• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • 11
  • 6
  • 5
  • 2
  • Tagged with
  • 90
  • 90
  • 90
  • 28
  • 24
  • 23
  • 19
  • 12
  • 12
  • 11
  • 11
  • 11
  • 8
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Resistência à fratura de diferentes núcleos de preenchimento com compósitos bulk fill em dentes com extensa destruição coronária /

Oliveira, Carlos Rangel de Moura January 2019 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: Este estudo objetivou avaliar a resistência máxima e o padrão de fratura de diferentestécnicas para núcleo preenchimento associados a pinos de fibra de vidro em incisivoslaterais inferiores bovinos com extensa destruição coronária. Quarenta dentes forampreparados endodonticamente, divididos aleatoriamente em 4 grupos experimentais(n=10) e um pino de fibra de vidro (Whitepost DC0,5) foi cimentado com LuxaCore Zpara todos os grupos. A confecção dos núcleos de preenchimento foi realizada, apósobtenção de férula cervical de 1,0 mm, com: FOBF-Filtek One Bulk Fill; FZ350- FiltekZ350 XT; FBFF-Filtek Bulk Fill Flow; e LCZ-LuxaCore Z. Coroas totais de zircônia (YTZP) produzidas em CAD/CAM foram cimentadas com RelyX U200. Apósarmazenamento em água destilada a 37°C por 48 h, os corpos-de-prova foramsubmetidos a ciclos térmicos (10.000 ciclos, 5-55ºC, banhos de 30s) e, posteriormente,ao ensaio mecânico de resistência à fratura por força compressiva aplicada (1,0mm/min) em 135º ao longo eixo do dente em máquina eletromecânica (EMIC DL2000).A força máxima suportada por cada espécime foi registrada em Newton. O modo defratura foi classificado por meio de análise em lupa estereomicroscópica (30X). Osdados de resistência à fratura foram analisados pelo teste não paramétrico de KruskalWallis, seguido pelo post-hoc teste de Dunn. Os dados dos padrões de fratura foramanalisados pelo teste exato de Fisher (α=0,05). Não foram observadas diferençassignificativas (p>0... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the ultimate fracture strength and failure modes of different core techniques associated with intraradicular fiberpost in bovine mandibular lateral incisors with extensive coronary destruction. Forty teeth were prepared endodontically, randomly divided into 4 experimental groups (n=10) and a fiberpost (Whitepost DC0.5) was cemented with LuxaCore Z for all groups. The core was confeccioned, after obtaining a 1.0 mm cervical ferrule, with: FOBF-Filtek One Bulk Fill; FZ350- Filtek Z350 XT; FBFF-Filtek Bulk Fill Flow; and LCZ-LuxaCore Z. Total zirconia crowns (Y-TZP) produced by CAD/CAM were cemented with RelyX U200. After storage in distilled water at 37ºC for 48 h, the specimens were submitted to thermal cycling (10,000 cycles, 5- 55ºC, 30 s dwell time) and, afterwards, to the mechanical test of compressive strength fracture (1.0 mm / min) at 135º along the tooth axis in electromechanical machine (EMIC DL2000). The ultimate load supported by each specimen was recorded in Newton. The fracture mode was classified by means of stereomicroscopic loupe analysis (30X). The fracture strength data were analyzed by the non-parametric Kruskal-Wallis test, followed by the post-hoc Dunn test. The data of the fracture modes were analyzed by Fisher's exact test (α=0.05). No significant differences (p>0.05) were observed among the FOBF, FZ350 and FBFF groups (mean ranks= 20.30, 12.20 and 23.20, respectively). LCZ (mean rank= 26.30) produced similar results to those... (Complete abstract click electronic access below) / Mestre
82

As restaurações em lesões cervicais não cariosas pela “técnica sanduíche” apresentam taxas de retenção superiores à técnica restauradora com resina composta? uma revisão sistemática e meta-análise / The restorations in non-carious cervical lesions by the "sandwich technique" have superior retention rates when compared to the restorative technique with composite resin? a systematic review and meta-analysis

Paula, Alexandra Mara 20 January 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-09-12T13:54:13Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Alexandra Mara de Paula.pdf: 3202848 bytes, checksum: 71c3b52dd4c90886639413fccf850cdb (MD5) / Made available in DSpace on 2018-09-12T13:54:13Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Alexandra Mara de Paula.pdf: 3202848 bytes, checksum: 71c3b52dd4c90886639413fccf850cdb (MD5) Previous issue date: 2018-01-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objetivos: Esta revisão sistemática e meta-análise comparou as taxas de retenção de restaurações em lesões cervicais não cariosas (LCNCs) restauradas com a “técnica sanduíche” (uma base de cimento de ionômero de vidro [CIV] ou cimento de ionômero de vidro modificado por resina [CIVMR] + resina composta [RC]) ou restaurações de RC. Desfechos secundários como descoloração marginal, adaptação marginal, estabilidade de cor e cáries adjacentes às margens das restaurações também foram analisados. Métodos: Este estudo incluiu ensaios clínicos randomizados (ECRs) que compararam as taxas de retenção de LCNCs restauradas com a “técnica sanduíche” com restaurações de RC. A busca foi realizada na Biblioteca Cochrane, PubMed, Scopus e Web of Science, entre outras bases de dados. A literatura cinza foi inspecionada, bem como os resumos da IADR (1990-2017), em andamento e não publicados. A qualidade dos estudos foi avaliada usando a ferramenta de risco de viés Cochrane Collaboration. Os dados dos desfechos primários e secundários foram avaliados por meta-análise em diferentes seguimentos (um, dois e três anos). A qualidade do corpo de evidências foi avaliada usando a abordagem GRADE Resultados: Inicialmente, um total de 3.645 artigos foram selecionados. Após a seleção por títulos, resumos e textos completos, foram encontrados 6 artigos, mas três foram acompanhamentos do mesmo ECR e, portanto, um total de quatro estudos permaneceu para análise. Todos os estudos apresentaram risco de viés indefinido. De todos os desfechos, apenas a perda de retenção foi menor para a “técnica sanduiche” no seguimento de três anos (RR = 7,5; CI95% 2,1 a 27,2; p = 0,002). Conclusões: Maiores taxas de retenção em LCNCs restauradas com a “técnica sanduíche” foram observadas em comparação com restaurações de RC após três anos de avaliação. A descoloração marginal, estabilidade de cor, adaptação marginal e cáries adjacentes às margens das restaurações não foram influenciadas pela técnica restauradora. Com exceção das taxas de retenção, classificadas como moderadas, a qualidade das evidências dos outros desfechos foi classificada como baixa. / Objectives: This systematic review and meta-analysis compared the retention rates of non-carious cervical restorations (NCCLs) restored with the sandwich technique (a lining of glass ionomer cement [GIC] or resin-modified glass ionomer cement [RMGIC] + composite resin [CR]) or CR restorations. Secondary outcomes such as marginal discoloration, marginal adaptation, color match and secondary caries were also analyzed. Methods: This study included randomized clinical trials (RCTs) that compared the retention rates of NCCLs restored with the “sandwich technique” with CR restorations. The search was performed in Cochrane Library, PubMed, Scopus and Web of Science among other databases. Grey literature was inspected as well as the abstracts from the IADR (1990-2017), ongoing and unpublished. The quality of the studies was evaluated using the Cochrane Collaboration bias risk tool. Data of primary and secondary outcomes were meta-analyzed at different follow-ups (one; two and three-year) using the random effects model. The quality of the body of evidence was assessed using the GRADE approach Results: Initially, a total of 3.645 articles were selected. After selection by titles, abstracts and full texts, 6 articles were found, but three were follow-ups of the same RCT and therefore a total of four studies remained for analysis. All studies were at unclear risk of bias. From all outcomes, only loss of retention was lower for the “sandwich technique” at the three-year follow-up (RR = 7.5; 95% CI 2.1 to 27.2; p = 0.002). Conclusions: Higher retention rates in NCCLs restorations were observed with the sandwich technique compared to CR restorations after three years of evaluation. Marginal discoloration, color match, marginal adaptation and secondary caries were not influenced by the restorative technique. Except from retention rates, graded as moderate, the quality of the evidence of the other outcomes was graded as low.
83

Desempenho clínico de diferentes estratégias de adesão de restaurações de lesões cervicais não cariosas / Clinical performance of different accession strategies of non-carious cervical lesions restorations

Carvalho, Paulo Roberto Marão de Andrade [UNESP] 19 December 2016 (has links)
Submitted by PAULO ROBERTO MARÃO DE ANDRADE CARVALHO (DINTER) null (paulo@saolucas.edu.br) on 2017-02-13T19:20:07Z No. of bitstreams: 1 Tese Paulo Roberto Marao de Andrade Carvalho final.pdf: 1677819 bytes, checksum: c20c78af94d169f788debf8565ad1f21 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-02-15T13:33:28Z (GMT) No. of bitstreams: 1 carvalho_prma_dr_araca.pdf: 1677819 bytes, checksum: c20c78af94d169f788debf8565ad1f21 (MD5) / Made available in DSpace on 2017-02-15T13:33:28Z (GMT). No. of bitstreams: 1 carvalho_prma_dr_araca.pdf: 1677819 bytes, checksum: c20c78af94d169f788debf8565ad1f21 (MD5) Previous issue date: 2016-12-19 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: O objetivo deste estudo clínico controlado, prospectivo, randomizado e com avaliadores cegos foi avaliar o desempenho clínico de restaurações cervicais não cariosas frente às diferentes estratégias de adesão ao substrato dental. Métodos: foram utilizados um sistema restaurador adesivo (Single Bond Universal/Z350XT) com e sem condicionamento seletivo do esmalte e um cimento de ionômero de vidro modificado por resina (Vitremer) com e sem tratamento prévio com EDTA, seguindo as instruções do CONSORT. Um total de 200 restaurações foram realizadas por dois operadores em 50 pacientes voluntários. Previamente à execução das restaurações e em cada tempo de avaliação foram avaliados os índices de sangramento gengival, placa visível e CPOD. Todas as restaurações foram avaliadas por meio do sistema de avaliação do USPHS modificado. Dois examinadores calibrados, cegos e diferentes dos operadores realizaram as avaliações nos seguintes intervalos de tempo: inicial imediato (baseline), 6, 12 e 24 meses. Ao final de 24 meses os dados foram analisados pelos testes estatísticos de Friedman, Qui-quadrado, Kappa, Cochran, Wilcoxon e análise de regressão logística múltipla, adotando-se nível de significância a 5%. Resultados: a amostra foi composta de 34 homens e 16 mulheres com idade média de 61,8 anos. Em relação ao CPOD, houve um aumento gradativo e significante ao longo do tempo, havendo diferença entre os quatro tempos de avaliação (p≤0,001). Não teve diferença entre os tempos para o índice de placa visível (p=0,28). No entanto, houve uma redução significativa do índice de sangramento gengival entre o baseline e os demais tempos (p≤0,001). Não houve diferença estatisticamente significante entre os 4 grupos em cada tempo de avaliação em nenhum dos critérios avaliados (p>0,05), assim como não houve entre os 4 tempos de avaliação para todos os grupos (p>0,05). Em relação à regressão logística, embora não tenha apresentado nenhuma variável isolada como estatisticamente significante, o modelo como um todo apresentou-se estatisticamente significante (p=0,034). Conclusão: As quatro diferentes estratégias de adesão em restaurações cervicais não cariosas apresentaram similar desempenho clínico após 24 meses de acompanhamento. / Introduction: the aim of this study, prospective, randomized controlled clinical trial and with blind evaluators was to evaluate the clinical performance of non-carious cervical restorations to different strategies of adhesion for the dental substrate. Methods: we used a restorative adhesive system (Universal/Z350XT Single Bond) with and without selective etching of enamel and a modified glass ionomer luting cement for resin (Vitremer) with and without previous treatment with EDTA, following the instructions of the CONSORT. 200 in total restorations were performed by two operators in 50 patients. Prior to the execution of the restorations and each time, we evaluated the evaluation indexes of gum bleeding, visibly Board and CPOD. All restorations were evaluated using the evaluation system USPHS modified. Two calibrated examiners, blind and different operators, performed the evaluations in the following time intervals: immediate initial (baseline), 6, 12 e 24 months. At the end of 24 months data were analyzed by statistical tests Friedman, Qui-quadrado, Kappa, Cochran, Wilcoxon and multiple logistic regression analysis, adopting the significance level 5%. Results: the sample was composed of 34 men and 16 women with an average age of 61.8 years. Concerning the CPOD, there was a gradual and significant increase over time, difference between the four evaluation times (p≤0,001). There was no difference between the time the visible card index (p=0,28). However, there was a significant reduction of gingival bleeding index between the baseline and other times (p≤0,001). There was no statistically significant difference among the 4 groups in each time any of the assessment criteria evaluated (p>0,05), just as happened with the 4 times of evaluation for all groups (p>0,05). With regards to the logistic regression, although it has not presented any isolated variable as statistically significant, the model as a whole showed statistically significant (p=0,034). Conclusion: The four different adhesive strategies in non-carious cervical restorations showed similar clinical performance after 24 months of follow-up. / FAPESP: 2014/07086-0
84

Formação de fendas em restaurações de composito : tecnicas de avaliação, efeito de metodos de fotoavaliação e relação com a resistencia da união / Gap formation in composite restorations : evaluation techniques, effect of photoactivation methods and relantionship with bond strength

Alonso, Roberta Caroline Bruschi 22 February 2007 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T10:42:08Z (GMT). No. of bitstreams: 1 Alonso_RobertaCarolineBruschi_D.pdf: 2828251 bytes, checksum: 644a34bfa8b27efb0da35a9b5d7f13de (MD5) Previous issue date: 2007 / Resumo: A formação de fendas em restaurações de compósito foi caracterizada neste estudo, abrangendo-se técnicas de avaliação, fatores modificadores e a relação com a resistência de união das restaurações à estrutura dental. No capítulo 1, objetivou-se validar a técnica do corante para avaliação das fendas através da comparação com a observação em Microscopia Eletrõnica de Varredura (MEV). Vinte incisivos bovinos foram selecionados e desgastados até expor uma área plana em dentina, onde duas cavidades foram preparadas e restauradas com o compósito Filtek 2250 ou Filtek Flow. As amostras foram polidas e réplicas foram obtidas em resina epóxica. As réplicas foram observadas em MEV para determinar a porcentagem de fenda ao longo da margem cavitária. Na técnica do corante, Caries Detector (Kuraray) foi aplicado sobre as restaurações durante 5s. A imagem digital das restaurações coradas foi analisada com o software Image Tool para determinar a porcentagem de fendas. Os dados foram submetidos a ANOVA e teste de correlação de Pearson. Filtek Flow apresentou 35,54% e 33,52%, e Filtek 2250 26,68% e 29,11% de fendas, quando avaliadas em MEV e pela técnica do corante, respectivamente. Não houve diferença significativa entre os compósitos independente do método de avaliação, havendo forte correlação positiva (r=0,83) entre eles. Concluiu-se que a técnica do corante pode ser utilizada para avaliação das fendas com confiabilidade dos resultados. No capítulo 2, o efeito de métodos de fotoativação modulados na' adaptação marginal e intema de restaurações confeccionadas com diferentes compósitos foi determinado. Sessenta terceiros molares foram selecionados, seccionados (2 fragmentos) e tiveram a superfície vestibular ou palatina ou lingual desgastada para expor uma área plana em esmalte, onde uma cavidade foi confeccionada. Os dentes foram distribuídos em 12 grupos (n=lO), segundo o compósito restaurador (Filtek 2250, Herculite XRV e Heliomolar) e o método de foto ativação (Luz continua; Soft-Start; Pulse delay; Luz intermitente). O teste de adaptação marginal (técnica do corante) foi conduzido da mesma maneira descrita anterionnente. Após, os espécimes foram seccionados dividindo a restauração em 4 fatias, que foram coradas e o mesmo procedimento de avaliação da adaptação marginal foi realizado para determinar a adaptação intema. Assim, põde-se observar que todas as restaurações apresentaram perfeito selamento das margens extemas. Considerando as fendas intemas, os métodos modulados geraram redução significativa nas fendas quando comparados à luz contínua, independe do compósito empregado. Filtek 2250 apresentou a melhor adaptação interna, independente do método de fotoativação. A interação tipo de compósito e método de fotoativação não foi significativa. Conclui-se que os métodos de fotoativação modulados são eficientes na redução da formação de fendas internas e que podem ser indicados para a prática clínica, independente do compósito empregado. No capítulo 3, o objetivo foi relacionar a resistência da união à adaptação marginal e interna de restaurações fotoativadas por diferentes métodos. A resistência da união foi mensurada em cavidades tronco-conicas confeccionadas em dentes bovinos através do teste push-out (Instron). A adaptação marginal e interna das restaurações foi verificada da mesma maneira descrita anteriormente. Em ambos os testes, as cavidades foram restauradas com o compósito Esthet-X, sendo as amostras distribuídas em 5 grupos (n=10), de acordo com o método de fotoativação: G 1 - Luz contínua; G2 - Luz contínua baixa intensipade; G3 - Soft-start; G4 - Luz Intermitente; G5 - Pulse Delay. A dose de energia foi padronizada em 14J. Os dados foram submetidos a ANOVA e teste de Tukey. Considerando resistência da únião, G5 (7,2 MPa) apresentou resultados significativamente melhores que G 1 (4,6 MPa). G2, G3 e G4 tiveram médias intermediárias, não havendo diferenças significativas entre esses grupos e entre eles e G 1 ou G5. Considerando adaptação marginal, não houve diferença significativa entre os grupos. Na adaptação interna (que incluía o substrato dentinário), o resultado foi inverso ao do teste de resistência de união, ou seja, G5 (2,8%) teve menor média de fendas que G 1 (10,1%). Concluiu-se que a modulação da energia luminosa pode acarretar em aumento da resistência da união e redução na formação de fendas internas, havendo relação inversa entre resistência da união e formação de fendas internas / Abstract: Gap formation in composite restorations has been characterized in this dissertation by way of evaluation techniques, modifying factors and the relationship between bond strength of the restorations and the dental structure. In Chapter 1 the objective was to compare the dye staining technique to Scanning Electron Microscopy (SEM) evaluation of gap formation in order to validate the dye technique. Twenty bovine incisors were selected and ground so as to expose a flat dentin area in which two circular cavities were prepared and restored using Filtek 2250 or Filtek Flow. The specimens were polished and replicas were obtained in epoxy resin. Replicas were observed in SEM to determine the percentage of gap fonnation in the margins of the restorations. In dye staining technique, the Caries Detector was applied on each restoration for 5 seconds. Digital images of the stained restorations were analyzed using Image Tool to determine gap percentage. Data were submitted to ANOVA and Pearson's correlation. Filtek Flow showed 35.54% and 33.52% of gap and Filtek 2250 showed 26.68% and 29.11%, when evaluated using SEM and Dye staining technique, respectively. There was no difference between the composites, regardless of the evaluation technique. There was a strong positive correlation (r=0.83) between the results obtained through the tested methods to assess marginal gap. This led to the conclusion that dye staining technique can be reliably employed to evaluate the gap fonnation in composite restorations. Chapter 2 aims at determining the effect of modulated photoactivation methods on gap fonnation of restorations using different composites. Sixty third molars were selected, sectioned (2 fragments) and ground so as to expose a flat enamel area in which a cavity was prepared. The specimens were distributed into twelve groups (n=10), according to the restorative composite (Filtek 2250, Herculite XRV, and Heliomolar) and the photoactivation method (Continuous Light, Soft-Start, Pulse Delay, and Intermittent Light) applied. Marginal adaptation test was conducted in the same way described before (dye staining technique). The specimens were then sectioned in 4 slices, all of which were stained, and the same evaluation procedure used to determine marginal adaptation was employed to evaluate internal gap fonnation. All restorations showed perfect sealing of the enamel outer margins. With regards to internal adaptation, modulated photoactivation methods showed a significant reduction on gap fonnation when compared under continuous light, regardless of the composite. Filtek 2250 showed the best internal adaptation, regardless of the photoactivation method. The interaction between restorative composite and photoactivation method was not significant. The conclusion was that modulated photoactivation methods decrease the internal gap formation of composite restorations and should thus be encouraged on clínical practice, regardless of the type of composite. In Chapter 3, the aim was to evaluate the relationship between bond strength and marginal and internal adaptation of composite restorations photocured by different methods. Bond strength was measured in conical cavities prepared in bovine incisors using push-out test (Instron). Marginal and internal adaptation testswere conducted in the same way as before (dye staining technique). For both tests, cavities were filled with Esthet X resin composite. The specimens were distributed into 5 groups (n= 1 O) according to photoactivation method: G 1 - continuous light; G2 low intensity continuous light; G3 - soft start; G4 - intermittent light; G5 - pulse delay. 14J was the standard energy dose. Data were submitted to ANOVA and Tukey's test. Regarding bond strength, G5 (7.2 MPa) was statistically superior to Gl (4.6 MPa). G2, G3 and G4 showed intermediate mean values, which were not different from each other or from G 1 or G5. Regarding marginal adaptation, there was no statistical difference among the groups. Internal adaptation results (that included dentin substrate) were the opposite of bond strength results. G5 (2.8%) showed a reduction on gap formation when compared to Gl (10.1%). In conclusion, it may be said that the modulated photocuring methods can increase bond strength while decreasing internal gap formation. An opposite relationship was observed regarding push-out bond strength and internal adaptation of composite restorations / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
85

Estudo de parâmetros eletrocardiográficos e de pressão arterial durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em portadores de doença arterial coronária / Investigation of electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia with and without vasoconstrictor in coronary artery disease patients

Neves, Ricardo Simões 12 December 2006 (has links)
Estudamos 62 pacientes, que com teste ergométrico positivo, manifestaram angina estável e estavam sob controle farmacológico. Todos apresentavam cinecoronariografia mostrando obstrução >70% em pelo menos uma das principais artérias coronárias. Objetivamos avaliar parâmetros eletrocardiográficos e de pressão arterial, durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em presença de doença arterial coronária. As idades variaram de 39 a 80, média de 58,7±8,8 anos, sendo 51 (82,3%) homens. Trinta pacientes foram randomizados para receber anestesia local com solução de lidocaína a 2% com adrenalina 1:100.000 e os demais para lidocaína a 2% sem vasoconstritor. Todos os pacientes foram submetidos à monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica por 24 horas, iniciados 2 horas antes do procedimento odontológico. Consideramos 3 períodos de registro: (1) basal - os 60 minutos que antecederam ao procedimento odontológico; (2) procedimento - desde o início da anestesia até o final do procedimento odontológico restaurador; (3) subseqüente completar das 24 horas. A análise de variância com medidas repetidas mostrou que houve elevação significativa da pressão arterial sistólica e diastólica do período basal para o procedimento nos dois grupos estudados (aproximadamente 14mmHg e 5 a 7mmHg) respectivamente, quando analisados separadamente e quando confrontados não apresentaram diferença de comportamento entre si. A freqüência cardíaca não se alterou nos dois grupos estudados. Depressão do segmento ST >1mm ocorreu em 10 (17,9%) pacientes; todos os eventos ocorreram no mínimo 2 horas após o término do procedimento odontológico. Extra - sístoles supra-ventriculares e/ou extra-sístoles ventriculares em número maior do que 10/hora estiveram presentes em 17 (30,4%) pacientes durante as 24 horas e durante o período do procedimento em 7 (12,5%), sendo 4 (13,8%) do grupo que recebeu anestesia sem adrenalina e 3 (11,1%) do grupo que recebeu anestesia com adrenalina e o teste Exato de Fisher não mostrou diferença entre os grupos. Concluímos que não houve diferença em relação ao comportamento de pressão arterial, freqüência cardíaca, evidência de isquemia e arritmias entre os grupos. O uso associado de vasoconstritor mostrou-se, portanto, seguro dentro dos limites do estudo. / We enrolled 62 patients with positive exercise stress test who presented with stable angina and were receiving drug therapy. All had a coronary angiography screening showing >70% obstruction in at least one of the main coronary arteries. The study aimed to compare electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia, both with and without vasoconstrictor, in the presence of coronary artery disease. Ages ranged from 39 to 80, (mean ± SD) 58.7±8.8 years, 51 (82.3%) of them were male. Thirty patients were randomly assigned to receive 2% lidocaine local anesthesia with 1:100,000 epinephrine, the others receiving 2% lidocaine without vasoconstrictor. All the patients underwent ambulatory blood pressure and 24-hour Holter monitoring, beginning two hours ahead of the dental procedure. Recording were made during (1) baseline - 60-minute period before dental procedure began; (2) procedure - from beginning of anesthesia until the end of the procedure; and (3) subsequent 24-hour period. Analysis of variance with repeat measures showed significant diastolic and systolic blood pressure increases from baseline to the period of the procedure, in the two study groups (approximately 14 mm Hg, and 5 to 7 mm Hg, respectively); both in a separate analysis and in a comparative analysis no significant difference between them could be confirmed. Heart rate did not change in neither of the two groups. ST-segment >1 mm depression was detected in 10 (17.9%) patients; all these events occurred at least two hours after the end of the dentistry procedure. Premature supraventricular systoles and/or premature ventricular systoles in a greater number than 10/hour were seen in 17 (30.4%) patients in the 24-hours period after the procedure; during the procedure they occurred in 7 (12.5%) patients, of whom 4 (13.8%) were in the group without, and 3 (11.1%) in the group with vasoconstrictor. The Fisher\'s exact test revealed no difference between the groups. We concluded that there was no difference of blood pressure, heart rate, evidence of ischemia or arrhythmia episodes between the groups. Thus, the associated use of vasoconstrictor proved to be safe within the limits of this study
86

Uticaj endodontske instrumentacije i restaurativnih procedura na biomehaničke karakteristike endodontski lečenih premolara / The influence of endodontic instrumentation and restorative procedures on the biomechanical characteristics of endodontically treated premolars

Maravić Tatjana 15 March 2019 (has links)
<p>Uvod. Usled kompromitovanja strukturnog integriteta, rekonstruktivne procedure na endodontski lečenim zubima moraju se veoma pažljivo isplanirati, pogotovo u specifičnoj grupi zuba kao &scaron;to su premolari. U stomatolo&scaron;koj naučnoj i stručnoj javnosti ne postoji usagla&scaron;en stav o tome koja endodontska instrumentacija i rekonstruktivna procedura primenjena u slučajevima ekstenzivnog gubitka zubne supstance predstavlja metodu izbora sa biomehaničkog aspekta. U okviru prezentovane doktorske disertacije ispitivan je uticaj varijacija u endodontskoj instrumentaciji i restaurativnim procedurama na promene naponskih stanja u zubnim tkivima i rekonstruktivnim materijalima kod premolara sa ekstenzivnim gubitkom zubne strukture. Metode. Osnovni 3D model je kreiran pomoću CT snimaka zdravog drugog gornjeg premolara u SolidWorks programu za modelovanje. Kreirano je 135 različitih modela, u kojima su metodom konačnih elemenata proračunati fon Mizesovi naponi u položaju maksimalne interkuspidacije pod dejstvom sile od 150 N. Statistička analiza je izvr&scaron;ena koristeći Op&scaron;ti linearni model. Rezultati. Indirektne zubne rekonstrukcije imaju povoljniji uticaj na naponska stanja u zubnim tkivima. Ukoliko se koristi direktna restauracija, povoljniji su naponi u dentinu i gleđi ukoliko se redukuje palatinalna kvržca. Upotreba kočića uz ispun snižava napone u zubnim tkivima samo u slučaju MOD kaviteta. Naponi u dentinu su niži pri apikalnom terminusu 0,5 mm i instrumentaciji instrumentima manje veličine (kod modela sa kočićem i indirektnim nadoknadama). Uglavnom procedure koje su povoljne za napone u dentinu, nepovoljne su za napone u zubnoj nadoknadi i obratno. Zaključci. Kod opsežnih MOD kaviteta a samo ukoliko se ne redukuje visina palatinalne kvržice, preporučuje se upotreba kompozitnog kočića. Smanjenje povr&scaron;ine zubnih tkiva u kojima su naponi visoki (iako su najvi&scaron;e vrednosti napona slične), moglo bi da utiče na dugotrajnost endodontski lečenih i rekonstruisanih zuba. Krući rekonstruktivni materijali povoljnije utiču na napone u zubnim tkivima biomehanički kompromitovanih endodontski lečenih zuba. Čini se da je optimalnije, u rekonstruktivnim re&scaron;enjima koja podrazumevaju upotrebu kočića, postaviti apikalni terminus bliže vrhu korena i koristiti instrumente srednje &scaron;irine.</p> / <p>Background. Restoration of an endodontically treated premolar with a wide and deep mesial-occlusal-distal (MOD) cavity is often complex due to biomechanical weakening of the tooth. There are no definitive recommendations on the optimal restoration in these cases. The aim of this study was to determine the effects of different endodontic and restorative procedures on von Mises stress values and distribution in dental tissues and restorative materials using finite element analysis (FEA). Methods. Based on CT scans of an second upper premolar, extracted for orthodontic reasons, 135 3D endodontically treated tooth models were created. Each model was subjected to a summary force of 150 N on the occlusal surface simulating the normal biting pattern and maximal von Mises stresses were calculated. Results. MODP cavity design seems to reduce von Mises stress values in dental tissues and P seems to transfer some of the stresses from dental tissues to the composite filling in the MOD cavity when direct restorations are used. Indirect restorations caused lower stresses within dentin. Apical terminus of 0.5 mm induces lower, while the terminus of 1.5 mm induces the highest stresses in dentin in models restored with direct composite and post. It seems that from the aspect of the tooth tissue, it is more recommended to use smaller endodontic instruments sizes. Conclusions. Stiffer restorative materials cause lower stresses in dentin of an endodontically treated structurally weakened tooth, and if a direct restoration is to be used, palatal cuspal reduction could be beneficial for the longevity of the tooth and the restoration. Further, in a wide and deep MOD cavity, without cuspal reduction, the use of a FRC post is recommended in order to reduce the stresses in the enamel and dentin. Moreover, it seems that it is beneficial for the stresses in the tooth tissue to place the apical terminus closer to the root apex as well as to use smaller size endodontic instruments.</p>
87

Uticaj restaurativnih procedura na biomehaničke karakteristike premolara – analiza realnog trodimenzionalnog modela zuba primenom metode konačnih elemenata / Influence of restorative procedures on biomechanical characteristics of premolar-finite element analysis of threedimensional tooth model

Kantardžić Ivana 31 October 2014 (has links)
<p>Gubitak tvrdih zubnih struktura usled karijesne lezije, traume ili ekstenzivne preparacije dovodi do smanjenja otpornosti preostalih zubnih struktura na dejstvo sila prilikom žvakanja. Osnovni zadatak restaurativne procedure je da se ponovo uspostavi anatomo-morfolo&scaron;ka funkcija zuba i da se preostale zdrave zubne strukture za&scaron;tite od nepovoljnog odgovora na dejstvo sila. Cilj doktorske disertacije bio je da se ispita uticaj različitih restaurativnih procedura na biomehaničke karakteristike premolara sa ekstenzivnim kavitetima. Materijal i metode: Trodimenzionalni model intaktnog drugog gornjeg premolara kreiran je u SolidWorks računarskom programu, na osnovu snimaka ekstrahovanog zuba primenom vi&scaron;eslojnog spiralnog kompjuterizovanog tomografa. Na osnovu ovog modela potom je kreirano ukupno 48 modela, koji su podeljeni u dve grupe: modeli vitalnog premolara sa MOD kavitetom (I grupa) i modeli premolara sa endodontski lečenim kanalom korena sa MOD kavitetom (II grupa). U svakoj grupi ispitivan je uticaj 4 vrste restaurativnog materijala (direktan kompozitni ispun, direktan kompozitni ispun sa smolom modifikovanim glas-jonomer cementom u vidu podloge, indirektan kompozitni ispun, keramički ispun), 3 dizajna preparacije kaviteta (bez skraćivanja kvržica, sa skraćivanjem palatinalne kvržice 2mm, sa skraćivanjem palatinalne i bukalne kvržice 2mm) i 2 &scaron;irine istmusa (1/2 i 2/3 interkuspalnog razmaka). Primenom metode konačnih elemenata proračunate su vrednosti von Mises napona u zubnim strukturama i ispunu za sve modele pri dejstvu statičke sile od 200N. Rezultati: Dizajn preparacije kaviteta je pokazao najveći uticaj na vrednosti von Mises napona u zubnim strukturama. Pri tome, postupak skraćivanja palatinalne, kao i obe kvržice, doprineo je smanjenju vrednosti von Mises napona u gleđi na modelima obe grupe; dok je postupak skraćivanja bukalne i palatinalne kvržice doprineo smanjenju vrednosti von Mises napona u dentinu na modelima vitalnog premolara. U obe grupe, vrsta restaurativnog materijala pokazala je uticaj na vrednosti von Mises napona u gleđi, pri čemu je keramički ispun doveo do pojave napona značajno manjih vrednosti u odnosu na direktan i indirektan kompozitni ispun.Vrsta restaurativnog materijala je uticala i na vrednosti von Mises napona u dentinu, ali samo na modelima vitalnog premolara; pri tome su indirektni kompozitni i keramički ispun podjednako doprineli pojavi napona manjih vrednosti. &Scaron;irina istmusa je uticala na vrednosti von Mises napona u gleđi i dentinu na modelima vitalnog premolara. &Scaron;irina istmusa 1/2 interkuspalnog razmaka dovela je do pojave napona manjih vrednosti u gleđi, dok je &scaron;irina istmusa 2/3 interkuspalnog razmaka dovela do pojave napona manjih vrednosti u dentinu.</p> / <p>Loss of tooth structure from caries, trauma or extensive preparation decreases fracture resistance of tooth. The main goal of restorative procedure is to rebuild lost structures and to protect remaining tooth structures from unfavorable responses from masticatory forces. Aim of thesis was to investigate the influence of different restorative procedures on biomechanical properties of premolar with extensive cavities. Materials and Methods: Three dimensional model of intact maxillary second premolar, based on computerized tomography scan images of extracted tooth, was designed using SolidWorks software. Using this model, 48 models were designed and divided in two groups: models of vital premolars with MOD cavities (group I), and models of premolars with root canal treatment with MOD cavities (group II). In each group use of four restorative materials (direct composite resin restoration, direct composite resin restoration with resin modified glass-ionomer cement as base, indirect composite resin restoration, ceramic restoration), three cavity preparation designs (without cusp coverage, 2mm palatal cusp coverage, 2mm palatal and buccal cusp coverage) and two isthmus width (1/2 and 2/3 intercuspal width) were simulated. After applying static load of 200N, von Mises stresses in enamel, dentin and restoration were calculated using finite element analysis. Results: Cavity preparation design showed the most significant influence on von Mises stress values in tooth structures. Cusp coverage in general decreased stress values in enamel, while palatal and buccal cusp coverage decreased stress values in dentin only in group I. Restorative material affected stress values in enamel, were ceramic restoration contributed to minimal stress values. In dentin, indirect composite resin and ceramic restoration showed no difference in reducing von Mises stress values, but only for models in group I. Cavity isthmus width had influence on stress values in tooth structures only in group I. 1/2 isthmus width decreased stress values in enamel, while 2/3 isthmus width showed same effect in dentin. Conclusion: In order to provide optimal biomechanical characteristics of tooth structures, premolars with MOD cavity should be restored with ceramic overlay covering both palatal and buccal cusp.</p>
88

Estudo de parâmetros eletrocardiográficos e de pressão arterial durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em portadores de doença arterial coronária / Investigation of electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia with and without vasoconstrictor in coronary artery disease patients

Ricardo Simões Neves 12 December 2006 (has links)
Estudamos 62 pacientes, que com teste ergométrico positivo, manifestaram angina estável e estavam sob controle farmacológico. Todos apresentavam cinecoronariografia mostrando obstrução >70% em pelo menos uma das principais artérias coronárias. Objetivamos avaliar parâmetros eletrocardiográficos e de pressão arterial, durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em presença de doença arterial coronária. As idades variaram de 39 a 80, média de 58,7±8,8 anos, sendo 51 (82,3%) homens. Trinta pacientes foram randomizados para receber anestesia local com solução de lidocaína a 2% com adrenalina 1:100.000 e os demais para lidocaína a 2% sem vasoconstritor. Todos os pacientes foram submetidos à monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica por 24 horas, iniciados 2 horas antes do procedimento odontológico. Consideramos 3 períodos de registro: (1) basal - os 60 minutos que antecederam ao procedimento odontológico; (2) procedimento - desde o início da anestesia até o final do procedimento odontológico restaurador; (3) subseqüente completar das 24 horas. A análise de variância com medidas repetidas mostrou que houve elevação significativa da pressão arterial sistólica e diastólica do período basal para o procedimento nos dois grupos estudados (aproximadamente 14mmHg e 5 a 7mmHg) respectivamente, quando analisados separadamente e quando confrontados não apresentaram diferença de comportamento entre si. A freqüência cardíaca não se alterou nos dois grupos estudados. Depressão do segmento ST >1mm ocorreu em 10 (17,9%) pacientes; todos os eventos ocorreram no mínimo 2 horas após o término do procedimento odontológico. Extra - sístoles supra-ventriculares e/ou extra-sístoles ventriculares em número maior do que 10/hora estiveram presentes em 17 (30,4%) pacientes durante as 24 horas e durante o período do procedimento em 7 (12,5%), sendo 4 (13,8%) do grupo que recebeu anestesia sem adrenalina e 3 (11,1%) do grupo que recebeu anestesia com adrenalina e o teste Exato de Fisher não mostrou diferença entre os grupos. Concluímos que não houve diferença em relação ao comportamento de pressão arterial, freqüência cardíaca, evidência de isquemia e arritmias entre os grupos. O uso associado de vasoconstritor mostrou-se, portanto, seguro dentro dos limites do estudo. / We enrolled 62 patients with positive exercise stress test who presented with stable angina and were receiving drug therapy. All had a coronary angiography screening showing >70% obstruction in at least one of the main coronary arteries. The study aimed to compare electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia, both with and without vasoconstrictor, in the presence of coronary artery disease. Ages ranged from 39 to 80, (mean ± SD) 58.7±8.8 years, 51 (82.3%) of them were male. Thirty patients were randomly assigned to receive 2% lidocaine local anesthesia with 1:100,000 epinephrine, the others receiving 2% lidocaine without vasoconstrictor. All the patients underwent ambulatory blood pressure and 24-hour Holter monitoring, beginning two hours ahead of the dental procedure. Recording were made during (1) baseline - 60-minute period before dental procedure began; (2) procedure - from beginning of anesthesia until the end of the procedure; and (3) subsequent 24-hour period. Analysis of variance with repeat measures showed significant diastolic and systolic blood pressure increases from baseline to the period of the procedure, in the two study groups (approximately 14 mm Hg, and 5 to 7 mm Hg, respectively); both in a separate analysis and in a comparative analysis no significant difference between them could be confirmed. Heart rate did not change in neither of the two groups. ST-segment >1 mm depression was detected in 10 (17.9%) patients; all these events occurred at least two hours after the end of the dentistry procedure. Premature supraventricular systoles and/or premature ventricular systoles in a greater number than 10/hour were seen in 17 (30.4%) patients in the 24-hours period after the procedure; during the procedure they occurred in 7 (12.5%) patients, of whom 4 (13.8%) were in the group without, and 3 (11.1%) in the group with vasoconstrictor. The Fisher\'s exact test revealed no difference between the groups. We concluded that there was no difference of blood pressure, heart rate, evidence of ischemia or arrhythmia episodes between the groups. Thus, the associated use of vasoconstrictor proved to be safe within the limits of this study
89

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Neves, Itamara Lucia Itagiba 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.
90

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Itamara Lucia Itagiba Neves 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.

Page generated in 0.3616 seconds