1 |
"Avaliação do transporte e cinética de solutos em pacientes submetidos à hemodiálise diária de alto fluxo, alta eficiência e curta duração" / Solutes transport and kinetics assessment in patientes submitted to a high flux, high efficiency and short length daily hemodialysisLuders, Claudio 30 August 2005 (has links)
Nos últimos anos, em função dos resultados negativos do HEMO Study e da elevada mortalidade na população dialítica, observou-se crescente interesse nosregimes de hemodiálise diária. A dose de diálise persiste como um dos elementos fundamentais na adequação do tratamento dialítico. Comparamos as doses de diálise em hemodiálise diária (90 minutos, 6 vezes / semana), com as doses em hemodiálise convencional (240 minutos, 3 vezes / semana), através da quantificação direta da diálise, do modelo de cinética de uréia e pelo Standard Kt/V de Gotch. A comparação foi feita para diferentes solutos (uréia, creatinina, fósforo, ácido úrico e ß2-microglobulina) e diferentes taxas de ultrafiltração / The recent efforts to improve dialysis outcome and the negative results from the HEMO Study have created great interest on alternative hemodialysis (HD) regimens. Dialysis dose persist fundamental to HD adequacy. However, parameters of adequacy have not been validated to Daily HD. We compared the dialysis dose of daily, high efficiency and flux HD (90 minutes, 6 times a week) with Conventional high flux HD (240 minutes, 3 times a week) by direct dialysis quantification, urea kinetics model and Gotch's stdKt/V. The comparison was made with urea, creatinine, phosphate, uric acid and ß2-microglobulin. We, also, analyzed the effect of different ultrafiltration rates on solute removal on Daily HD
|
2 |
"Avaliação do transporte e cinética de solutos em pacientes submetidos à hemodiálise diária de alto fluxo, alta eficiência e curta duração" / Solutes transport and kinetics assessment in patientes submitted to a high flux, high efficiency and short length daily hemodialysisClaudio Luders 30 August 2005 (has links)
Nos últimos anos, em função dos resultados negativos do HEMO Study e da elevada mortalidade na população dialítica, observou-se crescente interesse nosregimes de hemodiálise diária. A dose de diálise persiste como um dos elementos fundamentais na adequação do tratamento dialítico. Comparamos as doses de diálise em hemodiálise diária (90 minutos, 6 vezes / semana), com as doses em hemodiálise convencional (240 minutos, 3 vezes / semana), através da quantificação direta da diálise, do modelo de cinética de uréia e pelo Standard Kt/V de Gotch. A comparação foi feita para diferentes solutos (uréia, creatinina, fósforo, ácido úrico e ß2-microglobulina) e diferentes taxas de ultrafiltração / The recent efforts to improve dialysis outcome and the negative results from the HEMO Study have created great interest on alternative hemodialysis (HD) regimens. Dialysis dose persist fundamental to HD adequacy. However, parameters of adequacy have not been validated to Daily HD. We compared the dialysis dose of daily, high efficiency and flux HD (90 minutes, 6 times a week) with Conventional high flux HD (240 minutes, 3 times a week) by direct dialysis quantification, urea kinetics model and Gotch's stdKt/V. The comparison was made with urea, creatinine, phosphate, uric acid and ß2-microglobulin. We, also, analyzed the effect of different ultrafiltration rates on solute removal on Daily HD
|
3 |
"Levantamento da situação vacinal e avaliação sorológica para sarampo e varicela de crianças e adolescentes portadores de insuficiência renal crônica em tratamento conservador e dialítico" / Immunization status analysis and evaluation of antibody titers against measles and varicella in 83 chronic renal failure children and adolescents in conservative and dialytic therapyFagundes, Simone Nascimento 26 January 2004 (has links)
A infecção é causa de morbimortalidade no paciente com insuficiência renal crônica (IRC), facilitada pela uremia, que leva a resposta imune insuficiente, inclusive após a vacinação. Foram avaliadas a situação vacinal e a presença de anticorpos para sarampo e varicela, de 83 crianças e adolescentes com IRC. A adesão dos pacientes às vacinas foi BCG 100%, poliomielite 98,8%, DPT 97,6%, sarampo monovalente 96,4%, tríplice viral 88%, hepatite B 68,7%. Ausência de anticorpos para sarampo e varicela ocorreu em 14,5% e 26,5% dos pacientes. A susceptibilidade ao sarampo em vacinados, predominou acima de seis anos (P < 0,00001) e à varicela (infecção natural) abaixo de sete anos (P < 0,001). O renal crônico pediátrico deve receber esquema vacinal amplo, com avaliação periódica de títulos de anticorpos / Infections are a cause of morbidity and mortality in chronic renal failure (CRF) patients, facilitated by uremia, which promotes a deficient immune response and hinders response to vaccination. We evaluated the immunization status and antibody titers against measles and varicella in 83 CRF children and adolescents. Adhesion to vaccination was 100% BCG, 98,8% poliomyelitis, 97,6% DPT, 96,4% measles, 88% MMR, 68,7% hepatitis B. Non-detectable antibodies against measles and varicella occurred in 14,5% and 26,5% patients. Susceptibility to measles, after vaccination, increased above 6 years (P < 0,00001) and to varicella (natural infection), below seven years of age (P < 0,001). Pediatric CRF patients should receive a robust immunization program with periodic antibody titer assessment
|
4 |
Impacto do reprocessamento de dialisadores de alto fluxo e alta eficiência sobre o transporte de solutos em sessões de hemodiafiltração online curta diária / Reprocessing high-flux, high-efficiency polysulfone dialyzers on solutes removal in short daily online hemodiafiltrationMelo, Natália Corrêa Vieira de 05 December 2013 (has links)
Introdução: Não há estudos que avaliem o impacto da reutilização do dialisador na remoção de solutos em sessões de hemodiafiltração online curta diária (HDF-OL-D). Objetivo: Avaliar o impacto do reuso do dialisador na dose do tratamento, na cinética de beta2-microglobulina e na extração de solutos em sessões de HDF-OL-D e comparar com sessões de hemodiálise curta diária de alto fluxo (HD-D). Métodos: Foram incluídos 14 pacientes do programa de HD-D. Foram coletadas amostras de sangue pré, no meio e pós-diálise e amostras do dialisato no 1º, 7º e 13º usos do dialisador em sessões de HD-D e de HDF-OL-D. Resultados: A massa total extraída (MTDQ) e a depuração (KDQ) diretamente quantificada dos solutos pequenos (ureia, fósforo, creatinina e ácido úrico), bem como a dose de diálise ofertada, foram semelhantes quando o 1º, 7º e 13º usos do dialisador em sessões de HD-D foram comparados, respectivamente, ao 1º, 7º e 13º usos em sessões de HDF-OL-D. A MTDQ e a KDQ dos solutos pequenos e a dose de diálise foram semelhantes entre os usos do dialisador tanto em sessões de HD-D e quanto em sessões de HDF-OL-D. A MTDQ, a KDQ e o Kt/V diretamente quantificado (Kt/VDQ) de beta2-microglobulina foram maiores em sessões de HDF-OL-D do que nos respectivos usos do dialisador em sessões de HD-D. Não houve diferença quanto à cinética de beta2-microglobulina, avaliada pela MTDQ, KDQ ou Kt/VDQ, entre o 1º, 7º e 13º usos do dialisador em sessões de HD-D nem em sessões de HDF-OL-D. Na HDF-OL-D, a perda intradialítica de albumina foi significativamente diferente entre os usos do dialisador (p < 0,001), estando reduzida no 7º e 13º usos, quando comparados ao 1º uso do dialisador. Não houve correlação entre o volume de enchimento do dialisador e a MTDQ e a KDQ de moléculas pequenas em nenhum dos métodos dialíticos estudados. Em sessões de HDF-OL-D, foi observada uma correlação fraca entre o volume de enchimento do dialisador e a KDQ de beta2-microglobulina, não percebida com a MTDQ ou o Kt/VDQ de beta2-microglobulina. Conclusão: O reprocessamento de dialisadores de alto fluxo e alta eficiência não resulta em comprometimento da dose do tratamento, da cinética de beta2-microglobulina nem da extração de solutos em sessões de HDF-OL-D. A extração de beta2-microglobulina foi maior em sessões de HDF-OL-D do que em sessões de HD-D, sem diferenças significativas na remoção dos demais solutos. O reprocessamento do filtro, em sessões de HDF-OL-D, resultou numa redução significativa da perda intradialítica de albumina. Não parece haver influência do volume de enchimento do filtro na extração de solutos em nenhum dos métodos de diálise estudados / Introduction: There no studies evaluating the impact of dialyzer reutilization on solute removal in daily online hemodiafiltration (D-OL-HDF) sessions. Objectives: Our aim was to evaluate the impact of dialyzer reuse on solute extraction, beta2-microglobulin kinetics and dialysis dose in D-OL-HDF and compare to those in high-flux short daily hemodialysis (D-HD). Methods: 14 patients undergoing a D-HD program were included. Pre, middle and post-dialysis blood samples and effluent dialysate were collected in the 1st, 7th and 13th dialyzer uses in D-HD sessions and in D-OL-HDF sessions. Results: Directly quantified small solute (urea, phosphorus, creatinine and uric acid) total mass removal (TMDQ) and clearance (KDQ), as well as dialysis dosis, were similar when the 1st, 7th and 13th dialyzer D-HD uses were compared to the 1st, 7th and 13th D-OL-HDF uses. TMDQ and KDQ of small solutes and dialysis dose were similar among dialyzer uses in D-HD sessions and also in D-OL-HDF sessions. beta2-microglobulin TMDQ, KDQ and directly quantified Kt/V (Kt/VDQ) were statistically higher in D-OL-HDF dialyzer uses than in the respective D-HD uses. There was no difference in beta2-microglobulin kinetics, evaluated by TMDQ, KDQ or Kt/VDQ, among 1st, 7th and 13th uses in D-OL-HDF sessions or in D-HD sessions. In D-OL-HDF, albumin loss was significantly different among studied dialyzer uses (p < 0.001), being reduced in the 7th and 13th dialyzer uses, when compared to the first use. There was no correlation between dialyzer priming volume and small molecules TMDQ, KDQ in neither analyzed dialytic method. In D-OL-HDF sessions, it was observed a week correlation between dialyzer priming volume and beta2-microglobulin KDQ, not observed with beta2-microglobulin MTDQ or Kt/VDQ. Conclusion: High flux, high efficiency dialyzer reprocessing did not did result in a reduction of the offered dialysis dose, beta2-microglobulin kinetics or solute extraction in D-OL-HDF. beta2-microglobulin removal was greater in D-OL-HDF than in D-HD sessions, without difference in other solutes extraction. There was a significant reduction in intradialytic albumin loss with dialyzer reprocessing in D-OL-HDF sessions. Dialyzer priming volume does not appear to influence solute removal in neither analyzed dialytic method
|
5 |
"Levantamento da situação vacinal e avaliação sorológica para sarampo e varicela de crianças e adolescentes portadores de insuficiência renal crônica em tratamento conservador e dialítico" / Immunization status analysis and evaluation of antibody titers against measles and varicella in 83 chronic renal failure children and adolescents in conservative and dialytic therapySimone Nascimento Fagundes 26 January 2004 (has links)
A infecção é causa de morbimortalidade no paciente com insuficiência renal crônica (IRC), facilitada pela uremia, que leva a resposta imune insuficiente, inclusive após a vacinação. Foram avaliadas a situação vacinal e a presença de anticorpos para sarampo e varicela, de 83 crianças e adolescentes com IRC. A adesão dos pacientes às vacinas foi BCG 100%, poliomielite 98,8%, DPT 97,6%, sarampo monovalente 96,4%, tríplice viral 88%, hepatite B 68,7%. Ausência de anticorpos para sarampo e varicela ocorreu em 14,5% e 26,5% dos pacientes. A susceptibilidade ao sarampo em vacinados, predominou acima de seis anos (P < 0,00001) e à varicela (infecção natural) abaixo de sete anos (P < 0,001). O renal crônico pediátrico deve receber esquema vacinal amplo, com avaliação periódica de títulos de anticorpos / Infections are a cause of morbidity and mortality in chronic renal failure (CRF) patients, facilitated by uremia, which promotes a deficient immune response and hinders response to vaccination. We evaluated the immunization status and antibody titers against measles and varicella in 83 CRF children and adolescents. Adhesion to vaccination was 100% BCG, 98,8% poliomyelitis, 97,6% DPT, 96,4% measles, 88% MMR, 68,7% hepatitis B. Non-detectable antibodies against measles and varicella occurred in 14,5% and 26,5% patients. Susceptibility to measles, after vaccination, increased above 6 years (P < 0,00001) and to varicella (natural infection), below seven years of age (P < 0,001). Pediatric CRF patients should receive a robust immunization program with periodic antibody titer assessment
|
6 |
Impacto do reprocessamento de dialisadores de alto fluxo e alta eficiência sobre o transporte de solutos em sessões de hemodiafiltração online curta diária / Reprocessing high-flux, high-efficiency polysulfone dialyzers on solutes removal in short daily online hemodiafiltrationNatália Corrêa Vieira de Melo 05 December 2013 (has links)
Introdução: Não há estudos que avaliem o impacto da reutilização do dialisador na remoção de solutos em sessões de hemodiafiltração online curta diária (HDF-OL-D). Objetivo: Avaliar o impacto do reuso do dialisador na dose do tratamento, na cinética de beta2-microglobulina e na extração de solutos em sessões de HDF-OL-D e comparar com sessões de hemodiálise curta diária de alto fluxo (HD-D). Métodos: Foram incluídos 14 pacientes do programa de HD-D. Foram coletadas amostras de sangue pré, no meio e pós-diálise e amostras do dialisato no 1º, 7º e 13º usos do dialisador em sessões de HD-D e de HDF-OL-D. Resultados: A massa total extraída (MTDQ) e a depuração (KDQ) diretamente quantificada dos solutos pequenos (ureia, fósforo, creatinina e ácido úrico), bem como a dose de diálise ofertada, foram semelhantes quando o 1º, 7º e 13º usos do dialisador em sessões de HD-D foram comparados, respectivamente, ao 1º, 7º e 13º usos em sessões de HDF-OL-D. A MTDQ e a KDQ dos solutos pequenos e a dose de diálise foram semelhantes entre os usos do dialisador tanto em sessões de HD-D e quanto em sessões de HDF-OL-D. A MTDQ, a KDQ e o Kt/V diretamente quantificado (Kt/VDQ) de beta2-microglobulina foram maiores em sessões de HDF-OL-D do que nos respectivos usos do dialisador em sessões de HD-D. Não houve diferença quanto à cinética de beta2-microglobulina, avaliada pela MTDQ, KDQ ou Kt/VDQ, entre o 1º, 7º e 13º usos do dialisador em sessões de HD-D nem em sessões de HDF-OL-D. Na HDF-OL-D, a perda intradialítica de albumina foi significativamente diferente entre os usos do dialisador (p < 0,001), estando reduzida no 7º e 13º usos, quando comparados ao 1º uso do dialisador. Não houve correlação entre o volume de enchimento do dialisador e a MTDQ e a KDQ de moléculas pequenas em nenhum dos métodos dialíticos estudados. Em sessões de HDF-OL-D, foi observada uma correlação fraca entre o volume de enchimento do dialisador e a KDQ de beta2-microglobulina, não percebida com a MTDQ ou o Kt/VDQ de beta2-microglobulina. Conclusão: O reprocessamento de dialisadores de alto fluxo e alta eficiência não resulta em comprometimento da dose do tratamento, da cinética de beta2-microglobulina nem da extração de solutos em sessões de HDF-OL-D. A extração de beta2-microglobulina foi maior em sessões de HDF-OL-D do que em sessões de HD-D, sem diferenças significativas na remoção dos demais solutos. O reprocessamento do filtro, em sessões de HDF-OL-D, resultou numa redução significativa da perda intradialítica de albumina. Não parece haver influência do volume de enchimento do filtro na extração de solutos em nenhum dos métodos de diálise estudados / Introduction: There no studies evaluating the impact of dialyzer reutilization on solute removal in daily online hemodiafiltration (D-OL-HDF) sessions. Objectives: Our aim was to evaluate the impact of dialyzer reuse on solute extraction, beta2-microglobulin kinetics and dialysis dose in D-OL-HDF and compare to those in high-flux short daily hemodialysis (D-HD). Methods: 14 patients undergoing a D-HD program were included. Pre, middle and post-dialysis blood samples and effluent dialysate were collected in the 1st, 7th and 13th dialyzer uses in D-HD sessions and in D-OL-HDF sessions. Results: Directly quantified small solute (urea, phosphorus, creatinine and uric acid) total mass removal (TMDQ) and clearance (KDQ), as well as dialysis dosis, were similar when the 1st, 7th and 13th dialyzer D-HD uses were compared to the 1st, 7th and 13th D-OL-HDF uses. TMDQ and KDQ of small solutes and dialysis dose were similar among dialyzer uses in D-HD sessions and also in D-OL-HDF sessions. beta2-microglobulin TMDQ, KDQ and directly quantified Kt/V (Kt/VDQ) were statistically higher in D-OL-HDF dialyzer uses than in the respective D-HD uses. There was no difference in beta2-microglobulin kinetics, evaluated by TMDQ, KDQ or Kt/VDQ, among 1st, 7th and 13th uses in D-OL-HDF sessions or in D-HD sessions. In D-OL-HDF, albumin loss was significantly different among studied dialyzer uses (p < 0.001), being reduced in the 7th and 13th dialyzer uses, when compared to the first use. There was no correlation between dialyzer priming volume and small molecules TMDQ, KDQ in neither analyzed dialytic method. In D-OL-HDF sessions, it was observed a week correlation between dialyzer priming volume and beta2-microglobulin KDQ, not observed with beta2-microglobulin MTDQ or Kt/VDQ. Conclusion: High flux, high efficiency dialyzer reprocessing did not did result in a reduction of the offered dialysis dose, beta2-microglobulin kinetics or solute extraction in D-OL-HDF. beta2-microglobulin removal was greater in D-OL-HDF than in D-HD sessions, without difference in other solutes extraction. There was a significant reduction in intradialytic albumin loss with dialyzer reprocessing in D-OL-HDF sessions. Dialyzer priming volume does not appear to influence solute removal in neither analyzed dialytic method
|
Page generated in 0.0471 seconds