Avaliação das propriedades diagnósticas de dispositivo de baixo custo de digitalização de radiografias analógicas

Godoy, Giltom Fontoura de January 2011 (has links)
Made available in DSpace on 2013-08-07T19:06:55Z (GMT). No. of bitstreams: 1 000434560-Texto+Completo-0.pdf: 312802 bytes, checksum: cc55cda57da799d28b7e5ed47e64e6c6 (MD5) Previous issue date: 2011 / AIM: To evaluate diagnostic properties of low cost scanning chamber (auxiliary chamber) of radiologic images, comparing the results of digital images analysis with conventional analogic images (gold standard).METHODS: Ninety antero posterior chest radiographies from pediatric patients were collected from monthly requested exams of the pediatric emergency section of São Lucas and Conceição Hospital (Porto Alegre – RS – Brazil), and Hospital Universitario (Santa Maria-RS-Brazil). The images were digitized with the use of auxiliary chamber and a non-professional low cost digital camera. Two independent pediatric radiologists evaluated original analogical radiographies (reference standard) and digitized images obtained by the auxiliary chamber, analyzing the three most common parameters of acute respiratory pathologies: pneumonic consolidation, interstitial infiltrate and normal lung transparency. From the ninety radiographies selected, thirty were normal, thirty had pneumonic consolidation and thirty had interstitial infiltrate. RESULTS: The auxiliary chamber images showed good diagnostic power when compared to analogical radiographic films, showing excellent concordance in intra-observers analysis (K >0. 80) and good concordance between-observers (K = 0. 60 – 0. 80).CONCLUSION: The auxiliary chamber has good concordance with analogical radiographic films. It is inexpensive and accessible equipment which may allow remote report and expert radiologists’ second opinion, integrating the concept of teleradiology. / OBJETIVO : Avaliar as propriedades diagnósticas da caixa digitalizadora de baixo custo de imagens radiológicas (“câmara auxiliar”), mediante a comparação dos resultados das análises das imagens digitais com os das imagens analógicas originais (padrão de referência).MATERIAIS E MÉTODO : Noventa radiografias de tórax, obtidas mediante projeção ântero-posterior (AP) de pacientes pediátricos, coletadas dentre os exames solicitados mensalmente nos hospitais São Lucas, Grupo Hospitalar Conceição, Porto Alegre e Hospital Universitário de Santa Maria, RS, Brasil, foram digitalizadas com o auxílio da caixa digitalizadora (“câmara auxiliar”), usando-se câmera fotográfica digital de baixo custo, de uso amador. Dois radiologistas pediátricos, independentes, avaliaram as radiografias analógicas originais (padrão de referência) e as imagens digitais obtidas por meio da caixa digitalizadora, concentrando-se nos três parâmetros mais frequentemente encontrados em patologias respiratórias agudas, a saber: consolidação pneumônica, infiltrado intersticial e transparência pulmonar normal. Das noventa radiografias selecionadas, trinta não possuíam alterações, trinta apresentavam condensações pneumônicas e trinta apresentavam infiltrados intersticiais. RESULTADOS : As imagens produzidas pela caixa digitalizadora permitem a realização de diagnósticos comparáveis aos obtidos mediante a análise das radiografias analógicas originais, observando-se boa concordância nas análises feitas intra-observador (K > 0, 80) e, igualmente, boa entre - observadores (K = 0,60-0,80).CONCLUSÃO : A caixa digitalizadora, ao auxiliar a produzir imagens digitais que apresentam boa concordância diagnóstica com o filme radiológico, representa uma alternativa acessível e de baixo custo para uso em transmissão de imagens radiológicas, permitindo obter-se laudo remoto, ou segunda opinião de radiologistas especializados, integrando o conceito de um sistema de telerradiologia.
12

Avaliação da arquitetura óssea trabecular por meio de processamento de imagem digital em radiografias panorâmicas

Klein, Caroline Gugisch 10 2010 (has links)
Este trabalho teve como objetivo modificar um algoritmo de esqueletização e criar outro para quantificar imagens radiográficas. Foi proposto um tratamento digital em radiografias panorâmicas de 50 voluntárias diagnosticadas como osteoporóticas e não osteoporóticas em um estudo anterior. Para verificar a validade deste recurso digital, foi elaborado um questionário que juntamente com as radiografias foi distribuído entre quinze examinadores radiologistas. Estes analisaram de forma subjetiva 99 imagens, respondendo quais os critérios adotados para a avaliação da arquitetura óssea trabecular. Os dados obtidos no questionário aplicado e no tratamento digital das imagens foram submetidos à análise descritiva para verificar o nível de concordância nas hipóteses de diagnóstico e definir um padrão ouro. Foi construída uma curva ROC, para verificar o ponto de corte e estabelecer qual filtro de Gauss era o melhor, com raio variável de 30, 35, 40, 45 ou 50. O filtro escolhido foi o de raio 30, pois apresentou melhor especificidade (94,3%), mesmo tendo uma baixa sensibilidade (50%). Os níveis de concordância entre os examinadores ficaram abaixo de 80%. Contudo foi registrada alta significância entre os dados percentuais de pontos pretos e de pontos terminais (p<0.001). O processamento de imagens através da esqueletização em radiografias panorâmicas pode tornar-se um valioso recurso para os cirurgiões-dentistas. / The purpose of the present work was to modify a skeletonization algorithm and to create an algorithm to quantify radiographic images. A panoramic radiographic digital treatment of 50 volunteers diagnosed as otheoporotics and non-ostheoporotics in a previous work was done. In order to verify the validity of the digital resource, a questionnaire was elaborated that along with the radiographies was distributed among 15 radiologists. The examiners analyzed in a subjective way 99 images, responding which criteria were adopted for the evaluation of the trabecular bone architecture. The data obtained in the applied questionnaire and in the digital image treatment were submitted to a descriptive analysis in order to verify the agreement in the diagnostic hypothesis and to define a golden standard. A ROC curve was built to check the cut point and to establish which Gauss filter was the best, with a variable ratio of 30, 35, 40, 45, or 50. The ratio 30 filter was chosen since it presented the best specificity (94.3%), even having a low sensibility (50%). The agreement levels among the examiners were below 80%. However a high significance among the percentage of black points was registered (p<0.001). The method of image processing trough the skeletonization in panoramic radiographies can become a valuable support for the dentist-surgeons.
13

Detecção de lesões periapicais incipientes por subtração radiográfica com imagens panorâmicas digitais e digitalizadas

Miguens Júnior, Sergio Augusto Quevedo January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:08Z (GMT). No. of bitstreams: 2 000403444-0.pdf: 99251 bytes, checksum: c511a21b9654eae769d50167ba714be8 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This thesis comprises two articles. In the first article, we assessed in vitro the ability of digital subtraction radiography (DSR) in the detection of incipient periapical lesions using panoramic digital and digitized radiographs. Periapical defects were created in dried human mandibles through application of 70% perchloric acid at times 2, 4, and 6 hours. Conventional and digital radiographs were obtained twice at time zero, with the aim of evaluating reproducibility of this technique, and sequentially before each application of the acid solution. Conventional radiographs were digitized using a scanner with the same attributes than direct digital radiographs: 150-dpi resolution, 8-bit mode and stored as non-compressed TIFF format. The software Adobe Photoshop® was used for DSR of the images in the following sequence: T0x0 repeated; T0xT2; T0xT4; and T0xT6. The variable under analysis was the difference between pixel intensity in control and test areas. Using ANOVA to compare the size of the areas marked to obtain pixel intensity values in different experimental times, no differences were observed between times both for the test (F= 0. 44; P = 0. 726) and for the control area (F= 1. 20; P = 0. 310). Comparing experimental times, there were significant differences, time 6 having the highest mean of mineral loss. Times 2 and 4 had no differences, but were significantly higher than time 0, both for digitized (F= 45. 01; P< 0. 001) and for digital images (F= 30. 80; P < 0. 001). We concluded that DSR of panoramic radiographic images, whether digital or digitized, allows for detection of incipient periapical defects. In the second article, we compared in vitro specificity, sensitivity, and diagnostic accuracy of digital subtraction radiography (DSR) in digital and digitized panoramic images in the detection of incipient periapical lesions. The images were assessed by an experienced and blinded observer, who attributed scores 0 (absence of image representing mineral loss) or 1 (presence of dark image representing mineral loss) to each image. Results were evaluated using analysis of variance (ANOVA), complemented by Dunnett’s T3 multiple comparison test; the level of significance was set at 5%. The observer showed Kappa values = 0. 640 for DSR of digital images; and 0. 574 for DSR of digitized images. There was 100% intrarater agreement at time 0. Sensitivity of both modalities was statistically different in relation to experimental times. Time 6 had the highest values (digital: 1. 000; digitized: 0. 961), while time 2 showed the lowest values (0. 688 and 0. 714). Irrespective of the imaging method, the proportion of correct responses significantly increased regarding experimental times. Specificity was high for DSR of both digitized (0. 896) and digital (0,844) images. Accuracy in time 6 was higher than that of other times, both for the digitized (0. 929) and digital (0. 922) modalities. DSR of panoramic images, both digitized and digital, allows for detection of incipient periapical lesions, with satisfactory sensitivity and specificity values. / Esta tese é apresentada sob a forma de dois artigos. O artigo I avaliou, in vitro, a capacidade da subtração radiográfica digital (SRD) na detecção de lesões periapicais incipientes em radiografias panorâmicas digitais e digitalizadas. Foram criados defeitos periapicais em mandíbulas humanas secas pela aplicação de ácido perclórico a 70%, nos tempos 2, 4 e 6 horas. As radiografias convencionais e digitais foram obtidas duas vezes no tempo zero, com intenção de avaliar a reprodutibilidade da técnica, e, seqüencialmente, antes de cada aplicação da solução ácida. As radiografias convencionais foram digitalizadas em scanner com os mesmos atributos que as digitais diretas: resolução de 150 dpi, 8 bits e armazenadas em formato TIFF sem compressão. O programa Adobe Photoshop® foi utilizado para a SRD das imagens, na seguinte seqüência: T0x0 repetido; T0xT2; T0xT4 e T0xT6. A variável analisada foi a diferença entre a intensidade de pixel das áreas controle e teste. Comparando o tamanho da área delimitada para a obtenção dos valores de intensidade de pixels nos diferentes tempos experimentais observou-se, por meio da ANOVA, não haver diferença entre os tempos tanto para a área-teste (F= 0,44; p=0,726) quanto para a área-controle (F=1,20; p=0,310). Comparando os tempos experimentais observou-se que existiu diferença significativa entre eles, sendo o tempo 6 o que apresentou maior média de expressão de perda mineral. Os tempos 2 e 4 não diferiram entre si, porém foram significativamente maiores que o tempo 0, tanto nas imagens digitalizadas (F= 45,01; p<0,001) quanto nas digitais (F= 30,80; p<0,001). Concluiu-se que a SRD de imagens radiográficas panorâmicas, tanto digitais quanto digitalizadas, permite a detecção de defeitos periapicais incipientes.O artigo II comparou, in vitro, a especificidade, sensibilidade e acurácia diagnóstica das radiografias panorâmicas digitais e digitalizadas na detecção por SRD de lesões periapicais incipientes. As imagens foram avaliadas por um observador experiente, cego quanto ao tipo de imagem e grupo que lhes atribuiu escore 0 (ausência de imagem representativa de perda mineral) ou 1 (presença de imagem escura de perda mineral). Os resultados foram avaliados por meio da ANOVA, complementada pelo Teste de Comparações Múltiplas de Dunnett T3, com α=5%. O observador apresentou coeficiente de Kappa = 0,640 para a SRD em imagens digitais e 0,574 para as digitalizadas. No tempo 0 houve 100% de concordância intra-examinador. A sensibilidade de ambas as modalidades foi estatisticamente diferente em relação aos tempos experimentais. O tempo 6 apresentou o maior valor (digitais: 1,000; digitalizadas: 0,961), enquanto o tempo 2 apresentou os menores valores (0,688 e 0,714). Independente do método de imagem, a proporção de acertos aumentou significativamente em relação aos tempos experimentais. A especificidade foi alta tanto para a SRD em imagens digitalizadas (0,896) quanto para as digitais (0,844). A acurácia no tempo 6, tanto na modalidade digitalizada (0,929) como na digital (0,922), foi superior aos demais tempos. A SRD em radiografias panorâmicas, tanto digitalizadas como digitais, permite detectar lesões periapicais incipientes, com valores de sensibilidade e especificidade satisfatórios.
14

Avaliação dos recursos de mensuração em diferentes sistemas de radiografia digital / Evaluation of the mensurement resources in different systems of digital x-ray

Angelica Maria Hernandez 09 March 2009 (has links)
Os avanços tecnológicos na área de radiologia digital proporcionam a cada dia novas informações e aplicações de seus sistemas, tornando-se assim ferramenta indispensável para a comunicação e administração de informações entre profissionais e pacientes. A proposta neste estudo foi comparar o fator de correção da ferramenta de medida de três diferentes sistemas de radiografia dentária digital, em maxila de crânios secos, na região de pré-molares, onde existe a influência natural de ângulos verticais, para avaliar o grau de confiabilidade da ferramenta de mensuração, com os padrões de calibração, quando estas medidas forem realizadas na maxila. Para este estudo foram selecionados 10 pré-molares superiores, os quais foram extraídos de seus alvéolos para obtenção do Padrão Ouro (PO) com auxílio de um paquímetro digital. Padrões metálicos foram utilizados para a realização das medidas calibradas, de 5mm e de 10mm, estes localizaram-se sob a superfície dos elementos dentários selecionados (SD) e em outra etapa da pesquisa sob o acetato sem a emulsão de prata de uma película radiográfica (PR). Três sistemas de radiografia digital realizaram a captura da imagem, em seus respectivos softwares realizou-se as medidas: a) sem calibração, b) com padrão de calibração de 5mm e c) com padrão de calibração de 10mm. Quatro observadores previamente instruídos realizaram as medidas. Os resultados foram submetidos a analise estatística de ANOVA seguida pelo método de Tukey a 5%, se obteve diferenças estatísticas, as quais representaram. O tamanho e a localização do padrão metálico interferiram nos resultados; não houve diferença entre as medidas inter-observadores; o software DBSWIN (VistaScan) e VixWin PRO (Visualix) foram os que apresentaram maior diferença entre as medidas. / The technological progresses in digital radiology provide every day new information and applications of this systems, become an indispensable tool for the communication and administration of information among professionals and patient. The aim of this study was compare the correlation factor of the measure tool on three different systems of digital dental x-ray, in maxilla of dry craniums, in the area of pre molars, where the natural influence of vertical angles exists, to evaluate the degree of reliability of the measure tool, with the patterns of arranged calibration in different local, when these measured they be accomplished in the maxilla. For this study 10 superior pre molars was selected, which were extracted of its alveoli for obtaining the Gold Standard (GS) with aid of a digital pachymeter. Metallic patterns were used for the accomplishment of the gauged measures, of 5mm and of 10mm, these were located under the surface of the elements dental selects (SD) and in other stage of the research under the acetate without the emulsion of silver of a film (PR). Three systems of digital x-ray accomplished the capture of the image in its respective softwares, they took place the measures: a) without calibration, b) with pattern of calibration of 5mm and c) with pattern of calibration of 10mm. 4 observers previously well educated accomplished the measures. The results were submitted an statistics analyzes ANOVA proceeded by the method of Tukey at 5%, it was obtained statistical differences. The length and the location of the standard metallic step in on the results; there was no difference among the observers measures; the software DBSWIN (VistaScan) and VixWin PRO (Visualix) have been presented more difference among the measures.
15

Kerma no ar com base no índice de exposição para radiografia digital / Air kerma based on the exposure index for digital radiography

Marina Silveira Leite 26 November 2012 (has links)
Os receptores de imagem radiográfica digitais estão gradualmente substituindo os sistemas tela-filme em radiodiagnóstico. Atualmente a radiografia computadori- zada (CR - Computed Radiography) é a modalidade digital mais comum em muitos serviços de radiodiagnostico. E baseada na utilização de fósforos foto estimuláveis, que também são conhecidos como fósforo de armazenamento. Quando sistemas tela-filme são utilizados como receptores de imagem, uma dose de radiação inadvertidamente alta no paciente irá resultar em um filme escuro, que fornece feedback imediato para o técnico em radiologia quanto aos fatores de técnica utilizados e a dose relativa. No entanto, quando receptores de imagem digitais são usados, uma dose alta no paciente pode produzir imagens excelentes o que resulta em uma tendência de se utilizar doses mais elevadas do que o necessário. A adequada justificação e otimização dos procedimentos exige o conhecimento dos valores típicos de dose em pacientes em um determinado serviço de radiodiagnóstico. O termo índice de exposição refere-se à dose absorvida na placa fósforo. Após a leitura da imagem com um sistema de laser o histograma dos sinais é computado e o índice de exposição é determinado com base nos valores dos pixels (picture elements) usando uma relação logarítmica. Os fabricantes dos sistemas de CR oferecem os índices de exposição como um salvaguarda contra doses altas, mas a base para os valores recomendados não é clara. Além disso, os índices de exposição não estão diretamente relacionados com a dose no paciente. O objetivo deste trabalho foi estabelecer um método indireto para calcular os valores de dose de entrada em pacientes submetidos a exames diagnósticos em sistemas de raios X com CR com base no índice de exposição. / The receptors of digital radiography image are gradually substituting the screen-film systems in radiodiagnostic. Currently, computed radiography is the most common method in many radiography services. It is based in the application of photostimulable phosphorus, that are also known as phosphorus storage. When screen-film systems are utilized as image receptors, an inadvertently high dose of radiation in the patient will result in a dark film screen, that inputs immediate feedback to the radiology technician as to the technical factors utilized and the relative dose. However, when digital image receptors are used, a high dose in the patient can produce excelent images which re-sult in a tendency of using higher doses than necessary. The adequate extenuation and optimization of the procedures demand the knowledge of the characteristic dose values in patients in a determined radiodiagnostic service. The term exposure index refers to the absorbed dose in the phosphorus plate. Following the image reading with a laser system the histogram of signs is computed and the exposure index is determi-ned in the basis of picture elements using a logarithmic relationship. The manufacturer of the systems of pixels offer the exposure indexes as a safeguard against high doses, but the basis for the recommended values are not clear. Moreover, the exposure indexes are not directly related to the dose in patients. The aim of this work was to establish an indirect method to estimate the values of entrance doses in patients who have undergone diagnostic exams in X ray systems with computed radiography based on exposure indexes. The values of entrance doses obtained were compared with the values also obtained indirectly based in the measurements of the X ray tubes output.
16

Avaliação radiográfica da movimentação do segundo molar inferior após a exodontia do terceiro molar

Bernini, Gabriel Fiorelli 25 March 2009 (has links)
Muitos pacientes submetidos à exodontia de terceiros molares relatam, no pósoperatório, que percebem alterações na oclusão. Por isso é interessante avaliar se realmente existe esta possível movimentação para distal dos segundos molares inferiores após a exodontia dos terceiros molares. Os objetivos deste trabalho foram analisar e verificar se existe variação da angulação do longo eixo do segundo molar em relação ao longo eixo do primeiro molar por meio de tomadas radiográficas periapicais digitais pelo sistema Digora®. A amostra constituiu-se de 20 pacientes entre 15 e 25 anos de idade que possuíam terceiros molares inferiores não irrompidos, bilateralmente, com indicação para extração e que se apresentavam de maneira simétrica com relação ao seu posicionamento. Os dentes foram extraídos, sendo um dos lados mantido apenas o coágulo (grupo controle) e o outro lado (grupo experimental) recebeu o enxerto do material proposto e membrana de cortical óssea bovina desmineralizada (Gen-derm). No Adobe Photoshop 7.0 foi possível realizar os traçados dos longos eixos dos primeiros e segundos molares inferiores e a intersecção entre eles. O programa ImageJ 1.41 foi responsável pela obtenção dos valores das angulações. Os exames foram realizados utilizando medidas em imagens obtidas no controle pós-operatório imediato, de 2, 6 e 24 meses nos dois grupos estudados. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos experimental e controle, e também não houve diferença ao longo do tempo, sugerindo que não existe movimentação para distal dos segundos molares inferiores após a extração dos terceiros molares e alterações na oclusão. Unitermos: Terceiro molar, Radiografia digital, Movimentação dentária. / Many patients submitted to the extraction of third molars, report, postoperatively, that they feel alterations in their occlusion. Thus, it is interesting to assess whether this possible movement to the distal of lower second molars, following the removal of third molars, really exists. This work aimed at analyzing and verifying, through digital periapical radiographies of the Digora® System, whether the angulation of the second molar´s long axis varies in relation to that of the first molar. The sample was comprised of 20 patients between 15 and 25 yrs, who presented non-erupted lower third molars, bilaterally, referred to extraction and in a symmetrical manner, in relation to their position. The teeth were extracted, being maintained, in one of the sides, only the clot (control group), while the other side (experimental group) received the graft of the proposed material and demineralized cortical bone bovine membrane (Gen-derm). In the Adobe Photoshop 7.0, it was possible to perform the outlining of the long axes of lower first and second molars and the intersection between them. The 1.41 ImageJ Program allowed the angulations values, and the exams were performed by utilizing measures in images obtained in the immediate postoperative control of 2, 6 and 24 months, in the groups studied. No statistically significant difference was seen between the experimental and control groups, as there was no difference as time passed, suggesting that there is no movement towards the distal of lower second molars, following the extraction of third molars and alterations in the occlusion.
17

"Validação das ferramentas de calibragem de medidas em três sistemas de radiografia digital" / Assessment of calibration tools of three digital radiography systems

Girondi, José Raul 30 March 2006 (has links)
O desenvolvimento tecnológico busca fatores que possibilitem uma menor exposição do paciente e profissional aos raios ionizantes, maior agilidade no atendimento ao paciente e maior auxilio no desenvolvimento do diagnóstico final. Assim a associação entre informática e radiologia básica, traduzidas como radiologia digital, fez-se conseguir os fatores buscados. Uma ferramenta dos sistema digitais é a calibração prévia às medidas. Com essas observações avaliamos tais ferramentas de três sistemas de radiografias digitais, objetivando validar e comprovar sua eficácia nas metodologias dos trabalhos presentes e futuros. Para tanto utilizamos 20 dentes humanos secos provindos do Banco de Dentes Permanentes da FOUSP, os quais foram radiografados com o auxílio de três sistemas de radiografia digital, direto e semidireto (Digora, RVG Trophy e Visualix). O padrão ouro das medidas dos dentes foi a verificação das dimensões dos dentes por meio de um paquímetro digital e posteriormente comparados os seus padrões de medidas com os softwares dos respectivos sistema. Os resultados foram analisados estatisticamente pelo ANOVA (métodos de Tukey e Dunnett), chegando às seguintes conclusões: existe diferença significante entre os aparelhos p<0,001; a média das medidas obtidas houve diferença significante (p<0,001) com o aparelho Digora foi menor que as médias obtidas com os aparelhos das marcas Visualix e RVG; considerando-se o padrão A e o padrão B de calibragem, não existe diferença estatística significante entre os avaliadores; considerando-se a calibragem sem padrão, um dos avaliadores obteve média mais elevada que os demais avaliadores no caso das medidas realizadas com o aparelho Digora, porém este fato não se repetiu quando da utilização dos outros aparelhos; comparando-se as medidas de referência (paquímetro) observa-se que mais uma vez o aparelho Digora (padrão A, padrão B e sem padrão) apresentou diferença significativa; os aparelhos das marcas Visualix e RVG não mostraram diferenças significativas quando comparados com o valor de referência. / Technological development aims at reducing exposure of both the professional and the patient to ionizing radiation, improving patient treatment and aiding final diagnosis. The combination of computer technology and radiology, i.e. digital radiography, has made this possible. One of the tools of digital radiography systems is calibration prior to measurement. The purpose of this study was to assess the calibration tools of three digital radiography systems to verify their efficacy. Twenty human teeth obtained from the Human Teeth Bank of the School of Dentistry, University of São Paulo, were used. The dry teeth were radiographed using three different direct digital radiography systems Digora, RVG Trophy and Visualix. The measurements of the teeth obtained with a digital caliper were considered the gold standard. These measurements were later compared with those obtained using the digital systems. The results were submitted to ANOVA (methods of Tukey and Dunnett), and the following conclusions were drawn: there was a significant difference between the systems used (p < 0.001); the averages of the measurements obtained with the three systems were significantly different (p<0,001). Visualix and RVG were more accurate than Digora considering A and B calibration standards, no significant difference was observed between the examiners; when there was no calibration standard and the Digora system was used, one examiner obtained more high averages measurements than the others; when there was no calibration standard and Visualix or RVG systems were used, no differences were observed between the examiners; the measurements obtained with Digora system (standards A, B or no standard) were statistically different from the gold standard the measurements obtained with Visualix and RVG systems presented no significant difference when compared with the gold standard.
18

Melhoramento da tensão disruptiva de cadeias de isoladores de vidro para linhas de transmissão

Roberta Pereira Leite, Luiza January 2006 (has links)
Made available in DSpace on 2014-06-12T17:40:15Z (GMT). No. of bitstreams: 2 arquivo7614_1.pdf: 2492587 bytes, checksum: 9fdb3dceda854ab374cc2e324e109e2a (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / As cadeias de isoladores de vidro são largamente utilizadas tanto para isolar os condutores de eletricidade da terra como suportá-los mecanicamente nas torres das linhas de transmissão. A quebra parcial ou total das partes vítreas dos isoladores de vidro, por exemplo, por vandalismo, reduz drasticamente a suportabilidade à tensão elétrica devido à diferença de potencial e é um problema mundial porque é responsável por um número significativo de desligamentos não programados pelas empresas do setor elétrico. Na presente dissertação, visou-se estudar a tensão de disrupção numa cadeia de isoladores de vidro com diferentes unidades com a parte vítrea quebrada simulando uma linha de transmissão de 230 kV. Visou-se também desenvolver técnicas para aumentar a suportabilidade à tensão de disrupção aumentando a rigidez dielétrica da atmosfera em torno da cadeia de isoladores, assim como dos isoladores com aplicação de materiais dielétricos. Os seguintes experimentos foram realizados visando atingir os objetivos: (i) caracterizar os isoladores por radiografia digital para conhecer detalhes de sua estrutura interna; (ii) estudar a influência da distribuição dos isoladores de vidro com as saias vítrea quebradas ao longo da cadeia com dezesseis unidades, (iii) estudar a influência de atmosferas de ar e de gás SF6 sob pressões de até 1,3 atm numa câmara de acrílico utilizando até três isoladores e à freqüência industrial (60 Hz), (iv) estudar a utilização da jaqueta polimérica para aumentar a tensão disruptiva de isoladores. Estudos das tensões disruptivas foram realizadas em cadeias com 12, 10 e 9 isoladores de vidro com parte vítrea quebrada e distribuídos ao longo da cadeia em cinco diferentes configurações. Para efeito de comparação, a temperatura, pressão e umidade relativa foram corrigidas de acordo com a norma NBR 6936. As medidas de tensão disruptiva foram realizadas à freqüência industrial e sob impulso de manobra nas polaridades positiva e negativa. Como resultado, nas cadeias de isoladores de vidro com 6 unidades inteiras e 10 quebradas, observou-se uma diferença significante nos valores das tensões disruptivas em função da mudança na distribuição dos isoladores inteiros e quebrados ao longo da cadeia. Um resultado interessante ocorreu quando utilizamos 6 isoladores inteiros uniformemente distribuídos ao longo da cadeia e intercalados com 10 isoladores quebrados, onde obteve-se a tensão disruptiva de 459 kV, maior que quando utilizamos 7 isoladores inteiros intercalados com 9 quebrados, onde obteve-se o valor de tensão disruptiva de 448 kV. Este resultado pode ser atribuído à distribuição não uniforme de campo elétrico ao longo da cadeia e aumento do caminho. Nos ensaios com a câmara de atmosfera controlada, não se observou influência significativa da atmosfera de ar e SF6 e da pressão no valor da tensão disruptiva nos isoladores de vidro com as saias quebradas, que foi em torno de 15 kV. Por outro lado, o valor da tensão disruptiva para isoladores inteiros sob atmosfera de SF6 e sob a pressão de 1.3 atm alcançou um valor de 120 kV, enquanto que o valor da tensão disruptiva na atmosfera de ar e pressão local foi de 80 kV. Estudo comparativo sobre a tensão disruptiva da cadeia de 16 isoladores de vidro com as partes de vidro totalmente quebradas mas com pinos revestidos com jaqueta de nylon mostrou que a tensão disruptiva foi de 375 kV, que é cerca de 3,5 vezes superior do que uma cadeia com 16 isoladores quebrados convencionais. Consequentemente, os resultados positivos obtidos no presente trabalho poderão, com estudos mais detalhados, assegurar no futuro: um maior segurança na atuação das equipes que trabalham na manutenção de linhas energizadas e minimizar a quantidade de desligamentos das linhas de transmissão
19

Detec??o de les?es periapicais incipientes por subtra??o radiogr?fica com imagens panor?micas digitais e digitalizadas

Miguens Junior, Sergio Augusto Quevedo 19 June 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:19Z (GMT). No. of bitstreams: 1 403444.pdf: 99251 bytes, checksum: c511a21b9654eae769d50167ba714be8 (MD5) Previous issue date: 2008-06-19 / Esta tese ? apresentada sob a forma de dois artigos. O artigo I avaliou, in vitro, a capacidade da subtra??o radiogr?fica digital (SRD) na detec??o de les?es periapicais incipientes em radiografias panor?micas digitais e digitalizadas. Foram criados defeitos periapicais em mand?bulas humanas secas pela aplica??o de ?cido percl?rico a 70%, nos tempos 2, 4 e 6 horas. As radiografias convencionais e digitais foram obtidas duas vezes no tempo zero, com inten??o de avaliar a reprodutibilidade da t?cnica, e, seq?encialmente, antes de cada aplica??o da solu??o ?cida. As radiografias convencionais foram digitalizadas em scanner com os mesmos atributos que as digitais diretas: resolu??o de 150 dpi, 8 bits e armazenadas em formato TIFF sem compress?o. O programa Adobe Photoshop? foi utilizado para a SRD das imagens, na seguinte seq??ncia: T0x0 repetido; T0xT2; T0xT4 e T0xT6. A vari?vel analisada foi a diferen?a entre a intensidade de pixel das ?reas controle e teste. Comparando o tamanho da ?rea delimitada para a obten??o dos valores de intensidade de pixels nos diferentes tempos experimentais observou-se, por meio da ANOVA, n?o haver diferen?a entre os tempos tanto para a ?rea-teste (F= 0,44; p=0,726) quanto para a ?rea-controle (F=1,20; p=0,310). Comparando os tempos experimentais observou-se que existiu diferen?a significativa entre eles, sendo o tempo 6 o que apresentou maior m?dia de express?o de perda mineral. Os tempos 2 e 4 n?o diferiram entre si, por?m foram significativamente maiores que o tempo 0, tanto nas imagens digitalizadas (F= 45,01; p<0,001) quanto nas digitais (F= 30,80; p<0,001). Concluiu-se que a SRD de imagens radiogr?ficas panor?micas, tanto digitais quanto digitalizadas, permite a detec??o de defeitos periapicais incipientes. O artigo II comparou, in vitro, a especificidade, sensibilidade e acur?cia diagn?stica das radiografias panor?micas digitais e digitalizadas na detec??o por SRD de les?es periapicais incipientes. As imagens foram avaliadas por um observador experiente, cego quanto ao tipo de imagem e grupo que lhes atribuiu escore 0 (aus?ncia de imagem representativa de perda mineral) ou 1 (presen?a de imagem escura de perda mineral). Os resultados foram avaliados por meio da ANOVA, complementada pelo Teste de Compara??es M?ltiplas de Dunnett T3, com &#945;=5%. O observador apresentou coeficiente de Kappa = 0,640 para a SRD em imagens digitais e 0,574 para as digitalizadas. No tempo 0 houve 100% de concord?ncia intra-examinador. A sensibilidade de ambas as modalidades foi estatisticamente diferente em rela??o aos tempos experimentais. O tempo 6 apresentou o maior valor (digitais: 1,000; digitalizadas: 0,961), enquanto o tempo 2 apresentou os menores valores (0,688 e 0,714). Independente do m?todo de imagem, a propor??o de acertos aumentou significativamente em rela??o aos tempos experimentais. A especificidade foi alta tanto para a SRD em imagens digitalizadas (0,896) quanto para as digitais (0,844). A acur?cia no tempo 6, tanto na modalidade digitalizada (0,929) como na digital (0,922), foi superior aos demais tempos. A SRD em radiografias panor?micas, tanto digitalizadas como digitais, permite detectar les?es periapicais incipientes, com valores de sensibilidade e especificidade satisfat?rios.O artigo II comparou, in vitro, a especificidade, sensibilidade e acur?cia diagn?stica das radiografias panor?micas digitais e digitalizadas na detec??o por SRD de les?es periapicais incipientes. As imagens foram avaliadas por um observador experiente, cego quanto ao tipo de imagem e grupo que lhes atribuiu escore 0 (aus?ncia de imagem representativa de perda mineral) ou 1 (presen?a de imagem escura de perda mineral). Os resultados foram avaliados por meio da ANOVA, complementada pelo Teste de Compara??es M?ltiplas de Dunnett T3, com &#945;=5%. O observador apresentou coeficiente de Kappa = 0,640 para a SRD em imagens digitais e 0,574 para as digitalizadas. No tempo 0 houve 100% de concord?ncia intra-examinador. A sensibilidade de ambas as modalidades foi estatisticamente diferente em rela??o aos tempos experimentais. O tempo 6 apresentou o maior valor (digitais: 1,000; digitalizadas: 0,961), enquanto o tempo 2 apresentou os menores valores (0,688 e 0,714). Independente do m?todo de imagem, a propor??o de acertos aumentou significativamente em rela??o aos tempos experimentais. A especificidade foi alta tanto para a SRD em imagens digitalizadas (0,896) quanto para as digitais (0,844). A acur?cia no tempo 6, tanto na modalidade digitalizada (0,929) como na digital (0,922), foi superior aos demais tempos. A SRD em radiografias panor?micas, tanto digitalizadas como digitais, permite detectar les?es periapicais incipientes, com valores de sensibilidade e especificidade satisfat?rios.
20

Avaliação radiográfica digital de enxerto de crista ilíaca em fenda alveolar: estudo longitudinal in vivo

Leite, Eugênio Arcadinos January 2006 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:02:51Z No. of bitstreams: 1 Dissertacao Eugenio Leite.pdf: 1280278 bytes, checksum: f23be710eb7acbb9dbe2cb1e282c5193 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:12:19Z (GMT) No. of bitstreams: 1 Dissertacao Eugenio Leite.pdf: 1280278 bytes, checksum: f23be710eb7acbb9dbe2cb1e282c5193 (MD5) / Made available in DSpace on 2013-05-08T12:12:19Z (GMT). No. of bitstreams: 1 Dissertacao Eugenio Leite.pdf: 1280278 bytes, checksum: f23be710eb7acbb9dbe2cb1e282c5193 (MD5) Previous issue date: 2006 / A fenda alveolar é um distúrbio congênito que afeta crianças em todas as partes do mundo, trazendo comprometimentos funcional, estético e social. Diversos estudos têm avaliado as diferentes técnicas cirúrgicas para a reabilitação destes pacientes, sendo que a maioria utiliza critérios clínicos ou a radiografia convencional para analisar seu resultado terapêutico. Este trabalho teve como objetivo avaliar longitudinalmente o enxerto de crista ilíaca no tratamento de fenda alveolar unilateral, empregando análises quantitativas do tecido ósseo em radiografias digitalizadas. A amostra foi constituída por dez (10) indivíduos (seis (6) do gênero masculino e quatro (4) do gênero feminino), com idade entre 5 e 15 anos, operados por um mesmo cirurgião, no Hospital Santo Antônio (HSA) – Obras Sociais Irmã Dulce (OSID) (SSA-BA), utilizando a crista ilíaca como área doadora dos enxertos. Foram obtidas radiografias periapicais pré e pós-operatórias imediatas e tardias, que foram digitalizadas e corrigidas no programa Photoshop®, e posteriormente analisadas no programa ImageTool®. Os resultados mostraram que a técnica utilizada preencheu adequadamente a área da fenda e que este preenchimento manteve-se estável no pós-operatório tardio. / Salvador