• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efficacy of gelatin gel sheets in sustaining the release of basic fibroblast growth factor for murine skin defects / マウス皮膚欠損創モデルにおける塩基性線維芽細胞増殖因子(bFGF)徐放性ゼラチンゲルシートの有効性

Sakamoto, Michiharu 23 September 2016 (has links)
京都大学 / 0048 / 新制・論文博士 / 博士(医学) / 乙第13051号 / 論医博第2117号 / 新制||医||1017(附属図書館) / 33141 / (主査)教授 別所 和久, 教授 椛島 健治, 教授 開 祐司 / 学位規則第4条第2項該当 / Doctor of Medical Science / Kyoto University / DFAM
2

Relationships Between Skin Properties and Body Water Level / Förhållanden mellan hudegenskaper och kroppens vattennivå

Andersson, Ida, Hedvall, Anders January 2013 (has links)
A need for a quantitative method to determine body water level has been identified by a team of Clinical Innovation Fellows at the Centre for Technology in Medicine and Health (CTMH). A reliable way to determine body water level would bring great benefits to the healthcare sector, where no optimal method is available at the time of writing. A possible solution is a sensor that would measure alterations in skin properties due to changes in total body water. CTMH has had an idea of such a sensor, which is evaluated in this work. At an early stage of this evaluation process, it became clear that the research regarding correlations between skin properties and body hydration level was not sufficient to warrant the initiation of a sensor development process. Therefore, the main objective of this thesis became to investigate such correlations. An extensive literature review is presented, from which an experiment was developed. The experiment was performed on four human test subjects and involved measurements of skin thickness and elasticity parameters, before and after a weight loss of 3.2-3.7 % due to dehydration. The results showed clear decreases in skin thickness and indications of alterations in skin distensibility as well as in the skin’s immediate elastic response to applied negative pressure. It could also be seen that skin at different body sites does not respond in the same way - calves showed more distinct results than thighs and volar forearm. The material provided in this thesis encourages further studies of the correlation between the mentioned properties and total body water. If a predictable correlation can be found, a sensor development process could start. A reliable way to determine body water level would bring great benefits to the healthcare sector, where no optimal method is available at the time of writing. / Ett behov av att kvantitativt kunna mäta kroppens vattennivå har identifierats av Clinical Innovation Fellowship vid Centrum för Teknik i Medicin och Hälsa (CTMH). Ett tillförlitligt sätt att mäta kroppens vattennivå skulle gynna hälso- och sjukvården på många sätt då ingen optimal metod är tillgänglig i dagsläget. En möjlig lösning skulle kunna vara en sensor som mäter variationer i hudegenskaper till följd av förändringar i kroppens vattennivå. CTMH har haft en idé om en sådan sensor, vilken utvärderas i detta arbete. I ett tidigt skede av utvärderingsprocessen framkom det tydligt att tillräcklig forskning saknades gällande korrelationer mellan hudens egenskaper och kroppens vattennivå. Det huvudsakliga syftet med detta masterexamensarbete blev därför att undersöka sådana korrelationer. En omfattande litteraturgransking gjordes, och utifrån denna utformades ett experiment. Experimentet utfördes på fyra testpersoner och innefattade mätningar av hudens tjocklek samt elasticitetsparameterar. Dessa utfördes före och efter viktnedgång av 3,2-3,7 % till följd av vattenförlust. Resultaten visade på en tydlig minskning av hudtjockleken samt indikationer på förändringar av hudens tänjbarhet samt dess omedelbara elastiska respons vid pålagt negativt tryck. Det visade sig också att huden inte reagerar på samma sätt på olika kroppsdelar - vader visade tydligare förändringar jämfört med lår och armar. Det material som presenteras i detta examensarbete uppmuntrar till fortsatt utredning av korrelationer mellan de nämnda hudegenskaperna och kroppens vattennivå. Om det går att förutse korrelationer finns det förutsättningar för att påbörja utveckling av en sensor.

Page generated in 0.0623 seconds