Spelling suggestions: "subject:"curva dde polarização"" "subject:"curva dee polarização""
1 |
Aparências metalográficas e corrosão seletiva de fases de aços inoxidáveis fundidos austenítico e martensítico atacados potenciostaticamente / Metallographic appearances and selective corrosion of phases of austenitic and martensitic cast stainless steels potentiostatically etchedSouza, Solange de 01 October 1997 (has links)
A corrosão seletiva de fases de dois tipos de aços inoxidáveis fundidos foi analisada, ao serem submetidos a vários valores constantes de potencial, a partir da região catódica para a anódica da curva de polarização. Os aços estudados foram: austenítico (ACI CF-3M) solubilizado e martensítico (ACI CA-6NM) normalizado e revenido. As curvas de polarização foram traçadas potenciodinamicamente, a uma velocidade de varredura de 0,16 m.V.s-1 em solução aerada contendo H2SO4 1M e NaCl 1M, pH 0,35, à temperatura ambiente. Vários valores de potencial foram selecionados, previamente localizados nas regiões catódica, ativa, passiva e transpassiva da curva de polarização. Potenciostaticamente, foram atingidos os valores de potencial selecionados, sendo eles mantidos fixos por 1800 s. Após o ataque potenciostático, as aparências metalográficas dos aços foram verificadas, desde a região catódica até a anódica. Por microssonda eletrônica, foram quantificados os elementos químicos presentes nas fases dos aços. Para melhor avaliar o início de propagação de pite, foi determinada a porcentagem de íons liberados para o eletrólito, após a imposição de valores de potencial críticos de pite predeterminados pelas curvas de polarização, pelas aparências metalográficas e pelas curvas de densidade de corrente em função do tempo. / The selective corrosion of phases present in two types of cast stainless steels was analyzed, when submitled to several constant values of potential, starting from the cathodic to the anodic regions of the polarization curve. The cast stainless steels were: austenitic (ACI CF-3M) solubilized and martensitic (ACI CA-6NM) normalized and tempered. The polarization curves were obtained at a scanning rate of 0.16 mV.s-1 in 1M H2S04 and 1M NaCI solution, pH 0.35 and at room temperature. Several potential values were selected, previously located in the cathodic, active, passive and transpassive regions of the polarization curve. The values of the selected potential were maintained fixed for 1800 s. After the potentiostatic etching, the metallographic appearances of the steels were verified, from the cathodic to the anodic region. Through electronic microprobe analysis, the present chemical elements were quantified in the phases of the steels. For betler evaluating the beginning of pitling propagation in the studied steels, liberated ion percentage for the solution was determined, after the imposition of critic pitting potential values predetermined from the polarization curves, through the metallographic appearances obtained after potentiostatic etching of the samples and the current density curves as a function of time.
|
2 |
Estudo de uma célula a combustível hidrogênio/ar de 1 kW de eletrólito membrana polimérica. / Study of a hydrogen / air fuel cell of 1 kW electrolyte polymer membrane.NASCIMENTO, Aldreany Pereira do. 15 March 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-03-15T16:40:52Z
No. of bitstreams: 1
ALDREANY PEREIRA DO NASCIMENTO - DISSERTAÇÃO PPGEQ 2016..pdf: 4384493 bytes, checksum: 8cf20c9f79749f12b562389c82ec5d3f (MD5) / Made available in DSpace on 2018-03-15T16:40:52Z (GMT). No. of bitstreams: 1
ALDREANY PEREIRA DO NASCIMENTO - DISSERTAÇÃO PPGEQ 2016..pdf: 4384493 bytes, checksum: 8cf20c9f79749f12b562389c82ec5d3f (MD5)
Previous issue date: 2016-10-30 / Capes / A crise do petróleo juntamente com a grande necessidade de novas fontes de
energias sustentáveis leva ao desenvolvimento de tecnologias mais limpas e
eficientes. Neste contexto, as células a combustível aparecem como uma das
soluções promissoras para a geração de energia elétrica, tendo como produto
da reação, basicamente água e calor. Este trabalho de dissertação consiste na
caracterização de uma célula a combustível PEM (Polymer Electrolyte
Membrane) alimentada com hidrogênio e ar para a conversão de energia elétrica
da energia química contida no gás hidrogênio. A célula a combustível utilizada é
de potência nominal de 1 kW, constituída por 72 células ligadas em série com
um sistema de controle próprio. A caracterização é feita através da utilização de
uma carga resistiva configurável com base num microcontrolador. A partir dos
parâmetros registrados (corrente e tensão), a curva de polarização, a densidade
de corrente e a eficiência foram calculadas com base nos sistemas de curto
circuito ligado e desligado (SCU: ON e SCU: OFF, respectivamente). Os
resultados mostram uma potência máxima de saída de aproximadamente 623 W
(37,09 V, 16,78 A), e uma densidade de corrente de 209,75 mA/cm2, com uma
eficiência operacional em torno de 42 %, com o sistema de SCU: OFF. Para o
sistema SCU: ON a potência máxima de saída é em torno de 664 W (39,10 V,
17,81 A) com densidade de corrente de 222,62 mA/cm2 e uma eficiência
operacional de 44 %. O sistema de carga variável mostrou-se satisfatório para
testar a célula, com um desvio entre a potência nominal e a real inferior a 20 %.
Os relativamente baixos valores de eficiência do sistema (<20 %) são explicados
pelo tempo de vida da célula. / The use of new sustainable energy sources is dependent on the development of
clearer and more efficient technologies. Therefore, the fuel cells appear like a
promising solution for the electrical energy generation, since that the reaction
products are water and heat. This work plans to characterize a polymer
electrolyte membrane fuel cell, feeding with hydrogen and air. The tested 1 kW
nominal power fuel cell is constituted by 72 cells connected in serial. The
characterization is made using a variable resistive charge system. It comprises
64 resistors (20 W) together with blowers for cooling. From the electrical
parameters (voltage and current), the polarization curve, the current density and
the efficiency of the fuel cell were calculated, with the short-circuit system on and
off (SCU: ON and SCU: OFF). A maximum output power of 623 W (37.09 V and
16.78 A), with a current density of approx. 209.75 mA/cm2 and an efficiency
around 42 % are obtained when the SCU is OFF. With the SCU: ON, the values
are 664 W (39.10 V and 17.81 A), 222.62 mA/cm2 and 44 %, respectively. The
results show that the resistive charge system is appropriate to test this kind of
fuel cell. The low global efficiency values (< 20 %) can be explained by the fuel
cell age.
|
3 |
Aparências metalográficas e corrosão seletiva de fases de aços inoxidáveis fundidos austenítico e martensítico atacados potenciostaticamente / Metallographic appearances and selective corrosion of phases of austenitic and martensitic cast stainless steels potentiostatically etchedSolange de Souza 01 October 1997 (has links)
A corrosão seletiva de fases de dois tipos de aços inoxidáveis fundidos foi analisada, ao serem submetidos a vários valores constantes de potencial, a partir da região catódica para a anódica da curva de polarização. Os aços estudados foram: austenítico (ACI CF-3M) solubilizado e martensítico (ACI CA-6NM) normalizado e revenido. As curvas de polarização foram traçadas potenciodinamicamente, a uma velocidade de varredura de 0,16 m.V.s-1 em solução aerada contendo H2SO4 1M e NaCl 1M, pH 0,35, à temperatura ambiente. Vários valores de potencial foram selecionados, previamente localizados nas regiões catódica, ativa, passiva e transpassiva da curva de polarização. Potenciostaticamente, foram atingidos os valores de potencial selecionados, sendo eles mantidos fixos por 1800 s. Após o ataque potenciostático, as aparências metalográficas dos aços foram verificadas, desde a região catódica até a anódica. Por microssonda eletrônica, foram quantificados os elementos químicos presentes nas fases dos aços. Para melhor avaliar o início de propagação de pite, foi determinada a porcentagem de íons liberados para o eletrólito, após a imposição de valores de potencial críticos de pite predeterminados pelas curvas de polarização, pelas aparências metalográficas e pelas curvas de densidade de corrente em função do tempo. / The selective corrosion of phases present in two types of cast stainless steels was analyzed, when submitled to several constant values of potential, starting from the cathodic to the anodic regions of the polarization curve. The cast stainless steels were: austenitic (ACI CF-3M) solubilized and martensitic (ACI CA-6NM) normalized and tempered. The polarization curves were obtained at a scanning rate of 0.16 mV.s-1 in 1M H2S04 and 1M NaCI solution, pH 0.35 and at room temperature. Several potential values were selected, previously located in the cathodic, active, passive and transpassive regions of the polarization curve. The values of the selected potential were maintained fixed for 1800 s. After the potentiostatic etching, the metallographic appearances of the steels were verified, from the cathodic to the anodic region. Through electronic microprobe analysis, the present chemical elements were quantified in the phases of the steels. For betler evaluating the beginning of pitling propagation in the studied steels, liberated ion percentage for the solution was determined, after the imposition of critic pitting potential values predetermined from the polarization curves, through the metallographic appearances obtained after potentiostatic etching of the samples and the current density curves as a function of time.
|
4 |
Propriedades de corrosão e caracterização química – metalográfica de próteses em aços inoxidáveis ISO 5832-9 e F138, removidas de pacientesSilva, Elison da Fonseca e 26 November 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-03T13:18:17Z
No. of bitstreams: 1
elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-13T13:33:58Z (GMT) No. of bitstreams: 1
elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Made available in DSpace on 2017-05-13T13:33:58Z (GMT). No. of bitstreams: 1
elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5)
Previous issue date: 2010-11-26 / Este trabalho estudou a composição química e metalográfica (microestrutura, tamanho
de grão, teor de inclusões) de aços inoxidáveis austeníticos, desenvolvidos para aplicações
como biomateriais, utilizados na fabricação de implantes ortopédicos, removidos de pacientes
afetados por quadro inflamatório, e comparou as superfícies das amostras, através da
Microscopia Eletrônica de Varredura (MEV) após ataque eletroquímico. Os resultados da
análise química, por Espectrometria de Emissão Ótica e Microanálise por Dispersão de
Energia (EDS), mostraram que todos os grupos apresentaram conformidade com as normas
ASTM F138-92 e ABNT NBR ISO 5832-9:2008. O tamanho de grão foi determinado por
Microscopia Ótica e Microscopia Eletrônica de Varredura (MEV). As superfícies das
amostras foram analisadas por Microscopia Eletrônica de Varredura (MEV), depois de serem
submetidos a ensaio de polarização cíclica potenciodinâmica em potencial de 50 mV após a
região passiva em meio de solução de Ringer Lactato e solução de NaCl 0,9 mol.L-1na
temperatura de 36,5 oC. Essas análises por MEV foram conduzidas nas amostras para
identificar o tipo de corrosão apresentada.
Concluiu-se que todos os implantes apresentavam tamanho de grão superior ao
recomendado pela norma. Constatou-se também a presença de ferrita delta em oito dos doze
implantes removidos, que de acordo com a norma ASTM 138-92, não deveria ser percebida
microscopicamente com um aumento de 100 vezes. Verificou-se ainda que em meio de NaCl,
o aço ISO 5832-9 ao contrário do aço F138, não apresentou nenhuma forma de corrosão
localizada. Em solução de Ringer lactato, após ataque por 15 min. no potencial de 1000
mV/ECS foi notada a presença de pites no aço ISO 5832-9.
O ensaio de polarização cíclica revelou que um dos aços, identificado como ISO 5832
9 apresentou resistência à corrosão localizada muito superior ao outro identificado como F
138, além de não liberar íons metálicos nas soluções eletrolíticas. Essa propriedade é
principalmente atribuída ao aumento da estabilidade do filme passivo, que por sua vez, é
favorecida pela presença do nitrogênio em solução sólida intersticial na austenita do aço ISO
5832-9. Os ensaios de polarização revelaram-se úteis para indicar a baixa resistência à
corrosão por pites exibida “in-vitro” pelas próteses.
As amostras do aço F 138 após serem submetidas ao ensaio eletroquímico em solução
de Ringer lactato apresentaram perdas de 63% de níquel e 26% de ferro em relação à
composição inicial. Tais elementos foram deslocados eletroquimicamente na forma iônica
para a solução de Ringer lactato, onde formaram precipitados sendo, portanto, um forte
indicador de que as reações sofridas pelos portadores das próteses foram motivadas por esses
íons metálicos, que são posteriormente incorporados no organismo.
Pretende-se com os resultados dessa pesquisa propor aos órgãos governamentais
reguladores de normas técnicas e de vigilância sanitária, bem como a médicos e hospitais que
exijam dos fabricantes de próteses de aços inoxidáveis laudos técnicos que atestem a
qualidade dos implantes, onde cada lote de fabricação das peças seja acompanhado por
certificados garantindo a composição química e as características metalográficas especificadas
pelas norma existentes no Brasil. / This work has studied the chemical and metallographic composition (microstructure,
grain size, inclusion rate) of austenitic stainless steels which were developed to be applied as
biomaterials, and used in the production of orthopedical implants, removed from patients
which had been affected by inflammation; it has also been compared the sample surfaces, by
means of scanning electronic microscopy (SEM) after electrochemical attack. The results of
chemical analysis, performed by optical emission spectroscopy and Energy Dispersive
Spectroscopy (EDS) have shown that all samples are in agreement with the ASTM F138-92 e
ABNT NBR ISO 5832-9:2008 regulations, whereas the grain size has been determined by
optical microscopy and SEM. The surfaces of the samples were analyzed by SEM and EDS
techniques; samples were submitted to potentiodynamic cyclic polarization tests in 50 mV
potential after the passivation region in Ringer lactate and NaCl 0,9 mol.L-1 solutions at
36,5C; such SEM measurements were done to identify the type of corrosion over the
samples.
It has been concluded that all implants showed average grain sizes above the
recommended by the regulations; also the presence of delta ferrite in eight of the twelve
investigated implants has been seen, which according to the ASTM 138-92 regulation this
would not been possible even with a 100-fold increase at the optical microscope. It has also
been verified that in NaCl medium the ISO 5832-9 steel did not present any kind of localized
corrosion, instead of F 138 steel; in Ringer lactate solution, after 15 minutes attack at
1000mV/SCE, has been noted the presence of pits for ISO 5832-9 steel.
The cyclic polarization measurements have revealed that one of the investigated steels,
named ISO 5832-9, presented a very high resistance to localized corrosion when compared to
the F 138 samples, besides they did not release metallic ions to the electrolytic solutions. This
characteristic can be mainly attributed to the increasing of the passivation film stability, which
is also favored by the presence of nitrogen atoms in the solid solution composing the structure
of ISO 5832-9 steel. The pit corrosion tests have shown very useful to indicate the low
resistance to pit corrosion, present “in-vitro” in all the studied samples. The EDS mapping
analysis of F 138 samples, submitted to electrochemical attack in Ringer lactate medium, have
shown a loss of 63% of nickel and 26% of iron, when compared to the initial composition;
such metals were electrochemically solubilized to the Ringer lactate solution, where they can
probably precipitate from the solution, being a strong indication that the reactions taking place
in the patients have been motivated by these metal ions, which can be incorporated by the
human body.
The obtained results of this work are the basis of a tentative proposition to the
governmental organisms which are the responsible for the regulation of the technical
specifications for the prosthesis producers, requiring from them technical reports assuring the
quality for the implant pieces, i.e., for each manufacturing lot a description or a special
certificate containing the chemical composition and the metallographic characteristics
specified by the Brazilian laws.
|
Page generated in 0.0851 seconds