1 |
Avaliação do efeito da afiação com diferentes técnicas sobre o ângulo de corte de curetas de Gracey /Andrade Acevedo, Roberto Antonio. January 2003 (has links)
Orientador: José Eduardo Cezar Sampaio / Banca: Silvana Regina Perez Orrico / Banca: Joni Augusto Cirelli / Banca: Enilson Antonio Sallum / Banca: Gibson Luiz Pilatti / Resumo: O presente trabalho teve por objetivo avaliar em fotomicrografias obtidas em microscópio eletrônico de varredura (MEV) o ângulo de corte de curetas de Gracey 5-6 em três níveis: afiação de fábrica, após ficarem sem corte e após serem reafiadas utilizando nove diferentes técnicas padronizadas de afiação: 1- face lateral da cureta contra a pedra Arkansas plana; 2- face coronal e posteriormente a lateral contra a pedra Arkansas plana; 3- pedra de Arkansas plana contra a face lateral da cureta; 4- cone de óxido de alumínio a baixa rotação contra a face coronal e em seguida a face lateral da cureta; 5- face lateral da cureta com pedra Arkansas 299; 6- face lateral da cureta com o aparelho padronizador Hu-Friedy; 7- face coronal da cureta com ponta de videa; 8- face coronal da cureta com ponta de videa e em seguida a face lateral com pedra de Arkansas plana; 9- afiação da face coronal com ponta de videa e em seguida pó abrasivo e roda de feltro rotatória na face lateral da cureta. Foram tomadas fotomicrografias (350X) do ângulo de corte e posteriormente avaliadas por um examinador calibrado através do índice do ângulo de corte. A analise estatística de Kruskal Wallis e comparações múltiplas mostraram que as técnicas 1 e 2 foram as melhores técnicas de afiação seguidas das técnicas 6, 5 e 8. As piores técnicas foram a 7, 9, 4, 0 e 3. A reafiação da face coronal das curetas produziu a formação de projeções metálicas não funcionais no ângulo de corte e finalmente não houve diferenças entre a afiação do extremo par e ímpar dos instrumentos em nenhuma das técnicas de afiação utilizadas. / Abstract: A micrographs obtained by a scanning electron microscope (SEM) were used to evaluated the gracey 5-6 cutting edges as the come from manufacture, after they had been dull and after they were resharpened by several standard techniques: 1- lateral surface over a flat Arkansas sharp stone; 2- coronal surface and the a lateral surface over a flat Arkansas sharp stone; 3- lateral surface by passing a flat Arkansas sharp stone; 4- rotatory aluminum oxide stone over a coronal surface and then over a lateral face; 5- lateral surface by passing an Arkansas 299 stone; 6- lateral surface on Hu-Friedy sharp divice; 7- coronal surface by a Whittler Neivert Device; 8- coronal face by a Whittler Neivert Device and the a lateral surface over a flat Arkansas sharp stone; 9- coronal surface with a Whittler Neivert Device and a rotating, impregnated, felt wheel on the lateral surface. The cutting edges was blindly evaluated on micrographs (X350) by one calibrated examiner (cutting angle index). A statistical analysis showed that techniques 1 and 2 were the best ones followed by a 6, 5 and 8 techniques. The worst techniques were a 7, 9, 4, 0 and 3. Resharpened on the coronal face of curettes generated a non functional wire edges on the cutting edge angle and there were not differences between the paired and unpaired extreme of the instruments resharpened. / Doutor
|
2 |
Ação do laser de Er:YAG e de diodo na adesão de elementos sanguíneos e na morfologia de superfícies radiculares irradiadas. Estudo através de microscopia eletrônica de varredura /Theodoro, Letícia Helena. January 2003 (has links)
Orientador: José Eduardo Cezar Sampaio / Banca: Rosemary Adriana Chiérici Marcantonio / Banca: Álvaro Francisco Bosco / Banca: Denise Maria Zezel / Banca: Antônio Wilson Sallum / Resumo: O objetivo deste estudo foi avaliar in vitro, a adesão de elementos sanguíneos sobre superfícies radiculares irradiadas com laser de Er:YAG e de Diodo, e a ação destes sobre as superfícies radiculares. Foram obtidas 120 amostras de dentes humanos extraídos por doença periodontal, que foram previamente raspados e aplainados com instrumentos manuais, sendo a seguir divididas aleatoriamente em 6 grupos com 20 amostras cada. O G1 (controle)- não recebeu nenhum tratamento; o G2- recebeu aplicação tópica de EDTA 24%; G3- foi irradiado com laser de Er:YAG com 7,6 J/cm2; o G4- irradiado com laser de Er:YAG com 12,9 J/cm 2; o G5 -irradiado com laser de Diodo com 90 J/cm2 e o G6 - foi irradiado com laser de Diodo com 108 J/cm2. Após a realização dos tratamentos, em 10 amostras de cada grupo foi depositado imediatamente a sua punção, tecido sanguíneo originado da vascularização periférica de humano, sendo que 10 amostras não receberam tal tratamento. Após processamento laboratorial as amostras foram analisadas através de microscopia eletrônica de varredura. As fotomicrografias obtidas foram avaliadas através de dois índices: adesão de elementos sanguineos e de morfologia da superfície radicular e estatisticamente analisadas (Kruskall Wallis e Mann-Whitney). Os resultados demonstraram que em relação a adesão de elementos sanguíneos não houve diferenças estatisticamente significante entre o grupo controle e os tratados com o laser de Er:YAG (p=0,7733 e 0,7831) ; O G5 mostrou-se menos efetivo que o controle na adesão de elementos sanguíneos ( p=0,0305 ) e o G2 foi o menos efetivo de todos na adesão. Com relação a morfologia da superfície radicular houve diferenças significantes entre o controle e os grupos do laser de Er:YAG (p= 0,0001) e entre o G5 do Diodo (0,0259); entre o EDTA e os grupos do laser de Er:YAG (p=0,0150 ) e entre o... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to evaluate in vitro the adhesion of blood components on root surfaces irradiated with Er:YAG and Diode lasers and these lasers effects on root surfaces. It was obtained 120 samples of human teeth extracted by periodontal disease. They were planed and scaled previously with manual instruments and randomly divided into 06 groups of 20 samples each. The groups were treated according to the following procedures: G1 (Control Group) -received no treatment; G2- had a topical application of EDTA 24%; G3- was irradiated with Er:YAG laser (7,6 J/cmø); G4 - was irradiated with Er:YAG laser (12,9 J/cmø); G5 - was irradiated with Diode laser (90 J/cmø) and G6 was irradiated with Diode laser (108 J/cmø). After these treatments were conducted, 10 samples of each group received a stippler, a blood tissue originated from peripheral vascularization, and the reminiscent samples did not receive such treatment. After laboratorial analysis the samples were analyzed through a scanning electronic microscopy. The photomicrographs obtained were evaluated according to adhesion of blood components and morphology of root surface; and statistically analyzed (Kruskall Wallis and Mann-Whitney). With relation to the adhesion of blood components, the results have shown that there were no significant differences between the Control Group and the groups treated with Er:YAG laser (p=0,7733 and 0,7831); G5 was less effective than the Control Group in adhesion of blood components (p=0,0305) and G2 was the least effective of all groups in this case. With relation to the morphology of root surface there were significant differences among the Control Group, the Er:YAG laser groups (p=0,0001) and the Diode laser G5 (p=0,0259); between the EDTA and the Er:YAG laser groups (p=0,0150) and also between the Diode laser G6 and the Er:YAG laser groups (p=0,0032)... (Complete abstract, click electronic address below). / Doutor
|
3 |
Efeito do condicionamento radicular com ácido cítrico, citrato de sódio, EDTA e tetraciclina na adesão de elementos sanguíneos. Estudo por meio de microscopia eletrônica de varredura. -Leite, Fábio Renato Manzolli. January 2006 (has links)
Resumo: A raspagem gera smear layer que contém microrganismos e toxinas, podendo interferir no reparo periodontal. Por esse motivo, diferentes substâncias têm sido empregadas para remover esta camada e expor fibras colágenas da superfície dental. A adesão de elementos sangüíneos a superfícies radiculares desmineralizadas e a estabilização do colágeno pelas fibras colágenas são de extrema importância no sucesso da cirurgia periodontal. O objetivo deste estudo foi avaliar os diferentes padrões de adsorção e adesão de elementos sangüíneos a superfícies radiculares quimicamente condicionadas. Setenta e cinco dentes foram raspados, eqüitativamente divididos em 5 grupos: irrigação com água destilada (controle), aplicação de solução de ácido cítrico a 25%, solução de citrato de sódio a 30%, gel de EDTA a 24% e solução de cloridrato de tetraciclina a 50 mg/mL. Metade da superfície condicionada foi exposta a sangue fresco e preparada para microscopia eletrônica de varredura. As superfícies radiculares raspadas e condicionadas com EDTA e ácido cítrico apresentaram os melhores resultados em relação ao grupo controle. O ácido cítrico também se mostrou mais efetivo na remoção de smear layer e na adesão de elementos sangüíneos do que o cloridrato de tetraciclina e o citrato de sódio. Além disso, a relação entre exposição de fibras colágenas e adesão de elementos sangüíneos foi positiva. Dessa forma, o emprego de EDTA e ácido cítrico sobre a superfície radicular aumentam a adsorção e adesão de células sangüíneas e a estabilização da rede de fibrina. / Abstract: Root scaling generates a smear layer which contains microorganisms and toxins that could interfere in periodontal healing. For this reason, different substances have been used to remove it and to expose collagen fibers from tooth surface. Blood elements adhesion to demineralized roots and clot stabilization by collagen fibers are extremely important for the success of periodontal surgery. The aim of this study was to evaluate the different patterns of blood elements adsorption and adhesion to root surfaces chemically conditioned. Seventy five teeth were planed and equitably divided into five groups: irrigation with distilled water (control), application of a 25% citric acid solution, 30% sodium citrate solution, 24% EDTA gel and 50 mg/mL tetracycline hydrochloride. Half of the conditioned surface was exposed to fresh blood and prepared for scanning electron microscopy. Planed root surfaces and conditioned with EDTA and citric acid showed better results when compared to control group. Citric acid was more effective on smear layer removal and blood elements adhesion to root surface than tetracycline and sodium citrate. Also, the relationship between collagen fibers exposure and blood elements adhesion was positive. This way, EDTA and citric acid employment on root surface improve blood element adsorption and adhesion to root surface and fibrin network stabilization. / Orientador: José Eduardo Cezar Sampaio / Coorientador: Letícia Helena Theodoro / Banca: Carlos Rossa Júnior / Banca: Enilson Antonio Sallum / Mestre
|
Page generated in 0.1086 seconds