Spelling suggestions: "subject:"data accuracy"" "subject:"data ccuracy""
11 |
Evaluation of antiretroviral therapy information system in Mbale Regional Referral Hospital, UgandaOlupot-Olupot, Peter January 2008 (has links)
Magister Public Health - MPH / HIV/AIDS is the largest and most serious global epidemic in the recent times. To date, the epidemic has affected approximately 40 million people (range 33 - 46 million) of whom 67%, that is, an estimated 27 million people are in the Sub Saharan Africa. The Sub Saharan Africa is also reported to have the highest regional prevalence of 7.2% compared to an average of 2% in other regions. A medical cure for HIV/AIDS remains elusive but use of antiretroviral therapy (ART) has resulted in improvement of quality and quantity of life as evidenced by the reduction of mortality and morbidity associated with the infection, hence longer and good quality life for HIV/AIDS patients on ART. / South Africa
|
12 |
Estimating Accuracy of Personal Identifiable Information in Integrated Data SystemsShatnawi, Amani "Mohammad Jum'h" Amin 01 August 2017 (has links)
Without a valid assessment of accuracy there is a risk of data users coming to incorrect conclusions or making bad decision based on inaccurate data. This dissertation proposes a theoretical method for developing data-accuracy metrics specific for any given person-centric integrated system and how a data analyst can use these metrics to estimate the overall accuracy of person-centric data.
Estimating the accuracy of Personal Identifiable Information (PII) creates a corresponding need to model and formalize PII for both the real-world and electronic data, in a way that supports rigorous reasoning relative to real-world facts, expert opinions, and aggregate knowledge. This research provides such a foundation by introducing a temporal first-order logic language (FOL), called Person Data First-order Logic (PDFOL). With its syntax and semantics formalized, PDFOL provides a mechanism for expressing data- accuracy metrics, computing measurements using these metrics on person-centric databases, and comparing those measurements with expected values from real-world populations. Specifically, it enables data analysts to model person attributes and inter-person relations from real-world population or database representations of such, as well as real-world facts, expert opinions, and aggregate knowledge. PDFOL builds on existing first-order logics with the addition of temporal predicated based on time intervals, aggregate functions, and tuple-set comparison operators. It adapts and extends the traditional aggregate functions in three ways: a) allowing any arbitrary number free variables in function statement, b) adding groupings, and c) defining new aggregate function. These features allow PDFOL to model person-centric databases, enabling formal and efficient reason about their accuracy.
This dissertation also explains how data analysts can use PDFOL statements to formalize and develop formal accuracy metrics specific to a person-centric database, especially if it is an integrated person- centric database, which in turn can then be used to assess the accuracy of a database. Data analysts apply these metrics to person-centric data to compute the quality-assessment measurements, YD. After that, they use statistical methods to compare these measurements with the real-world measurements, YR. Compare YD and YR with the hypothesis that they should be very similar, if the person-centric data is an accurate and complete representations of the real-world population.
Finally, I show that estimated accuracy using metrics based on PDFOL can be good predictors of database accuracy. Specifically, I evaluated the performance of selected accuracy metrics by applying them to a person-centric database, mutating the database in various ways to degrade its accuracy, and the re-apply the metrics to see if they reflect the expected degradation.
This research will help data analyst to develop an accuracy metrics specific to their person-centric data. In addition, PDFOL can provide a foundation for future methods for reasoning about other quality dimensions of PII.
|
13 |
Validade do mapeamento do linfonodo sentinela na detecção de metástase linfática cervical do carcinoma papilífero da glândula tireoide / Impact of sentinel lymph node mapping to detect papillary thyroid carcinoma lymph node metastasisSteck, José Higino 23 June 2016 (has links)
INTRODUÇÃO: O mapeamento do linfonodo sentinela (MLNS) é largamente utilizado em pacientes com melanoma cutâneo, câncer de mama e outras neoplasias malignas sólidas com a finalidade de estadiá-las e indicar esvaziamento linfático apenas na presença de metástase. Nos últimos anos aumentou o interesse pelo uso do MLNS em pacientes com carcinoma papilífero de tireoide (CPT) sem metástases linfáticas detectáveis clinicamente (estádio cN0), devido à alta frequência de metástases ocultas nesses pacientes. O MLNS pode evitar o esvaziamento linfático do compartimento central (ECC) em portadores de CPT sem metástase. Mesmo que não se planeje o ECC eletivo, o MLNS pode também ser usado para estadiar adequadamente o pescoço e indicar tratamento posterior com radioiodoterapia em casos com metástase. Esse estudo tem como objetivo verificar: 1) a efetividade da técnica do MLNS nos pacientes com CPT; 2) a acurácia do MLNS em diagnosticar as metástases linfáticas; 3) se o MLNS pode modificar o estadiamento dos pacientes com CPT cN0. MÉTODOS: Trata-se de estudo de acurácia, prospectivo longitudinal de 38 casos consecutivos de CPT clinicamente N0, atendidos em um único centro, no período de 2010 a 2015. Todos foram submetidos à tireoidectomia total, MLNS com radiofármaco e ECC eletivo. Os resultados relativos ao MLNS foram comparados com o exame anatomopatológico do conteúdo do ECC. RESULTADOS: O tempo médio de seguimento dos doentes foi de 36 ± 13 meses. Os LNS foram localizados com maior frequência nos níveis VI e III. O LNS foi detectado em 95% da casuística e os valores de avaliação de testes diagnósticos foram: 1 falso negativo, 95% de sensibilidade, 100% de especificidade, 94% de valor preditivo negativo e 97% de acurácia. O MLNS foi capaz de reestadiar 49% dos pacientes inicialmente N0 para pN positivo. Quanto ao grupo de estadiamento AJCC (que leva em conta a idade), 3% dos pacientes foram reestadiados para estádio III e 18% para estádio IV. CONCLUSÕES: 1) a técnica de MLNS utilizada nos pacientes com CPT foi efetiva em 95% dos procedimentos realizados; 2) a acurácia do MLNS em diagnosticar as metástases linfáticas cervicais foi de 97%; 3) o MLNS re-estadiou os portadores de CPT, classificados clinicamente como N0, para pN positivo em 49% da casuística, e para estádio III e IVa em 21% / INTRODUCTON: Sentinel lymph node mapping (SLNM) is widely perfomed in melanoma, breast cancer and other solid tumors, to adequately stage these diseases. More recently, the interest in SLNM for clinically N0 Papillary Thyroid Cancer (PTC) has increased due to the high rate of occult metastases in these patients, to avoid unnecessary central neck dissection (CND), and its complications. Even if routine elective CND is not planned, SLNM can be used to adequately stage the neck, and to indicate further treatment with radioiodine in cases with neck metastases, for instance. This study aims to evaluate 1) SLNM effectiveness in PTC patients, 2) SLNM accuracy to diagnosis lymph node metastases and 3) if SLNM can upstage cN0 PTC patients. METHODS: This is a prospective longitudinal, diagnostic test accuracy study with 38 consecutive cN0 PTC patients, treated in a single center between 2010 and 2015. Surgical treatment in all cases included total thyroidectomy and elective CND after SLNM. Results of SLNM were compared to CND pathological findings, in order to verify if sentinel lymph node (SLN) predicted the occurrence of PTC occult lymph node metastasis. RESULTS: The mean patients\' follow-up was 36 ± 13 months. 133 SLN were found in the neck, on levels VI and III. The SLN was identified in 95% of the patients with 1 false negative, 95% sensitivity, 94% negative predictive value and 97% accuracy. The SLNM upstaging from cN0 to pN+ was 49%, with 3% stage III and 18% stage IVa. CONCLUSION: 1) SLNM was effective in 95% of procedures, 2) SLNM accuracy was 97%, 3) SLNM upstaging from cN0 to pN+ was 49%, and to stage III and IVa was 21%
|
14 |
Validade e confiabilidade da ressonância magnética para o diagnóstico da rotura do tendão do subescapular / Validity and reliability of magnetic resonance imaging for the diagnosis of subscapularis tendon tearRamadan, Lucas Busnardo 19 September 2018 (has links)
INTRODUCÃO: A acurácia da ressonância magnetica (RM) para a detecção de rotura do subescapular apresenta ampla variação na literatura. Existem poucos estudos prospectivos e grande variação metodológica. Acredita-se que estas roturas sejam mais dificilmente diagnosticadas do que as posterossuperiores. O tendão do subescapular apresenta importância na biomecânica no ombro e sua rotura leva a prejuízo funcional. Uma ferramenta diagnóstica de boa acurácia é fundamental na prática clínica, influenciando o prognóstico e o planejamento cirúrgico. O objetivo deste estudo foi avaliar a validade da RM pre-operatória na identificação das roturas do subescapular, comparando os achados de imagem com os dados intra-operatórios de cirurgia artroscó pica. Como objetivo secundário, avaliamos a confiabilidade do método, por meio da concordância interobservador e intraobservador. MÈTODOS: Realizamos um estudo de acurácia diagnóstica comparando os achados da RM (teste índice) com os da artroscopia (teste de referência), em uma coorte prospectiva. Foram incluídos pacientes submetidos a artroscopia para tratamento de roturas do manguito rotador que houvessem realizado RM de alto campo magnético, sem uso de contraste. Foram excluídos casos de manipulacão cirúrgica pregressa no ombro, exames com artefatos de movimentação, indicação cirurgia por via aberta e intervalo entre a RM e procedimento cirúrgico superior a um ano. As imagens foram avaliadas por um cirurgião de ombro e dois radiologistas musculoesqueleticos, de maneira independente e cegos em relacão aos resultados da artroscopia, sendo reavaliadas apos 3 meses pelo cirurgião. Calculamos a validade (sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia) e confiabilidade (concordancia inter e intraobservador) da RM em detectar roturas do subescapular. RESULTADOS: Avaliamos 200 ombros. A incidencia de roturas do subescapular foi de 69,5% (41,5% parciais e 28,0% transfixantes). O cirurgião de ombro apresentou sensibilidade de 51,1 a 59,0% e especificidade de 91,7% a 94,4%. Os radiologistas, 83,5 a 87,1% de sensibilidade e 41 a 45,9% de especificidade. A acura?cia variou de 60,5 a 73,0%. Os valores médios de sensibilidade, especificidade e acurácia foram 70,2%, 61,9% e 67,6%, respectivamente. A concordância interobservador foi moderada para a deteccao de roturas do subescapular (coeficiente kappa 0,463, IC 95% 0,383- 0,534, p < 0,001), assim como a intraobservador (coeficiente kappa 0,546, IC 95% 0,430-0,662, p < 0,001). Os pacientes com rotura do subescapular apresentaram maior incidencia de rotura e instabilidade do bíceps, maior degeneração gordurosa do subescapular e média de idade superior. As demais variáveis nao apresentaram diferenças estatisticamente significantes. CONCLUSAO: A RM de alto campo magneético sem contraste apresentou valores médios de sensibilidade, especificidade e acurácia de 70,2%, 61,9% e 67,6%, respectivamente. A sensibilidade foi superior nos radiologistas enquanto a especificidade no cirurgião de ombro. A concordância interobservador e intraobservador foi moderada / INTRODUCTION: The accuracy of magnetic resonance imaging (MRI) for the detection of subscapularis tear presents wide variation in the literature. There are few prospective studies and great methodological variation. It is believed that these tears are more difficult to diagnose than the posterosuperiores rotator cuff injuries. The subscapularis tendon has importance in the biomechanics in the shoulder and its rupture leads to functional impairment. A diagnostic tool of good accuracy is fundamental in clinical practice, influencing prognosis and surgical planning. The aim of this study was to evaluate the validity of preoperative MRI in the identification of the subscapularis tears, comparing the imaging findings with the intraoperative data of arthroscopic surgery. As a secondary objective, we evaluated the reliability of the method through interobserver and intraobserver agreement. METHODS: We performed a diagnostic accuracy study comparing MRI findings (index test) with those of arthroscopy (reference test), in a prospective cohort. We included patients submitted to arthroscopy for the treatment of rotator cuff tears that had undergone high magnetic field MRI without using contrast. Cases of previous surgical manipulation in the shoulder, exams with moving artifacts, indication for open surgery and interval between MRI and surgical procedure of more than one year were excluded. The images were evaluated by a shoulder surgeon and two musculoskeletal radiologists, independently and blinded to the results of arthroscopy, being reassessed after 3 months by the surgeon. We calculated the validity (sensitivity, specificity, positive predictive value, negative predictive value and accuracy) and reliability (inter- and intraobserver agreement) of MR in detecting subscapularis tears. RESULTS: We evaluated 200 shoulders. The incidence of subscapularis tears was 69.5% (41.5% partial and 28.0% transfixing). The shoulder surgeon showed sensitivity from 51.1 to 59.0% and specificity from 91.7% to 94.4%. The radiologists, 83.5 to 87.1% of sensitivity and 41 to 45.9% of specificity. Accuracy ranged from 60.5 to 73.0%. The mean values of sensitivity, specificity and accuracy were 70.2%, 61.9% and 67.6%, respectively. Interobserver agreement was moderate for the detection of subscapular tears (kappa coefficient 0.463, 95% CI 0.383-0.534, p < 0.001), as well as intraobserver agreement (kappa coefficient 0.546, 95% CI 0.430-0.662, p < 0.001). Patients with subscapular rupture had a higher incidence of biceps rupture and instability, greater fat subscapular degeneration, and higher mean age. The other variables did not present statistically significant differences. CONCLUSION: MRI of high magnetic field without contrast showed mean values of sensitivity, specificity and accuracy of 70.2%, 61.9% and 67.6%, respectively. Sensitivity was higher in radiologists while specificity in the shoulder surgeon. Interobserver and intraobserver agreement was moderate
|
15 |
Desenvolvimento de um método tentativo para a melhoria da acuridade de dados de um sistema de programação da produção – um estudo de caso em uma empresa do setor de alimentos cárneosRücker, Eduardo Scherer 27 February 2009 (has links)
Made available in DSpace on 2015-03-05T17:04:35Z (GMT). No. of bitstreams: 0
Previous issue date: 27 / Nenhuma / O presente estudo teve como objetivo o desenvolvimento de um método tentativo para a melhoria da acuracidade dos dados de um sistema específico de programação da produção para a indústria cárnea. A proposição baseou-se no projeto de implementação da referida ferramenta na Empresa Alfa, a qual produz alimentos a base de frangos, perus e suínos. O método de pesquisa utilizado foi um estudo de caso, por meio do qual se relatou e se analisou a influência da acuracidade dos dados sobre as informações geradas pelo sistema durante o projeto. O desenvolvimento do método proposto baseou-se no referencial teórico sobre programação da produção, qualidade de dados e qualidade de informações; nas percepções do autor acerca da participação do mesmo no projeto onde se aplicou o estudo de caso; e nas contribuições de especialistas na temática do trabalho. A partir disso, estruturou-se o método tentativo por meio de processos e subprocessos, hierarquização que possibilitou a execução dos objetivos de cada processo em relação / This study aims to develop a tentative method for improving the data accuracy of a specific production scheduling software for the meat industry. The proposition was based on the project phase of the implementation of a tool in Empresa Alfa, which produces food based on chickens, turkeys and porks. The research method used was a case study, by means of which it is reported and analyzed the influence of data accuracy on the information generated by the system during the project. The development of the proposed method was based on the theoretical framework on production scheduling, data quality and information quality, the author's perceptions about the same project which was applied in the case study and the contributions of experts in the thematic of the work. From this, the tentative method was structured by means of processes and subprocesses, hierarchy that enabled the implementation of the objectives of each process regarding the data accuracy in stages (subprocesses). At the end of the study, the autor c
|
16 |
Validade e confiabilidade da ressonância magnética para o diagnóstico da rotura do tendão do subescapular / Validity and reliability of magnetic resonance imaging for the diagnosis of subscapularis tendon tearLucas Busnardo Ramadan 19 September 2018 (has links)
INTRODUCÃO: A acurácia da ressonância magnetica (RM) para a detecção de rotura do subescapular apresenta ampla variação na literatura. Existem poucos estudos prospectivos e grande variação metodológica. Acredita-se que estas roturas sejam mais dificilmente diagnosticadas do que as posterossuperiores. O tendão do subescapular apresenta importância na biomecânica no ombro e sua rotura leva a prejuízo funcional. Uma ferramenta diagnóstica de boa acurácia é fundamental na prática clínica, influenciando o prognóstico e o planejamento cirúrgico. O objetivo deste estudo foi avaliar a validade da RM pre-operatória na identificação das roturas do subescapular, comparando os achados de imagem com os dados intra-operatórios de cirurgia artroscó pica. Como objetivo secundário, avaliamos a confiabilidade do método, por meio da concordância interobservador e intraobservador. MÈTODOS: Realizamos um estudo de acurácia diagnóstica comparando os achados da RM (teste índice) com os da artroscopia (teste de referência), em uma coorte prospectiva. Foram incluídos pacientes submetidos a artroscopia para tratamento de roturas do manguito rotador que houvessem realizado RM de alto campo magnético, sem uso de contraste. Foram excluídos casos de manipulacão cirúrgica pregressa no ombro, exames com artefatos de movimentação, indicação cirurgia por via aberta e intervalo entre a RM e procedimento cirúrgico superior a um ano. As imagens foram avaliadas por um cirurgião de ombro e dois radiologistas musculoesqueleticos, de maneira independente e cegos em relacão aos resultados da artroscopia, sendo reavaliadas apos 3 meses pelo cirurgião. Calculamos a validade (sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia) e confiabilidade (concordancia inter e intraobservador) da RM em detectar roturas do subescapular. RESULTADOS: Avaliamos 200 ombros. A incidencia de roturas do subescapular foi de 69,5% (41,5% parciais e 28,0% transfixantes). O cirurgião de ombro apresentou sensibilidade de 51,1 a 59,0% e especificidade de 91,7% a 94,4%. Os radiologistas, 83,5 a 87,1% de sensibilidade e 41 a 45,9% de especificidade. A acura?cia variou de 60,5 a 73,0%. Os valores médios de sensibilidade, especificidade e acurácia foram 70,2%, 61,9% e 67,6%, respectivamente. A concordância interobservador foi moderada para a deteccao de roturas do subescapular (coeficiente kappa 0,463, IC 95% 0,383- 0,534, p < 0,001), assim como a intraobservador (coeficiente kappa 0,546, IC 95% 0,430-0,662, p < 0,001). Os pacientes com rotura do subescapular apresentaram maior incidencia de rotura e instabilidade do bíceps, maior degeneração gordurosa do subescapular e média de idade superior. As demais variáveis nao apresentaram diferenças estatisticamente significantes. CONCLUSAO: A RM de alto campo magneético sem contraste apresentou valores médios de sensibilidade, especificidade e acurácia de 70,2%, 61,9% e 67,6%, respectivamente. A sensibilidade foi superior nos radiologistas enquanto a especificidade no cirurgião de ombro. A concordância interobservador e intraobservador foi moderada / INTRODUCTION: The accuracy of magnetic resonance imaging (MRI) for the detection of subscapularis tear presents wide variation in the literature. There are few prospective studies and great methodological variation. It is believed that these tears are more difficult to diagnose than the posterosuperiores rotator cuff injuries. The subscapularis tendon has importance in the biomechanics in the shoulder and its rupture leads to functional impairment. A diagnostic tool of good accuracy is fundamental in clinical practice, influencing prognosis and surgical planning. The aim of this study was to evaluate the validity of preoperative MRI in the identification of the subscapularis tears, comparing the imaging findings with the intraoperative data of arthroscopic surgery. As a secondary objective, we evaluated the reliability of the method through interobserver and intraobserver agreement. METHODS: We performed a diagnostic accuracy study comparing MRI findings (index test) with those of arthroscopy (reference test), in a prospective cohort. We included patients submitted to arthroscopy for the treatment of rotator cuff tears that had undergone high magnetic field MRI without using contrast. Cases of previous surgical manipulation in the shoulder, exams with moving artifacts, indication for open surgery and interval between MRI and surgical procedure of more than one year were excluded. The images were evaluated by a shoulder surgeon and two musculoskeletal radiologists, independently and blinded to the results of arthroscopy, being reassessed after 3 months by the surgeon. We calculated the validity (sensitivity, specificity, positive predictive value, negative predictive value and accuracy) and reliability (inter- and intraobserver agreement) of MR in detecting subscapularis tears. RESULTS: We evaluated 200 shoulders. The incidence of subscapularis tears was 69.5% (41.5% partial and 28.0% transfixing). The shoulder surgeon showed sensitivity from 51.1 to 59.0% and specificity from 91.7% to 94.4%. The radiologists, 83.5 to 87.1% of sensitivity and 41 to 45.9% of specificity. Accuracy ranged from 60.5 to 73.0%. The mean values of sensitivity, specificity and accuracy were 70.2%, 61.9% and 67.6%, respectively. Interobserver agreement was moderate for the detection of subscapular tears (kappa coefficient 0.463, 95% CI 0.383-0.534, p < 0.001), as well as intraobserver agreement (kappa coefficient 0.546, 95% CI 0.430-0.662, p < 0.001). Patients with subscapular rupture had a higher incidence of biceps rupture and instability, greater fat subscapular degeneration, and higher mean age. The other variables did not present statistically significant differences. CONCLUSION: MRI of high magnetic field without contrast showed mean values of sensitivity, specificity and accuracy of 70.2%, 61.9% and 67.6%, respectively. Sensitivity was higher in radiologists while specificity in the shoulder surgeon. Interobserver and intraobserver agreement was moderate
|
17 |
Proposta de um roteiro para auxiliar o gestor no processo de monitoramento do faturamento nos setores de urgência/emergência e internação hospitalar no Sistema Único de Saúde / Proposal of a route to help the manager in the process of monitoring the billing in the urgency/emergency and hospital interment sectors in the Single Health SystemMathias, Denise 06 December 2016 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2017-01-26T16:50:06Z
No. of bitstreams: 1
Denise Mathias.pdf: 1924270 bytes, checksum: 1900fdbe1184fceb35832b8db907ba1e (MD5) / Made available in DSpace on 2017-01-26T16:50:06Z (GMT). No. of bitstreams: 1
Denise Mathias.pdf: 1924270 bytes, checksum: 1900fdbe1184fceb35832b8db907ba1e (MD5)
Previous issue date: 2016-12-06 / The Brazilian public hospital billing is composed of different non-integrated systems, which hinders the accuracy of the obtained data, and consequently the work of the managers on this area in guaranteeing a precise billing that correctly reflects the given assistance. The objective of this work was to construct a tool that helps in the monitoring of the accuracy of some essential procedures to be included in the database of the Walk In Care Information System and a verification script for the registry of executed procedures on the medical records and that should be posted to the Hospital Information System, in order to mitigate risks of nonconformity of information. The tool was implemented in the São Mateus Pronto Care ( Walk In Care ? ) facility, part of the network of units under management of the Municipal Hospital Autarquia, as this facility presented the largest discrepancy between the quantity and approved value. After that it was extended to another 36 Walk In Care units of all sizes. The results were analyzed based on the referenced values from Table of Procedures, Medications, Orthotics, Prostheses and Special Materials-OPM (SIGTAP). The research provided the identification of interference factors in the process of coding and recording care that compromised the accuracy of the database in the Outpatient Information System. The proposed tool contributed to the accuracy of the registry, the comparative analysis between the 1st quarter of 2009 and the 1st quarter of 2010, evidencing a difference of 5.2 times lower in the average value of the medical procedure. The proposed script, using the variable value of the daily rate and length of stay for the treatment of pneumonia or influenza (flu), compared to the same variables of the SIGTAP, evidenced the increase of the daily value from 75% to 84% in relation to the reference. / O faturamento hospitalar público brasileiro é composto por diferentes sistemas não integrados, o que dificulta a acurácia dos dados obtidos, e consequentemente o trabalho dos gestores desta área em garantir um faturamento preciso que traduza a assistência, o objetivo deste trabalho foi construir um instrumento que auxilie no monitoramento da exatidão de alguns procedimentos essenciais de constarem na base de dados do Sistema de Informação Ambulatorial e um roteiro de verificação do registro de procedimentos constantes no prontuário de clínica médica e que devem ser lançados no Sistema de Informação Hospitalar, visando mitigar riscos de inconformidade da informação. O instrumento foi aplicado no estabelecimento Pronto Atendimento São Mateus, integrante da rede de unidades sob gestão da Autarquia Hospitalar Municipal, por ser o que apresentava a maior discrepância entre a quantidade e valor aprovado, posteriormente foi estendido para o universo de 36 unidades, de pequeno a grande porte. Os resultados foram analisados a partir dos valores referenciados na Tabela de Procedimentos, Medicamentos, Órteses, Próteses e Materiais Especiais-OPM (SIGTAP). A pesquisa proporcionou a identificação de fatores de interferência no processo de codificação e registro da assistência que comprometiam a acurácia da base de dados no Sistema de Informação Ambulatorial. O instrumento proposto contribuiu com a precisão do registro, a análise comparativa entre o 1º trimestre de 2009 e o 1º trimestre de 2010, evidenciou diferença de 5,2 vezes a menor no valor médio do procedimento. O roteiro proposto, utilizando a váriável valor da diária e tempo de permanência para o tratamento de pneumonias ou influenza (gripe), comparado às mesmas variáveis do SIGTAP, evidenciou a elevação do valor da diária de 75% para 84% em relação à referência.
|
18 |
Validade do mapeamento do linfonodo sentinela na detecção de metástase linfática cervical do carcinoma papilífero da glândula tireoide / Impact of sentinel lymph node mapping to detect papillary thyroid carcinoma lymph node metastasisJosé Higino Steck 23 June 2016 (has links)
INTRODUÇÃO: O mapeamento do linfonodo sentinela (MLNS) é largamente utilizado em pacientes com melanoma cutâneo, câncer de mama e outras neoplasias malignas sólidas com a finalidade de estadiá-las e indicar esvaziamento linfático apenas na presença de metástase. Nos últimos anos aumentou o interesse pelo uso do MLNS em pacientes com carcinoma papilífero de tireoide (CPT) sem metástases linfáticas detectáveis clinicamente (estádio cN0), devido à alta frequência de metástases ocultas nesses pacientes. O MLNS pode evitar o esvaziamento linfático do compartimento central (ECC) em portadores de CPT sem metástase. Mesmo que não se planeje o ECC eletivo, o MLNS pode também ser usado para estadiar adequadamente o pescoço e indicar tratamento posterior com radioiodoterapia em casos com metástase. Esse estudo tem como objetivo verificar: 1) a efetividade da técnica do MLNS nos pacientes com CPT; 2) a acurácia do MLNS em diagnosticar as metástases linfáticas; 3) se o MLNS pode modificar o estadiamento dos pacientes com CPT cN0. MÉTODOS: Trata-se de estudo de acurácia, prospectivo longitudinal de 38 casos consecutivos de CPT clinicamente N0, atendidos em um único centro, no período de 2010 a 2015. Todos foram submetidos à tireoidectomia total, MLNS com radiofármaco e ECC eletivo. Os resultados relativos ao MLNS foram comparados com o exame anatomopatológico do conteúdo do ECC. RESULTADOS: O tempo médio de seguimento dos doentes foi de 36 ± 13 meses. Os LNS foram localizados com maior frequência nos níveis VI e III. O LNS foi detectado em 95% da casuística e os valores de avaliação de testes diagnósticos foram: 1 falso negativo, 95% de sensibilidade, 100% de especificidade, 94% de valor preditivo negativo e 97% de acurácia. O MLNS foi capaz de reestadiar 49% dos pacientes inicialmente N0 para pN positivo. Quanto ao grupo de estadiamento AJCC (que leva em conta a idade), 3% dos pacientes foram reestadiados para estádio III e 18% para estádio IV. CONCLUSÕES: 1) a técnica de MLNS utilizada nos pacientes com CPT foi efetiva em 95% dos procedimentos realizados; 2) a acurácia do MLNS em diagnosticar as metástases linfáticas cervicais foi de 97%; 3) o MLNS re-estadiou os portadores de CPT, classificados clinicamente como N0, para pN positivo em 49% da casuística, e para estádio III e IVa em 21% / INTRODUCTON: Sentinel lymph node mapping (SLNM) is widely perfomed in melanoma, breast cancer and other solid tumors, to adequately stage these diseases. More recently, the interest in SLNM for clinically N0 Papillary Thyroid Cancer (PTC) has increased due to the high rate of occult metastases in these patients, to avoid unnecessary central neck dissection (CND), and its complications. Even if routine elective CND is not planned, SLNM can be used to adequately stage the neck, and to indicate further treatment with radioiodine in cases with neck metastases, for instance. This study aims to evaluate 1) SLNM effectiveness in PTC patients, 2) SLNM accuracy to diagnosis lymph node metastases and 3) if SLNM can upstage cN0 PTC patients. METHODS: This is a prospective longitudinal, diagnostic test accuracy study with 38 consecutive cN0 PTC patients, treated in a single center between 2010 and 2015. Surgical treatment in all cases included total thyroidectomy and elective CND after SLNM. Results of SLNM were compared to CND pathological findings, in order to verify if sentinel lymph node (SLN) predicted the occurrence of PTC occult lymph node metastasis. RESULTS: The mean patients\' follow-up was 36 ± 13 months. 133 SLN were found in the neck, on levels VI and III. The SLN was identified in 95% of the patients with 1 false negative, 95% sensitivity, 94% negative predictive value and 97% accuracy. The SLNM upstaging from cN0 to pN+ was 49%, with 3% stage III and 18% stage IVa. CONCLUSION: 1) SLNM was effective in 95% of procedures, 2) SLNM accuracy was 97%, 3) SLNM upstaging from cN0 to pN+ was 49%, and to stage III and IVa was 21%
|
19 |
Análise da qualidade de uma base de dados a a partir da implementação do Registro Paulista de Tratamento Cirúrgico de Câncer de Pulmão / Analysis a database quality through the implementation of the Paulista Lung Cancer Surgical Treatment RegistryLauricella, Letícia Leone 29 November 2017 (has links)
INTRODUÇÃO: O câncer de pulmão é a terceira neoplasia maligna mais frequentemente diagnosticada em todo o mundo e a primeira em termos de mortalidade. O tratamento cirúrgico é a melhor abordagem nos estágios iniciais, contudo, está associado a morbimortalidade considerável. Para que o impacto do tratamento cirúrgico na diminuição global da mortalidade pelo câncer de pulmão no estado de São Paulo seja maior, precisamos conhecer os indicadores de qualidade das instituições envolvidas no tratamento desta neoplasia, através da criação de uma base de dados abrangente, confiável e transparente. Este estudo envolveu a implementação do Registro Paulista de Tratamento Cirúrgico do Câncer de Pulmão (RPCP). O desfecho principal foi a análise da qualidade dos dados capturados através de um sistema de auditoria direta e indireta, com o intuito de identificar as variáveis com menor padrão de qualidade. MÉTODOS: Estudo prospectivo, multicêntrico, com participação de 10 instituições no estado de São Paulo. A auditoria dos dados foi realizada de forma direta por revisão dos prontuários, para análise da taxa de discordância, Coeficiente Kappa e Intraclass correlation e de forma indireta para análise dos índices de completude, acurácia e consistência. RESULTADOS: Dos 536 casos disponíveis, 511 foram incluídos para a auditoria indireta. O índice total de completude por questionário variou de 0,82 a 1, sendo que as seguintes variáveis obtiveram valor individual abaixo da meta estabelecida de 0,8: ECOG, MRC, hematócrito, potássio, uréia, creatinina, DHL, albumina, cálcio e FA, tempo de cirurgia e data da recidiva. O índice total de acurácia e consistência foi 0,99 e 0,96, respectivamente. Para auditoria direta foram randomizados 100 casos entre os 511 iniciais, sendo 4 excluídos, restando 96 para análise. As variáveis com maiores taxas de discordância ( > 20%), estavam no questionário de avaliação pré-operatória (ECOG, MRC, carga tabágica, DPOC, PFP, peso, altura, IMC e exames laboratoriais). Variáveis relacionadas ao estadiamento (tamanho da neoplasia, invasão de estruturas adjacentes, status linfonodal não invasivo) e dados cirúrgicos (tempo de cirurgia) também apresentaram taxas > 20%. CONCLUSÕES: A auditoria indireta dos dados mostrou índices de completude, acurácia e consistência aceitáveis para o padrão estabelecido e comparáveis a bancos de dados internacionais. Por outro lado, a auditoria direta, revelou algumas variáveis com altos índices de discordância, dados que serão analisados futuramente para aprimoramento do RPCP e que poderão contribuir para o desenvolvimento de outras bases de dados semelhantes / BACKGROUND: Lung cancer is the third malignant neoplasm most frequently diagnosed worldwide and the first in terms of mortality. Surgical treatment is the best approach in the initial stages; however, it\'s associated with considerable morbidity and mortality. In order to improve the surgical treatment global impact on lung cancer mortality in the state of Sao Paulo, we need to know the quality indicators of the institutions involved in the treatment of this neoplasm through the creation of a extensive, reliable and transparent database. The study involved the implementation of the Paulista Lung Cancer Registry (PLCR). The main outcome was the quality analysis of the data captured through a direct and indirect audit system, in order to identify the variables with the lowest quality standard. METHODS: A prospective, multicenter study with the participation of 10 institutions in the state of São Paulo. The data audit was performed directly, through the revision of medical registries, with the intention to analyze the discordance rate; and indirectly, with the intention to analyze the completeness, accuracy and consistency indexes. RESULTS: Of the 536 cases available, 511 were included for the indirect audit. The total completeness index per questionnaire ranged from 0.82 to 1, and the following variables had a in individual value bellow the established target of 0,8: ECOG, MRC, hematocrit, potassium, urea, creatinine, LDH, albumin, calcium, AF, surgical time, date of recurrence. The total accuracy and consistency index was 0.99 and 0.96, respectively. For direct audit, 100 cases were randomized among the initial 511, of which 4 were excluded, remaining 96 for analysis. The variables with the highest discordance rates ( > 20%) were in the preoperative evaluation questionnaire (ECOG, MRC, smoking rate, COPD, PFT, weight, high, BMI and lab tests). Variables related to staging (size of neoplasm, invasion of adjacent structures, noninvasive lymph node status) and surgical data (time of surgery) also presented rates > 20%. CONCLUSIONS: Regarding the established standards, the Indirect audit showed acceptable completeness, accuracy and consistency indices, comparable to international databases. On the other hand, the direct audit revealed some variables with high discordance indices, data that will be analyzed in the future for the improvement of the PLCR and that may contribute to the development of other similar databases
|
20 |
Comparação entre a acurácia de métodos não invasivos de fibrose e a biópsia hepática em pacientes com hepatite C crônica / Comparison of the accuracy of non-invasive fibrosis tests and liver biopsy in patients with chronic hepatitis CRagazzo, Taisa Grotta 15 December 2016 (has links)
A hepatite C é um processo inflamatório do tecido hepático que acomete milhões de pessoas em todo mundo. A evolução crônica da doença pode levar a transformação da fibrose hepática em cirrose e carcinoma hepatocelular em um grande número de casos. A avaliação dos graus de fibrose hepática é importante para o estudo da gravidade e progressão da doença, bem como decisão terapêutica e avaliação de sua eficácia. Os métodos não invasivos de avaliação da fibrose hepática têm sido uma opção aos possíveis riscos da biópsia hepática, ainda considerada o melhor método de avaliação de fibrose hepática. No presente trabalho, 107 pacientes portadores de hepatite C foram submetidos à biópsia hepática e Elastografia transitória hepática, 106 pacientes APRI e FIB4, ELF em 68 pacientes e ARFI em 51 pacientes. Usando a área abaixo da Curva ROC, AUROC, para obter a acurácia da fibrose hepática, encontramos na fibrose significativa ( >= F2): Elastografia transitória hepática: 0,83; FIB4: 0,76; ELF: 0,70; APRI: 0,69; ARFI: 0,67; na fibrose avançada ( >= F3): Elastografia transitória hepática: 0,85; ELF: 0,82; FIB4: 0,77; ARFI: 0,74; APRI: 0,71 e na cirrose ( >= F4) APRI: 1; FIB4: 1; Elastografia transitória hepática: 0,99; ARFI: 0,96; ELF: 0,94. Podemos dizer que em todos os graus de fibrose avaliados, a Elastografia transitória hepática foi o método que apresentou a melhor acurácia. Em se de tratando de cirrose (>=F4), todos os métodos não invasivos apresentam excelente acurácia. Utilizando o método Obuchowski, encontramos em cada grau de fibrose hepática classificado pelo escore METAVIR as acurácias: F1= Elastografia transitória hepática: 0,81; ARFI: 0,78; APRI: 0,72; FIB4: 0,67; ELF: 0,44; F2= Elastografia transitória hepática: 0,73; FIB4: 0,68; ELF: 0,63; APRI: 0,60; ARFI: 0,53; F3= ELF: 0,77; Elastografia transitória hepática: 0,70; FIB4: 0,67; ARFI: 0,64; APRI: 0,60 e F4: APRI e FIB4: 1; Elastografia transitória hepática: 0,98; ARFI: 0,96; ELF: 0,82. A Elastografia transitória hepática se mantém como um método eficiente para todos os graus de fibrose, sendo que nos extremos apresenta discreta superioridade em relação aos graus intermediários. A acurácia de todos os métodos é superior em F4 / Hepatitis C is an inflammatory condition of the hepatic tissue that affects millions worldwide. The chronic stages of the disease turns from hepatic fibrosis into cirrhosis and hepatocellular carcinoma in many cases. The evaluation of fibrosis staging is important for prognosis, as well as understanding the progression of the disease, choice of treatment options and assessing their effectiveness. Non-invasive methods of fibrosis assessment have increasingly become alternatives to liver biopsy, which is still considered the best method of fibrosis assessment. In this study, 107 consecutive patients with hepatitis C virus were submitted to liver biopsy and transient elastography, 106 underwent APRI and FIB-4, 68 underwent ELF and 51 underwent ARFI. Using the area under ROC curve (AUROC) to obtain the degree of accuracy of each test, the following cutoffs were found for significant fibrosis (F >= 2): transient elastography: 0,83; FIB4: 0,76; ELF: 0,70; APRI: 0,69; ARFI: 0,67; For advanced fibrosis (F>=3): transient elastography: 0,85; ELF: 0,82; FIB4: 0,77; ARFI: 0,74; APRI: 0,71; For cirrhosis (F >= 4): APRI: 1; FIB4: 1; transient elastography: 0,99; ARFI: 0,96; ELF: 0,94. Of the methods assessed, transient elastography presented the greatest diagnostic accuracy across all levels of fibrosis. When assessing cirrhosis (F>= 4), all of these non-invasive methods showed excellent diagnostic accuracy. Using the Obuchowski method, the accuracy of each degree of fibrosis categorised by the METAVIR score was determined: F1= transient elastography: 0,81; ARFI: 0,78; APRI: 0,72; FIB4: 0,67; ELF: 0,44; F2=transient elastography: 0,73; FIB4: 0,68; ELF: 0,63; APRI: 0,60; ARFI: 0,53; F3= ELF: 0,77; transient elastography: 0,70; FIB4: 0,67; ARFI: 0,64; APRI: 0,60; F4: APRI and FIB4: 1; transient elastography: 0,98; ARFI: 0,96; ELF: 0,82. Transient elastography remained the most effective method for all degrees of fibrosis, although at the higher levels this superiority was less than at the intermediate levels. The accuracy of all methodologies was best at F >= 4
|
Page generated in 0.0399 seconds