• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação das alterações tegumentares produzidas pelo aparelho de Herbst em indivíduos classe II divisão 1º, tratados em diferentes estágios de crescimento

Pereira, Ana Patricia de Sousa [UNESP] 18 May 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-18Bitstream added on 2014-06-13T19:56:53Z : No. of bitstreams: 1 pereira_aps_me_arafo.pdf: 2580064 bytes, checksum: a67d152abefb1c415091c79bd9acff7a (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Esta pesquisa teve como objetivo realizar estudo cefalométrico das alterações tegumentares no tratamento da má oclusão de Classe II com o aparelho de Herbst. No primeiro estudo, avaliou-se as alterações tegumentares em pacientes com má oclusão de Classe II divisão 1, tratados com o aparelho de Herbst, após o pico de crescimento pubertário. A amostra foi composta por 71 indivíduos, sendo um grupo tratado (n=32) com o aparelho de Herbst e outro grupo controle canadense (n=39) com características iniciais semelhantes à do grupo tratado, acompanhado sem tratamento. Utilizou-se o teste t de Student para análise estatística. Concluiu-se que as alterações tegumentares foram maiores na região de lábio inferior e ângulo mentolabial e que a convexidade da face foi reduzida de forma significativa, melhorando a estética facial. No segundo estudo avaliou-se as mudanças tegumentares promovidas pelo aparelho de Herbst, em dois grupos distintos de indivíduos com má oclusão de Classe II divisão 1: Grupo 1: 20 indivíduos com idade inicial de 8 a 10 anos, tratados com o aparelho de Herbst por 7 meses, antes do pico de crescimento pubertário, e, Grupo 2: 24 indivíduos com idade inicial de 13 a 17 anos, tratados por 8 meses, após o pico de crescimento pubertário. Utilizou-se o teste t de Student para análise estatística. O tratamento não promoveu interferência na maxila e lábio superior, independente da fase de crescimento facial. Os incisivos e lábio inferior foram protruídos nos dois grupos e o pogônio tegumentar exibiu projeção significante no grupo pré-pico. Ocorreu diminuição da convexidade facial e esquelética em ambos os grupos e de forma mais proeminentes no grupo pré-pico / This research aims to perform a cephalometric study of soft tissue profile changes in the treatment of Class II division 1 malocclusion with the Herbst appliance. In the first study, the soft tissue changes in patients with Class II division 1 malocclusion, treated with the Herbst appliance, after the pubertal growth peak were evaluated. The sample consisted of 71 individuals, Class II malocclusion division 1 after the pubertal growth peak, divided into two groups: one group treated (n=32) with the Herbst appliance, and the canadian control group (n=39) followed without treatment. Statistical analysis was tested with Student’s t test. . It was demonstrated that changes in soft tissue profile were pronounced in the region of the lower lip and mentolabial angle. The convexity of soft tissue profile was reduced significantly, improving facial aesthetics. In the second study, soft tissue changes promoted by the Herbst appliance in two distinct groups of patients with Class II division 1 malocclusion were evaluated; Group 1: 20 subjects, initial ages between 8 and 10 years treated with the Herbst appliance for 7 months before the pubertal growth peak (pre-peak); Group 2: 24 subjects with initial ages between 13 and 17 years treated with the same unit for eight months after the pubertal growth peak (post-peak). Statistical analysis was tested with Student’s t test. No interference in the maxilla and upper lip position was observed in both groups. The lower incisors proclined and the lower lip protruded in both groups and the projection of soft tissue pogonion in pre-peak group was significantly. There was a reduction of facial convexity with the most prominent changes in the pre-peak group
2

Análise das medidas verticais em dentes humanos, mensurados in vitro e nas radiografias panorâmicas

Bissoli, Cleber Frigi [UNESP] 01 July 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-07-01Bitstream added on 2014-06-13T18:07:38Z : No. of bitstreams: 1 bissoli_cf_me_sjc.pdf: 1658392 bytes, checksum: 87521fc116b48dbe7d8b1a4b112dee4e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste trabalho é analisar e verificar as medidas verticais de dentes humanos in vitro por meio de radiografias panorâmicas. O estudo foi baseado na montagem de uma boca com 28 dentes em um manequim de borracha, sendo utilizado para a realização das radiografias dois aparelhos ortopantomográficos (Rotograph plus e Panoura-10). O manequim, com o auxílio de suportes de madeira, foi radiografado com o plano oclusal paralelo ao horizontal, e também com seu plano oclusal à +5 graus e à -5 graus em relação ao plano horizontal. Os resultados obtidos indicaram que para a região de incisivos para o aparelho Rotograph plus a ampliação foi de 18,97% na maxila e 17,91% na mandíbula; para a região de pré-molares foi de 16,38% na maxila e 16,30% na mandíbula; e para a região de molares foi de 14,90% na maxila e 14,24% na mandíbula. Já para o aparelho Panoura-10 foi na região de incisivos 19,70% na maxila e 19,31% na mandíbula, na região de pré-molares 18,49% na maxila e 17,88% na mandíbula e para molares 16,66% na maxila e 16,17% na mandíbula. Conclui-se que houve ampliações diferentes nas regiões anatômicas estudadas. Posteriormente foi feito o teste estatístico ANOVA, e não houve diferenças estatisticamente significantes entre as inclinações de +5 graus e -5 graus em relação ao plano oclusal paralelo ao horizontal nos dois aparelhos (p>0,05). Também foi concluído que o aparelho Panoura-10 obteve 18,03% de ampliação vertical geral média e que o Rotograph plus obteve 16,45% de ampliação vertical geral média. / The aim of this work is to analyze and to verify the vertical measurements of the human teeth in vitro by panoramic radiographs. The study was based in set up of 28 teeth in rubber manikin. The radiographs were made with two orthopantomographs (Rotograph plus and Panoura - 10). The manikin with wood supports was radiographic with oclusal plane parallel to horizontal plane and oclusal plane 5 degrees positive and 5 degrees negative to horizontal plane. The results has showed that in incisors region, in Rotograph plus, has enlarged 18,97 % for the maxilla and 17,91% for the mandible; in bicuspid region, 16,38% for the maxilla and 16,30%for the mandible; and molar region, 14,90% for the maxilla and 14,24% for the mandible. The Panoura - 10 has enlarged in incisor region, 19,70% for the maxilla and 19,31% for the mandible, mandible, in bicuspid region, 18,49 % for the maxilla and 17,88 % for the mandible and molar region 16,66 % for the maxilla and 16,17 % for the mandible. The conclusions were that different enlargements in anatomic regions studied occurred. The ANOVA test has known that significance statistical differences between the inclinations of +5 degrees and -5 degrees and oclusal plane parallel the horizontal plane in both (p>0,05) didn t happen. The Panoura - 10 has enlarged 18,03% in total vertical average and the Rotograph plus has enlarged, 16,45 % in total vertical average.
3

Subtração digital radiográfica: identificação precoce de perdas minerais em esmalte

Dotto, Gustavo Nogara [UNESP] 30 June 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-06-30Bitstream added on 2014-06-13T19:38:20Z : No. of bitstreams: 1 dotto_gn_me_sjc.pdf: 1763625 bytes, checksum: f58c55befeddf132e0118ae4623007eb (MD5) / Neste estudo in vitro, avaliou-se a progressão da perda mineral causada pela aplicação de ácido clorídrico a 18% em esmalte proximal de dentes pré-molares humanos, utilizando imagens radiográficas digitais diretas e também a técnica de subtração digital de imagens, por meio da comparação dos valores de densidade óptica nas ROI antes e após aplicação ácida. Foram utilizados um aparelho radiográfico Gendex DC765 e o sistema Visualix Gx-S HDI para radiografia digital direta. Os resultados foram obtidos utilizando três tempos de exposição aos raios X (0.025, 0.050, 0.100s) com e sem a interposição de um simulador para tecidos moles. Variação no tempo de exposição aos raios X e uso de simulador tem influência sobre os valores de densidade óptica das imagens originais (p=0,00), o mesmo não ocorrendo para as imagens subtraídas. Os valores de densidade óptica também diferiram entre as ROI com e sem aplicação ácida (p=0,00) em ambas imagens originais e subtraídas. A variação na densidade óptica das ROI possibilitou avaliar a progressão da perda mineral em esmalte proximal, tanto nas imagens originais quanto nas subtraídas; a técnica de subtração digital da imagem radiográfica permitiu a visualização da progressão da perda mineral em esmalte proximal. / In this in vitro study, it was evaluated the mineral loss progression caused by the application of 18% hydrochloric acid in human premolars proximal enamel, using direct digital radiographic images and the digital subtraction radiography, comparing the optical density before an after acid application. It was used a Gendex DC765 X-ray generator and the Visualix Gx-S HDI digital X-ray. The results were obtained using three different X-rays exposures (0.175, 0.35, 0.7mAs) with and without the interference of a oral tissues simulator. The use of different X-ray exposure and interference of a oral tissues simulator had influenced on the optical density values for the original images (p=0,00), the same didn't occur for the digital subtracted images. The optical density values also differed among the ROI with and without acid application (p=0,00) in both original and subtracted images. The ROI optical density variation facilitated the evaluation of the proximal enamel mineral loss progression, in both original and subtracted images; the digital subtraction radiography allowed the visualization of the proximal enamel mineral loss progression.
4

Manipulação em imagens radiográficas odontológicas digitais e digitalizadas e a certificação digital

Soares, Milton Gonçalves [UNESP] 04 July 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-07-04Bitstream added on 2014-06-13T18:38:56Z : No. of bitstreams: 1 soares_mg_me_sjc.pdf: 2376388 bytes, checksum: a2e6034be2de354eb51443c61b717f1c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo neste trabalho foi verificar a possibilidade de manipulação em imagens radiográficas digitais e digitalizadas, avaliar a capacidade dos especialistas em Radiologia Odontológica em detectá-las, avaliar o conhecimento dos mesmos sobre a certificação digital e seus aspectos legais, verificando a segurança do sistema. Para tanto, foram utilizadas 15 radiografias, dez digitalizadas e cinco digitais, sendo 12 manipuladas, nas quais foram feitas manipulações digitais simulando várias condições, por exemplo, inserção e remoção de lesões, reabsorção óssea e radicular. Para isso foi utilizado o programa gráfico Adobe Photoshop versão 7.0 (Adobe systems incorporated,USA). Após as manipulações as imagens foram apresentadas no programa PowerPoint e posteriormente avaliadas por 20 examinadores, os quais responderam questionários referentes às manipulações das imagens radiográficas e a certificação digital, a qual realizamos testes para verificar sua segurança. Os resultados obtidos com a aplicação do Teste Z, para análise estatística das avaliações das imagens e para as respostas sobre certificação digital, mostram que houve baixo percentual de acerto por parte dos examinadores nas avaliações das imagens, apresentando resultado estatístico significante ao nível de 5%. Para as respostas sobre certificação digital houve diferença estatisticamente significante para duas perguntas, isso demonstra que os profissionais não têm conhecimento suficiente para utilizar esse sistema de segurança digital. Portanto, concluímos que, é possível manipular imagens radiográficas digitais e digitalizadas sem que os especialistas em Radiologia Odontológica detectem-nas e que os mesmos têm pouco conhecimento sobre certificação digital, seus aspectos legais e sua segurança. / The aims of the present research paper are to evaluate the possibility of manipulation on digital and digitalized radiographic images, to assess the ability of Oral and Maxillofacial Radiologists to detect these manipulations, and to evaluate their knowledge about the Digital Certification, its forensic aspects and its security. From a total of 15 radiographies, 10 digitalized and 5 digital, 12 had many conditions digitally added, such as lesions, bone resorption and dental resorption. The manipulations were done on Adobe Photoshop v. 7.0 (Adobe systems incorporated, USA). The images were then inserted as PowerPoint presentations and submitted to the evaluation of 20 Oral and Maxillofacial Radiologists, who answered a questionnaire about the manipulations and the Digital Certification. This system was also tested in order to verify its security. The Z-Test was used to analyze the answers about the manipulation of the images evaluation and the answers about the Digital Certification. The results demonstrated a low percentage of right answers about the manipulation of the images. This result was statistically significant at 5% level of confidence. On the other hand, there was no statistically significant diferences for the answers about the Digital Certification, although the results showed that the professionals do not have enough knowledge to use this security system. We concluded therefore that it is possible to manipulate digital and digitalized images with enough quality to avoid the Oral and Maxillofacial Radiologists detecting the modifications. We also concluded that the professionals have little knowledge about the Digital Certification, its forensic aspects and its security.

Page generated in 0.0975 seconds