• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Recherche des caractéristiques optimales d'antennes multi-capteurs pour les systèmes MIMO

Vergerio, Sophie 06 July 2007 (has links) (PDF)
La technologie MIMO est une solution intéressante pour répondre à l'augmentation des débits liée au développement des services multimédia dans les systèmes de communications sans fil. Elle promet une augmentation linéaire des débits en fonction du nombre d'antennes à l'émission et à la réception en exploitant la diversité du réseau d'antennes et en tirant parti de la propagation multi-trajets. Cette technologie, déjà utilisée dans les réseaux WLAN, rencontre quelques problèmes en téléphonie<br />mobile. En effet, il n'est pas évident d'implanter plusieurs capteurs sur un terminal de taille compatible avec un téléphone mobile tout en conservant de bonnes performances. La proximité des éléments engendre des couplages provoquant des pertes de puissance émise et des déformations de diagramme.<br /><br />Cette thèse présente la conception d'une antenne à deux éléments rayonnants pour téléphone portable suivie d'une étude sur les performances des systèmes MIMO pour la téléphonie mobile dans des conditions réalistes. La conception d'un simulateur de capacité basé sur un modèle de propagation complet a permis de comparer les antennes et leurs caractéristiques en environnement cellulaire urbain dans la bande UMTS.
2

Contribution à l'étude et à la correction de la diaphonie dans les réseaux de transducteurs piézoélectriques pour l'imagerie médicale

BYBI, Abdelmajid 06 December 2012 (has links) (PDF)
Que ce soit dans le domaine médical ou en contrôle non destructif, les systèmes d'imagerie ultrasonore sont devenus de plus en plus utilisés de nos jours. Leurs applications ne cessent de s'élargir et des performances toujours plus accrues sont vivement recherchées, afin d'améliorer la qualité des diagnostics réalisés. Nous sommes donc passés de l'utilisation de systèmes à base de transducteurs ultrasonores mono-élément à des systèmes utilisant des réseaux de transducteurs à une dimension (1D) et à deux dimensions (2D) composés d'éléments de plus en plus nombreux et petits. Néanmoins, un phénomène indésirable est fortement présent dans ces réseaux de transducteurs ultrasonores : il s'agit du couplage inter-éléments tendant à limiter leurs performances acoustiques et à modifier leur diagramme de rayonnement. Tout au long de ce travail de recherche, nous avons donc cherché à comprendre ce phénomène parasite et à apporter des solutions pour le réduire voire le supprimer. En se basant sur des modélisations éléments finis 2D et 3D et grâce à la fabrication de prototypes, nous avons d'une part, mis en évidence les différents types de couplages présents dans un réseau de transducteurs (acoustique, mécanique) et d'autre part, deux méthodes de correction basées l'une comme l'autre sur l'application de tensions convenables aux différents éléments du réseau ont été testées. La première méthode utilise les déplacements normaux moyens à la surface de chaque élément du réseau pour évaluer ces tensions, tandis que la deuxième fait appel aux courants motionnels parcourant chaque élément pour les déterminer. Les résultats numériques et expérimentaux concernant les déplacements et les diagrammes de rayonnement sont en bon accord. En outre, les deux méthodes s'avèrent particulièrement efficaces pour réduire le couplage inter-éléments.
3

Contribution à l'étude et à la correction de la diaphonie dans les réseaux de transducteurs piézoélectriques pour l'imagerie médicale

Bybi, Abdelmajid 06 December 2012 (has links)
Que ce soit dans le domaine médical ou en contrôle non destructif, les systèmes d’imagerie ultrasonore sont devenus de plus en plus utilisés de nos jours. Leurs applications ne cessent de s’élargir et des performances toujours plus accrues sont vivement recherchées, afin d’améliorer la qualité des diagnostics réalisés. Nous sommes donc passés de l’utilisation de systèmes à base de transducteurs ultrasonores mono-élément à des systèmes utilisant des réseaux de transducteurs à une dimension (1D) et à deux dimensions (2D) composés d’éléments de plus en plus nombreux et petits. Néanmoins, un phénomène indésirable est fortement présent dans ces réseaux de transducteurs ultrasonores : il s’agit du couplage inter-éléments tendant à limiter leurs performances acoustiques et à modifier leur diagramme de rayonnement. Tout au long de ce travail de recherche, nous avons donc cherché à comprendre ce phénomène parasite et à apporter des solutions pour le réduire voire le supprimer. En se basant sur des modélisations éléments finis 2D et 3D et grâce à la fabrication de prototypes, nous avons d’une part, mis en évidence les différents types de couplages présents dans un réseau de transducteurs (acoustique, mécanique) et d’autre part, deux méthodes de correction basées l’une comme l’autre sur l’application de tensions convenables aux différents éléments du réseau ont été testées. La première méthode utilise les déplacements normaux moyens à la surface de chaque élément du réseau pour évaluer ces tensions, tandis que la deuxième fait appel aux courants motionnels parcourant chaque élément pour les déterminer. Les résultats numériques et expérimentaux concernant les déplacements et les diagrammes de rayonnement sont en bon accord. En outre, les deux méthodes s’avèrent particulièrement efficaces pour réduire le couplage inter-éléments. / Whether in medicine or in non-destructive testing, ultrasonic imaging systems have become increasingly used nowadays. Their applications continue to expand and good performances are needed to improve the quality of the diagnosis. Moreover, significant progress has been made since these systems were originally based on single element ultrasonic transducers and are now made of mono-dimensional (1D) and bi-dimensional (2D) elements arrays ever more numerous and smaller. However, an undesirable phenomenon is strongly present in the ultrasonic transducer arrays: it is the cross-talk, which limits their acoustic performances and modifies their radiation pattern. Throughout this research, we have attempted on one hand to understand this parasitic phenomenon and on the other hand to provide solutions in order to reduce it or even remove it. To highlight the cross-talk types (acoustic and mechanical) and to test the proposed correction methods, we developed two-dimensional (2D) and three-dimensional (3D) finite element modeling and fabricated some prototypes. Both correction methods rely on the application of suitable voltages to the array elements. The first method uses the average of the normal displacements at the surface of each element to evaluate the voltages, while the second one utilizes the motional currents through each element to determine them. The numerical and experimental results concerning the displacements and the radiation patterns are in good agreement. In addition to this, both methods have been efficiently performed to reduce the cross-talk.
4

Conception et caractérisation de sondes cMUT large bande pour l'imagerie conventionnelle et l'évaluation du tissu osseux / Design and characterization of broadband cMUT probe for conventional imaging and assessment of bone tissue

Boulmé, Audren 19 December 2013 (has links)
Les transducteurs ultrasonores capacitifs micro-usinés (cMUT : capacitive Micromachined Ultrasound Transducers) apparaissent, au vu de leur maturité croissante, comme une alternative de plus en plus viable à la technologie piézoélectrique. Caractérisés par une large bande passante et une large directivité, ces transducteurs sont des solutions intéressantes pour le développement de sondes ultrasonores « exotiques » dont les spécifications sont difficilement atteignables en technologie piézoélectrique. C'est dans ce contexte et fort de l'expérience acquise par notre laboratoire sur cette technologie pendant plus d'une dizaine d'années, que s'est inscrit ce travail de thèse. L'originalité du travail rapporté ici est d'aller de l'analyse du comportement général des barrettes cMUT jusqu'à un exemple précis de conception de sonde cMUT pour l'évaluation du tissu osseux. Des outils de modélisation précis et rapides, basés sur l'introduction de conditions de périodicité, ont été développés. Plusieurs modèles ont ainsi été mis en place afin d'adapter la stratégie de modélisation à la topologie du dispositif cMUT à modéliser : cellule isolée, colonne de cellules, matrice de cellules et élément de barrette. Ces modèles ont permis d'étudier le comportement des éléments de barrette cMUT et d'améliorer notre connaissance sur les mécanismes physiques mis en jeu. De cette façon, l'origine des effets de baffle, problème récurrent du comportement des barrettes cMUT, a clairement été interprété par l'intermédiaire d'une analyse modale. Des solutions ont ainsi été identifiées et proposées afin d'optimiser le comportement des barrettes cMUT, de façon à réduire la présence des effets de baffle et à augmenter leur bande passante. Le développement d'une barrette cMUT dédiée à l'évaluation du tissu osseux est présenté dans sa totalité, afin d'illustrer les différents aspects liés à la conception d'une sonde de cette technologie. Un travail original de caractérisation a été réalisé sur cette barrette, afin d'estimer l'homogénéité inter-cellules à l'échelle de l'élément et l'homogénéité inter-éléments à l'échelle de la barrette. Enfin, une confrontation a été réalisée avec une sonde PZT de même topologie sur plusieurs fantômes osseux. Il a ainsi été démontré que la sonde cMUT permettait la détection d'un plus grand nombre de modes guidés, et par conséquent, une meilleure évaluation du tissu osseux. / Following recent advances, the capacitive Micromachined Ultrasound Transducers (cMUT) technology seems to be a good alternative to the piezoelectric technology. For specific applications, the requirements and specifications of the probe are sometimes difficult to obtain with the traditional PZT technology. The cMUT technology, with both large bandwidth and angular directivity, can be an interesting way to overcome these limitations. This PhD has been carried out in this context, in a laboratory which has nearly 10 years of experience in the field of cMUT technology. The originality of the work sustained in this PhD is that it covers the cMUT technology, from general aspects dealing of modeling and characterization up to a complete example of cMUT-based probe applied to the assessment of cortical bone. Fast and accurate modeling tools, based on periodicity conditions, have been developed. Several models have been proposed to match the modeling strategy to the topology of the cMUT array : isolated cell, columns of cells, 2-D matrix of cells and array element. These models have been used to analyze the cMUT array behavior and to understand how mutual couplings between cMUTs impact the response of one element. Origins of the baffle effect, well-known as a recurrent problem in cMUT probe, have been explained using an original method based on the normal mode decomposition of the radiated pressure field. Thus, solutions have been identified and tested to optimize the cMUT frequency response, i.e. to increase the bandwidth, and to suppress parasitic disturbances linked to baffle effect in the electroacoustic response. The development of a dedicated cMUT array for the assessment of bone tissue is accurately detailed in the manuscript, including description of the design rules, fabrication steps and packaging procedure. An original characterization work has been carried out in order to check the device homogeneity, first from cell to cell and then from element to element. Finally, a comparison with a PZT probe with the same topology has been performed on bone mimicking phantom. Nice results has been obtained, showing that cMUT probe allows detecting higher number of guided modes in the cortical shell, and consequently, improving the cortical bone assessment.

Page generated in 0.1034 seconds