• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da sensibilidade cutânea em pacientes com síndrome do túnel do carpo relacionada à hemodiálise / Cutaneous sensibility testing in patients with hemodialysis- associated carpal tunnel syndrome.

Nakamoto, Hugo Alberto 28 August 2009 (has links)
A síndrome do túnel do carpo é a neuropatia compressiva mais comum do membro superior. Cerca de 5% dos pacientes com insuficiência renal crônica submetidos à hemodiálise apresentam esta condição. A história clínica e o exame físico continuam sendo as ferramentas mais adequadas para seu diagnóstico. Testes complementares têm sido usados para auxiliar o diagnóstico, dentre eles os de avaliação da sensibilidade cutânea. O objetivo deste estudo é descrever a utilização do PSSD (Pressure- specified sensory device ) como auxiliar ao diagnóstico de síndrome do túnel do carpo. O PSSD consiste de aparelho que incorpora transdutor de pressão com duas extremidades rombas e com regulagem de distância entre elas, acoplado a um computador capaz de determinar os limiares cutâneos de pressão. Para tanto, os pacientes foram divididos em três grupos: Grupo 1- grupo controle, pacientes sem neuropatia no membro superior ou insuficiência renal. Grupo 2- pacientes com síndrome do túnel do carpo e insuficiência renal crônica submetidos à hemodiálise. Grupo 3- pacientes com síndrome do túnel do carpo sem insuficiência renal. Os resultados demonstraram haver um maior benefício do uso do PSSD para o diagnóstico da síndrome para os pacientes do grupo 2 em dois dos quatro parâmetros avaliados quando comparados com os pacientes do grupo 3. / Carpal Tunnel Syndrome is the most common compressive neuropathy of the superior limb. Close to 5% of the patients with chronic renal insufficiency who need hemodialysis have carpal tunnel syndrome. There are controversies about the most reliable test to complement the clinical history and physical exam that remain as the most adequate tools for the diagnosis. Evaluation of sensory thresholds is being used as one of these tests. The aim of this study is to use the PSSD (Pressure-specified sensory device) for the diagnosis of carpal tunnel syndrome. The PSSD is a tool that incorporates a pressure transducer with two prongs, linked to a computer capable of measuring the cutaneous pressure thresholds referred by the patient. The patients were divided in three groups: Group 1- patients with neither superior limb neuropathy nor renal insufficiency. Group 2- patients with carpal tunnel syndrome related to chronic renal insufficiency under hemodialysis. Group 3- patients with carpal tunnel syndrome but no renal insufficiency. The results showed, for two of the four parameters measured, that group 2 had more benefits for the diagnosis of carpal tunnel syndrome than group 3.
2

Avaliação da sensibilidade cutânea em pacientes com síndrome do túnel do carpo relacionada à hemodiálise / Cutaneous sensibility testing in patients with hemodialysis- associated carpal tunnel syndrome.

Hugo Alberto Nakamoto 28 August 2009 (has links)
A síndrome do túnel do carpo é a neuropatia compressiva mais comum do membro superior. Cerca de 5% dos pacientes com insuficiência renal crônica submetidos à hemodiálise apresentam esta condição. A história clínica e o exame físico continuam sendo as ferramentas mais adequadas para seu diagnóstico. Testes complementares têm sido usados para auxiliar o diagnóstico, dentre eles os de avaliação da sensibilidade cutânea. O objetivo deste estudo é descrever a utilização do PSSD (Pressure- specified sensory device ) como auxiliar ao diagnóstico de síndrome do túnel do carpo. O PSSD consiste de aparelho que incorpora transdutor de pressão com duas extremidades rombas e com regulagem de distância entre elas, acoplado a um computador capaz de determinar os limiares cutâneos de pressão. Para tanto, os pacientes foram divididos em três grupos: Grupo 1- grupo controle, pacientes sem neuropatia no membro superior ou insuficiência renal. Grupo 2- pacientes com síndrome do túnel do carpo e insuficiência renal crônica submetidos à hemodiálise. Grupo 3- pacientes com síndrome do túnel do carpo sem insuficiência renal. Os resultados demonstraram haver um maior benefício do uso do PSSD para o diagnóstico da síndrome para os pacientes do grupo 2 em dois dos quatro parâmetros avaliados quando comparados com os pacientes do grupo 3. / Carpal Tunnel Syndrome is the most common compressive neuropathy of the superior limb. Close to 5% of the patients with chronic renal insufficiency who need hemodialysis have carpal tunnel syndrome. There are controversies about the most reliable test to complement the clinical history and physical exam that remain as the most adequate tools for the diagnosis. Evaluation of sensory thresholds is being used as one of these tests. The aim of this study is to use the PSSD (Pressure-specified sensory device) for the diagnosis of carpal tunnel syndrome. The PSSD is a tool that incorporates a pressure transducer with two prongs, linked to a computer capable of measuring the cutaneous pressure thresholds referred by the patient. The patients were divided in three groups: Group 1- patients with neither superior limb neuropathy nor renal insufficiency. Group 2- patients with carpal tunnel syndrome related to chronic renal insufficiency under hemodialysis. Group 3- patients with carpal tunnel syndrome but no renal insufficiency. The results showed, for two of the four parameters measured, that group 2 had more benefits for the diagnosis of carpal tunnel syndrome than group 3.
3

Avaliação da sensibilidade cutânea em pacientes com lesões agudas de nervos periféricos de membros superiores / Assessment the cutaneous sensibility in acute peripheral upper limb nerve trauma

Aguilera, Nelio Watanabe 10 November 2010 (has links)
A mão humana desempenha a função de um órgão sensorial de percepção, localização e discriminação `a estimulação cutânea. A injúria de nervos periféricos em membros superiores é uma condição com repercurssões funcionais e sociais graves pois, uma mão sem sensibilidade é usualmente uma mão sem função. O objetivo deste estudo é descrever a utilização do PSSD (Pressure- specified sensory device ) como auxiliar ao seguimento dos índices de recuperação da sensibilidade cutânea em pacientes submetidos a reconstruções microcirúrgicas de lesões traumáticas de nervos periféricos de membros superiores. O PSSD consiste de um aparelho que incorpora um transdutor de pressão com duas extremidades rombas e com regulagem de distância entre elas, acoplado a um computador capaz de determinar os limiares cutâneos de pressão para os parâmetros de 1 ponto estático, 1 ponto dinâmico e respectivos 2 pontos. No estudo, os pacientes foram divididos em três grupos: pacientes com lesões de n. mediano e/ou n. ulnar em nível do antebraço, punho e dedos. O teste estatístico utilizado para análise das comparações, tanto entre os grupos quanto para os diferentes momentos considerados de 1, 3, 6 e 12 meses foi a Análise de Variância (ANOVA) com Medidas Repetidas. Os resultados demonstraram haver interação entre os grupos onde, em média, houve diferença estatística (p<0,05) para os parâmetros considerados, a medida que, se aumenta o tempo de avaliação. As lesões digitais, para todos os parâmetros avaliados, apresentaram menores valores dos limiares cutâneos de pressão seguidos do punho e antebraço e não se evidenciou diferença estatística (p>0,05) entre os resultados dos limiares cutâneos de pressão nos nervos mediano e ulnar / The human hand has an important sensorial capacity to perceive, to localize and to distinguish simultaneously, in the act of touch. Peripheral nerve injury at upper limb have seriously functional and social disabilities: a hand without sensibility is usually a hand without function. This study has the purpose to use the PSSD (Pressure-specified sensory device) in patients submitted to microsurgical reconstructions of peripheral upper limb nerves to evaluate the cutaneous sensibility recovery. The PSSD is a tool that incorporates a pressure transducer with two prongs, linked to a computer capable of measuring the cutaneous pressure thresholds referred by the patient. In this study, the patients were divided in three groups: patients with median or ulnar nerve trauma at forearm, wrist or digital levels. The statistical analysis method used to compare the groups and considering different moments in the study of 1, 3, 6 and 12 months was the analysis of variance (ANOVA). The results demonstrate interaction between groups where the generalized mean showed statistical relevance for the parameters of the study as well as the time grows. The digital nerve injuries considering all parameters evaluated revealed the smaller values of cutaneous pressure thresholds followed by the results of the wrist and in the last the forearm cutaneous pressure thresholds values. There were no statistical significance between the median and the ulnar nerves considering the values of the cutaneous sensibility thresholds
4

Tactile Sensory Control of Dexterous Manipulation in Humans

Birznieks, Ingvars January 2003 (has links)
During dexterous manipulation with the fingertips, forces are applied to objects' surfaces. To achieve grasp stability, these forces must be appropriate given the properties of the objects and the skin of the fingertips, and the nature of the task. It has been demonstrated that tactile sensors in the fingertips provide crucial information about both object properties and mechanical events critical for the control of fingertip forces, while in certain tasks vision may also contribute to predictions of required fingertip actions. This thesis focuses on two specific aspects of the sensory control of manipulation: (i) how individual fingers are controlled for grasp stability when people restrain objects subjected to unpredictable forces tangential to the grasped surfaces, and (ii) how tactile sensors in the fingertips encode direction of fingertip forces and shape of surfaces contacted by the fingertips. When restraining objects with two fingers, subjects adjust the fingertip forces to the local friction at each digit-object interface for grasp stability. This is accomplished primarily by partitioning the tangential force between the digits in a way that reflects the local friction whereas the normal forces at the involved digits are scaled by the average friction and the total load. The neural control mechanisms in this task rely on tactile information pertaining to both the friction at each digit-object interface and the development of tangential load. Moreover, these mechanisms controlled the force application at individual digits while at the same time integrating sensory inputs from all digits involved in the task. Microneurographical recordings in awake humans shows that most SA-I, SA-II and FA-I sensors in the distal phalanx are excited when forces similar to those observed during actual manipulation are applied to the fingertip. Moreover, the direction of the fingertip force influences the impulse rates in most afferents and their responses are broadly tuned to a preferred direction. The preferred direction varies among the afferents and, accordingly, ensembles of afferents can encode the direction of fingertip forces. The local curvature of the object in contact with the fingertip also influenced the impulse rates in most afferents, providing a curvature contrast signals within the afferent populations. Marked interactions were observed in the afferents' responses to object curvature and force direction. Similar findings were obtained for the onset latency in individual afferents. Accordingly, for ensembles of afferents, the order by which individual afferents initially discharge to fingertip events effectively represents parameters of fingertip stimulation. This neural code probably represents the fastest possible code for transmission of parameters of fingertip stimuli to the CNS.
5

Avaliação da sensibilidade cutânea em pacientes com lesões agudas de nervos periféricos de membros superiores / Assessment the cutaneous sensibility in acute peripheral upper limb nerve trauma

Nelio Watanabe Aguilera 10 November 2010 (has links)
A mão humana desempenha a função de um órgão sensorial de percepção, localização e discriminação `a estimulação cutânea. A injúria de nervos periféricos em membros superiores é uma condição com repercurssões funcionais e sociais graves pois, uma mão sem sensibilidade é usualmente uma mão sem função. O objetivo deste estudo é descrever a utilização do PSSD (Pressure- specified sensory device ) como auxiliar ao seguimento dos índices de recuperação da sensibilidade cutânea em pacientes submetidos a reconstruções microcirúrgicas de lesões traumáticas de nervos periféricos de membros superiores. O PSSD consiste de um aparelho que incorpora um transdutor de pressão com duas extremidades rombas e com regulagem de distância entre elas, acoplado a um computador capaz de determinar os limiares cutâneos de pressão para os parâmetros de 1 ponto estático, 1 ponto dinâmico e respectivos 2 pontos. No estudo, os pacientes foram divididos em três grupos: pacientes com lesões de n. mediano e/ou n. ulnar em nível do antebraço, punho e dedos. O teste estatístico utilizado para análise das comparações, tanto entre os grupos quanto para os diferentes momentos considerados de 1, 3, 6 e 12 meses foi a Análise de Variância (ANOVA) com Medidas Repetidas. Os resultados demonstraram haver interação entre os grupos onde, em média, houve diferença estatística (p<0,05) para os parâmetros considerados, a medida que, se aumenta o tempo de avaliação. As lesões digitais, para todos os parâmetros avaliados, apresentaram menores valores dos limiares cutâneos de pressão seguidos do punho e antebraço e não se evidenciou diferença estatística (p>0,05) entre os resultados dos limiares cutâneos de pressão nos nervos mediano e ulnar / The human hand has an important sensorial capacity to perceive, to localize and to distinguish simultaneously, in the act of touch. Peripheral nerve injury at upper limb have seriously functional and social disabilities: a hand without sensibility is usually a hand without function. This study has the purpose to use the PSSD (Pressure-specified sensory device) in patients submitted to microsurgical reconstructions of peripheral upper limb nerves to evaluate the cutaneous sensibility recovery. The PSSD is a tool that incorporates a pressure transducer with two prongs, linked to a computer capable of measuring the cutaneous pressure thresholds referred by the patient. In this study, the patients were divided in three groups: patients with median or ulnar nerve trauma at forearm, wrist or digital levels. The statistical analysis method used to compare the groups and considering different moments in the study of 1, 3, 6 and 12 months was the analysis of variance (ANOVA). The results demonstrate interaction between groups where the generalized mean showed statistical relevance for the parameters of the study as well as the time grows. The digital nerve injuries considering all parameters evaluated revealed the smaller values of cutaneous pressure thresholds followed by the results of the wrist and in the last the forearm cutaneous pressure thresholds values. There were no statistical significance between the median and the ulnar nerves considering the values of the cutaneous sensibility thresholds

Page generated in 0.0936 seconds