• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Transdutores de ultrassom multielementos lineares flexíveis com sensor de curvatura para superfícies curvas. / Flexible linear array transducer with curvature sensor for curved surfaces.

Oliveira, Timóteo Francisco de 26 February 2015 (has links)
Os equipamentos de imagens por ultrassom com varredura eletrônica usam transdutores que não se moldam à superfície a ser examinada, pois são rígidos. Há transdutores com curvaturas fixas para aplicações específicas. Em aplicações médicas, esse não é um problema na maioria dos casos, pois os tecidos do corpo humano tomam a forma da face do transdutor. Isso não ocorre quando há estruturas ósseas próximas às camadas externas de tecidos moles. Nas aplicações industriais as superfícies são sólidas e, portanto, não se ajustam à superfície do transdutor, sendo necessário uma camada variável de acoplamento acústico. A possibilidade de uso de um transdutor flexível exige que sua curvatura seja conhecida para o direcionamento correto do feixe acústico usado na formação de imagens. Assim sendo, um transdutor multielemento flexível apresentaria a vantagem de poder ser acoplado na superfície curva diretamente, tanto em aplicações médicas quanto industriais. Os transdutores flexíveis relatados na literatura científica não são compactos e dispõe de complicados sistemas de sensoriamento usados na determinação de curvaturas, além de demandar por sofisticados sistemas de aquisição e processamento dos sinais. Este trabalho propõe o desenvolvimento de transdutores multielementos flexíveis compactos para serem acoplados diretamente em superfícies curvas de peças mecânicas ou do corpo humano. Neste trabalho os sensores de curvatura responsáveis pela medição da curvatura foram desenvolvidos segundo os princípios básicos de extensômetria e resistência dos materiais para serem embebidos nas camadas do transdutor flexível de ultrassom. No desenvolvimento, foram fabricadas quatro versões de transdutores, com frequências de 1 e 2,25MHz. Todos os materiais usados na fabricação dos protótipos foram especificados segundo suas propriedades mecânicas e acústicas. Os protótipos fabricados foram caracterizados tendo sido medidas a largura de banda de cada elemento do transdutor, o comprimento e a duração dos pulsos, e uma medida da resolução axial. Para o protótipo de 2,25MHz, uma medida estimada da resolução lateral foi feita pela simulação do campo acústico, considerando o transdutor curvado em uma superfície cilíndrica. Para se testar o desempenho dos protótipos, foram realizados diferentes testes de formação de imagem. A versão de transdutor flexível de 1MHz e sem sensor de curvatura foi curvado sobre um cilindro e imerso em um tanque com água para a realização de testes de formação de imagem usado na detecção de objetos e obstáculos. Para as versões de transdutores médicos com sensor de curvatura, construiu-se duas versões de phantom simulando uma interface óssea cortical densa dentro de um tecido mole humano. O phantom usado para testar o protótipo de 2,25MHz foi concebido por uma amostra de tíbia bovina fraturada embebida dentro de um material com propriedades acústicas muito próximas a da água. Os testes de imagem foram realizados com o transdutor de 2,25MHz curvado sobre a superfície cilíndrica do phantom. As imagens de ultrassom das regiões fraturadas do osso foram detectadas, e uma comparação entre as técnicas de varredura setorial e STA usadas na obtenção das imagens foram feitas. Mostrou-se que é possível fabricar, de uma forma simples, transdutores multielementos flexíveis mais compactos e dotados de sensor de curvatura, e sem a necessidade de se usar tecnologias sofisticadas e caras ou de se valer de sistemas complexos de formação e processamento de sinais. As imagens obtidas pelos protótipos mostraram que os protótipos podem ser usados em diferentes aplicações NDT na indústria. Em especial, o protótipo de 2,25MHz mostrou ainda que tem potencial no uso médico para a obtenção de imagens de fraturas em contornos ósseos mais densos. / Ultrasound image equipment with electronic scanning considers that transducers cannot take the shape of the surface to be examined because they are rigid. There are transducers with fixed curvatures for specific applications. In medical applications, this is not a serious problem in most cases, since the face of the transducer can be coupled to the soft tissues of the body. This does not occur when there are bone structures close to the external layers of soft tissue. In industrial applications, the surfaces are solid and therefore do not fit to the transducer surface, where a variable layer of acoustic coupling is necessary. The possibility of using a flexible transducer requires its curvature to be known in order to the correct the direction of the acoustic beam which will be used in imaging applications. Thus, a flexible array transducer would have the advantage of being directly coupled to the curved surface in medical and in industrial applications. Flexible ultrasound transducers reported in the scientific literature are not compact, having complex sensing systems used to determine curvature; furthermore, they require sophisticated signal acquisition and processing systems. The development of flexible compact ultrasound linear array transducers to be coupled directly onto curved surfaces of mechanical parts as well of the human body is proposed here. The bend sensors responsible for measuring the curvature were developed according to the basic principles of strain gauge in extensometry and strength of materials to be embedded in the layers of the flexible ultrasound transducer. During this development, four versions of transducers were manufactured, with frequencies of 1 and 2.25MHz. All the materials used in the prototypes manufacturing were selected based on their mechanical and acoustic properties. The manufactured prototypes were characterized in terms of measured parameters, such as the bandwidth of each transducer element, the length and duration of the pulses, and a measure of axial resolution. For the 2.25MHz prototype, the value of the lateral resolution was estimated by simulating the acoustic field considering the transducer curved over a cylindrical surface. In order to test the transducer prototypes, different ultrasound imaging tests were conducted. The 1MHz flexible transducer version without curvature sensor was bent over a cylinder and immersed in a water tank for performing image formation tests used to detect objects and obstacles. For the medical transducers version with curvature sensor, two versions of phantoms were constructed simulating a dense cortical bone interface located inside the soft human tissue. The phantom applied to test the 2.25 MHz prototype consists of a fractured sample of bovine tibia which was embedded within a material having acoustic properties very close to that of the water. Ultrasound imaging tests were performed with the 2.25MHz transducer curved over the cylindrical surface of the phantom. The regions of the fractured bone were detected in the ultrasound images, and a comparison between the STA and sector scanning techniques used for obtaining the images was made. The study showed that it is possible to manufacture flexible and more compact array transducers provided with curvature sensor, without the need of using sophisticated and expensive technologies or taking advantage of complex formation and signal processing systems. The images obtained by the prototypes showed that they can be employed in different NDT applications in the industry. Particularly, the 2.25MHz prototype also showed its potential for medical imaging fractures in dense bone contours.
2

Transdutores de ultrassom multielementos lineares flexíveis com sensor de curvatura para superfícies curvas. / Flexible linear array transducer with curvature sensor for curved surfaces.

Timóteo Francisco de Oliveira 26 February 2015 (has links)
Os equipamentos de imagens por ultrassom com varredura eletrônica usam transdutores que não se moldam à superfície a ser examinada, pois são rígidos. Há transdutores com curvaturas fixas para aplicações específicas. Em aplicações médicas, esse não é um problema na maioria dos casos, pois os tecidos do corpo humano tomam a forma da face do transdutor. Isso não ocorre quando há estruturas ósseas próximas às camadas externas de tecidos moles. Nas aplicações industriais as superfícies são sólidas e, portanto, não se ajustam à superfície do transdutor, sendo necessário uma camada variável de acoplamento acústico. A possibilidade de uso de um transdutor flexível exige que sua curvatura seja conhecida para o direcionamento correto do feixe acústico usado na formação de imagens. Assim sendo, um transdutor multielemento flexível apresentaria a vantagem de poder ser acoplado na superfície curva diretamente, tanto em aplicações médicas quanto industriais. Os transdutores flexíveis relatados na literatura científica não são compactos e dispõe de complicados sistemas de sensoriamento usados na determinação de curvaturas, além de demandar por sofisticados sistemas de aquisição e processamento dos sinais. Este trabalho propõe o desenvolvimento de transdutores multielementos flexíveis compactos para serem acoplados diretamente em superfícies curvas de peças mecânicas ou do corpo humano. Neste trabalho os sensores de curvatura responsáveis pela medição da curvatura foram desenvolvidos segundo os princípios básicos de extensômetria e resistência dos materiais para serem embebidos nas camadas do transdutor flexível de ultrassom. No desenvolvimento, foram fabricadas quatro versões de transdutores, com frequências de 1 e 2,25MHz. Todos os materiais usados na fabricação dos protótipos foram especificados segundo suas propriedades mecânicas e acústicas. Os protótipos fabricados foram caracterizados tendo sido medidas a largura de banda de cada elemento do transdutor, o comprimento e a duração dos pulsos, e uma medida da resolução axial. Para o protótipo de 2,25MHz, uma medida estimada da resolução lateral foi feita pela simulação do campo acústico, considerando o transdutor curvado em uma superfície cilíndrica. Para se testar o desempenho dos protótipos, foram realizados diferentes testes de formação de imagem. A versão de transdutor flexível de 1MHz e sem sensor de curvatura foi curvado sobre um cilindro e imerso em um tanque com água para a realização de testes de formação de imagem usado na detecção de objetos e obstáculos. Para as versões de transdutores médicos com sensor de curvatura, construiu-se duas versões de phantom simulando uma interface óssea cortical densa dentro de um tecido mole humano. O phantom usado para testar o protótipo de 2,25MHz foi concebido por uma amostra de tíbia bovina fraturada embebida dentro de um material com propriedades acústicas muito próximas a da água. Os testes de imagem foram realizados com o transdutor de 2,25MHz curvado sobre a superfície cilíndrica do phantom. As imagens de ultrassom das regiões fraturadas do osso foram detectadas, e uma comparação entre as técnicas de varredura setorial e STA usadas na obtenção das imagens foram feitas. Mostrou-se que é possível fabricar, de uma forma simples, transdutores multielementos flexíveis mais compactos e dotados de sensor de curvatura, e sem a necessidade de se usar tecnologias sofisticadas e caras ou de se valer de sistemas complexos de formação e processamento de sinais. As imagens obtidas pelos protótipos mostraram que os protótipos podem ser usados em diferentes aplicações NDT na indústria. Em especial, o protótipo de 2,25MHz mostrou ainda que tem potencial no uso médico para a obtenção de imagens de fraturas em contornos ósseos mais densos. / Ultrasound image equipment with electronic scanning considers that transducers cannot take the shape of the surface to be examined because they are rigid. There are transducers with fixed curvatures for specific applications. In medical applications, this is not a serious problem in most cases, since the face of the transducer can be coupled to the soft tissues of the body. This does not occur when there are bone structures close to the external layers of soft tissue. In industrial applications, the surfaces are solid and therefore do not fit to the transducer surface, where a variable layer of acoustic coupling is necessary. The possibility of using a flexible transducer requires its curvature to be known in order to the correct the direction of the acoustic beam which will be used in imaging applications. Thus, a flexible array transducer would have the advantage of being directly coupled to the curved surface in medical and in industrial applications. Flexible ultrasound transducers reported in the scientific literature are not compact, having complex sensing systems used to determine curvature; furthermore, they require sophisticated signal acquisition and processing systems. The development of flexible compact ultrasound linear array transducers to be coupled directly onto curved surfaces of mechanical parts as well of the human body is proposed here. The bend sensors responsible for measuring the curvature were developed according to the basic principles of strain gauge in extensometry and strength of materials to be embedded in the layers of the flexible ultrasound transducer. During this development, four versions of transducers were manufactured, with frequencies of 1 and 2.25MHz. All the materials used in the prototypes manufacturing were selected based on their mechanical and acoustic properties. The manufactured prototypes were characterized in terms of measured parameters, such as the bandwidth of each transducer element, the length and duration of the pulses, and a measure of axial resolution. For the 2.25MHz prototype, the value of the lateral resolution was estimated by simulating the acoustic field considering the transducer curved over a cylindrical surface. In order to test the transducer prototypes, different ultrasound imaging tests were conducted. The 1MHz flexible transducer version without curvature sensor was bent over a cylinder and immersed in a water tank for performing image formation tests used to detect objects and obstacles. For the medical transducers version with curvature sensor, two versions of phantoms were constructed simulating a dense cortical bone interface located inside the soft human tissue. The phantom applied to test the 2.25 MHz prototype consists of a fractured sample of bovine tibia which was embedded within a material having acoustic properties very close to that of the water. Ultrasound imaging tests were performed with the 2.25MHz transducer curved over the cylindrical surface of the phantom. The regions of the fractured bone were detected in the ultrasound images, and a comparison between the STA and sector scanning techniques used for obtaining the images was made. The study showed that it is possible to manufacture flexible and more compact array transducers provided with curvature sensor, without the need of using sophisticated and expensive technologies or taking advantage of complex formation and signal processing systems. The images obtained by the prototypes showed that they can be employed in different NDT applications in the industry. Particularly, the 2.25MHz prototype also showed its potential for medical imaging fractures in dense bone contours.
3

Optimization Of Zonal Wavefront Estimation And Curvature Measurements

Zou, Weiyao 01 January 2007 (has links)
Optical testing in adverse environments, ophthalmology and applications where characterization by curvature is leveraged all have a common goal: accurately estimate wavefront shape. This dissertation investigates wavefront sensing techniques as applied to optical testing based on gradient and curvature measurements. Wavefront sensing involves the ability to accurately estimate shape over any aperture geometry, which requires establishing a sampling grid and estimation scheme, quantifying estimation errors caused by measurement noise propagation, and designing an instrument with sufficient accuracy and sensitivity for the application. Starting with gradient-based wavefront sensing, a zonal least-squares wavefront estimation algorithm for any irregular pupil shape and size is presented, for which the normal matrix equation sets share a pre-defined matrix. A Gerchberg–Saxton iterative method is employed to reduce the deviation errors in the estimated wavefront caused by the pre-defined matrix across discontinuous boundary. The results show that the RMS deviation error of the estimated wavefront from the original wavefront can be less than λ/130~ λ/150 (for λ equals 632.8nm) after about twelve iterations and less than λ/100 after as few as four iterations. The presented approach to handling irregular pupil shapes applies equally well to wavefront estimation from curvature data. A defining characteristic for a wavefront estimation algorithm is its error propagation behavior. The error propagation coefficient can be formulated as a function of the eigenvalues of the wavefront estimation-related matrices, and such functions are established for each of the basic estimation geometries (i.e. Fried, Hudgin and Southwell) with a serial numbering scheme, where a square sampling grid array is sequentially indexed row by row. The results show that with the wavefront piston-value fixed, the odd-number grid sizes yield lower error propagation than the even-number grid sizes for all geometries. The Fried geometry either allows sub-sized wavefront estimations within the testing domain or yields a two-rank deficient estimation matrix over the full aperture; but the latter usually suffers from high error propagation and the waffle mode problem. Hudgin geometry offers an error propagator between those of the Southwell and the Fried geometries. For both wavefront gradient-based and wavefront difference-based estimations, the Southwell geometry is shown to offer the lowest error propagation with the minimum-norm least-squares solution. Noll’s theoretical result, which was extensively used as a reference in the previous literature for error propagation estimate, corresponds to the Southwell geometry with an odd-number grid size. For curvature-based wavefront sensing, a concept for a differential Shack-Hartmann (DSH) curvature sensor is proposed. This curvature sensor is derived from the basic Shack-Hartmann sensor with the collimated beam split into three output channels, along each of which a lenslet array is located. Three Hartmann grid arrays are generated by three lenslet arrays. Two of the lenslets shear in two perpendicular directions relative to the third one. By quantitatively comparing the Shack-Hartmann grid coordinates of the three channels, the differentials of the wavefront slope at each Shack-Hartmann grid point can be obtained, so the Laplacian curvatures and twist terms will be available. The acquisition of the twist terms using a Hartmann-based sensor allows us to uniquely determine the principal curvatures and directions more accurately than prior methods. Measurement of local curvatures as opposed to slopes is unique because curvature is intrinsic to the wavefront under test, and it is an absolute as opposed to a relative measurement. A zonal least-squares-based wavefront estimation algorithm was developed to estimate the wavefront shape from the Laplacian curvature data, and validated. An implementation of the DSH curvature sensor is proposed and an experimental system for this implementation was initiated. The DSH curvature sensor shares the important features of both the Shack-Hartmann slope sensor and Roddier’s curvature sensor. It is a two-dimensional parallel curvature sensor. Because it is a curvature sensor, it provides absolute measurements which are thus insensitive to vibrations, tip/tilts, and whole body movements. Because it is a two-dimensional sensor, it does not suffer from other sources of errors, such as scanning noise. Combined with sufficient sampling and a zonal wavefront estimation algorithm, both low and mid frequencies of the wavefront may be recovered. Notice that the DSH curvature sensor operates at the pupil of the system under test, therefore the difficulty associated with operation close to the caustic zone is avoided. Finally, the DSH-curvature-sensor-based wavefront estimation does not suffer from the 2π-ambiguity problem, so potentially both small and large aberrations may be measured.
4

Dispositivos em fibras ópticas baseados em interferência multimodal / Devices with optical fibres based on multimode interference

Pinilla Pachon, Edwin German, 1981- 03 May 2013 (has links)
Orientadores: Cristiano Monteiro de Barros Cordeiro, Marcos Antonio Ruggieri Franco / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-22T12:56:38Z (GMT). No. of bitstreams: 1 PinillaPachon_EdwinGerman_M.pdf: 12541930 bytes, checksum: 74a0367c344ded9c8891d11280568b6b (MD5) Previous issue date: 2013 / Resumo: Nesta dissertação se estudou por simulação numérica o efeito de interferência multimodal (MMI, do inglês "multimode interference") em guias de onda, com atenção especial a fibras ópticas, e a resposta óptica do dispositivo MMI a parâmetros externos como temperatura, curvatura e índice de refração. Dispositivos baseados em MMI são formados, em geral, por três guias de onda concatenados sendo as extremidades compostas de guias monomodo e a parte central composta de um guia que permite a propagação de muitos modos, tipicamente, mais do que três. Nesta situação, na seção multimodo, são formadas reimagens que aproximadamente replicam fase e amplitude do campo óptico de entrada. A observação do espectro de transmissão correspondente à primeira reimagem, em dispositivos MMI, permite desenvolver sensores de índice de refração, temperatura e curvatura. A sensibilidade dos sensores foi avaliada frente às variações do mensurando, ou seja, variações no índice de refração, temperatura e curvatura da estrutura MMI em fibra óptica. / Abstract: In this work the effect of multimodal interference (MMI) in waveguides was studied by numerical simulation. Special attention was given to optical fibers and its the optical response when external parameters such as temperature, curvature or refractive índex were varied. MMI devices are usually formed by connecting three waveguides being the input and output ones single mode waveguides while the middle one is a waveguide that allows the propagation of many optical modes, typically more than three. In this situation re-images that replicate both the phase and the amplitude of the input optical field are formed periodically within the multimode section. The analysis of the transmission spectrum of the first re-image in MMI devices were realized in order to get information about the fiber environment, in particular the surrounding refractive índex, radius of curvature and temperature. The sensors sensitivity was evaluated. / Mestrado / Física / Mestre em Física

Page generated in 0.0486 seconds