• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 392
  • 294
  • 54
  • 42
  • 14
  • 10
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 1239
  • 674
  • 381
  • 234
  • 155
  • 154
  • 152
  • 152
  • 116
  • 103
  • 102
  • 100
  • 92
  • 92
  • 90
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliacao da resposta de detectores termoluminescentes na dosimetria de feixes clinicos utilizando diferentes objetos simuladores / Response evaluation of thermoluminescent detectors in clinical beams dosimetry using different phantoms

MATSUSHIMA, LUCIANA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:27Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
172

Preparacao de filmes indicadores de altas doses por variacao de ar

NAKAHIRA, HELENA K. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:29:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:47Z (GMT). No. of bitstreams: 1 01019.pdf: 1131567 bytes, checksum: 5ceeb9fd424e71ebd5852fcae5867465 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
173

Measurement of absorbed dose for paediatric patients for the purpose of developing dose guidelines in paediatric radiology

Swart, Gillian January 2004 (has links)
Thesis (MTech (Radiography))--Peninsula Technikon, 2004 / The radiation risks associated with children are higher than the risk for adults. Children have growing organs and they have a longer life expectancy than that of adults. As a consequence the effects of damage from radiation could be greater than in adults. Children who receive radiation damage may pass genetic damage onto future generations. This study was carried out to investigate the optimal effective x-ray dose young children need to receive who have radiographic examination to the chest at Tygerberg Hospital, South Africa. Chest radiographs are documented as being the most common radiographic examination done on children. The age groups of children participating in this study were 0-1 year, 1-5 years and 5-10 years. A total of 67 children were involved and the absorbed doses for 134 views of the anterior-posteria (AP) chest and lateral chest were measured. Entrance surface dose (ESD) values were determined, and measured mean ESD (mGy) and the ESD range was reported for each age group. This was done by attaching thermolurninescent dosirneters (TLD pellets) to the patients skin at the entrance point of the x-ray beam. The results were compared to similar studies done in Ireland and Nigeria From the ESD values obtained the absorbed doses ofthe eyes, heart, liver, thyroid and genitals could be calculated by using the "Childdose" programme ofthe NRPB. The ESD dose levels for South Africa compare favourably with Ireland. However the Nigerian values differed greatly from those of Ireland and South Africa It was very encouraging to note the comparative results achieved at Tygerberg Hospital especially due to the fact that this was the first time such study had been conducted in the Tygerberg Hospital Radiology Department. The results also compare favourable with that achieved by a group working in the United Kingdom. This group does similar surveys every five years as part of their radiation protection programme. The results were also in line with the UNSCEAR document of2000. v This study could serve as a valuable source of reference to radiographers and radiologists when performing paediatric radiology especially as the radiation absorbed dose could be used as a baseline to create awareness of size of dose received, and to limit deleterious radiation doses to patients and to prevent unnecessary exposures. A second significant outcome of the study was the effect that added filters had on the x-ray beam generated. Experiments were done in which the filtration filters were added sequentially. It was found that if the filtration was increased to 2mmAl the dose to the patient decreased by more than 20%. At 50 and 60 kV the density of the x-ray image on film only increased by 2%. From these results it may be concluded that an increase in filtration thickness used for paediatric chest x-rays should be giVIng reduced dose readings and assisting with radiation protection ofthe patient.
174

Um novo dosímetro de eletreto para radioterapia. / A new electrect dosimeter for radiotherapy.

Laura Natal Rodrigues 12 August 1985 (has links)
Neste trabalho apresentamos os resultados obtidos com um novo dosímetro de eletreto plano para uso em Radioterapia. O princípio de funcionamento do dosímetro de eletreto se baseia na utilização do campo do eletreto como o campo coletor de íons, em um sistema análogo ao da câmara de ionização, e ainda, corno um detector para a carga integrada. O modelo inicial do dosímetro possuía urna geometria cilíndrica. Através das curvas de calibração deste dosímetro, onde analisamos a sensibilidade, reprodutibilidade, estabilidade e, ainda, a dependência da sensibilidade com o volume e a pressão, concluímos que para aumentar a sua faixa útil de exposição, deveríamos construir um dosímetro com geometria plana. Estudamos a dependência da sensibilidade do dosímetro plano com as condições de carregamento do eletreto, volume da câmara e material da parede (alumínio, latão e aço inox) e os melhores resultados foram obtidos com o dosímetro de aço inox. Comparamos o comportamento deste sistema dosimétrico com um dosímetro Baldwin-Farmer, comumentemente usado em Radioterapia e verificamos que os resultados se mostraram satisfatórios. As características finais deste dosímetro são as seguintes: sensibilidade de 10-13C/R, volume de 0.20 cm3, reprodutibilidade de 5% e alcance máximo de exposição de 700 R. Finalmente, desenvolvemos um dosímetro múltiplo de eletreto para a medida da uniformidade do feixe de radiação para um aparelho de Cobaltoterapia. Os resultados da sua intercomparação com o dosímetro Baldwin-Farmer apresentaram uma variação máxima de 3%. / This work presents the results obtained with a new plane electret dosemeter for use in Radiotherapy. The working principle of the electrets dosemeter in based on the use for the electret field the ion collecting field, similarly to an ionization chamber, and as charge integrator detector. The dosemeter had, initially, a cylindrical geometry. The results attained with its calibration curve concerning the sensitivity, the stability and the reproducibility lead to changes in the dosimeter geometry. A plane geometry dosemeter was built in order to increase the useful exposure range. The plane dosemeter sensitivity dependence was measured versus the electrets charging conditions, the chamber volume and wall material (aluminium, brass, and stainless steel). The stainless steel dosemeter showed the best results. This dosemeter has the following characteristics: sensitivity 10-13C/R, volume 0.20 cm3, reproducibility 5%, and maximum exposure range 700 R. Compared to the Baldwin-Farmer dosemeter, this results are fairly good. A multiple electret dosemeter was developed to monitor the uniformity of the radiation beam for a Cobalt teletherapy unit. The intercomparasion with the Baldwin-Farmer unit presented a maximum variation of 3%.
175

Uso da apoptose de linfocitos perifericos humanos como metodo alternativo em dosimetria biologica dos efeitos da radiacao do cobalto-60

LEMES, MARISA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:22Z (GMT). No. of bitstreams: 1 05242.pdf: 4554031 bytes, checksum: a4475d4c8f70b6c49362da60da24b5c9 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
176

Dosimetria de neutrons rapidos

RZYSKI, BARBARA M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:49Z (GMT). No. of bitstreams: 1 00722.pdf: 1035259 bytes, checksum: c3c9dd7bddfbc4d12b362b3cf414a527 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Fisica, Universidade de Sao Paulo - IF/USP
177

Alguns metodos de calibracao e de dosimetria da radiacao beta

CALDAS, LINDA V.E. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:26Z (GMT). No. of bitstreams: 1 00678.pdf: 9537480 bytes, checksum: be1ea4e4b9aab450e6d6ab87ca904eee (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Fisica, Universidade de Sao Paulo - IF/USP
178

Avaliacao da resposta de detectores termoluminescentes na dosimetria de feixes clinicos utilizando diferentes objetos simuladores / Response evaluation of thermoluminescent detectors in clinical beams dosimetry using different phantoms

MATSUSHIMA, LUCIANA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:27Z (GMT). No. of bitstreams: 0 / A radioterapia é uma das três principais modalidades de tratamento utilizadas no tratamento de doenças malignas, como o câncer; as duas outras são a quimioterapia e a radiocirurgia. Em contraste com outras especialidades médicas que necessitam principalmente de conhecimento clínico e da experiência de especialistas, a radioterapia, com o uso da radiação ionizante no tratamento do câncer, necessita de grandes investimentos em tecnologias modernas e do esforço colaborativo de diversos profissionais que contribuem para o sucesso do tratamento. Na área de dosimetria clínica, uma calibração eficiente e precisa do feixe de radiação garante o conhecimento da dose fornecida ao paciente, assegurando, portanto, o sucesso do tratamento radioterápico. Este trabalho tem por objetivo o estudo comparativo da resposta termoluminescente dos dosímetros de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN (6 mm de diâmetro e 0,8 mm de espessura) com a resposta dos dosímetros de fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti com 3,15 x 3,15 x 0,9 mm3) na dosimetria de feixes clínicos de fótons (6 e 15 MV) e elétrons (6 e 9 MeV) utilizando objetos simuladores de água sólida (RMI-457), água e PMMA. Foram obtidas as curvas de dose-resposta para a radiação gama do cobalto-60 (60Co) no ar e em condições de equilíbrio eletrônico (placa de PMMA), e para elétrons e fótons clínicos nas profundidades de dose máxima. Foi avaliada também a sensibilidade dos dosímetros termoluminescentes e determinada a reprodutibilidade da resposta e a eficiência intrínseca para os diferentes tipos de simuladores e energias de radiação estudadas. Os resultados obtidos indicam que a principal vantagem do dosímetro de CaSO4:Dy é a sua maior sensibilidade para as doses de radiação avaliadas para os feixes do 60Co, fótons e elétrons, representando, portanto, uma alternativa viável para a aplicação em dosimetria nos setores de radioterapia. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
179

Preparacao de filmes indicadores de altas doses por variacao de ar

NAKAHIRA, HELENA K. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:29:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:47Z (GMT). No. of bitstreams: 1 01019.pdf: 1131567 bytes, checksum: 5ceeb9fd424e71ebd5852fcae5867465 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
180

Desenvolvimento e implantação de um programa de controle e aquisição de dados na calibração de instrumentos em radiodiagnostico

BETTI, FLAVIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:21Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:27Z (GMT). No. of bitstreams: 1 12752.pdf: 1446592 bytes, checksum: bbd9a40baa2d04acc21669d03e871456 (MD5) / Neste trabalho foram desenvolvidas as técnicas para projetar e implantar um sistema automatizado de controle e aquisição de dados para o arranjo de calibração em radiação X níveis diagnóstico e radioproteção do Laboratório de Calibração de Instrumentos (LCI) do IPEN. Os programas desenvolvidos fornecem diretamente os valores de kerma corrigidos para as condições ambientais. A automatização do obturador viabilizou a temporização precisa de exposições de curta duração. A utilização da câmara monitora como padrão de calibração beneficiou-se de um programa para a determinação de seus fatores de calibração a partir de uma câmara de referência para as diferentes qualidades de feixe. Foram utilizados como instrumentos de referência, dois eletrômetros, um para a câmara monitora, e outro para a câmara padrão; um termômetro de dois canais, e um barômetro absoluto, todos comunicando-se com o microcomputador através de interface padrão RS-232. São descritos os métodos computacionais utilizados nos programas de controle do kerma pela câmara monitora, bem como no de obtenção de seus fatores de calibração. A linguagem de programação adotada (LabVIEW MR) permitiu a obtenção de resultados rápidos e adequados. Os resultados obtidos demonstraram que o novo sistema proposto está apto a substituir as técnicas anteriormente adotadas no LCI, com vantagens no que diz respeito à rapidez e precisão na execução das calibrações, notadamente sob situações adversas, como as observadas em exposições muito curtas, ou então longas o suficiente para que sejam substancialmente afetadas pela flutuação de parâmetros tais como a taxa de kerma do gerador de raios X, ou então pelas condições ambientais de temperatura e pressão. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0368 seconds