Microspheres for bone regeneration and localised delivery of enzymes

Barrias, Cristina Carvalho January 2005 (has links)
Tese de mestrado. Faculdade de Engenharia. Universidade do Porto. 1998
2

Comparação da precisão e acurácia de medidas lineares com diferentes protocolos de tomografia computadorizada por feixe cônico / Comparison of accuracy and precision of linear measurements with different cone beam computed tomographic protocols

Kim, Jun Ho 25 May 2018 (has links)
Uma das complicações mais importantes relacionadas com o tratamento de implante dentário é a peri-implantite. Devido a limitação pela sobreposição de estruturas da técnica periapical, nos casos da perda óssea peri-implantar nas faces vestibulares e linguais ou palatais necessita-se de um exame capaz de prover imagens em 3 dimensões para o correto diagnóstico, sendo as imagens de tomografia computadorizada por feixe cônico (TCFC) as mais indicadas. O objetivo deste estudo foi avaliar a acurácia, especificidade, sensibilidade, concordância inter e intraobservadores e determinar a influência dos artefatos na detecção dos defeitos ósseos peri-implantares simulados em mandíbulas humanas edêndulas secas. Foram utilizados dois aparelhos de TCFC com diferentes protocolos de aquisição: i-CAT Gendex CB-500(120kVp, 5mA) e ORTHOPANTOMOGRAPH OP300(90kVp, 6.3mA). Foram instalados 24 implantes dentários cilíndricos e executados dezesseis defeitos somente nas faces vestibulares, com os comprimentos que variaram de 0,5mm a 15mm. Somente cortes sagitais foram utilizados para avaliação qualitativa e quantitativa dos defeitos foi realizada por meio de Image J. Os resultados do teste de concordância intra e inter-observadores tanto nas avaliações qualitativas e quantitativas foram predominantemente fracos. Os valores de Área Sob a Curva (ASC) variaram de 0.51 a 0.72 no i-CAT Gendex CB-500; e no ORTHOPANTOMOGRAPH OP300 variaram de 0.54 a 0.75, demonstrando desempenho diagnóstico ligeiramente superior. Nas imagens obtidas em aparelho com 120kVp (i-CAT Gendex CB-500) foram observados maior contraste em relação ao aparelho 90kVp (ORTHOPANTOMOGRAPH® OP300); em aparelho com o menor kVp (OP300) formaram mais artefatos e estes, degradaram a qualidade das imagens e influenciaram o desempenho diagnóstico das TCFCs na detecção e nas mensurações de perda óssea peri-implantar. Os protocolos de aquisições diferentes podem influenciar no aumento ou redução da formação dos artefatos. / One of the most important complications related to dental implant treatment is periimplantitis. Due to the structures overlapping inherited to periapical technique, in cases of buccal and lingual or palatal bone loss in peri-implantitis, the 3 dimensions observation exam like cone beam computed tomography(CBCT) is most indicated. The objective of this study was to evaluate the accuracy, specificity, sensitivity, interand intra-observer agreement and to determine the influence of the artifacts in the detection of the peri-implant bone defects simulated in human dry mandibles. The two CBCT devices with different acquisition protocols were used in this study: i-CAT Gendex CB-500 (120kVp, 5mA) and ORTHOPANTOMOGRAPH OP300 (90kVp, 6.3mA). Twenty-four cylindrical dental implants were placed and 16 defects were prepared only on buccal faces, the defect lengths ranged from 0.5mm to 15mm. For qualitative and quantitative assessment, only sagittal slices were evaluated by the observers, using Image J software. The results of intra and inter-observer agreement tests in both assessments were generally poor. The AUC values ranged from 0.51 to 0.72 on the i-CAT Gendex CB-500; and in the ORTHOPANTOMOGRAPH OP300 ranged from 0.54 to 0.75, showing slightly higher diagnostic performance. Higher contrast was observed in the 120 kVp device\'s images (i-CAT Gendex CB-500) when compared with the 90 kVp device\'s image (ORTHOPANTOMOGRAPH® OP300). The low kVp device (OP300), formed more artifacts which degraded the image quality and influenced the CBCT diagnostic performance in the detection and measurement of peri-implant bone loss. Different CBCT acquisition protocols may influence increasing or reducing artefact formation.
3

Avaliação de microesferas de hidroxiapatita, dopadas ou não com estrôncio, no reparo de defeito ósseo crítico, em calvária de rato

Rolim, Ana Emília Holanda January 2010 (has links)
91f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T13:36:16Z No. of bitstreams: 1 Dissertacao Ana Emilia.pdf: 3842407 bytes, checksum: 06b8d72eed292f7ebdf42b0a223ed0f6 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:44:00Z (GMT) No. of bitstreams: 1 Dissertacao Ana Emilia.pdf: 3842407 bytes, checksum: 06b8d72eed292f7ebdf42b0a223ed0f6 (MD5) / Made available in DSpace on 2013-05-08T11:44:00Z (GMT). No. of bitstreams: 1 Dissertacao Ana Emilia.pdf: 3842407 bytes, checksum: 06b8d72eed292f7ebdf42b0a223ed0f6 (MD5) Previous issue date: 2010 / A bioengenharia tecidual tem possibilitado o desenvolvimento de biomateriais e técnicas inovadoras capazes de restituir a qualidade de vida aos pacientes com perdas ósseas, após a remoção de grandes tumores ósseos, traumas e em algumas doenças metabólicas. Dentre os biomateriais empregados nas terapias regenerativas destacam-se as biocerâmicas sintéticas, na forma de microesferas. Estas microesferas constituem um arcabouço que possibilita, no interstício formado entre as esferas, a difusão de fatores de crescimento e angiogênicos, a migração de cálulas osteogênicas essenciais à regeneração deste tecido. Ainda apresentam características físico-químicas semelhantes ao componente inorgânico do tecido ósseo e biocompatibilidade. O objetivo deste trabalho foi avaliar a regeneração de defeitos ósseos críticos, em calvária de rato. Para tanto, utilizou-se uma amostra composta de 60 animais, dividida em quatro grupos: Gl - defeito sem biomaterial, preenchido por coágulo; Gll - microesferas de hidroxiapatita e alginato (HA - Alg); Glll - microeferas de hidroxiapatita dopadas com estrôncio (HASr); GlV - microesferas de hidroxiapatita dopadas com estrôncio e alginato (HASr -Alg), avaliados aos 15, 45 e 120 dias de pós operatório. As análises histológicas, por microscopia de luz, demonstraram neoformação óssea mais evidente no grupo Gll em todos os pontos biológicos quando comparado aos demais grupos. As microesferas implantadas nos grupos lll e lV apresentaram maior fragmentação quando comparadas com as do grupo ll, provavelmente devido à adição de estrôncio à estrutura da HA. A neoformação óssea caracterizada pela osteocondução foi observada de permeio a esses fragmentos do biomaterial. No grupo lll, a ausência do alginato tornou as microesferas mais porosas, com formação de septos de tecido conjuntivo e células fusiformes no interior das microesferas. Em conclusão, os biomateriais apresentaram potencial osteogênico e osteocondutor formando um arcabouço tridimensional que favoreceu a neoformação óssea. A HA associada ao alginato apresentou características histológicas mais evidentes quanto a biocompatibilidade e a osteogênese, quando comparada a HA dopada com estrôncio. / Salvador
4

Comparação da precisão e acurácia de medidas lineares com diferentes protocolos de tomografia computadorizada por feixe cônico / Comparison of accuracy and precision of linear measurements with different cone beam computed tomographic protocols

Jun Ho Kim 25 May 2018 (has links)
Uma das complicações mais importantes relacionadas com o tratamento de implante dentário é a peri-implantite. Devido a limitação pela sobreposição de estruturas da técnica periapical, nos casos da perda óssea peri-implantar nas faces vestibulares e linguais ou palatais necessita-se de um exame capaz de prover imagens em 3 dimensões para o correto diagnóstico, sendo as imagens de tomografia computadorizada por feixe cônico (TCFC) as mais indicadas. O objetivo deste estudo foi avaliar a acurácia, especificidade, sensibilidade, concordância inter e intraobservadores e determinar a influência dos artefatos na detecção dos defeitos ósseos peri-implantares simulados em mandíbulas humanas edêndulas secas. Foram utilizados dois aparelhos de TCFC com diferentes protocolos de aquisição: i-CAT Gendex CB-500(120kVp, 5mA) e ORTHOPANTOMOGRAPH OP300(90kVp, 6.3mA). Foram instalados 24 implantes dentários cilíndricos e executados dezesseis defeitos somente nas faces vestibulares, com os comprimentos que variaram de 0,5mm a 15mm. Somente cortes sagitais foram utilizados para avaliação qualitativa e quantitativa dos defeitos foi realizada por meio de Image J. Os resultados do teste de concordância intra e inter-observadores tanto nas avaliações qualitativas e quantitativas foram predominantemente fracos. Os valores de Área Sob a Curva (ASC) variaram de 0.51 a 0.72 no i-CAT Gendex CB-500; e no ORTHOPANTOMOGRAPH OP300 variaram de 0.54 a 0.75, demonstrando desempenho diagnóstico ligeiramente superior. Nas imagens obtidas em aparelho com 120kVp (i-CAT Gendex CB-500) foram observados maior contraste em relação ao aparelho 90kVp (ORTHOPANTOMOGRAPH® OP300); em aparelho com o menor kVp (OP300) formaram mais artefatos e estes, degradaram a qualidade das imagens e influenciaram o desempenho diagnóstico das TCFCs na detecção e nas mensurações de perda óssea peri-implantar. Os protocolos de aquisições diferentes podem influenciar no aumento ou redução da formação dos artefatos. / One of the most important complications related to dental implant treatment is periimplantitis. Due to the structures overlapping inherited to periapical technique, in cases of buccal and lingual or palatal bone loss in peri-implantitis, the 3 dimensions observation exam like cone beam computed tomography(CBCT) is most indicated. The objective of this study was to evaluate the accuracy, specificity, sensitivity, interand intra-observer agreement and to determine the influence of the artifacts in the detection of the peri-implant bone defects simulated in human dry mandibles. The two CBCT devices with different acquisition protocols were used in this study: i-CAT Gendex CB-500 (120kVp, 5mA) and ORTHOPANTOMOGRAPH OP300 (90kVp, 6.3mA). Twenty-four cylindrical dental implants were placed and 16 defects were prepared only on buccal faces, the defect lengths ranged from 0.5mm to 15mm. For qualitative and quantitative assessment, only sagittal slices were evaluated by the observers, using Image J software. The results of intra and inter-observer agreement tests in both assessments were generally poor. The AUC values ranged from 0.51 to 0.72 on the i-CAT Gendex CB-500; and in the ORTHOPANTOMOGRAPH OP300 ranged from 0.54 to 0.75, showing slightly higher diagnostic performance. Higher contrast was observed in the 120 kVp device\'s images (i-CAT Gendex CB-500) when compared with the 90 kVp device\'s image (ORTHOPANTOMOGRAPH® OP300). The low kVp device (OP300), formed more artifacts which degraded the image quality and influenced the CBCT diagnostic performance in the detection and measurement of peri-implant bone loss. Different CBCT acquisition protocols may influence increasing or reducing artefact formation.
5

Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribs

Pinheiro, Lucas Rodrigues 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
6

Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribs

Lucas Rodrigues Pinheiro 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
7

Avaliação de defeitos ósseos alveolares artificiais utilizando radiografia digital direta e tomografia computadorizada por feixe cônico / Assessment of artificially created alveolar bone defects using direct digital radiography and cone beam computed tomography

Campos Junior, Adinilton Ferraz de 31 October 2008 (has links)
Introdução A abordagem do estudo dos recursos imaginológicos aplicados à análise óssea diz respeito ao estudo topográfico do periodonto e suas alterações. Consiste em avaliar a contribuição dos referidos recursos em razão das limitações dos exames convencionais. Objetivo Analisar por meio de dois sistemas de imagens digitais: a radiografia digital direta e a tomografia computadorizada por feixe cônico, comparando a eficácia de cada aparelho na análise das corticais do tecido periodontal e suas alterações. Métodos Cinco espécimes de mandíbulas foram incluídos em nosso estudo, com 6 tipos de defeitos ósseos distribuídos no septo interdentário e na porção radicular do dente. Radiografias periapicais foram realizadas, com o sensor sensor Dixi®2 (Planmeca Oy, Helsinki, Finlândia), e exames tomográficos, com o aparelho Newtom 3G (QR Srl, Verona, Itália). A pesquisa qualitativa, de caráter subjetivo, contemplou a análise das corticais ósseas avaliadas por três observadores em um total de 40 sítios para cada modalidade de exame. Teste estatístico de McNemar foi empregado para análise inter e intraobservadores. Resultados Resultados não concordantes foram relacionados à sobreposição de estruturas anatômicas em sua maior parte pela radiografia digital direta. Os resultados de acerto da tomografia computadorizada por feixe cônico: para análise da cortical vestibular do septo interdentário foi de 84%; para a cortical lingual de 92%; para a cortical proximal de 80%; e para cortical radicular de 80%, contra 60%, 64%, 80% e 46% respectivamente da radiografia digital. Não foram encontradas diferenças entre a 1ª e a 2ª análises na avaliação intra-observadores, contudo houve variação inter-observadores. Conclusões A tomografia computadorizada por feixe cônico mostrou-se como potencial recurso de imagem para análise das corticais ósseas do tecido periodontal. Entretanto, os resultados também apontaram que ambos os métodos são observador-dependentes, havendo necessidade de profissionais habilitados para utilização desses recursos recentes de imagem. Também avaliamos que estudos adicionais deveriam ser aplicados para maior entendimento do assunto estudado. / Introduction The study of the imaging resources applied to bone analysis regards to the topographic study of the periodontium and its changes. It is an assessment of the contribution of the related resources as compared to the limitations of conventional exams. Objective To analyze two digital imaging systems: the direct digital radiography and the cone beam computed tomography, comparing the efficacy of each device to analyze the cortical plates of the periodontal tissue and its changes. Methods Five mandible specimens were included in our study, with 6 types of bone defects distributed on the interdental septum and on the radicular portion of the tooth. Periapical radiographs with the Dixi®2 sensor (Planmeca Oy, Helsinki, Finland) and tomographic scans with Newtom 3G device (QR Srl, Verona, Italy) were obtained. The qualitative research, with a subjective feature, included the analysis of the bone cortical plates for a total of 40 sites with each examination method carried out by three observers. The McNemar statistic test was used for inter and intraobserver analyses. Results Results which did not agree were related to the overlay of anatomic structures mainly due to the direct digital radiography. The correct results for cone beam computed tomography were: 84% for the analysis of vestibular cortical plate of the interdental septum; 92% for lingual cortical plate; 80% for proximal cortical plate; and 80% for radicular cortical plate, against 60%, 64%, 80% e 46%, respectively, with digital radiography. No differences were found between the 1st and 2nd intraobserver analyses, but there was interobserver variation. Conclusion The cone beam computed tomography was shown to be a potential imaging resource for the analysis of the bone cortical plates of the periodontal tissue. However, the results also showed that both methods are observer-dependent, and there is a need for skilled professionals to use this recent imaging technology. In addition, we considered the additional studies that should be applied to improve the understanding of this subject.
8

Avaliação de defeitos ósseos alveolares artificiais utilizando radiografia digital direta e tomografia computadorizada por feixe cônico / Assessment of artificially created alveolar bone defects using direct digital radiography and cone beam computed tomography

Adinilton Ferraz de Campos Junior 31 October 2008 (has links)
Introdução A abordagem do estudo dos recursos imaginológicos aplicados à análise óssea diz respeito ao estudo topográfico do periodonto e suas alterações. Consiste em avaliar a contribuição dos referidos recursos em razão das limitações dos exames convencionais. Objetivo Analisar por meio de dois sistemas de imagens digitais: a radiografia digital direta e a tomografia computadorizada por feixe cônico, comparando a eficácia de cada aparelho na análise das corticais do tecido periodontal e suas alterações. Métodos Cinco espécimes de mandíbulas foram incluídos em nosso estudo, com 6 tipos de defeitos ósseos distribuídos no septo interdentário e na porção radicular do dente. Radiografias periapicais foram realizadas, com o sensor sensor Dixi®2 (Planmeca Oy, Helsinki, Finlândia), e exames tomográficos, com o aparelho Newtom 3G (QR Srl, Verona, Itália). A pesquisa qualitativa, de caráter subjetivo, contemplou a análise das corticais ósseas avaliadas por três observadores em um total de 40 sítios para cada modalidade de exame. Teste estatístico de McNemar foi empregado para análise inter e intraobservadores. Resultados Resultados não concordantes foram relacionados à sobreposição de estruturas anatômicas em sua maior parte pela radiografia digital direta. Os resultados de acerto da tomografia computadorizada por feixe cônico: para análise da cortical vestibular do septo interdentário foi de 84%; para a cortical lingual de 92%; para a cortical proximal de 80%; e para cortical radicular de 80%, contra 60%, 64%, 80% e 46% respectivamente da radiografia digital. Não foram encontradas diferenças entre a 1ª e a 2ª análises na avaliação intra-observadores, contudo houve variação inter-observadores. Conclusões A tomografia computadorizada por feixe cônico mostrou-se como potencial recurso de imagem para análise das corticais ósseas do tecido periodontal. Entretanto, os resultados também apontaram que ambos os métodos são observador-dependentes, havendo necessidade de profissionais habilitados para utilização desses recursos recentes de imagem. Também avaliamos que estudos adicionais deveriam ser aplicados para maior entendimento do assunto estudado. / Introduction The study of the imaging resources applied to bone analysis regards to the topographic study of the periodontium and its changes. It is an assessment of the contribution of the related resources as compared to the limitations of conventional exams. Objective To analyze two digital imaging systems: the direct digital radiography and the cone beam computed tomography, comparing the efficacy of each device to analyze the cortical plates of the periodontal tissue and its changes. Methods Five mandible specimens were included in our study, with 6 types of bone defects distributed on the interdental septum and on the radicular portion of the tooth. Periapical radiographs with the Dixi®2 sensor (Planmeca Oy, Helsinki, Finland) and tomographic scans with Newtom 3G device (QR Srl, Verona, Italy) were obtained. The qualitative research, with a subjective feature, included the analysis of the bone cortical plates for a total of 40 sites with each examination method carried out by three observers. The McNemar statistic test was used for inter and intraobserver analyses. Results Results which did not agree were related to the overlay of anatomic structures mainly due to the direct digital radiography. The correct results for cone beam computed tomography were: 84% for the analysis of vestibular cortical plate of the interdental septum; 92% for lingual cortical plate; 80% for proximal cortical plate; and 80% for radicular cortical plate, against 60%, 64%, 80% e 46%, respectively, with digital radiography. No differences were found between the 1st and 2nd intraobserver analyses, but there was interobserver variation. Conclusion The cone beam computed tomography was shown to be a potential imaging resource for the analysis of the bone cortical plates of the periodontal tissue. However, the results also showed that both methods are observer-dependent, and there is a need for skilled professionals to use this recent imaging technology. In addition, we considered the additional studies that should be applied to improve the understanding of this subject.