A Comparison of NAL and DSL Prescriptive Methods for Paediatric Hearing-Aid Fitting: Predicted Speech Intelligibility and Loudness

Ching, Teresa Y.C., Johnson, Earl E., Hou, Sanna, Dillon, Harvey, Zhang, Vicky, Burns, Lauren, van Buynder, Patricia, Wong, Angela, Flynn, Christopher 01 December 2013 (has links)
Objective: To examine the impact of prescription on predicted speech intelligibility and loudness for children. Design: A between-group comparison of speech intelligibility index (SII) and loudness, based on hearing aids fitted according to NAL-NL1, DSL v4.1, or DSL m[i/o] prescriptions. A within-group comparison of gains prescribed by DSL m[i/o] and NAL-NL2 for children in terms of SII and loudness. Study sample: Participants were 200 children, who were randomly assigned to first hearing-aid fitting with either NAL-NL1, DSL v4.1, or DSL m[i/o]. Audiometric data and hearing-aid data at 3 years of age were used. Results: On average, SII calculated on the basis of hearing-aid gains were higher for DSL than for NAL-NL1 at low input level, equivalent at medium input level, and higher for NAL-NL1 than DSL at high input level. Greater loudness was associated with DSL than with NAL-NL1, across a range of input levels. Comparing NAL-NL2 and DSL m[i/o] target gains revealed higher SII for the latter at low input level. SII was higher for NAL-NL2 than for DSL m[i/o] at medium- and high-input levels despite greater loudness for gains prescribed by DSL m[i/o] than by NAL-NL2. Conclusion: The choice of prescription has minimal effects on speech intelligibility predictions but marked effects on loudness predictions.
2

A Comparison of Gain for Adults from Generic Hearing Aid Prescriptive Methods: Impacts on Predicted Loudness, Frequency Bandwidth, and Speech Intelligibility

Johnson, Earl E., Dillon, Harvey 01 July 2011 (has links)
Background: Prescriptive methods have been at the core of modern hearing aid fittings for the past several decades. Every decade or so, there have been revisions to existing methods and/or the emergence of new methods that become widely used. In 2001 Byrne et al provided a comparison of insertion gain for generic prescriptive methods available at that time. Purpose: The purpose of this article was to compare National Acoustic Laboratories—Non-linear 1 (NAL-NL1), National Acoustic Laboratories—Non-linear 2 (NAL-NL2), Desired Sensation Level Multistage Input/Output (DSL m[i/o]), and Cambridge Method for Loudness Equalization 2—High-Frequency (CAMEQ2-HF) prescriptive methods for adults on the amplification characteristics of prescribed insertion gain and compression ratio. Following the differences observed in prescribed insertion gain among the four prescriptive methods, analyses of predicted specific loudness, overall loudness, and bandwidth of cochlear excitation and effective audibility as well as speech intelligibility of the international long-term average speech spectrum (ILTASS) at an average conversational input level were completed. These analyses allow for the discussion of similarities and differences among the present-day prescriptive methods. Research Design: The impact of insertion gain differences among the methods is examined for seven hypothetical hearing loss configurations using models of loudness perception and speech intelligibility. Study Sample: Hearing loss configurations for adults of various types and degrees were selected, five of which represent sensorineural impairment and were used by Byrne et al; the other two hearing losses provide an example of mixed and conductive impairment. Data Collection and Analysis: Prescribed insertion gain data were calculated in 1/3-octave frequency bands for each of the seven hearing losses from the software application of each prescriptive method over multiple input levels. The insertion gain data along with a diffuse field-to-eardrum transfer function were used to calculate output levels at the eardrums of the hypothetical listeners. Levels of hearing loss and output were then used in the Moore and Glasberg loudness model and the ANSI S3.5-1997 Speech Intelligibility Index model. Results: NAL-NL2 and DSL m[i/o] provided comparable overall loudness of approximately 8 sones for the five sensorineural hearing losses for a 65 dB SPL ILTASS input. This loudness was notably less than that perceived by a normal-hearing person for the same input signal, 18.6 sones. NAL-NL2 and DSL m[i/o] also provided comparable predicted speech intelligibility in quiet and noise. CAMEQ2-HF provided a greater average loudness, similar to NAL-NL1, with more high-frequency bandwidth but no significant improvement to predicted speech intelligibility. Conclusions: Definite variation in prescribed insertion gain was present among the prescriptive methods. These differences when averaged across the hearing losses were, by and large, negligible with regard to predicted speech intelligibility at normal conversational speech levels. With regard to loudness, DSL m[i/o] and NAL-NL2 provided the least overall loudness, followed by CAMEQ2-HF and NAL-NL1 providing the most loudness. CAMEQ2-HF provided the most audibility at high frequencies; even so, the audibility became less effective for improving speech intelligibility as hearing loss severity increased.