• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avalia??o da qualidade de imagens adquiridas em c?mara dedicada a estudos card?acos com detectores de estado s?lido

Favero, Mariana Saibt 30 August 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-11-25T11:27:41Z No. of bitstreams: 1 DIS_MARIANA_SAIBT_FAVERO_COMPLETO.pdf: 3636118 bytes, checksum: 2c3042f7c1e83bede7896f413417764c (MD5) / Made available in DSpace on 2016-11-25T11:27:41Z (GMT). No. of bitstreams: 1 DIS_MARIANA_SAIBT_FAVERO_COMPLETO.pdf: 3636118 bytes, checksum: 2c3042f7c1e83bede7896f413417764c (MD5) Previous issue date: 2016-08-30 / Myocardial Perfusion Imaging (MPI) used in nuclear cardiology have been widely applied in clinical practice, because its value is documented in the diagnosis and prognosis of coronary artery disease. Due to the increasing use, the industry has developed projects for dedicated cardiac chambers that restrict the detection area just to the heart. Two detection systems for tomographic acquisitions in nuclear cardiology, using solid-state detectors, specifically cadmium zinc telluride crystals (CZT) are currently marketed. Although resulting in a short acquisition time and reduced radiation dose to the patient, there are doubts about the assessment procedures of equipment performance and the influence of the acquisition parameters and processing quality of the images. The aim of this study is to assess the impacts of changes in acquisition parameters and processing as cardiac SPECT equipment with solid and stationary gantry detectors. For this evaluation have been acquired images of an anthropomorphic experimental simulator with heart insert into a SPECT camera with solid state CZT detector type, to evaluate the quality and visibility of injuries. The images obtained were evaluated by quantitative quality indicators, such as the standard deviation normalization, contrast between the wall of the ventricle and the cavity, contrast-to-noise ratio and effective contrast of the lesion. As a result of the survey, variations in the time of acquisition does not affect the quality indicators values, unlike the reconstruction parameters and administered activity. The reconstruction parameter is what most affects the indicators, it is necessary to define a protocol of acquisition value for each activity to be administered in accordance with the characteristics of the patient. / Imagens de Perfus?o Mioc?rdica (MPI) usadas em cardiologia nuclear t?m sido amplamente aplicadas na pr?tica cl?nica, pois seu valor est? documentado no diagn?stico e progn?stico de doen?a arterial coronariana. Devido ao crescente uso, a ind?stria tem desenvolvido projetos para c?maras card?acas dedicadas que restringem a ?rea de detec??o apenas para o cora??o. Dois sistemas de detec??o para aquisi??es tomogr?ficas em cardiologia nuclear, utilizando detectores do estado s?lido, mais especificamente cristais de telureto de c?dmio e zinco (CZT) s?o comercializados atualmente. Apesar de resultarem em um curto tempo de aquisi??o e redu??o da dose de radia??o no paciente, existem d?vidas sobre os procedimentos de avalia??o do desempenho do equipamento e a influ?ncia dos par?metros de aquisi??o e processamento na qualidade das imagens. O objetivo desse trabalho ? avaliar os impactos de mudan?as de par?metros de aquisi??o e processamento na qualidade de imagens card?acas em equipamentos SPECT com detectores de estado s?lido e gantry estacion?rio. Para esta avalia??o foram adquiridas imagens de um simulador experimental antropom?rfico com inser??o card?aca em uma c?mara SPECT com detector de estado s?lido do tipo CZT, visando avaliar a qualidade e visibilidade de les?es. As imagens adquiridas foram avaliadas por meio de indicadores quantitativos de qualidade, como a normaliza??o do desvio padr?o, contraste entre a parede do ventr?culo e a cavidade, raz?o contraste-ru?do e contraste efetivo da les?o. Como resultado da pesquisa foi poss?vel observar que varia??es no tempo de aquisi??o n?o afetam os valores de indicadores de qualidade, diferentemente dos par?metros de reconstru??o e atividade administrada. O par?metro de reconstru??o ? o que mais afeta os indicadores, sendo necess?rio definir um protocolo de aquisi??o para cada valor de atividade a ser administrada de acordo com as caracter?sticas do paciente.
2

Investiga??o dos par?metros dependentes do paciente para a otimiza??o da atividade administrada em exames de PET/CT com 18F-FDG

Martini, J?lio C?sar 29 August 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-12-06T16:05:53Z No. of bitstreams: 1 DIS_JULIO_CESAR_MARTINI_COMPLETO.pdf: 2066306 bytes, checksum: ac62f8de7f443732c71f76471192afd6 (MD5) / Made available in DSpace on 2016-12-06T16:05:53Z (GMT). No. of bitstreams: 1 DIS_JULIO_CESAR_MARTINI_COMPLETO.pdf: 2066306 bytes, checksum: ac62f8de7f443732c71f76471192afd6 (MD5) Previous issue date: 2016-08-29 / Despite the activities administered to patients during Positron Emission Tomography (PET) scans are guided by methods and reference levels, in clinical practice there is a great discrepancy between these values. Current indications use dependent patient parameters (DPP), such as age and weight, without considering an assessment of the resulting image quality. The purpose of this study is to investigate how the anthropometric and physiological characteristics of patients influence the determination of 18F-FDG activity to be administered in PET/CT scans and image quality. Therefore, we conducted a preliminary study with three simulators of different diameters, representing patients with different sizes, with different values of activity concentration. Subsequently, we performed a retrospective study on a PET/CT image database acquired with 18F-FDG. Image quality indicators (NECR, and NECRN and SNRnorm) of the images of patients were determined for many PDP, namely: body weight, BMI, BSA, fat mass, mass-height ratio and equivalent diameter. The relationship between the administered activity, counts rates and the PDP, with image quality indicators were statistically evaluated. We concluded that the NECRN is the quality indicator which has the best correlation between the PDP, particularly with body mass and BMI. The image quality in can be estimated from the true coincidence events rate (TRUES) during PET/CT acquisition with 18F-FDG, due to the highly linear relationship with NECR for different body mass or BMI ranges, allowing the optimization of the administered activity based on the physical characteristics of the patient. / Apesar das atividades administradas a pacientes durante exames de Tomografia por Emiss?o de P?sitrons (PET) serem norteados por m?todos e n?veis de refer?ncia, na pr?tica cl?nica h? uma grande discrep?ncia entre esses valores. As indica??es atuais utilizam par?metros dependentes do paciente (PDP), como idade e peso, sem considerar uma avalia??o da qualidade da imagem obtida. A proposta deste trabalho ? investigar como as caracter?sticas antropom?tricas e fisiol?gicas dos pacientes influenciam na determina??o da atividade de 18F-FDG a ser administrada em exames de PET/CT e na qualidade das imagens. Para tanto, foi realizado um estudo preliminar com tr?s simuladores de diferentes di?metros, representando pacientes com tamanhos distintos, com valores distintos de concentra??o de atividade. Posteriormente, foi realizado um estudo retrospectivo em um banco de imagens de exames de PET/CT com 18F-FDG. Foram determinados indicadores de qualidade (NECR, NECRN e SNR) das imagens dos pacientes para diversos PDP, a saber: massa corporal, BMI, BSA, massa gorda, rela??o massa-altura e di?metro equivalente. Foram avaliadas estatisticamente as rela??es entre as atividades administradas, as taxas de contagens e os PDP, com os indicadores de qualidade da imagem. Conclui-se que a NECRN ? o indicador de qualidade que possui a melhor correla??o entre os PDP, particularmente com a massa corporal e o BMI. A qualidade da imagem pode ser estimada atrav?s da taxa de eventos de coincid?ncia verdadeira (TRUES) durante a aquisi??o das imagens de PET/CT com 18F-FDG, em virtude da rela??o altamente linear com o NECR para faixas distintas de massa corporal ou BMI, possibilitando a otimiza??o da atividade administrada em fun??o das caracter?sticas f?sicas do paciente.

Page generated in 0.0311 seconds