• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • Tagged with
  • 59
  • 59
  • 31
  • 13
  • 12
  • 10
  • 10
  • 9
  • 9
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise comparativa por meio da densidade óptica radiográfica entre o grau de osteopenia induzida pela fenitoína e ausência hormonal em ratos

Àgreda, Carola Gomez [UNESP] 24 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-24Bitstream added on 2014-06-13T18:38:55Z : No. of bitstreams: 1 agreda_cg_me_sjc.pdf: 492552 bytes, checksum: 595c43ac7e6868cedfc37076598974b1 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Por ser a osteoporose uma enfermidade de alta prevalência mundial, tem-se a importância de estudos que avaliem a repercussão óssea proveniente de supressão hormonal, como também de influência de fármacos. Em vista disto, a proposta desta pesquisa foi realizar a comparação radiográfica mediante a avaliação da densidade óptica em tons de cinza, entre o grau de osteopenia induzida por um fármaco e pela castração de ratos em dois períodos (trinta e sessenta dias). Utilizou-se 37 ratos adultos que foram divididos em: grupo I, com 5 fêmeas sham; grupo II, com 5 machos sham; grupo III, com 6 fêmeas ovariectomizadas; grupo IV, com 6 machos orquiectomizados; grupo V, com 8 fêmeas tratadas com fenitoína a 5mg/kg/dia e grupo VI, com 7 machos tratados com fenitoína a 5mg/kg/dia. Realizou-se a radiografia da tíbia esquerda de todos os grupos no período inicial, trinta e sessenta dias após o procedimento cirúrgico. Para isso foi utilizado o aparelho de raios X digital Gendex 765DC®, com 0,032s de tempo de exposição, distância focal de 40cm, 65kVp, 7mA, com feixe incidindo perperdicularmente ao sensor do sistema digital direto RVG (Trophy). A partir das imagens obtidas realizou-se a mensuração dos valores de densidade óptica de duas áreas selecionadas da tíbia (metáfise e diáfise) mediante a ferramenta histograma do programa Adobe Photoshop®. As médias das leituras de densidade óptica foram submetidas à análise de variância (ANOVA) e teste Tukey (5%). De acordo com os resultados obtidos, concluiu-se que não houve diferenças estatisticamente significantes nos valores de densidade óptica no método de indução à osteopenia pela ovariectomia ou orquidectomia, ao passo que, na indução pela fenitoína houve a indicação da sua ocorrência tanto em machos quanto em fêmeas depois de 60 dias na região da diáfise. / The aim of this research was to compare the osteopenia degree induced by phenytoin with the castration in rats for thirty and sixty days. Thirty seven rats were divided into six experimental groups: five Sham female (I); five Sham male (II); six female ovariectomy-operated (III); six male orchidectomy-operated (IV); eight female phenytoin-treated with 5mg/kg/day (V) and seven male phenytointreated with 5mg/kg/day. Digital radiographs were taken at baseline, thirty and sixty days from the left tibiae of the all groups. The X-Ray machine used was the 765 DC® with 65 kVp, 7mA, 40 cm distance focus- sensor and exposure time of the 0,032s. The direct digital device used was the RVG® (Trophy) and the values of the optical density were obtained from metaphysis and diaphysis tibial using the histogram of the software Adobe Photoshop. The measurements were submitted to ANOVA and Tukey test (5%). The results showed no possess statistically significant difference between ovariectomy-treated and orchidectomytreated groups from osteopenia induced, however, the phenytoin medication indicates this situation in male and female for diaphysis tibial at sixty days.
2

Avaliação da integridade da união de chapas navais por soldagem com alto grau de distorção utilizando radiografia digital

LUNDGREN, Edwin Althor Jurgem Nieling 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:37:15Z (GMT). No. of bitstreams: 2 arquivo2227_1.pdf: 12586595 bytes, checksum: ad8daed1f7d07dd24dca08290d9eadc0 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Na Construção Naval o campo de soldagem ocupa um lugar de elevada importância pela quantidade de serviços de soldagem elaborados em todo tipo de embarcação de aço. Uma eterna problemática inerente à solda é o fenômeno de distorções oriundas das soldas, efeito indesejável e que causa elevados custos para corrigi-los. A resistência de grandes estruturas como plataformas marítimas e navios depende fundamentalmente de soldas bem elaboradas e por isso há grande necessidade de controlar a qualidade de soldas em Chapas Navais. Este controle é feito por vários tipos de Ensaios Destrutivos e, principalmente, Ensaios Não Destrutivos. Dentre os Ensaios Não Destrutivos se destaca a tecnologia de Radiografia. Desde a descoberta dos raios-X as doses respectivamente os tempos de exposição vem sendo diminuídos gradativamente, sendo que houve um grande progresso com a introdução da Radiografia Digital utilizando os Imaging Plates. A tecnologia utilizada até os meados dos anos 90 não conseguia propor uma qualidade equivalente à radiografia tradicional utilizando filmes susceptíveis à raio-X. Porém hoje em dia a qualidade de radiografias feitas com Imaging Plates têm qualidade equivalentes ou superior daquelas feitas com filmes convencionais. Iniciou-se o desenvolvimento de mais outra tecnologia, de ultra-alta resolução, denominada Digital Detector Array (DDA), que proporciona definitivamente qualidade de imagem superior às imagens concebidas por filmes de radiografia tradicional. O trabalho agora apresentado mostra uma comparação entre os métodos de obtenção de radiografias industriais, Radiografia tradicional com filmes e Imaging Plate (Radiografia Digital). Para isto foram radiografadas chapas soldadas de aço utilizado na indústria naval. De forma geral o processo de soldagem industrial pode gerar diversos tipos de tensões residuais no material soldado, sendo que em alguns casos extremos torna-se necessário algum tratamento térmico tanto antes como após a soldagem. Os parâmetros que definem se há necessidade ou não de tratamentos térmicos são altamente complexos incluindo a energia utilizada na soldagem, processos, liga do material base (neste caso as chapas), material de adição, qualificação do e experiência do operário de soldagem. O objetivo é buscar novas técnicas de obtenção de imagens de radiografia industrial digital, e o processamento dessas imagens utilizando softwares como o MATLABe o ISee!, com o pacote de ferramentas do IPT (Image Processing Toolboxe), e o MEM (Maximum Entropy Method), um método de tratamento disponível em softwares comerciais. Para obtenção das imagens, foram usados filmes IP (Imaging Plate) e um scanner laser. A fonte de raios-X usada foi do tipo portátil de 120kV. Através da imagem radiográfica pode-se observar com maior nitidez o defeito na região de solda. Alguns tipos de defeitos podem provocar a formação e propagação de trincas e o consecutivo colapso da estrutura naval. Após comprovação dos métodos passou-se a análise de radiografias digitais do cordão de solda de uma chapa naval a qual foi radiografada com diversos parâmetros, e, por conseguinte aplicaram-se os métodos de manipulação de radiografias fornecido pelo software ISee, de uma forma mais direta, identificando e dimensionando os defeitos encontrados
3

Estudo Comparativo do Método Radiográfico Utilizando Filmes de Diferentes Sensibilidades e o Sistema Digital Digora, no Diagnóstico de Lesões de Cárie em Superfície Proximal de Molares Decíduos.

Tovo, Maximiano Ferreira 29 June 1998 (has links)
Este estudo comparou o desempenho diagnóstico dos filmes Agfa M2 e Ektaspeed plus e do sistema digital Digora. A amostra foi composta por 37 molares decíduos, os quais foram radiografados em 50, 70 e 90 kV. As imagens de 41 superfícies proximais foram avaliadas sob condições padronizadas. Cinco recursos de edição de imagem (x0,5, x1, x2, Negativo e 3D), disponíveis no software do sistema digital, foram utilizados. Após a secção dos dentes e a validação em estereomicroscopia (x40), calculou-se a sensibilidade, especificidade, acurácia e kappa não-ponderado dos métodos. O filme Agfa M2, exposto a 90 kV, e o Ektaspeed plus, a 50 kV, diferenciaram-se devido aos valores expressos para sensibilidade, acurácia e kappa não-ponderado. A especificidade dos filmes revelou valores comparáveis, nos dois cut-off estudados. A sensibilidade do sistema digital Digora alcançou maior valor ao ser utilizado o recurso de imagem Negativo. A imagem comprimida (x0,5) foi, majoritariamente, a mais específica. As acurácias médias do sistema digital Digora resultaram em valores aproximados. A estatística kappa, no diagnóstico de todas as lesões, fez distinção aos recursos x0,5, x1 e Negativo; no diagnóstico de lesões dentinárias, todas as modalidades de imagem expressaram concordância boa. O método digital foi mais sensível que os filmes, porém estes, no diagnóstico de lesões dentinárias, foram mais específicos. A acurácia média do sistema digital suplantou a dos filmes, em todos os kV, nos dois cut-off estudados, sendo as diferenças numéricas menores no diagnóstico de lesões dentinárias. Os valores de kappa obtidos pelos filmes assemelharam-se aos de algumas modalidades de imagem do sistema digital Digora, no diagnóstico de todas as lesões; excetuando-se o Ektaspeed, em 50 kV, os filmes não alcançaram os valores de kappa revelados pelo sistema digital, no diagnóstico de lesões dentinárias. Cohen’s kappa revelou boa concordância intra-examinador (0,758). O sistema digital estudado revelou-se comparável ao método radiográfico convencional, no diagnóstico de lesões de cárie em superfícies proximais de molares decíduos. / This study evaluated the diagnostic performance of Agfa M2 and Ektaspeed plus dental films and Digora digital system. The material comprised 37 extracted primary molars and it was exposed at 50, 70 and 90 kV. The images of 41 proximal surfaces were examined under standardised conditions. Five imaging modes (x0,5, x1, x2, Negative and 3D) included in digital system software, were used. The teeth were sectioned and observed under a stereomicroscope (x40). The data were analysed by means of sensitivity, specificity, accuracy and unweighted kappa. Agfa M2 exposed at 90 kV and Ektaspeed plus at 50 kV obtained higher sensitivity, accuracy and kappa values. Films specificity were comparable, in both cut-off. Digora sensitivity demonstrated high values using the Negative mode. The x0,5, in the majority, revealed the highest specificity. Average accuracy of digital system were very similar. The x0,5, x1 and Negative mode showed good agreement with the gold standard, for all lesions diagnostic. In the dentine lesions cut-off, all the modes established good agreement. The digital system sensitivity values were higher than the conventional films, but films revealed higher values for specificity, specially for dentine lesions detection. Digora accuracy average values were higher than the films, in any kilovoltage and both cut-off, but the differences were smaller in dentine caries diagnostic. The films unweighted kappa values were the same of some image mode, in all caries diagnostic; except for Ektaspeed plus, at 50 kV, films didn’t get Digora kappa values in dentine diagnostic. Cohen’s kappa showed good intraexaminer reliability (0,758). Digital system appeared comparable with the conventional radiographic method in proximal primary molars caries diagnostic.
4

Avaliação do efeito da formalina na descalcificação de espécimes anatômicos, por meio da densidade radiográfica e concentração de cálcio

Fonseca, Alisson André Robe January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:05Z (GMT). No. of bitstreams: 2 000397720-0.pdf: 4377048 bytes, checksum: c1288fe9b91b7ca21ccf4b256a0d7226 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of the present study was to determine if the process of preserving anatomic specimens in aqueous 10% formalin alters the radiographic density of tissues, and if fixation causes changes in tissue calcium levels as well. Twenty hemi-heads, 20 hindlimbs and 20 radius/ulna bones of rabbits were distributed individually in containers with one of the following aqueous fixatives: 10% formalin and 10% phosphate-buffered formalin (FTFA). The specimens were radiographed at five different times: before being added to fixative solutions (time zero) and after 1, 15, 30 and 90 days in fixative. The radiographs were digitized and analyzed using the ImageTool® program in pre-established regions. Samples of the fixatives were submitted to spectrophotometry to measure the concentration of calcium, before fixation and 90 days afterward. There was no significant difference in radiographic density between the specimens fixed in 10% formalin versus 10% phosphate buffered formalin. Radiographic density did decrease significantly with time in both fixatives. It can therefore be concluded that a progressive process of demineralization occurs in formalin. With regard to soft tissues, there was no evidence of any effect on radiographic density for the different time periods examined. At 90 days, the presence of calcium was observed in both fixatives, where a greater concentration was found in the 10% formalin group. / O presente estudo teve por objetivo verificar se o processo de conservação de espécimes anatômicos em solução aquosa de formalina a 10% altera a densidade radiográfica dos tecidos, bem como se há modificação da dosagem de cálcio durante a fixação. Para tanto, 20 hemicabeças, 20 membros pélvicos e 20 conjuntos rádio/ulna de coelhos foram distribuídos cada um em um recipiente contendo um dos seguintes fixadores: solução aquosa de formalina a 10% e solução aquosa de formalina a 10% com tampão-fosfato (FTFA). As peças foram radiografadas em cinco tempos diferentes: antes de serem acondicionadas nas soluções fixadoras (tempo zero) e um, 15, 30 e 90 dias após. As radiografias foram digitalizadas e analisadas por meio do programa ImageTool®, em regiões pré-estabelecidas. Amostras das substâncias fixadoras foram submetidas a espectrofotometria para a verificação e dosagem da concentração de cálcio, antes da fixação e 90 dias após. Não houve diferença significativa da densidade radiográfica entre os espécimes acondicionados em solução de formalina a 10% e formalina a 10% com tampãofosfato. A densidade radiográfica do tecido ósseo diminuiu significativamente com o passar do tempo em ambas as soluções fixadoras. Isto nos permite concluir que ocorre um processo progressivo de desmineralização. Em relação ao tecido mole não foi evidenciado efeito algum sobre a densidade radiográfica nos diferentes tempos de análise. Aos noventa dias verificou-se a presença de cálcio em ambas soluções fixadoras, sendo que a maior concentração ocorreu no grupo da Formalina à 10%.
5

Estudo Comparativo do Método Radiográfico Utilizando Filmes de Diferentes Sensibilidades e o Sistema Digital Digora, no Diagnóstico de Lesões de Cárie em Superfície Proximal de Molares Decíduos.

Maximiano Ferreira Tovo 29 June 1998 (has links)
Este estudo comparou o desempenho diagnóstico dos filmes Agfa M2 e Ektaspeed plus e do sistema digital Digora. A amostra foi composta por 37 molares decíduos, os quais foram radiografados em 50, 70 e 90 kV. As imagens de 41 superfícies proximais foram avaliadas sob condições padronizadas. Cinco recursos de edição de imagem (x0,5, x1, x2, Negativo e 3D), disponíveis no software do sistema digital, foram utilizados. Após a secção dos dentes e a validação em estereomicroscopia (x40), calculou-se a sensibilidade, especificidade, acurácia e kappa não-ponderado dos métodos. O filme Agfa M2, exposto a 90 kV, e o Ektaspeed plus, a 50 kV, diferenciaram-se devido aos valores expressos para sensibilidade, acurácia e kappa não-ponderado. A especificidade dos filmes revelou valores comparáveis, nos dois cut-off estudados. A sensibilidade do sistema digital Digora alcançou maior valor ao ser utilizado o recurso de imagem Negativo. A imagem comprimida (x0,5) foi, majoritariamente, a mais específica. As acurácias médias do sistema digital Digora resultaram em valores aproximados. A estatística kappa, no diagnóstico de todas as lesões, fez distinção aos recursos x0,5, x1 e Negativo; no diagnóstico de lesões dentinárias, todas as modalidades de imagem expressaram concordância boa. O método digital foi mais sensível que os filmes, porém estes, no diagnóstico de lesões dentinárias, foram mais específicos. A acurácia média do sistema digital suplantou a dos filmes, em todos os kV, nos dois cut-off estudados, sendo as diferenças numéricas menores no diagnóstico de lesões dentinárias. Os valores de kappa obtidos pelos filmes assemelharam-se aos de algumas modalidades de imagem do sistema digital Digora, no diagnóstico de todas as lesões; excetuando-se o Ektaspeed, em 50 kV, os filmes não alcançaram os valores de kappa revelados pelo sistema digital, no diagnóstico de lesões dentinárias. Cohen’s kappa revelou boa concordância intra-examinador (0,758). O sistema digital estudado revelou-se comparável ao método radiográfico convencional, no diagnóstico de lesões de cárie em superfícies proximais de molares decíduos. / This study evaluated the diagnostic performance of Agfa M2 and Ektaspeed plus dental films and Digora digital system. The material comprised 37 extracted primary molars and it was exposed at 50, 70 and 90 kV. The images of 41 proximal surfaces were examined under standardised conditions. Five imaging modes (x0,5, x1, x2, Negative and 3D) included in digital system software, were used. The teeth were sectioned and observed under a stereomicroscope (x40). The data were analysed by means of sensitivity, specificity, accuracy and unweighted kappa. Agfa M2 exposed at 90 kV and Ektaspeed plus at 50 kV obtained higher sensitivity, accuracy and kappa values. Films specificity were comparable, in both cut-off. Digora sensitivity demonstrated high values using the Negative mode. The x0,5, in the majority, revealed the highest specificity. Average accuracy of digital system were very similar. The x0,5, x1 and Negative mode showed good agreement with the gold standard, for all lesions diagnostic. In the dentine lesions cut-off, all the modes established good agreement. The digital system sensitivity values were higher than the conventional films, but films revealed higher values for specificity, specially for dentine lesions detection. Digora accuracy average values were higher than the films, in any kilovoltage and both cut-off, but the differences were smaller in dentine caries diagnostic. The films unweighted kappa values were the same of some image mode, in all caries diagnostic; except for Ektaspeed plus, at 50 kV, films didn’t get Digora kappa values in dentine diagnostic. Cohen’s kappa showed good intraexaminer reliability (0,758). Digital system appeared comparable with the conventional radiographic method in proximal primary molars caries diagnostic.
6

Avaliação dos recursos de mensuração em diferentes sistemas de radiografia digital / Evaluation of the mensurement resources in different systems of digital x-ray

Hernandez, Angelica Maria 09 March 2009 (has links)
Os avanços tecnológicos na área de radiologia digital proporcionam a cada dia novas informações e aplicações de seus sistemas, tornando-se assim ferramenta indispensável para a comunicação e administração de informações entre profissionais e pacientes. A proposta neste estudo foi comparar o fator de correção da ferramenta de medida de três diferentes sistemas de radiografia dentária digital, em maxila de crânios secos, na região de pré-molares, onde existe a influência natural de ângulos verticais, para avaliar o grau de confiabilidade da ferramenta de mensuração, com os padrões de calibração, quando estas medidas forem realizadas na maxila. Para este estudo foram selecionados 10 pré-molares superiores, os quais foram extraídos de seus alvéolos para obtenção do Padrão Ouro (PO) com auxílio de um paquímetro digital. Padrões metálicos foram utilizados para a realização das medidas calibradas, de 5mm e de 10mm, estes localizaram-se sob a superfície dos elementos dentários selecionados (SD) e em outra etapa da pesquisa sob o acetato sem a emulsão de prata de uma película radiográfica (PR). Três sistemas de radiografia digital realizaram a captura da imagem, em seus respectivos softwares realizou-se as medidas: a) sem calibração, b) com padrão de calibração de 5mm e c) com padrão de calibração de 10mm. Quatro observadores previamente instruídos realizaram as medidas. Os resultados foram submetidos a analise estatística de ANOVA seguida pelo método de Tukey a 5%, se obteve diferenças estatísticas, as quais representaram. O tamanho e a localização do padrão metálico interferiram nos resultados; não houve diferença entre as medidas inter-observadores; o software DBSWIN (VistaScan) e VixWin PRO (Visualix) foram os que apresentaram maior diferença entre as medidas. / The technological progresses in digital radiology provide every day new information and applications of this systems, become an indispensable tool for the communication and administration of information among professionals and patient. The aim of this study was compare the correlation factor of the measure tool on three different systems of digital dental x-ray, in maxilla of dry craniums, in the area of pre molars, where the natural influence of vertical angles exists, to evaluate the degree of reliability of the measure tool, with the patterns of arranged calibration in different local, when these measured they be accomplished in the maxilla. For this study 10 superior pre molars was selected, which were extracted of its alveoli for obtaining the Gold Standard (GS) with aid of a digital pachymeter. Metallic patterns were used for the accomplishment of the gauged measures, of 5mm and of 10mm, these were located under the surface of the elements dental selects (SD) and in other stage of the research under the acetate without the emulsion of silver of a film (PR). Three systems of digital x-ray accomplished the capture of the image in its respective softwares, they took place the measures: a) without calibration, b) with pattern of calibration of 5mm and c) with pattern of calibration of 10mm. 4 observers previously well educated accomplished the measures. The results were submitted an statistics analyzes ANOVA proceeded by the method of Tukey at 5%, it was obtained statistical differences. The length and the location of the standard metallic step in on the results; there was no difference among the observers measures; the software DBSWIN (VistaScan) and VixWin PRO (Visualix) have been presented more difference among the measures.
7

Avalia??o do efeito da formalina na descalcifica??o de esp?cimes anat?micos, por meio da densidade radiogr?fica e concentra??o de c?lcio

Fonseca, Alisson Andr? Robe 20 June 2007 (has links)
Made available in DSpace on 2015-04-14T13:29:11Z (GMT). No. of bitstreams: 1 397720.pdf: 4377048 bytes, checksum: c1288fe9b91b7ca21ccf4b256a0d7226 (MD5) Previous issue date: 2007-06-20 / O presente estudo teve por objetivo verificar se o processo de conserva??o de esp?cimes anat?micos em solu??o aquosa de formalina a 10% altera a densidade radiogr?fica dos tecidos, bem como se h? modifica??o da dosagem de c?lcio durante a fixa??o. Para tanto, 20 hemicabe?as, 20 membros p?lvicos e 20 conjuntos r?dio/ulna de coelhos foram distribu?dos cada um em um recipiente contendo um dos seguintes fixadores: solu??o aquosa de formalina a 10% e solu??o aquosa de formalina a 10% com tamp?o-fosfato (FTFA). As pe?as foram radiografadas em cinco tempos diferentes: antes de serem acondicionadas nas solu??es fixadoras (tempo zero) e um, 15, 30 e 90 dias ap?s. As radiografias foram digitalizadas e analisadas por meio do programa ImageTool?, em regi?es pr?-estabelecidas. Amostras das subst?ncias fixadoras foram submetidas a espectrofotometria para a verifica??o e dosagem da concentra??o de c?lcio, antes da fixa??o e 90 dias ap?s. N?o houve diferen?a significativa da densidade radiogr?fica entre os esp?cimes acondicionados em solu??o de formalina a 10% e formalina a 10% com tamp?ofosfato. A densidade radiogr?fica do tecido ?sseo diminuiu significativamente com o passar do tempo em ambas as solu??es fixadoras. Isto nos permite concluir que ocorre um processo progressivo de desmineraliza??o. Em rela??o ao tecido mole n?o foi evidenciado efeito algum sobre a densidade radiogr?fica nos diferentes tempos de an?lise. Aos noventa dias verificou-se a presen?a de c?lcio em ambas solu??es fixadoras, sendo que a maior concentra??o ocorreu no grupo da Formalina ? 10%
8

Kerma no ar com base no índice de exposição para radiografia digital / Air kerma based on the exposure index for digital radiography

Leite, Marina Silveira 26 November 2012 (has links)
Os receptores de imagem radiográfica digitais estão gradualmente substituindo os sistemas tela-filme em radiodiagnóstico. Atualmente a radiografia computadori- zada (CR - Computed Radiography) é a modalidade digital mais comum em muitos serviços de radiodiagnostico. E baseada na utilização de fósforos foto estimuláveis, que também são conhecidos como fósforo de armazenamento. Quando sistemas tela-filme são utilizados como receptores de imagem, uma dose de radiação inadvertidamente alta no paciente irá resultar em um filme escuro, que fornece feedback imediato para o técnico em radiologia quanto aos fatores de técnica utilizados e a dose relativa. No entanto, quando receptores de imagem digitais são usados, uma dose alta no paciente pode produzir imagens excelentes o que resulta em uma tendência de se utilizar doses mais elevadas do que o necessário. A adequada justificação e otimização dos procedimentos exige o conhecimento dos valores típicos de dose em pacientes em um determinado serviço de radiodiagnóstico. O termo índice de exposição refere-se à dose absorvida na placa fósforo. Após a leitura da imagem com um sistema de laser o histograma dos sinais é computado e o índice de exposição é determinado com base nos valores dos pixels (picture elements) usando uma relação logarítmica. Os fabricantes dos sistemas de CR oferecem os índices de exposição como um salvaguarda contra doses altas, mas a base para os valores recomendados não é clara. Além disso, os índices de exposição não estão diretamente relacionados com a dose no paciente. O objetivo deste trabalho foi estabelecer um método indireto para calcular os valores de dose de entrada em pacientes submetidos a exames diagnósticos em sistemas de raios X com CR com base no índice de exposição. / The receptors of digital radiography image are gradually substituting the screen-film systems in radiodiagnostic. Currently, computed radiography is the most common method in many radiography services. It is based in the application of photostimulable phosphorus, that are also known as phosphorus storage. When screen-film systems are utilized as image receptors, an inadvertently high dose of radiation in the patient will result in a dark film screen, that inputs immediate feedback to the radiology technician as to the technical factors utilized and the relative dose. However, when digital image receptors are used, a high dose in the patient can produce excelent images which re-sult in a tendency of using higher doses than necessary. The adequate extenuation and optimization of the procedures demand the knowledge of the characteristic dose values in patients in a determined radiodiagnostic service. The term exposure index refers to the absorbed dose in the phosphorus plate. Following the image reading with a laser system the histogram of signs is computed and the exposure index is determi-ned in the basis of picture elements using a logarithmic relationship. The manufacturer of the systems of pixels offer the exposure indexes as a safeguard against high doses, but the basis for the recommended values are not clear. Moreover, the exposure indexes are not directly related to the dose in patients. The aim of this work was to establish an indirect method to estimate the values of entrance doses in patients who have undergone diagnostic exams in X ray systems with computed radiography based on exposure indexes. The values of entrance doses obtained were compared with the values also obtained indirectly based in the measurements of the X ray tubes output.
9

Avaliação de reabsorções radiculares externas por meio de reconstrução digital de imagens e subtração radiográfica digital

Ono, Evelise [UNESP] 22 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-04-22Bitstream added on 2014-06-13T20:46:09Z : No. of bitstreams: 1 ono_e_dr_sjc_prot.pdf: 724673 bytes, checksum: 4e42b923c66c9d34cc50e91707bc9ad8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Diante dos prejuízos que a reabsorção severa da raiz pode acarretar, e considerando a técnica de subtração radiográfica digital (SDR) importante recurso para detecção precoce de alterações minerais, propõe-se neste estudo avaliar a eficiência de um programa de computador, que execute o registro das imagens e SRD, no diagnóstico da reabsorção radicular externa simulada, comparado à radiografia digital, além da concordância intra e interexaminadores nos 2 métodos de diagnóstico. Os 49 dentes de mandíbulas humanas maceradas com reabsorções de diferentes dimensões, simuladas na região apical e lingual, foram radiografados com variação de ângulos de projeção. A radiografias foram registradas a posteriori pelo programa Regeemy® e subtraídas pelo programa Image Tool®. A quantidade de ruído estrutural nas imagens subtraídas foi obtida pela mensuração da média e desvio-padrão dos níveis de cinza. Para avaliação do desempenho dos métodos de diagnóstico, pares de radiografias periapicais e imagens subtraídas foram apresentadas a 3 radiologistas. De acordo com os resultados, o ruído das imagens subtraídas de radiografias após variações de 10º e 20º do ângulo vertical e 10º horizontal e corrigidas a posteriori, foi significantemente maior que das imagens subtraídas de radiografias padrão, independente da região radiografada. Não houve diferença estatisticamente significativa entre os métodos na detecção de reabsorções apicais, independentemente do tamanho da lesão, assim como não houve diferença entre os métodos na detecção de reabsorções linguais de 1,2 mm ou mais. A SRD foi significantemente superior à radiografia digital para detecção de lesões linguais de cerca de 1 mm. Cavidades na superfície lingual de cerca de 0,5 mm não foram detectadas com precisão por nenhum dos métodos... / Because of the harm that severe root resorption may cause and considering the digital subtraction technique (DSR) as an important tool for early detection of mineral alterations, the aims on the present study are to assess the efficiency of a computer software for image registration and DSR on the diagnosis of simulated root resorption, to compare their results with those obtained with digital radiographs, and to assess the intra- and inter-examiner agreement using the two methods of diagnosis. Forty nine teeth with simulated lingual and apical root resorptions of varied extension were x-rayed with different projection angles. The radiographs were registered a posteriori with Regeemy® software and subtracted with Image Tool® software. The amount of structural noise of the subtracted images was evaluated by measuring the mean and standard-deviation of their gray levels. The performance of each method of diagnosis was assessed by submitting pairs of periapical radiographs and the subtracted images to the evaluation of three oral radiologists. According to the results, the structural noise of subtracted images from radiographs with variations of 10º and 20º of vertical angle and 10º of horizontal angle was significantly higher than the obtained from the radiographs without angular variation, independently from the anatomic region of the image. There was no statistically significant difference between the methods on the detection of apical root resorptions independently from the size of the lesion as well as no statistically significant difference was found between the methods on the detection of lingual resorptions of 1.2mm or more. DSR was significantly superior to the digital radiographs on the detection of lingual lesions of around 1mm. Lingual lesions of around 0.5mm were not precisely detected by any of the methods. The inter- and intra-examiner agreements were substantial... (Complete abstract, click electronic access below)
10

Avaliação da arquitetura óssea trabecular por meio de processamento de imagem digital em radiografias panorâmicas

Klein, Caroline Gugisch 10 2010 (has links)
Este trabalho teve como objetivo modificar um algoritmo de esqueletização e criar outro para quantificar imagens radiográficas. Foi proposto um tratamento digital em radiografias panorâmicas de 50 voluntárias diagnosticadas como osteoporóticas e não osteoporóticas em um estudo anterior. Para verificar a validade deste recurso digital, foi elaborado um questionário que juntamente com as radiografias foi distribuído entre quinze examinadores radiologistas. Estes analisaram de forma subjetiva 99 imagens, respondendo quais os critérios adotados para a avaliação da arquitetura óssea trabecular. Os dados obtidos no questionário aplicado e no tratamento digital das imagens foram submetidos à análise descritiva para verificar o nível de concordância nas hipóteses de diagnóstico e definir um padrão ouro. Foi construída uma curva ROC, para verificar o ponto de corte e estabelecer qual filtro de Gauss era o melhor, com raio variável de 30, 35, 40, 45 ou 50. O filtro escolhido foi o de raio 30, pois apresentou melhor especificidade (94,3%), mesmo tendo uma baixa sensibilidade (50%). Os níveis de concordância entre os examinadores ficaram abaixo de 80%. Contudo foi registrada alta significância entre os dados percentuais de pontos pretos e de pontos terminais (p<0.001). O processamento de imagens através da esqueletização em radiografias panorâmicas pode tornar-se um valioso recurso para os cirurgiões-dentistas. / The purpose of the present work was to modify a skeletonization algorithm and to create an algorithm to quantify radiographic images. A panoramic radiographic digital treatment of 50 volunteers diagnosed as otheoporotics and non-ostheoporotics in a previous work was done. In order to verify the validity of the digital resource, a questionnaire was elaborated that along with the radiographies was distributed among 15 radiologists. The examiners analyzed in a subjective way 99 images, responding which criteria were adopted for the evaluation of the trabecular bone architecture. The data obtained in the applied questionnaire and in the digital image treatment were submitted to a descriptive analysis in order to verify the agreement in the diagnostic hypothesis and to define a golden standard. A ROC curve was built to check the cut point and to establish which Gauss filter was the best, with a variable ratio of 30, 35, 40, 45, or 50. The ratio 30 filter was chosen since it presented the best specificity (94.3%), even having a low sensibility (50%). The agreement levels among the examiners were below 80%. However a high significance among the percentage of black points was registered (p<0.001). The method of image processing trough the skeletonization in panoramic radiographies can become a valuable support for the dentist-surgeons.

Page generated in 0.0603 seconds