• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 29
  • 16
  • 3
  • Tagged with
  • 92
  • 92
  • 29
  • 21
  • 17
  • 14
  • 12
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Estudo da correlação entre adaptação marginal e tensões transmitidas aos implantes por estruturas metálicas fundidas em monobloco - análise fotoelástica. / A study of the correlation between marginal fit and tensions transmitted to implants by one-piece metal castings - a photoelastic analysis.

Torres, Érica Miranda de 19 December 2005 (has links)
Um dos maiores obstáculos para o sucesso das reabilitações com próteses sobre implantes consiste na obtenção de boa adaptação marginal dos componentes protéticos. Não está claro na literatura quais níveis de desajuste são considerados clinicamente aceitáveis, mas sabe-se que a ausência de perfeito ajuste e assentamento passivo pode provocar tensões inadequadas na interface de osseointegração, possibilitando problemas mecânicos e biológicos. A fotoelasticidade é uma técnica experimental para análise de tensões capaz de produzir resultados bastante confiáveis e fiéis aos parâmetros clínicos. Quando estruturas metálicas para próteses sobre múltiplos implantes são fundidas em monobloco, a obtenção de boa adaptação marginal parece ser ainda mais crítica. Contudo, não se verificam estudos que abordem a influência do tipo de metal ou liga empregado nessas fundições sobre os níveis de desadaptação protética. Assim, o presente estudo tem como objetivos verificar a adaptação marginal entre os pilares intermediários e estruturas fundidas em monobloco com diferentes materiais; avaliar, pelo método fotoelástico, as tensões impostas aos implantes quando a eles são fixadas as estruturas metálicas; e ainda pesquisar possíveis correlações entre os níveis de adaptação marginal e as tensões geradas na interface implante-material fotoelástico. Para tanto, utilizando cilindros calcináveis, foram enceradas 15 estruturas para próteses implanto-retidas sobre modelo simulando o posicionamento de cinco implantes na região intermentoniana. As estruturas foram divididas em grupos de cinco e fundidas em monobloco com titânio comercialmente puro grau I, liga de cobalto-cromo ou liga de níquel-cromo-titânio. A adaptação marginal foi avaliada, em microscópio ótico, quanto à passividade, por meio do teste de único parafuso, com aperto alternado nos implantes distais A e E, e quanto aos níveis de desajuste vertical, com todos os parafusos apertados com um torque de 10Ncm. As tensões geradas na área correspondente à região de crista óssea marginal em torno dos implantes foram avaliadas por meio de análise fotoelástica quantitativa empregando o método de compensação de Tardy. Após análise estatística dos resultados (p<0.05), verificou-se que, nos testes de passividade, o Ti cp apresentou resultados significantemente superiores de adaptação quando comparado as ligas de Co-Cr e Ni-Cr-Ti, as quais não apresentaram diferenças estatísticas entre si. O Ti cp foi semelhante à liga de Ni-Cr-Ti quanto aos níveis de desajuste vertical e tensões impostas aos implantes, com resultados superiores àqueles obtidos com a liga de Co-Cr. Foram aplicados testes de correlação entre as tensões fotoelásticas e os seguintes parâmetros: desajuste vertical, passividade média, adaptação marginal absoluta e percentual de redução de desajuste. Verificou-se correlação significante apenas entre os valores de adaptação marginal absoluta e tensões geradas pelas estruturas de Ni-Cr-Ti. Pode-se concluir que estruturas para próteses fixas sobre múltiplos implantes fundidas em monobloco podem produzir níveis biologicamente aceitáveis de desajuste, sendo os melhores resultados obtidos com o Ti cp, seguido das ligas de Ni-Cr-Ti e Co-Cr, respectivamente. Dentre os metais avaliados, a liga de Co-Cr transmitiu maiores níveis de tensões aos implantes. De um modo geral, não foram verificadas correlações entre valores de adaptação marginal e tensões impostas aos implantes. / Obtaining a good marginal fit of the prosthetic components is one of the main obstacles to the success of rehabilitation with implant-supported prostheses. It is not clear, in the literature, which misfit levels are considered clinically acceptable, but it is known that the absence of a perfect and passive fit may cause inadequate tensions on the osseointegration interface, which may bring about mechanical and biological problems. Photoelasticity is an experimental technique, used to analyze tensions, which is capable of producing results that are reliable to clinical parameters. When metal multiple-unit implant frames are cast in a single unit, it seems that obtaining a good marginal fit is even more critical. However, there are no studies in the literature about the influence that the type of metal or alloy used in these castings may have on the levels of prosthesis misfit. Thus, the present study has the aim to verify the marginal fit between the intermediate abutments and the one-piece structures cast with different materials; perform a photoelastic assessment of the tensions caused on implants when metal frames are fixed to them; and, research the possible correlations between the levels of marginal fit and the tensions generated on the interface implant-photoelastic material. To do this, 15 frames for implant-retained prostheses were waxed, using calcinable cylinders, simulating the positioning of five implants on the inter-mentalis region. The frames were divided into groups (n=5) and cast in a single piece with commercially pure titanium grade I, cobalt-chrome alloy, or nickel-chrome-titanium alloy. Marginal fit was assessed by optic microscopy, in terms of passivity, by a single screw test with alternate tightening on the distal implants A and E. As to the levels of vertical misfit, all screws were tightened to a torque of 10Ncm. Tensions generated in the area corresponding to the marginal bone crest region surrounding the implants were assessed by quantitative photoelastic analysis using the Tardy compensation method. After the statistical analysis of the results (p<0.05), it was verified that, in the passivity tests, the Ti cp showed significantly superior fitting results when compared to the Co-Cr and Ni-Cr-Ti alloys, which showed no statistically significant differences between them. In terms of the levels of vertical misfit and tensions over the implants, Ti cp was similar to the Ni-Cr-Ti alloy, showing superior results when compared to the Co-Cr alloy. Correlation tests were performed between the photoelastic tensions and the following parameters: vertical misfit, mean passivity, absolute marginal fit, and percentage of misfit reduction. A significant correlation was observed only between the values of absolute marginal fit and the tensions generated by the Ni-Cr-Ti frames. It is concluded that one-piece cast multiple-unit implant frames may produce biologically acceptable misfit levels, and the best results are obtained with Ti cp, followed by the Ni-Cr-Ti and Co-Cr alloys, respectively. Among the assessed metals, the Co-Cr alloy transmitted higher tension levels to the implants. In a general way, no correlations were observed between the values of marginal fit and tensions on implants.
72

Influência do material e técnica de obtenção da infraestrutura na distribuição de tensão de próteses parciais fixas com cantilever / Influence of material and infrastructure obtaining techniques on the stress distribution of cantilever fixed partial dentures

Tonin, Bruna Santos Honório 23 January 2017 (has links)
A passividade da prótese parcial fixa (PPF) sobre implante e a distribuição de tensões ao osso pela infraestrutura, contribuem não só com a osseointegração como também para a sua manutenção. A análise de tensões por fotoelasticidade permite visualizar as magnitudes de tensões e deformações em um modelo confeccionado em resina fotoelástica que possui padrão de concentração e distribuição de tensões semelhantes ao tecido ósseo. Assim, este estudo teve como objetivos comparar a distribuição de tensões de PPFs associadas à cantilever com diferentes materiais de infraestrutura (Co-Cr e Zircônia [Zr]) e métodos de obtenção (CAD/CAM e fundição convencional [monobloco, soldagem a laser e soldagem com TIG]), quando submetidos a diferentes carregamentos oclusais (puntiforme e oclusal distribuído). A partir de um modelo mestre, foram confeccionados 3 modelos fotoelásticos simulando extremidade livre mandibular,com o dente 44 em resina e 2 implantes substituindo os dentes 45 e 46. Os grupos deste estudo incluíram PPFs com infraestruturas obtidas por meio de fundição convencional em monobloco (G1), seccionadas e soldadas a laser (G2) e com TIG (G3) e obtidas por meio do sistema CAD/CAM em Co-Cr (G4) e Zr (G5). As PPFs foram parafusadas sobre os mini pilares e submetidas a carregamento oclusal puntiforme e distribuído (150 N) para avaliação qualitativa das franjas e quantitativa em seis diferentes pontos: apical (P1) e distal (P2) do dente 44, apical (P3) e distal (P4) do implante substituindo o dente 45, apical (P5) e distal (P6) do implante substituindo o dente 46. A análise fotoelástica mostrou maior concentração de tensões na PPF com infraestrutura em monobloco (G1) e menor concentração nas próteses obtidas pelo método CAD/CAM (G4 e G5). Quando submetidos ao carregamento oclusal distribuído, a PPF com infraestrutura em Zr (G5) apresentou um aumento considerável na concentração de tensões, seguida por monobloco (G1) e as que foram soldadas a laser (G2) e TIG (G3). No carregamento pontual sobre o cantilever, a infraestrutura em Co-Cr soldada a TIG (G3) mostrou a maior concentração de tensões. Dentro das limitações deste estudo, concluiu-se que PPFs com infraestruturas obtidas por meio do sistema CAD/CAM foram associadas com menor concentração de tensões e que a secção de infraestruturas metálicas para posterior soldagem pode também ser uma alternativa viável, de acordo com a distribuição de tensões peri-implantes. / The passivity of fixed partial denture (FPD) on implant and the stress distribution to the bone by the infrastructure, contribute not only to osseointegration but also to its maintenance. The stress analysis by photoelasticity allows visualizing the stresses and deformations magnitudes in a model fabricated in photoelastic resin that has a concentration pattern and stress distribution similar to the bone tissue. The aim of this study was to compare the stress distribution of cantilever FDPs with different infrastructure materials (Co-Cr and Zirconia [Zr]) and methods of manufacture (CAD/CAM and conventional casting [one piece, laser welding and welding with TIG]), when submitted to different occlusal loads (punctiform and distributed occlusal). From a master model, 3 photoelastic models were fabricated to simulate the mandibular free end, with the tooth 44 in resin and 2 implants replacing the teeth 45 and 46. The groups of this study included FPDs with infrastructures obtained by conventional casting in one piece (G1), sectioned and laser welded (G2) and TIG (G3) and obtained by the CAD/CAM system in Co-Cr (G4) and Zr (G5). The FDPs were screwed onto the abutments and subjected to punctate and distributed occlusal loading (150 N) for qualitative evaluation of the fringes and quantitative at six different points: apical (P1) and distal (P2) of the tooth 44, apical (P3) and distal (P4) of the implant replacing the tooth 45, apical (P5) and distal (P6) of the implant replacing the tooth 46. The photoelastic analysis showed a higher concentration of stresses in the FPD with one piece infrastructure (G1) and a lower concentration in the prosthesis obtained by CAD/CAM method (G4 and G5). When submitted to distributed occlusal loading, the FPD with Zr infrastructure (G5) showed a considerable increase in stress concentration, followed by one piece (G1) and those that were laser (G2) and TIG (G3) welded. In the cantilever load, the TIG welded Co-Cr infrastructure (G3) showed the highest stress concentration. Within the limitations of this study, it was concluded that FPDs with infrastructures obtained by the CAD/CAM system were associated with lower stress concentrations and that the section of metal infrastructures for later welding may also be a viable alternative, according to the peri-implant stress distribution.
73

Avaliação da precisão da adaptação de próteses sobre implantes, fundidas em monobloco, com ligas de Ni-Cr e Co-Cr e em Ti cp, antes e após soldagem a laser e após a simulação da aplicação de cerâmica / Evaluation of the precision of fit of one-piece implant-retained and supported prostheses cast in Ni-Cr and Co-Cr alloys and Cp Ti, before and after laser welding and after simulated porcelain firing cycles

Tiossi, Rodrigo 26 May 2006 (has links)
O objetivo deste estudo foi avaliar o assentamento passivo de supra-estruturas de próteses fixas implanto-suportadas de três elementos, fundidas em titânio comercialmente puro e em ligas à base de Ni-Cr e Co-Cr. Para esta análise foi utilizado o método de Sheffield (EISENMAN, 1997), e as leituras foram realizadas num microscópio óptico comparador (Nikon, Japão). Foram utilizados dois implantes de hexágono interno Master Conect AR (Conexão Sistemas de Prótese, Brasil). Os dados foram submetidos à análise de variância (ANOVA) e também ao teste complementar de Tukey-Kramer. A análise dos dados permitiu concluir que: as interfaces, quando os três grupos foram analisados em monobloco e com os dois parafusos apertados, foram mais satisfatórias para o grupo fundido em liga de Ni-Cr (25,00 ± 7,92&#956;m), apesar deste grupo não ser estatisticamente diferente dos outros dois (Co-Cr: 54,23 ± 37,10&#956;m e Ti cp: 48,41 ± 26,69&#956;m). No teste do parafuso único os três grupos também foram estatisticamente iguais, com os seguintes resultados, no lado parafusado: Co-Cr: 35,01 ± 27,76&#956;m, Ni-Cr: 20,13 ± 7,97&#956;m, e Ti cp: 22,28 ± 17,29&#956;m, e no lado contrário: Co-Cr: 118,64 ± 91,48&#956;m, Ni-Cr: 70,66 ± 20,88&#956;m, e Ti cp: 118,56 ± 51,35&#956;m. Neste mesmo estudo também se realizou a secção das peças e posterior soldagem a laser. A soldagem foi conduzida na máquina Desktop Laser (Dentaurum, Alemanha). A análise do assentamento passivo foi novamente realizada pelo método de Sheffield e as leituras foram feitas no microscópio óptico comparador (Nikon). O procedimento de separação das peças em monobloco e posterior soldagem a laser resultou em diminuição estatisticamente significante nos níveis de desajuste quando analisadas as peças com os dois parafusos apertados para o grupo fundido em liga de Co-Cr (21,49 ± 9,08&#956;m). Para os outros dois grupos, liga de Ni-Cr (13,10 ± 1,81&#956;m) e Ti cp (17,70 ± 11,70&#956;m), os resultados não apresentaram diferenças estatisticamente significantes, apesar de apresentarem menores níveis de desajuste marginal. No teste do parafuso único e leitura no lado oposto, apenas o grupo fundido em liga de Ni-Cr (19,81 ± 7,36&#956;m) não apresentou diferença estatisticamente significante quando comparado à fundição em monobloco. Os grupos em liga de Co-Cr (41,02 ± 26,15&#956;m) e em Ti cp (40,42 ± 27,14&#956;m) apresentaram diferenças estatisticamente significantes após a soldagem a laser. Na leitura no lado apertado os três grupos foram estatisticamente iguais. A simulação dos ciclos de queima da cerâmica não provocou alterações significativas nas interfaces analisadas sob todas as condições de leitura e aperto dos parafusos. Os grupos fundidos em ligas de Co-Cr e em Ti cp, quando analisados com apenas um parafuso apertado e as leituras realizadas no lado oposto, apresentaram diminuição dos níveis de ajuste, sendo 26,42 ± 8,67&#956;m, após a simulação, quando era 41,02 ± 26,15&#956;m após soldagem a laser para o primeiro e, 40,42 ± 27,14&#956;m e 28,05 ± 20,89&#956;m, antes e após a simulação, para o segundo, porém sem diferenças estatisticamente significantes. / The purpose of this study was to evaluate the precision of fit of three-element implant-retained and supported frameworks, cast in Ni-Cr- and Co-Cr alloys and commercially pure titanium (Cp Ti). The Sheffield´s test (EISENMAN, 1997) was used to analyze the marginal interfaces, and the readings executed in an optic microscope (Nikon, Japan). Two Master Conect AR (Conexão Sistemas de Prótese, Brazil) internal-hexagon implant systems were used. Data were submitted to analysis of variance (ANOVA) with complementary Tukey-Kramer’s test. Data analysis showed that: the interfaces, when analyzed as a one-piece casting and with both screws tightened, were better for the group cast in Ni-Cr alloy (25.00 ± 7.92&#956;m), though not statistically different from the two other groups (Co-Cr: 54.23 ± 37.10&#956;m e Cp Ti: 48.41 ± 26.69&#956;m). In the single screw tightened test the three groups showed no statistical difference, with the following results, on the tightened side: Co-Cr: 35.01 ± 27.76&#956;m, Ni-Cr: 20.13 ± 7.97&#956;m, and Cp Ti: 22.28 ± 17.29&#956;m, and on the opposite side: Co-Cr: 118.64 ± 91.48&#956;m, Ni-Cr: 70.66 ± 20.88&#956;m, and Cp Ti: 118.56 ± 51.35&#956;m. On this same study, the one-piece castings were sectioned and laser welded. The laser welding was executed with the Desktop Laser (Dentaurum, Germany) machine. The Sheffield´s test was used to analyze the passive fit, and the readings executed in an optic microscope (Nikon). The procedure of sectioning the one-piece castings and its later laser welding presented statistically significant lower levels of misfit when the castings were analyzed with both screws tightened for the group cast in Co-Cr alloy (21.49 ± 9.08&#956;m). For the other two groups, Ni-Cr alloy (13.10 ± 1.81&#956;m) and Cp Ti (17.70 ± 11.70&#956;m), results presented no statistically significant differences, though showed lower levels of marginal fit. In the single screw tightened test and readings made on the opposite side, only the group cast on Ni-Cr alloy (19.81 ± 7.36&#956;m) didn’t present statistically significant lower levels of misfit when compared to single-piece castings. The Co-Cr alloy (41.02 ± 26.15&#956;m) and the Cp Ti (40.42 ± 27.14&#956;m) groups showed statistically significant differences after laser welding. The reading on the screwed side detected that the three groups were statistically the same. Simulation of the porcelain firing cycles did not develop any significant differences on the analyzed interfaces under all readings and screw tightening conditions. The groups cast in Co-Cr alloy and Cp Ti, when analyzed with only one screw tightened and the readings executed on the opposite side, presented lower levels of misfit, being 26.42 ± 8.67&#956;m, after simulation, when was 41.02 ± 26.15&#956;m after laser welding for the first and, 40.42 ± 27.14&#956;m and 28.05 ± 20.89&#956;m, before and after, for the second, though not showing any statistically significant differences.
74

Estudo da correlação entre adaptação marginal e tensões transmitidas aos implantes por estruturas metálicas fundidas em monobloco - análise fotoelástica. / A study of the correlation between marginal fit and tensions transmitted to implants by one-piece metal castings - a photoelastic analysis.

Érica Miranda de Torres 19 December 2005 (has links)
Um dos maiores obstáculos para o sucesso das reabilitações com próteses sobre implantes consiste na obtenção de boa adaptação marginal dos componentes protéticos. Não está claro na literatura quais níveis de desajuste são considerados clinicamente aceitáveis, mas sabe-se que a ausência de perfeito ajuste e assentamento passivo pode provocar tensões inadequadas na interface de osseointegração, possibilitando problemas mecânicos e biológicos. A fotoelasticidade é uma técnica experimental para análise de tensões capaz de produzir resultados bastante confiáveis e fiéis aos parâmetros clínicos. Quando estruturas metálicas para próteses sobre múltiplos implantes são fundidas em monobloco, a obtenção de boa adaptação marginal parece ser ainda mais crítica. Contudo, não se verificam estudos que abordem a influência do tipo de metal ou liga empregado nessas fundições sobre os níveis de desadaptação protética. Assim, o presente estudo tem como objetivos verificar a adaptação marginal entre os pilares intermediários e estruturas fundidas em monobloco com diferentes materiais; avaliar, pelo método fotoelástico, as tensões impostas aos implantes quando a eles são fixadas as estruturas metálicas; e ainda pesquisar possíveis correlações entre os níveis de adaptação marginal e as tensões geradas na interface implante-material fotoelástico. Para tanto, utilizando cilindros calcináveis, foram enceradas 15 estruturas para próteses implanto-retidas sobre modelo simulando o posicionamento de cinco implantes na região intermentoniana. As estruturas foram divididas em grupos de cinco e fundidas em monobloco com titânio comercialmente puro grau I, liga de cobalto-cromo ou liga de níquel-cromo-titânio. A adaptação marginal foi avaliada, em microscópio ótico, quanto à passividade, por meio do teste de único parafuso, com aperto alternado nos implantes distais A e E, e quanto aos níveis de desajuste vertical, com todos os parafusos apertados com um torque de 10Ncm. As tensões geradas na área correspondente à região de crista óssea marginal em torno dos implantes foram avaliadas por meio de análise fotoelástica quantitativa empregando o método de compensação de Tardy. Após análise estatística dos resultados (p<0.05), verificou-se que, nos testes de passividade, o Ti cp apresentou resultados significantemente superiores de adaptação quando comparado as ligas de Co-Cr e Ni-Cr-Ti, as quais não apresentaram diferenças estatísticas entre si. O Ti cp foi semelhante à liga de Ni-Cr-Ti quanto aos níveis de desajuste vertical e tensões impostas aos implantes, com resultados superiores àqueles obtidos com a liga de Co-Cr. Foram aplicados testes de correlação entre as tensões fotoelásticas e os seguintes parâmetros: desajuste vertical, passividade média, adaptação marginal absoluta e percentual de redução de desajuste. Verificou-se correlação significante apenas entre os valores de adaptação marginal absoluta e tensões geradas pelas estruturas de Ni-Cr-Ti. Pode-se concluir que estruturas para próteses fixas sobre múltiplos implantes fundidas em monobloco podem produzir níveis biologicamente aceitáveis de desajuste, sendo os melhores resultados obtidos com o Ti cp, seguido das ligas de Ni-Cr-Ti e Co-Cr, respectivamente. Dentre os metais avaliados, a liga de Co-Cr transmitiu maiores níveis de tensões aos implantes. De um modo geral, não foram verificadas correlações entre valores de adaptação marginal e tensões impostas aos implantes. / Obtaining a good marginal fit of the prosthetic components is one of the main obstacles to the success of rehabilitation with implant-supported prostheses. It is not clear, in the literature, which misfit levels are considered clinically acceptable, but it is known that the absence of a perfect and passive fit may cause inadequate tensions on the osseointegration interface, which may bring about mechanical and biological problems. Photoelasticity is an experimental technique, used to analyze tensions, which is capable of producing results that are reliable to clinical parameters. When metal multiple-unit implant frames are cast in a single unit, it seems that obtaining a good marginal fit is even more critical. However, there are no studies in the literature about the influence that the type of metal or alloy used in these castings may have on the levels of prosthesis misfit. Thus, the present study has the aim to verify the marginal fit between the intermediate abutments and the one-piece structures cast with different materials; perform a photoelastic assessment of the tensions caused on implants when metal frames are fixed to them; and, research the possible correlations between the levels of marginal fit and the tensions generated on the interface implant-photoelastic material. To do this, 15 frames for implant-retained prostheses were waxed, using calcinable cylinders, simulating the positioning of five implants on the inter-mentalis region. The frames were divided into groups (n=5) and cast in a single piece with commercially pure titanium grade I, cobalt-chrome alloy, or nickel-chrome-titanium alloy. Marginal fit was assessed by optic microscopy, in terms of passivity, by a single screw test with alternate tightening on the distal implants A and E. As to the levels of vertical misfit, all screws were tightened to a torque of 10Ncm. Tensions generated in the area corresponding to the marginal bone crest region surrounding the implants were assessed by quantitative photoelastic analysis using the Tardy compensation method. After the statistical analysis of the results (p<0.05), it was verified that, in the passivity tests, the Ti cp showed significantly superior fitting results when compared to the Co-Cr and Ni-Cr-Ti alloys, which showed no statistically significant differences between them. In terms of the levels of vertical misfit and tensions over the implants, Ti cp was similar to the Ni-Cr-Ti alloy, showing superior results when compared to the Co-Cr alloy. Correlation tests were performed between the photoelastic tensions and the following parameters: vertical misfit, mean passivity, absolute marginal fit, and percentage of misfit reduction. A significant correlation was observed only between the values of absolute marginal fit and the tensions generated by the Ni-Cr-Ti frames. It is concluded that one-piece cast multiple-unit implant frames may produce biologically acceptable misfit levels, and the best results are obtained with Ti cp, followed by the Ni-Cr-Ti and Co-Cr alloys, respectively. Among the assessed metals, the Co-Cr alloy transmitted higher tension levels to the implants. In a general way, no correlations were observed between the values of marginal fit and tensions on implants.
75

Influência do material e técnica de obtenção da infraestrutura na distribuição de tensão de próteses parciais fixas com cantilever / Influence of material and infrastructure obtaining techniques on the stress distribution of cantilever fixed partial dentures

Bruna Santos Honório Tonin 23 January 2017 (has links)
A passividade da prótese parcial fixa (PPF) sobre implante e a distribuição de tensões ao osso pela infraestrutura, contribuem não só com a osseointegração como também para a sua manutenção. A análise de tensões por fotoelasticidade permite visualizar as magnitudes de tensões e deformações em um modelo confeccionado em resina fotoelástica que possui padrão de concentração e distribuição de tensões semelhantes ao tecido ósseo. Assim, este estudo teve como objetivos comparar a distribuição de tensões de PPFs associadas à cantilever com diferentes materiais de infraestrutura (Co-Cr e Zircônia [Zr]) e métodos de obtenção (CAD/CAM e fundição convencional [monobloco, soldagem a laser e soldagem com TIG]), quando submetidos a diferentes carregamentos oclusais (puntiforme e oclusal distribuído). A partir de um modelo mestre, foram confeccionados 3 modelos fotoelásticos simulando extremidade livre mandibular,com o dente 44 em resina e 2 implantes substituindo os dentes 45 e 46. Os grupos deste estudo incluíram PPFs com infraestruturas obtidas por meio de fundição convencional em monobloco (G1), seccionadas e soldadas a laser (G2) e com TIG (G3) e obtidas por meio do sistema CAD/CAM em Co-Cr (G4) e Zr (G5). As PPFs foram parafusadas sobre os mini pilares e submetidas a carregamento oclusal puntiforme e distribuído (150 N) para avaliação qualitativa das franjas e quantitativa em seis diferentes pontos: apical (P1) e distal (P2) do dente 44, apical (P3) e distal (P4) do implante substituindo o dente 45, apical (P5) e distal (P6) do implante substituindo o dente 46. A análise fotoelástica mostrou maior concentração de tensões na PPF com infraestrutura em monobloco (G1) e menor concentração nas próteses obtidas pelo método CAD/CAM (G4 e G5). Quando submetidos ao carregamento oclusal distribuído, a PPF com infraestrutura em Zr (G5) apresentou um aumento considerável na concentração de tensões, seguida por monobloco (G1) e as que foram soldadas a laser (G2) e TIG (G3). No carregamento pontual sobre o cantilever, a infraestrutura em Co-Cr soldada a TIG (G3) mostrou a maior concentração de tensões. Dentro das limitações deste estudo, concluiu-se que PPFs com infraestruturas obtidas por meio do sistema CAD/CAM foram associadas com menor concentração de tensões e que a secção de infraestruturas metálicas para posterior soldagem pode também ser uma alternativa viável, de acordo com a distribuição de tensões peri-implantes. / The passivity of fixed partial denture (FPD) on implant and the stress distribution to the bone by the infrastructure, contribute not only to osseointegration but also to its maintenance. The stress analysis by photoelasticity allows visualizing the stresses and deformations magnitudes in a model fabricated in photoelastic resin that has a concentration pattern and stress distribution similar to the bone tissue. The aim of this study was to compare the stress distribution of cantilever FDPs with different infrastructure materials (Co-Cr and Zirconia [Zr]) and methods of manufacture (CAD/CAM and conventional casting [one piece, laser welding and welding with TIG]), when submitted to different occlusal loads (punctiform and distributed occlusal). From a master model, 3 photoelastic models were fabricated to simulate the mandibular free end, with the tooth 44 in resin and 2 implants replacing the teeth 45 and 46. The groups of this study included FPDs with infrastructures obtained by conventional casting in one piece (G1), sectioned and laser welded (G2) and TIG (G3) and obtained by the CAD/CAM system in Co-Cr (G4) and Zr (G5). The FDPs were screwed onto the abutments and subjected to punctate and distributed occlusal loading (150 N) for qualitative evaluation of the fringes and quantitative at six different points: apical (P1) and distal (P2) of the tooth 44, apical (P3) and distal (P4) of the implant replacing the tooth 45, apical (P5) and distal (P6) of the implant replacing the tooth 46. The photoelastic analysis showed a higher concentration of stresses in the FPD with one piece infrastructure (G1) and a lower concentration in the prosthesis obtained by CAD/CAM method (G4 and G5). When submitted to distributed occlusal loading, the FPD with Zr infrastructure (G5) showed a considerable increase in stress concentration, followed by one piece (G1) and those that were laser (G2) and TIG (G3) welded. In the cantilever load, the TIG welded Co-Cr infrastructure (G3) showed the highest stress concentration. Within the limitations of this study, it was concluded that FPDs with infrastructures obtained by the CAD/CAM system were associated with lower stress concentrations and that the section of metal infrastructures for later welding may also be a viable alternative, according to the peri-implant stress distribution.
76

Influência de tratamentos superficiais e termociclagem na resistência da união resina/metal

Almilhatti, Hercules Jorge [UNESP] 27 April 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-04-27Bitstream added on 2014-06-13T19:44:48Z : No. of bitstreams: 1 almilhatti_hj_dr_arafo.pdf: 2065564 bytes, checksum: 9ca5fe747a7a70b66a300c7564a4ad19 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo teve como objetivo avaliar a efetividade de quatro condicionadores de metal (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL e Siloc, S) aplicados sobre diferentes superfícies das ligas de Ni-Cr, Co-Cr e do metal Ti Cp. Após o polimento metalográfico e jateamento com Al2O3, foram obtidos três grupos experimentais para cada metal : Grupo polimento (P) - controle; Grupo (J50), jateado com Al2O3 de 250 um. A esses grupos foram aplicados os condicionadores e as resinas opaca e de revestimento estético (Artglass). Decorridos 24 horas de armazenamento em água a 37ºC, cada grupo foi dividido em dois grupos e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min.), um antes e outro após 500 ciclos térmicos (60ºC e 4ºC). As superfícies fraturadas foram analisadas e o padrão de falhas determinado. Adicionalmente foram feitas análises de MEV e EDS. Seguem os resultados para cada metal: Liga de Ni-Cr: para os Grupos P e J50, não foram observadas diferenças (p>0,05) nos valores médios de tensão de cisalhamento entre os condicionadores OP e TL e entre MPP e S, sendo maiores as médias dos dois primeiros. Não foram encontradas diferenças (p>0,05) entre as médias de tensão para os condicionadores do Grupo J250. No entanto, esses valores foram superiores aos do Grupo J50. Após a termociclagem, as médias para os condicionadores OP, S e TL não apresentaram aumento significante (p>0,05), enquanto a média para o MPP aumentou (p<0,05). Liga de Co-Cr, para o Grupo P, não foram observadas diferenças (p>0,05) nos valores médios de tensão entre os condicionadores OP e TL e entre MPP e S, sendo superiores as médias dos dois primeiros. As médias de tensão para o Grupo J250 foram estatisticamente maiores às do Grupo J50,... / The purpose of the study was to evaluated the effect of three adhesive primers (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL) and a bonding system (Siloc, S) on the shear bond strength between a prosthetic composite material (Artglass) to Ni-Cr alloy (Wiron 99), Co-Cr alloy (Wironit), and CP Ti (Tritan). Disk patterns were cast of the 3 alloys. All the disk surfaces were abraded with No. 80, 320, and 600 SiC paper, respectively and three different surface treatment were applied: No. 600 SiC polishing, P; 50 mm Al2O3 sandblasting, S50; 250 mm Al2O3 sandblasting, S250. The composites (Artglass opaque and dentin) were applied using a cylindrical stainless steel split according to manufacturer's instructions then light polymerized. Specimens without primer and bonding system were also prepared as control. The specimens were stored in water a 37oC for 24 h and then shear bond strengths were determined both before and after immersed alternately in water baths at 4oC and 60oC for 15 seconds each for up to 500 thermal cycles before shear mode testing at a crosshead speed of 0.5 mm/min. Data were statistically analyzed using 3-way ANOVA and 1-way ANOVA, followed by Tukey multiple range intervals calculated at the 0.05 significance level. Fractured interfaces were analyzed by use of light microscopy and SEM. Results: Ni-Cr alloy: The bond strength of the P-OP/J50-OP group and P-TL/J50- TL group were statistically comparable (p>0,05) and exhibited greater strength than the P-MPP/J50-MPP group and P-S/J50-S (p<0,05). No significant differences were found among the four conditioners for J250 group (p>0,05), and these group showed the greater strength than the J50 group (p<0,05). After thermocycling, no significant differences (p>0,05) were found among the three primers (OP, S, TL) and the bond strength of MPP increased...(Complete abstract, click electronic access below)
77

Efeito da concentração do líquido especial e da temperatura do molde de revestimentos na desadaptação marginal de coroas fundidas em titânio

Rocha, Sicknan Soares da [UNESP] 08 July 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-07-08Bitstream added on 2014-06-13T18:45:58Z : No. of bitstreams: 1 rocha_ss_dr_arafo.pdf: 430614 bytes, checksum: 1571700915ba54139efb728fbcc0dc8e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar o efeito da concentração do líquido especial e da temperatura do molde dos revestimentos Rematitan Plus, específico para titânio, Rema Exakt e Castorit Super C, alternativos, na desadaptação marginal de coroas fundidas em titânio puro. Para o revestimento Rematitan Plus os padrões de cera foram incluídos à vácuo com três diferentes concentrações do líquido especial, 100%, 75% e 50%, diluídos em água destilada. As fundições foram realizadas na máquina Discovery Plasma com os moldes em três temperaturas, 430ºC, 515ºC e 600ºC. Os revestimentos alternativos foram empregados nas condições em que obtiveram expansão total de 0,8%, equivalente à do Rematitan Plus (100%/430ºC), adotado como grupo controle. Conforme as curvas de expansão de presa e térmica foram estabelecidas as condições de concentração e temperatura: Rema Exakt (100%/220ºC, 75%/240ºC e 50%/340ºC) e Castorit Super C (100%/temperatura ambiente e 75%/160ºC). / This study had the goal of assessing the effect of the concentration of the special liquid and the temperature of the mold of Rematitan Plus investment, specific for titanium, Rema Exakt and Castorit Super C, alternative investments, on the marginal misfit of crowns cast on pure titanium. For the Rematitan Plus investment, the wax standards were included in vacuum with three different concentrations of the special liquid, 100%, 75% and 50%, diluted in distilled water. The castings were performed on the Discovery Plasma machine with the molds at three temperatures, 430ºC, 515ºC and 600ºC. The alternative investments were employed under conditions in which they obtained a overall expansion of 0.8%, equivalent to that of the Rematitan Plus (100%/430ºC), adopted as the control group. According to the thermal and setting expansion curves the conditions of concentration and temperature were established: Rema Exakt (100%/220ºC, 75%/240ºC and 50%/340ºC) and Castorit Super C (100%/room temperature and 75%/160ºC).
78

Efeito da concentração do líquido especial e da temperatura do molde de revestimentos na desadaptação marginal de coroas fundidas em titânio /

Rocha, Sicknan Soares da. January 2005 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da concentração do líquido especial e da temperatura do molde dos revestimentos Rematitan Plus, específico para titânio, Rema Exakt e Castorit Super C, alternativos, na desadaptação marginal de coroas fundidas em titânio puro. Para o revestimento Rematitan Plus os padrões de cera foram incluídos à vácuo com três diferentes concentrações do líquido especial, 100%, 75% e 50%, diluídos em água destilada. As fundições foram realizadas na máquina Discovery Plasma com os moldes em três temperaturas, 430ºC, 515ºC e 600ºC. Os revestimentos alternativos foram empregados nas condições em que obtiveram expansão total de 0,8%, equivalente à do Rematitan Plus (100%/430ºC), adotado como grupo controle. Conforme as curvas de expansão de presa e térmica foram estabelecidas as condições de concentração e temperatura: Rema Exakt (100%/220ºC, 75%/240ºC e 50%/340ºC) e Castorit Super C (100%/temperatura ambiente e 75%/160ºC). / Abstract: This study had the goal of assessing the effect of the concentration of the special liquid and the temperature of the mold of Rematitan Plus investment, specific for titanium, Rema Exakt and Castorit Super C, alternative investments, on the marginal misfit of crowns cast on pure titanium. For the Rematitan Plus investment, the wax standards were included in vacuum with three different concentrations of the special liquid, 100%, 75% and 50%, diluted in distilled water. The castings were performed on the Discovery Plasma machine with the molds at three temperatures, 430ºC, 515ºC and 600ºC. The alternative investments were employed under conditions in which they obtained a overall expansion of 0.8%, equivalent to that of the Rematitan Plus (100%/430ºC), adopted as the control group. According to the thermal and setting expansion curves the conditions of concentration and temperature were established: Rema Exakt (100%/220ºC, 75%/240ºC and 50%/340ºC) and Castorit Super C (100%/room temperature and 75%/160ºC). / Orientador: Gelson Luis Adabo / Coorientador: Ricardo Faria Ribeiro / Banca: Marco Antonio Compagnoni / Banca: Carlos Alberto dos Santos Cruz / Banca: Mauro Antônio de Arruda Nóbilo / Banca: Cláudio Rodrigues Leles / Doutor
79

Estudos eletroquímicos in vitro e in vivo da liga níquel–cromo–molibdênio– titânio aplicada em supraestruturas de implantes orais / In vitro and in vivo electrochemical studies of nickel-chromium-molybdenum-titanium alloy applied to oral implant suprastructures

Eduardo Inada 21 October 2005 (has links)
Este trabalho avaliou o comportamento eletroquímico da liga de níquel-cromo-molibdênio- titânio em relação à liga ouro-platina-paládio em meio de NaCl 0,15 mol.L -1 a 36,5ºC. Os estudos in vitro também envolveram a caracterização eletroquímica do titânio, uma vez que as referidas ligas são empregadas em supraestruturas de implantes osseointegrados. Os estudos in vivo foram feitos com as ligas formando par com titânio comercialmente puro grau IV. Nos estudos in vitro, foram utilizadas técnicas de medidas de potencial de circuito aberto, curvas de polarização anódica e espectrofotometria de absorção atômica de chama. Os estudos in vivo foram interpretados utiliza ndo a microscopia eletrônica de varredura e a espectroscopia por dispersão de energia. A liga de ouro-platina-paládio e o titânio apresentaram resultados reprodutíveis. Suas superfícies são homogêneas e os valores de potencial de circuito aberto estacionário dos dois materiais diferem de menos de 100 mV. A permanência da liga ouro-platina-paládio junto do titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, a estabilidade da liga áurica e do titânio. A liga de níquel-cromo-molibdênio-titânio não apresentou reprodutibilidade nos resultados de potencial de circuito aberto e nas curvas de polarização anódica, apresentando uma faixa de pontencial muito reduzida de passividade, 100 mV. Na análise pela espectrofotometria de absorção atômica de chama, a liga ouro-platina-paládio apresentou pequena divergência com os dados fornecidos pelo fabricante, mostrando conter, além do ouro, platina e paládio, cerca de 1% de prata. A liga níquel-cromo-molibdênio-titânio, na análise pela espectrofotometria de absorção atômica, apresentou grandes divergências com os dados fornecidos pelo fabricante, fora da faixa de composição em que foi patenteada. Foi detectada a presença de alumínio em quantidade significativa, elemento não declarado pelo fabricante. O teor de níquel está acima da especificação, enquanto que o teor de titânio e de cromo se encontram abaixo. A análise por microscopia eletrônica de varredura com igual amplificação empregada para o estudo da liga áurica e do titânio, revelou que a liga níquel-cromo-molibdênio-titânio apresenta superfície heterogênea, caracterizada por quatro fases distintas: (fase 1 – rica em titânio; fase 2 – rica em níquel; fase 3 – rica em níquel e cromo; fase 4 – rica em molibdênio). A permanência da liga de níquel-cromo-molibdênio-titânio junto ao titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, na análise por elétrons secundários, depressões na superfície da amostra na fase 2, sugerindo oxidação da fase rica em níquel, evidenciada pela presença de oxigênio superficial, quando comparada à mesma fase na superfície apenas polida. / The electrochemical behavior of the nickel-chromium-molybdenum-titanium (Ni-Cr-Mo-Ti) alloy was studied and compared to a gold-platinum-palladium (Au-Pt-Pd) alloy in 0.15 mol.L -1 NaCl medium at 36.5ºC. In vitro studies also involved the electrochemical titanium characterization since these alloys are employed in osseointegrated implant suprastructures. In vivo studies were made using alloy-titanium (Ti cp) couples. Open circuit potential (OCP) measurements, anodic polarization curves (APC) and flame atomic absortion spectrophotometry (FAAS) were used as techniques in in vitro experiments. Scanning electronic microscopy (SEM) and energy dispersion spectroscopy (EDS) were used in order to interpret in vivo experiments. The Au-Pt-Pd alloy and Ti showed reproducible results. Their surfaces are homogeneous and the stationary OCP values of the two materials differ by a value less than 100 mV. The permanence of Au-Pt-Pd alloy near titanium for six months in oral environment showed by SEM the stability of the two materials. The Ni-Cr- Mo-Ti alloy did not show reproducibility in OCP and APC results, exhibiting narrow potential range of passivity about 100 mV. The Au-Pt-Pd alloy, under FAAS analysis, presented some divergence in the chemical composition when compared to that one previously provided by the manufacturer. FAAS detected 1% weight of silver. The Ni-Cr-Mo-Ti alloy, however, presented significant divergences and a chemical composition different from that one corresponding to the patent. The presence of aluminum not declared by the manufacturer was detected in meaningful amounts. SEM analysis of Ni-Cr-Mo-Ti alloy with the same amplification used for Au-Pt- Pd alloy and Ti showed a heterogeneous surface characterized by four phases: phase 1 – rich in titanium; phase 2 – rich in nickel; phase 3 – rich in nickel and chromium; phase 4 – rich in molybdenum. The permanence of Ni-Cr-Mo-Ti alloy,for six months in oral environment, showed by SEM using secondary electrons, depressions on the phase 2 area, suggesting oxidation of the rich nickel phase, with a significant oxygen presence, when compared to the correspondent area on the polishing surface.
80

Estudo in vivo e in vitro da corrosão de ligas de Co-Cr e de Ni-Cr utilizadas em estruturas protéticas de implantes orais / In vitro and in vivo studies of corrosion of Co-Cr and Ni-Cr alloys used in oral implant prosthetic superstructures

Eduardo Inada 13 August 2013 (has links)
Este trabalho avaliou o comportamento eletroquímico de três ligas de níquel-cromo e duas de cobalto-cromo in vitro e in vivo. Nos estudos in vitro foram fabricados eletrodos de trabalho a partir destas ligas. Estes eletrodos ficaram imersos em meio de NaCl 0,15 mol.L-1 a 36,5°C e foram submetidos às técnicas do potencial de circuito aberto, polarização potenciostática anódica e cronoamperometria. Para os estudos in vivo foram selecionados quinze pacientes com implantes já osseointegrados e aguardando a instalação das próteses. Esses pacientes foram distribuídos aleatoriamente em cinco grupos, correspondentes às cinco ligas diferentes. Deste modo, as estruturas protéticas dos implantes foram fundidas utilizando as cinco ligas. Foi utilizada a microscopia eletrônica de varredura (MEV) e a espectroscopia por dispersão de energia (EDS) como métodos de análise das superfícies linguais metálicas das próteses, antes da instalação em ambiente oral e após seis meses de permanência. Vistas por MEV, as ligas duas de cobalto-cromo Starloy C e Remanium 2001 e duas de níquel-cromo Wiron 99 e Remanium CSe apresentaram superfícies heterogêneas caracterizadas por uma fase semelhante à matriz da liga e a outra fase, composta por elementos de maior densidade atômica, correspondente à fase interdendrítica. Após seis meses, não houve sinais de corrosão e alterações significativas na composição destas ligas. As ligas de Co-Cr avaliadas, sob o ponto de vista eletroquímico, indicam comportamento catódico quando unidas ao implante sendo um fator indicativo de proteção à corrosão. Dentro dos limites dos estudos in vitro, as ligas de Ni-Cr apresentaram um filme passivo com ampla faixa de potencial em que se mantêm passiva e ausência de corrosão localizada. A liga de níquel-cromo Dan Ceramalloy apresentou a superfície heterogênea com quatro áreas distintas (área 1 rica em titânio; área 2 rica em níquel; área 3 correspondente à matriz; área 4 rica em molibdênio). Após seis meses, as três próteses metalo-cerâmicas apresentaram as regiões correspondentes à fase 2, rica em níquel, com depressões em baixo relevo, sugerindo a oxidação com a liberação de íons níquel. Nos estudos in vitro a liga Dan Ceramalloy apresenta potencial de corrosão mais negativo, uma faixa passiva de potencial mais estreita e um filme menos protetor, quando comparada com as demais ligas estudadas. Apesar de não ter sido observado clinicamente o processo de corrosão das ligas, os estudos in vitro e in vivo deste material, permitiram verificar o seu comportamento eletroquímico e sugerir a descontinuidade do seu emprego em estruturas protéticas de implantes orais. Os estudos in vitro e in vivo apresentaram concordância para todos os materiais estudados. / In this study, the electro-chemical behavior of three nickel-chrome and two cobalt chrome alloys was studied in vitro and in vivo. In the in vitro studies, working electrodes made of these alloys were fabricated. These electrodes were immersed in a medium of NaCl 0.15 mol.L-1 at 36.5°C and were submitted to the open circuit potential, anodic potentiostatic polarization and chronoamperometry techniques. For the in vivo studies, 15 patients whose implants had osseointegrated, and who were waiting for dental implant placement, were selected. These patients were randomly distributed into five groups, corresponding to the five different alloys. Thus the prosthetic implant superstructures were cast, using the five alloys. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used as methods to analyze the metal lingual surfaces of the prostheses, before they were placed in the oral environment, and after six months in place. Visualized by SEM, the two cobalt-chrome alloys Starloy C and Remanium 2001, and two types of nickel-chrome - Wiron 99 and Remanium Cse - presented heterogeneous surfaces characterized by a phase similar to that of the alloy matrix, and the other phase composed of elements of greater atomic density, corresponding to the interdendritic phase. After six months, there were no signs of corrosion and significant alterations in the composition of these alloys. The Co-Cr alloys evaluated, from an electrochemical point of view, indicated a cathodic behavior when united to the implant, this being a factor indicative of protection against corrosion. Within the limits of the in vitro studies, the Ni-Cr alloys presented a passive film with an ample range of potential in which they remained passive, with absence of corrosion due to pitting. The nickel-chrome alloy Dan Ceramalloy presented a heterogeneous surface with four distinct areas (Area 1 rich in titanium; Area 2 rich in nickel; Area 3 corresponding to the matrix; Area 4 rich in molybdenum). After six months, the three metal-ceramic dental prostheses presented the regions corresponding to Phase 2, rich in nickel, with depressions in low relief, suggesting oxidation with nickel ion release. In the in vitro studies, the alloy Dan Ceramalloy presented a more negative corrosion potential, a narrower range of passive potential and a less protective film, when compared with the other alloys studied. In despite of the process of corrosion of the alloys not having been clinically observed, the in vitro and in vivo studies of this material allowed verification of its electrochemical behavior, and suggest that its use in prosthetic superstructures for oral implants should be discontinued. The in vitro and in vivo studies were shown to be in agreement for all the materials studied.

Page generated in 0.0605 seconds