TESE.pdf: 6489062 bytes, checksum: ad0b83d06c244d254f4775bacae900af (MD5) / Made available in DSpace on 2016-02-04T19:25:01Z (GMT). No. of bitstreams: 1
RaphaellMacielDeSousa_TESE.pdf: 6489062 bytes, checksum: ad0b83d06c244d254f4775bacae900af (MD5)
Previous issue date: 2014-11-24 / Os esquemas de controle convencionais aplicados em Filtros Ativos de Pot?ncia
Paralelos (FAPPs) utilizam extra??o de ham?nicos, de modo que o desempenho da
compensa??o depende da velocidade e precis?o com que os componentes harm?nicos da
carga n?o linear s?o identificados. O FAPP pode ser implementado sem o uso de extratores
de harm?nicos. Neste caso, a compensa??o dos componentes harm?nicos ? obtida
a partir do balan?o de pot?ncia do sistema. O desempenho da compensa??o no caso em
que o balan?o de pot?ncia ? utilizado depende da velocidade com que o sistema entra em
estado de equil?brio. Neste caso, as correntes de fase s?o indiretamente reguladas por um
controlador de dupla sequ?ncia (Double sequence controller - DSC) com dois graus de
liberdade, cujo o princ?pio do modelo interno (internal mode principle - IMP) ? utilizado
para evitar transforma??es de coordenadas e garantir erro nulo em regime permanente.
Adicionalmente o DSC apresenta robustez quando o FAPP opera sob condi??es de desbalanceamento.
Al?m disso, o FAPP implementado sem esquemas de detec??o compensam
simultaneamente harm?ncos e reativos da carga. Suas capacidades de compensa??o, entretanto,
s?o limitadas pela pot?ncia dispon?vel no conversor do FAPP. Tal restri??o pode
ser minimizada se o n?vel de pot?ncia reativa compensada for flexibilizado. Um esquema
de estima??o que determina as correntes do filtro ? introduzido para conferir flexibilidade
na compensa??o de reativos da carga. Resultados experimentais s?o apresentados para
demonstrar o desempenho do sistema proposto. / The conventional control schemes applied to Shunt Active Power Filters
(SAPF) are Harmonic extractor-based strategies (HEBSs) because their effectiveness depends
on how quickly and accurately the harmonic components of the nonlinear loads
are identified. The SAPF can be also implemented without the use of the load harmonic
extractors. In this case, the harmonic compensating term is obtained from the system active
power balance. These systems can be considered as balanced-energy-based schemes
(BEBSs) and their performance depends on how fast the system reaches the equilibrium
state. In this case, the phase currents of the power grid are indirectly regulated by double
sequence controllers with two degrees of freedom, where the internal model principle is
employed to avoid reference frame transformation. Additionally the DSC controller presents
robustness when the SAPF is operating under unbalanced conditions. Furthermore,
SAPF implemented without harmonic detection schemes compensate simultaneously harmonic
distortion and reactive power of the load. Their compensation capabilities, however,
are limited by the SAPF power converter rating. Such a restriction can be minimized
if the level of the reactive power correction is managed. In this work an estimation scheme
for determining the filter currents is introduced to manage the compensation of reactive
power. Experimental results are shown for demonstrating the performance of the proposed
SAPF system.
|
4 |
Análise de um compensador estático paralelo monofásico visando a melhoria do fator de potência / Analysis of a parallel phase static compensatorAndrade, Adson íkaro Silva Leite de 17 November 2011 (has links)
Made available in DSpace on 2015-05-08T14:59:37Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 2390386 bytes, checksum: 2877d7af65aad5521adb02a684322a1c (MD5)
Previous issue date: 2011-11-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work consists of developing a control system power factor through the use of a parallel active filter. To this end, the control system of the filter is composed of an outer voltage loop and an inner current loop, based on PI controllers. For its development, it was observed that the application of parallel active filters offered by the literature, where it was realized that this type of filter is often used to correct the power factor for the development of control technique were made in modeling system and their analysis in steady state, after, the modeled system, the controllers were implemented and validated by numerical simulation using a test bench where he was led via DSP algorithm implemented PWM technique to control and command keys potency. / Este trabalho consiste no desenvolvimento de um sistema de controle do fator de potência através da utilização de um filtro ativo paralelo. Para tal, o sistema de controle do filtro é composto por uma malha externa de tensão e uma malha interna de corrente, baseadas em controladores PI. Para o desenvolvimento do mesmo, observaram-se as aplicações dos filtros ativos paralelos oferecidos pela literatura, onde se percebeu que esse tipo de filtro é bastante utilizado para a correção do fator de potência, para o desenvolvimento da técnica de controle foram feitas as modelagens do sistema e as suas respectivas análises em regime permanente, após, modelado o sistema, os controladores foram implementados via simulação numérica e validados através de uma bancada de teste comandada via DSP onde foi implementado o algoritmo de controle e a técnica PWM para o comando das chaves de potência.
|
5 |
Implementa??o experimental de filtro ativo paralelo de pot?ncia com aplica??o a gerador de indu??o trif?sicoSilva, Paulo Vitor 28 June 2010 (has links)
Made available in DSpace on 2014-12-17T14:55:44Z (GMT). No. of bitstreams: 1
PauloVS_DISSERT.pdf: 1338370 bytes, checksum: 7f4728ef2faffa30200a5b0daf963f20 (MD5)
Previous issue date: 2010-06-28 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This work describes the experimental implementation of a shunt active power filter applied to a three-phase induction generator. The control strategy of active filter turned to the excitation control of the machine and to decrease the harmonics in the generator
output current. Involved the implementation of a digital PWM switching, and was made a comparison of two techniques for obtaining the reference currents. The first technique is based on the synchronous dq reference method and the second on the theory of instantaneous power. The comparison is performed via simulation and experimental results. To obtain the experimental results, was mounted a bench trial and the control and communications needed were implemented using DSP - MS320F2812. The simulation results and experimental data proved the efficiency of the filter to apply, highlighting the technique of instantaneous power / Este trabalho descreve a implementa??o experimental de um filtro ativo paralelo de pot?ncia aplicado a um gerador de indu??o trif?sico. A estrat?gia de controle do filtro ativo voltou-se para o controle de excita??o da m?quina e para a minimiza??o dos harm?nicos na corrente de sa?da do gerador. Envolveu a implementa??o de um chaveamento PWM digital, tendo sido realizada a compara??o de duas t?cnicas para obten??o das correntes de refer?ncia. A primeira t?cnica se baseia no m?todo referencial s?ncrono dq e a segunda na teoria das pot?ncias instant?neas. A compara??o ? realizada via simula??o e resultados experimentais. Para obten??o dos resultados experimentais, foi montada uma bancada experimental e o controle e comunica??es necess?rias foram implementados utilizando-se um DSP - TMS320F2812. Os resultados de simula??o e experimentais obtidos comprovaram a efici?ncia do filtro para a aplica??o, com destaque para a t?cnica das pot?ncias instant?neas
|
Page generated in 0.0857 seconds