• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 20
  • 20
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Discrete Simulation of Reactive Flow with Lattice Gas Automata

YAMAMOTO, Kazuhiro 01 March 2004 (has links)
No description available.
2

Laboratory Reduction Tests on Prereduced Pellets Under Blast Furnace Conditions with a Counter-Flow Reactor

Hone, Michel Robert 10 1900 (has links)
<p> An experimental investigation has been conducted into the reduction of iron oxides under blast furnace conditions. The necessary equipment has been designed, constructed and tested, and a program of study on two types of prereduced ore materials has been completed.</p> / Thesis / Master of Science (MSc)
3

Velocity and temperature distributions of turbulent plane jet interaction with the nonlinear oppositive progressive gravity wave and ocean current

Li, Zong-Heng 03 August 2011 (has links)
The variation of velocity and temperature distribution in arbitrary profile along the centerline in turbulent which encounters non-linearity regular progressive gravity wave and steady uniform flow right in front are investigated analytically and verified by existing experiments. Firstly, the action of periodic waves and current are incorporated into the equation of motion as an external force and applied radiation stress for evaluating the velocity distribution over arbitrary lateral cross section. Based on the momentum exchange after the interaction between turbulent plane jet and oppositive non-linearity wave and uniform flow, the physical characteristics of jet-wave and current are able to be determined theoretically. Secondly, there are critical sections in both velocity and temperature transport processes when the turbulent plane jet influenced by wave and current motion. Fluctuating function will be close to infinity, is the order of wave sharpness; Average velocity for every wave period along the centerline approach to zero, That¡¦s thanks to the momentum of plane jet is extruded by the momentum of wave and current, Beyond the critical section, characteristics of the jet is no longer existing, such phenomena mean that only the wave and current dominating. Velocity and temperature distribution in the zone of flow developed are Gaussian curve, as has been measured in experiment. The momentum extrusion of counter flow in jet is significant in the deep water and small wave; The velocity distribution coefficient is changing with the increasing of counter flow velocity, owing to the entrainment effect, and the potential core will reducing with the increasing of counter flow velocity.
4

Burning velocity and OH concentration in premixed combustion

Yamashita, H., Hayashi, N., Ozeki, M., Yamamoto, K. January 2009 (has links)
No description available.
5

Ozone Activated Cool Diffusion Flames of Butane Isomers in a Counterflow Facility

Al Omier, Abdullah Abdulaziz 04 1900 (has links)
Proceeding from the aim to reduce global pollution emissions from the continuous burning of hydrocarbons stimulated by increasing energy demand, more efficient and ultra-low emissions’ combustion concepts such as the homogenous charge compression ignition engines (HCCI) have been developed. These new engines rely on the low temperature chemistry (LTC) combustion concept. A detailed investigation of the properties of cool flames, governed by LTC, is essential for the design of these new engines. The primary goal of this work was to build a fundamental counterflow experiment for cool flames studies in a diffusive system, to better understand combustion in LTC engines. The project was intended to provide a basic understanding of the low-temperature reactivity and cool flames properties of butane isomers under atmospheric pressure conditions. This was achieved by establishing self-sustaining cool flames through a novel technique of ozone addition to an oxygen stream in a non-premixed counterflow model. The ignition and extinction limits of butane isomers’ cool flames have been investigated under a variety of strain rates. Results revealed that establishment of cool flames are favored at lower strain rates. Iso-butane was less reactive than n-butane by showing higher ignition and extinction limits. Ozone addition showed a significant influence on cool flame ignition and sustenance; it was found that increasing ozone concentration in the oxidizer stream dramatically increased the reactivity of both fuels. Results showed increased fuel reactivity as the temperature of the fuel stream outlet increased. 4 A numerical analysis was performed to simulate ignition and extinction of the cool flame in diffusive systems. The results revealed that ignition and extinction limits of cool flames are predominantly governed by LTC. The model qualitatively captured experimental trends for both fuels; however, it overpredicted both ignition and extinction limits under all strain rates and ozone concentrations. The discrepancies were within a factor of eight for the ignition limit and a factor of two for the extinction limit. Finally, sensitivity analyses were conducted to understand the reactions responsible for cool flames ignition. It was found that majority of the sensitive reactions are those that occur at low temperatures.
6

Modeling a run-around heat and moisture exchanger using two counter/cross flow exchangers

Vali, Alireza 29 June 2009
In this study, a numerical model is developed for determining coupled heat and moisture transfer in a run-around membrane energy exchanger (RAMEE) using two counter/cross flow exchangers and with a salt solution of MgCl2 as the coupling fluid. The counter/cross flow exchanger is a counter-flow exchanger with cross-flow inlet and outlet headers. The model is two-dimensional, steady-state and based on the physical principles of conservation of momentum, energy, and mass. The finite difference method is used in this model to discretize the governing equations.<p> The heat transfer model is validated with effectiveness correlations in the literature. It is shown that the difference between the numerical model and correlations is less than ¡À2% and ¡À2.5% for heat exchangers and run around heat exchangers (RAHE), respectively. The simultaneous heat and moisture transfer model is validated with data from another model and experiments. The inter-model comparison shows a difference of less than 1%. The experimental validation shows an average discrepancy of 1% to 17% between the experimental and numerical data for overall total effectiveness. At lower NTUs the numerical and experimental results show better agreement (e.g. within 1-4% at NTU=4).<p> The model for RAHE is used to develop new effectiveness correlations for the geometrically more complex counter/cross flow heat exchangers and RAHE systems. The correlations are developed to predict the response of the exchangers and overall system to the change of different design characteristics as it is determined by the model. Discrepancies between the simulated and correlated results are within ¡À2% for both the heat exchangers and the RAHE systems.<p> It is revealed by the model that the overall effectiveness of the counter/cross flow RAMEE depends on the entrance ratio (the ratio of the length of the inlet and outlet headers to the length of the exchanger, xi/x0), aspect ratio (the ratio of the height to the length of the exchanger, y0/x0), number of heat transfer units (NTU), heat capacity rate ratio (Cr*), number of mass transfer units (NTUm), and the mass flow rate ratio of pure salt in desiccant solution to dry air (m*). Beside these dimensionless parameters, the performance of the RAMEE system is affected by the liquid-air flow configuration and the operating inlet temperature and humidity.<p> This study concludes that the maximum effectiveness of the RAMEE system with two counter/cross flow exchangers occurs when NTU and NTUm are large (e.g. greater than 10). At any NTU, the overall effectiveness of the RAMEE system increases with Cr* until it reaches a maximum value when Cr*= . Increasing Cr* above causes the overall effectiveness to decrease slightly. Therefore, to achieve the maximum overall effectiveness of the system, Cr* must be close to . is a function of NTU and operating conditions e.g., with NTU=10, and under AHRI summer and winter operating conditions, respectively. The exchangers in the RAMEE system are needed to have a small aspect ratio (e.g. y0/x0<0.2) and small entrance ratio (e.g. xi/x0<0.1) to get the maximum overall effectiveness of a RAMEE system using two counter/cross flow exchangers. Such a RAMEE system has a total effectiveness 6% higher and 1.5% lower compared to the same cross-flow and counter-flow RAMEE, respectively (at NTU=10, Cr*¡Ö3, y0/x0=0.2 and xi/x0=0.1).
7

Modeling a run-around heat and moisture exchanger using two counter/cross flow exchangers

Vali, Alireza 29 June 2009 (has links)
In this study, a numerical model is developed for determining coupled heat and moisture transfer in a run-around membrane energy exchanger (RAMEE) using two counter/cross flow exchangers and with a salt solution of MgCl2 as the coupling fluid. The counter/cross flow exchanger is a counter-flow exchanger with cross-flow inlet and outlet headers. The model is two-dimensional, steady-state and based on the physical principles of conservation of momentum, energy, and mass. The finite difference method is used in this model to discretize the governing equations.<p> The heat transfer model is validated with effectiveness correlations in the literature. It is shown that the difference between the numerical model and correlations is less than ¡À2% and ¡À2.5% for heat exchangers and run around heat exchangers (RAHE), respectively. The simultaneous heat and moisture transfer model is validated with data from another model and experiments. The inter-model comparison shows a difference of less than 1%. The experimental validation shows an average discrepancy of 1% to 17% between the experimental and numerical data for overall total effectiveness. At lower NTUs the numerical and experimental results show better agreement (e.g. within 1-4% at NTU=4).<p> The model for RAHE is used to develop new effectiveness correlations for the geometrically more complex counter/cross flow heat exchangers and RAHE systems. The correlations are developed to predict the response of the exchangers and overall system to the change of different design characteristics as it is determined by the model. Discrepancies between the simulated and correlated results are within ¡À2% for both the heat exchangers and the RAHE systems.<p> It is revealed by the model that the overall effectiveness of the counter/cross flow RAMEE depends on the entrance ratio (the ratio of the length of the inlet and outlet headers to the length of the exchanger, xi/x0), aspect ratio (the ratio of the height to the length of the exchanger, y0/x0), number of heat transfer units (NTU), heat capacity rate ratio (Cr*), number of mass transfer units (NTUm), and the mass flow rate ratio of pure salt in desiccant solution to dry air (m*). Beside these dimensionless parameters, the performance of the RAMEE system is affected by the liquid-air flow configuration and the operating inlet temperature and humidity.<p> This study concludes that the maximum effectiveness of the RAMEE system with two counter/cross flow exchangers occurs when NTU and NTUm are large (e.g. greater than 10). At any NTU, the overall effectiveness of the RAMEE system increases with Cr* until it reaches a maximum value when Cr*= . Increasing Cr* above causes the overall effectiveness to decrease slightly. Therefore, to achieve the maximum overall effectiveness of the system, Cr* must be close to . is a function of NTU and operating conditions e.g., with NTU=10, and under AHRI summer and winter operating conditions, respectively. The exchangers in the RAMEE system are needed to have a small aspect ratio (e.g. y0/x0<0.2) and small entrance ratio (e.g. xi/x0<0.1) to get the maximum overall effectiveness of a RAMEE system using two counter/cross flow exchangers. Such a RAMEE system has a total effectiveness 6% higher and 1.5% lower compared to the same cross-flow and counter-flow RAMEE, respectively (at NTU=10, Cr*¡Ö3, y0/x0=0.2 and xi/x0=0.1).
8

Superadiabatic combustion in counter-flow heat exchangers

Schoegl, Ingmar Michael 22 March 2011 (has links)
Syngas, a combustible gaseous mixture of hydrogen, carbon monoxide, and other species, is a promising fuel for efficient energy conversion technologies. Syngas is produced by breaking down a primary fuel into a hydrogen-rich mixture in a process called fuel reforming. The motivation for the utilization of syngas rather than the primary fuel is that syngas can be used in energy conversion technologies that offer higher conversion efficiencies, e.g. gas turbines and fuel cells. One approach for syngas production is partial oxidation, which is an oxygen starved combustion process that does not require a catalyst. Efficient conversion to syngas occurs at high levels of oxygen depletion, resulting in mixtures that are not flammable in conventional combustion applications. In non-catalytic partial oxidation, internal heat recirculation is used to increase the local reaction temperatures by transferring heat from the product stream to pre-heat the fuel/air mixture before reactions occur, thus increasing reaction rates and allowing for combustion outside the conventional flammability limits. As peak temperatures lie above the adiabatic equilibrium temperature predicted by thermodynamic calculations, the combustion regime used for non-catalytic fuel reforming is referred to as 'superadiabatic'. Counter-flow heat exchange is an effective way to transfer heat between adjacent channels and is used for a novel, heat-recirculating fuel reformer design. An analytical study predicts that combustion zone locations inside adjacent flow channels adjust to operating conditions, thus stabilizing the process for independent variations of flow velocities and mixture compositions. In experiments, a reactor prototype with four channels with alternating flow directions is developed and investigated. Tests with methane/air and propane/air mixtures validate the operating principle, and measurements of the resulting syngas compositions verify the feasibility of the concept for practical fuel-reformer applications. Results from a two-dimensional numerical study with detailed reaction chemistry are consistent with experimental observations. Details of the reaction zone reveal that reactions are initiated in the vicinity of the channel walls, resulting in "tulip"-shaped reaction layers. Overall, results confirm the viability of the non-catalytic reactor design for fuel reforming applications. / text
9

Films liquides tombants avec ou sans contre-écoulement de gaz : application au problème de l'engorgement dans les colonnes de distillation / Falling liquid films with or without a gazeous counter-flow : application to the problem of flooding in distillation columns

Kofman, Nicolas 07 November 2014 (has links)
Les films liquides tombants et cisaillés par un contre-écoulement de gaz jouent un rôle prépondérant dans de nombreux processus industriels. En effet, les ondes à l'interface gaz/liquide augmentent sensiblement les transferts de chaleur et de masse entre les deux phases. Nous avons cherché, dans un premier temps, à mieux comprendre la dynamique 2D et 3D d'un film liquide tombant sur un plan incliné grâce à des outils expérimentaux (visualisations par ombroscopie, mesures d'épaisseur) et numériques (modèles d'équations réduits, analyses de stabilité). Le point optimal de fonctionnement des procédés se situe proche de la limite d'engorgement caractérisée par un envahissement de l'espace disponible par la phase liquide. Notre objectif, dans un second temps, a été de mieux comprendre les mécanismes physiques à l'origine de l'engorgement grâce à la réalisation d'expériences en géométrie simplifiée (canal plan). Ces travaux s'inscrivent dans le cadre d'un contrat CIFRE entre le laboratoire FAST et la société Air Liquide afin d'appliquer les résultats au procédé de distillation de l'air. Deux dispositifs expérimentaux ont été mis en place : l'un à température ambiante (étude fondamentale), l'autre à température cryogénique (étude appliquée et confidentielle). / Falling liquid films with or without a gazeous counter-flow play a leading role in many industrial process. Indeed, the waves at the gas/liquid interface increase noticeably the heat and mass transfer between both phases. We have tried, as a first step, to better understand the 2D and 3D dynamics of a liquid film falling down an inclined plane using experimental (shadowgraphy visualisations, thickness measurements) and numerical (reduced equation models, stability analysis) tools. The optimal operating conditions are closed to the limit of flooding characterized by an invasion of the available space by the liquid phase. Our goal, as a second step, has been to better understand the physical mechanisms at the origin of flooding using simplified geometry experiments (plane channel). These works fall within a CIFRE contract between the FAST laboratory and the Air Liquide company in order to apply the results to the air distillation process. Two experimental set-ups have been built : one at room temperature (fundamental study), the other at cryogenic temperature (applied and confidential study).
10

CuPGS Laminate Core for a Matrix Microchannel Heat Exchanger

Skog, Torkel January 2019 (has links)
Cryocooling is a continuously developing field of engineering, applied in the fieldsof aerospace, military, and medical sciences among others. There is a demand forsmaller and more efficient cryocoolers for spaceborne low-light observation missions,with many custom cooling systems having completed successful missions. The Stir-ling cycle is the most prevalent refrigeration technique used for space applications,with the pulse-tube, Joule-Thomson or reverse Brayton cycles being used in somespecial cases.A matrix heat exchanger is designed with 3D-printed 17-4 PH stainless steel end capsstreamlined for computer numerical control (CNC) production. The heat exchanger (HX) core consists of 1mm thick stainless steel spacers and 250μm thick copperchips that are tolerance-matched for photo etching, as well as pyrolytic graphitesheets (PGS) of 25μm, the thickest commercially available PGS without addedadhesive film material.The experiments of joining PGS and copper chips with Epo-Tek 301-2 epoxy tocreate a solid core structure for the heat exchanger did not result in a pressure-resistant laminate material. The graphite surface proved difficult to adhere to usingthis epoxy, creating voids, and easily delaminated into separate layers of PGS. Bond-ing the stack together using indium, testing epoxy with a higher ability to permeatethe PGS or diffusion-bonding through other means are presented as options forfurthering the HX development.Pressure testing of a copper-only laminated heat exchanger core showed that theend cap recess adhesion capability is a potential point of failure, as the designedstructure makes it impossible to inspect the results of the bond without curingthe epoxy and pressurising the system. The difficulty in establishing a tight seambetween the main counter-flow channels of the HX is also demonstrated here, asleakage between the channels occurred at pressures in the vicinity of 2

Page generated in 0.2653 seconds