Spelling suggestions: "subject:"dentin"" "subject:"cotentin""
51 |
Avaliação in vitro da energia livre de superfície da dentina após tratamento com trimetafosfato de sódio associado ou não ao fluoreto, exposto ou não ao cálcio. / In vitro evaluation of free surface energy of dentin after treatment with sodium trimetaphosphate associated or not to fluoride, exposed or not to calcium.Oliveira, Lenara Queiroz Chaves [UNESP] 02 February 2018 (has links)
Submitted by Lenara Queiroz Chaves Oliveira null (lenarachaves@hotmail.com) on 2018-03-20T22:55:03Z
No. of bitstreams: 1
Dissertação 20-03-18.pdf: 1692025 bytes, checksum: 45efefd11a0f384a53de99e576eeb71c (MD5) / Approved for entry into archive by Ana Paula Rimoli de Oliveira null (anapaula@foa.unesp.br) on 2018-03-21T13:51:16Z (GMT) No. of bitstreams: 1
oliveira_lqc_me_araca_int.pdf: 1692025 bytes, checksum: 45efefd11a0f384a53de99e576eeb71c (MD5) / Made available in DSpace on 2018-03-21T13:51:16Z (GMT). No. of bitstreams: 1
oliveira_lqc_me_araca_int.pdf: 1692025 bytes, checksum: 45efefd11a0f384a53de99e576eeb71c (MD5)
Previous issue date: 2018-02-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro a energia livre de superfície (γS) da dentina após tratamento com trimetafosfato de sódio (TMP) associado ou não ao fluoreto (F), exposto ou não ao cálcio (Ca), bem como, a adsorção de TMP, F e Ca na dentina. Blocos de dentina bovino (4 mm x 4 mm, n=12 blocos/grupo) foram tratados por meio da imersão em soluções contendo TMP nas concentrações: 0%; 1%; 3% e 9% seguido da aplicação ou não de Ca. Estas concentrações de TMP foram associadas ou não ao F na concentração de 1100 ppm F. Foram determinadas as concentrações de F, Ca e TMP nas soluções antes e após o tratamento para calcular a adsorção destes a dentina. Para analisar a energia livre de superfície (γS) da dentina, os componentes apolar (γSLW) e polar (γSAB) eram determinados após os tratamentos por meio da medida do ângulo de contato. Os dados foram submetidos à análise de variância a dois critérios seguidos pelo teste Student-Newman-Keuls (p<0,05). O TMP reduziu a γS da dentina e aumentou os sítios doadores de elétrons (γS). Houve correlação positiva entre a adsorção de TMP e os valores de γS (Pearson’s r=0,801; p<0,001). Maiores valores de γS levou a maior adsorção de Ca (p<0,001). A associação F/TMP não alterou a γS e γSLW e reduziu os valores de γS, entretanto houve maior adsorção de Ca. Houve correlação positiva entre a adsorção de TMP e F (Pearson’s r=0,871; p<0,001). Concluiu-se que o TMP aumentou a γS e adsorção de Ca, e reduziu a γS. A associação com o F aumentou a adsorção de TMP sem aumentar a γS, porém houve maior adsorção de Ca. / The objective of this study was to evaluate in vitro the free surface energy (γS) of dentin after treatment with sodium trimetaphosphate (TMP) associated or not to fluoride (F), exposed or not to calcium (Ca), as well as the adsorption of TMP, F and Ca in dentin. Bovine dentin blocks (4 mm x 4 mm, n=12 blocks/group) were treated by immersion in solutions containing TMP at concentrations: 0%; 1%; 3% and 9% followed or not by the application of Ca. These concentrations of TMP were or not associated with F at the concentration of 1100 ppm F. Concentrations of F, Ca and TMP were determined in the solutions before and after the treatment to calculate the adsorption to the dentin. To analyze the free surface energy (γS) of the dentin, the apolar (γSLW) and polar (γSAB) components were determined after the treatments by means of the contact angle measurement. Data were submitted to analysis of variance at two criteria followed by the Student-Newman-Keuls test (p<0.05). The results showed that TMP reduces γS of dentin and increases electron donor sites (γS). There was a positive correlation between the adsorption of TMP and the values of γS, (Pearson's r=0.801; p<0.001). Higher values of γS led to higher adsorption of Ca (p<0.001). The F/TMP association did not change γS and γSLW and reduced the values of γS,, but the adsorption of calcium was higher. There was a positive correlation between the adsorption of TMP and F (Pearson's r=0.871, p<0.001). TMP increased γS and Ca adsorption, and reduced as γS . The association with F increased the adsorption of TMP without increasing γS, however there was higher adsorption of Ca.
|
52 |
Estudo comparativo de temperatura e morfologia do esmalte e dentina preparados com laser de Er, Cr: YSGG ou sono-abrasão com pontas CVD: Estudo in vitroARAUJO, MATHEUS S. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:16Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:02Z (GMT). No. of bitstreams: 1
10827.pdf: 7513346 bytes, checksum: c9f7e38c15b5625e4417859ce83b1118 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo
|
53 |
Evaluation of acidic functional monomers with spacer chains with different hydrophilicities and lengths = Avaliação de monômeros funcionais ácidos com cadeias espaçadoras de diferentes hidrofilias e comprimentos / Avaliação de monômeros funcionais ácidos com cadeias espaçadoras de diferentes hidrofilias e comprimentosFeitosa, Victor Pinheiro, 1987- 23 August 2018 (has links)
Orientadores: Américo Bortolazzo Correr, Mário Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T10:38:23Z (GMT). No. of bitstreams: 1
Feitosa_VictorPinheiro_D.pdf: 2456135 bytes, checksum: c15250b4b741e036f66121da12d96a07 (MD5)
Previous issue date: 2013 / Resumo: O objetivo neste estudo foi avaliar o efeito da cadeia espaçadora (comprimento e polaridade) de cinco monômeros funcionais fosfatados, MEP (dois carbonos), MDP (dez carbonos), MDDP (doze carbonos), MTEP (cadeia mais hidrófila) e CAP-P (cadeia com hidrofilia intermediária) sobre a união química com dentina e cálcio, as propriedades físico-químicas e a adesão à dentina. Este estudo foi separado em 3 Capítulos. No Capítulo 1 foi verificada a influência da cadeia espaçadora de monômeros funcionais no grau de conversão, resistência coesiva, sorção de água e molhamento de adesivos experimentais de passo único. A fotoativação em todos os capítulos foi realizada com o aparelhos de luz de lâmpada halógena com irradiância mínima de 600mW/cm². Todos os dados foram submetidos à análise de variância de um fator e teste de Tukey (?=0.05). Os resultados mostraram que os diferentes monômeros promoveram grau de conversão semelhante quando adicionado em porcentagens molares iguais. Entretanto, a resistência coesiva foi diferente, com maiores valores para monômeros capazes de propiciar interações intermoleculares (MTEP, MDP e MDDP). A sorção de água e o molhamento sobre superfícies de dentina foram maiores utilizando os monômeros mais hidrófilos (polares). No Capítulo 2, o objetivo foi avaliar a interação química dos monômeros funcionais com cálcio e dentina. Foi analisada a formação de sais monômero-cálcio através da concentração de cálcio livre (Ca2+) em espectroscopia de absorção atômica (AAS), a interação de soluções aquosas dos monômeros com fatias de dentina antes e após a lavagem com água e etanol através de espectroscopia infravermelho transformada de Fourier (FTIR) e a presença dos monômeros sobre as fatias de dentina também foi observada em microscopia eletrônica de varredura. Os resultados mostraram que a união iônica com cálcio é maior com monômeros contendo cadeias espaçadoras longas e menos polares (MDP e MDDP). A estabilidade dessas ligações frente à lavagem foi afetada somente para o monômero com cadeias curta. A hidrofilia da cadeia não afetou a estabilidade da união química. No Capítulo 3, o objetivo foi avaliar a formação da ligação entre monômeros e cálcio e adesão de sistemas adesivos de passo único usando os monômeros estudados. Foi analisada a resistência de união à microtração após 24 horas e um ano de armazenagem em água, a absorbância de cálcio livre em AAS, a micropermeabilidade e a nanoinfiltração dos adesivos. Os resultados mostraram que a resistência de união inicial e a formação de ligações com cálcio foram menores para os monômeros com cadeias espaçadoras curtas e polares. A resistência de união foi reduzida após armazenagem somente para o monômero com cadeia espaçadora mais hidrófila (MTEP), provavelmente devido a maior micropermeabilidade e sorção de água. Houve pouca nanoinfiltração somente para monômeros com cadeias longas e hidrófobas. Como conclusão, observou-se que cadeias espaçadoras mais hidrófilas e mais curtas prejudicam a união química, a adesão e as propriedades físico-químicas dos monômeros ácidos funcionais / Abstract: The aim of this study was to evaluate the effects of spacer chain (length and polarity) of five phosphoric functional monomers, MEP (two carbons), MDP (ten carbons), MDDP (twelve carbons), MTEP (more hydrophilic spacer chain) and CAP-P (intermediate hydrophilicity spacer). It was assessed the chemical bonding with dentin and calcium, the physicochemical properties of one-step self-etch adhesives and the adhesion to dentin. This investigation was separated in 3 chapters. Chapter 1 verified the influence of spacer chain of functional monomers on the degree of conversion, ultimate tensile strength (UTS), water sorption and wettability of experimental all-in-one adhesives. Light-activation in all chapters was undertaken using halogen-lamp with minimal irradiance of 600mW/cm². All data were submitted to one-way ANOVA and Tukey's test (p<0.05). The outcomes showed that different monomers promote similar degree of conversion when added in same molar percentage. Nevertheless, their UTS were distinct, with high values for monomers able to promote intermolecular interactions. The water sorption and dentin wettability were greater with more hydrophilic (polar) monomers. In chapter 2, the purpose was to assess the chemical interaction of studied functional monomers with calcium and dentin. It was analyzed the formation of monomer-calcium salts through evaluation of free-calcium (Ca2+) in atomic absorption spectroscopy (AAS), the interaction of aqueous monomer-containing solutions with dentin slabs before and after rinsing with water and ethanol by means of Fourier-transform infrared spectroscopy (FTIR) and the presence of monomers onto the dentin slabs was imaged in scanning electron microscopy. The results displayed better ionic bond with calcium with monomers based on long and less polar spacer chains. The stability of such linkages was affected only for the monomer with short spacer chain. The hydrophilicity of spacer chain did not affect the stability of the chemical bond. In chapter 3, the aim was to evaluate the formation of bonds between monomers and calcium as well as the bonding performance of all-in-one adhesives using the investigated monomers. It was analyzed the microtensile bond strength after 24h and one year of water storage, the AAS absorbance of free-calcium, the micropermeability and the nanoleakage of adhesives. The outcomes showed that initial bond strength and formation of linkages with calcium were lower for monomers with short and polar spacer chains. The bond strength was reduced after aging only for the monomer with highly hydrophilic spacer chain, likely due to higher micropermeability. There was little nanoleakage only for monomers with long and hydrophobic spacer chains. As conclusion, it was observed that more hydrophilic and short spacer chains jeopardize the chemical bonding, the adhesion and the physicochemical properties of acidic functional monomers / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
|
54 |
Influência da limpeza mecânica com e sem o uso do microscópio operatório na resistência adesiva intrarradicular / Influence of mechanical cleaning with and without the use of the operating microscope in intraradicular adhesive strengthFerreira, Ricardo, 1965- 02 October 2012 (has links)
Orientador: Alexandre Augusto Zaia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T22:27:52Z (GMT). No. of bitstreams: 1
Ferreira_Ricardo_D.pdf: 7849223 bytes, checksum: c0f3fb19c86238de581b6cb87528b99f (MD5)
Previous issue date: 2012 / Resumo: No tratamento endodôntico é primordial a necessidade de restaurar o elemento dental, devolvendo as suas funções, tendo em vista as possibilidades de recontaminação do sistema de canais radiculares e fraturas. Estes riscos são ainda maiores em casos de perda de estrutura dentária que necessitam de pinos intrarradiculares para reter os procedimentos restauradores. Para a restauração definitiva e imediata destes dentes, a cimentação adesiva de pinos de fibra de vidro é uma excelente opção. No entanto, a adesão à dentina radicular apresenta algumas dificuldades, em virtude de suas características morfológicas, como menor número e diâmetro de túbulos dentinários, alto fator C, distância da fonte de luz, além de resíduos de substâncias e materiais obturadores utilizados durante o tratamento endodôntico. Desta forma o objetivo deste trabalho foi avaliar a influência da limpeza mecânica das paredes dentinárias do espaço para pino, sob a visão ou não de um microscópio operatório, na resistência de união do pino de fibra à dentina radicular. Quarenta e cinco raízes de incisivos bovinos foram tratadas endodonticamente, irrigadas com hipoclorito de sódio a 5,25% e obturadas com cimento à base de eugenol Pulp Canal Sealer¿. Para o grupo 1 (G1) controle, o preparo para pino foi realizado em 10 milímetros (mm) com instrumento aquecido, brocas de Gates Glidden número (#) 5 e do sistema White Post DC© # 2, limpeza com microaplicador e álcool 70% e copiosa irrigação com solução fisiológica (NaCl). O grupo 2 (G2) após preparo idêntico, foi realizado uma limpeza superficial e delicada com uma sequência de brocas esféricas longas (HL) # 4, 2 e 1 com velocidade controlada de 500 rotações por minutos (rpm) e torque de 0,8 Newton (N), limpeza com microaplicador e álcool 70%, seguida de irrigação com NaCl. O grupo 3 (G3) teve preparo idêntico ao G2, porém esta limpeza com brocas esféricas foi realizada sob visão de um microscópio operatório com magnificação de oito vezes. Após cimentação adesiva dos pinos de fibra de vidro White Post DC© # 2 com o adesivo autocondicionante Clearfil¿ SE Bond e cimento resinoso dual RelyX¿ ARC, foram obtidos dois cortes de 1 mm de espessura de cada terço (cervical, médio e apical) e submetidos ao ensaio mecânico de cisalhamento por extrusão. Os resultados em megapascal foram analisados através do teste não paramétrico de Kruskal-Wallis (p<0,05) e teste Student-Newman-Keuls (p<0,05). O G3 apresentou maior resistência de união (2,37MPa) que o G1 (0,95MPa) e G2 (1,04MPa) que por sua vez, não diferiram entre si. Conclui-se que a limpeza mecânica das paredes dentinárias do espaço para pino com o uso superficial e delicado de brocas esféricas HL, em 500 rpm, sob magnificação de oito vezes de um microscópio operatório (G3) foi mais eficiente que os demais grupos, proporcionando maior resistência de união entre o pino de fibra e a dentina radicular / Abstract: In endodontic treatment, there is an imperative need to restore the tooth, reestablishing its functions, since there is always a risk of recontamination of the root canal system and fractures. These risks are higher when there is loss of dental structure, requiring intraradicular posts to hold the restoration procedures in place. For the definitive and immediate restoration of these teeth, adhesive bonding of fiberglass posts is a good option. However, adhesion to the root dentin presents some difficulties due to its morphological characteristics, such as reduced number of dentinal tubules, lower diameter of dentinal tubules, high C factor, distance from light source, and residues from restoring substances and materials used during the endodontic treatment. The objective of this study is, therefore, to evaluate whether mechanical cleaning of dentinal walls of the post space, whether under microscopy or not, is able to improve bond strength between the fiber post and the root dentin. The roots of 45 bovine incisive teeth were endodontically treated, irrigated with 5.25% sodium hypochlorite and restored with Pulp Canal Sealer¿. For Group 1 (G1), the control group, the post space was prepared in 10mm, with heated instrument, and cleaning was carried out using microapplicator and 70% alcohol, Gates Glidden #5 and White Post DC2© burs, with abundant irrigation with physiological saline solution (NaCl). After identical preparation for Group 2 (G2), gentle superficial cleaning was carried out using a sequence of long round # 4, 2 and 1 burs (HL), controlled speed of 500 rotations per minute (rpm) and torque of 0.8 Newton (N), cleaning using microapplicator and 70% alcohol, followed by irrigation with NaCl. Group 3 (G3) was prepared in the same way as G2, with the exception that the superficial cleaning with round burs was carried out under microscope, with a magnification of eight times. After adhesive bonding of White Post DC2© fiberglass posts using self-etching adhesive Clearfil¿ SE Bond and dual RelyX¿ ARC dual core resin cement, two 1mm thick sections were obtained from each third (cervical, middle, apical) and then submitted to the push-out test. The results in megapascal were analyzed through the Kruskal-Wallis nonparametric tests (p<0.05) and the Student-Newman-Keuls test (p<0.05). G3 presented the highest bond strength (2,37MPa) compared to G1 (0,95MPa) and G2 (1,04MPa), which, in turn, presented similar results. It is concluded that mechanical cleaning the dentinal walls of the post space with the superficial and gentle use round burs (HL) at 500 rpm, under surgical microscope with magnification of eight times (G3), showed the highest bond strength between the fiberglass post and the root dentin / Doutorado / Endodontia / Doutor em Clínica Odontológica
|
55 |
Interaction effect between multi-mode adhesive systems and dual/chemical curing resin cements on dentin bonding = O efeito da interação de sistemas adesivos multi-mode e cimentos resinosos de polimerização química e dual na adesão à dentina / O efeito da interação de sistemas adesivos multi-mode e cimentos resinosos de polimerização química e dual na adesão à dentinaGuimarães, Isadora Rabêlo, 1985- 27 August 2018 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T03:34:21Z (GMT). No. of bitstreams: 1
Guimaraes_IsadoraRabelo_D.pdf: 1408417 bytes, checksum: 663b3f486f91d8f3589f07a988f8ba2c (MD5)
Previous issue date: 2015 / Resumo: O objetivo deste estudo foi avaliar o efeito da interação de sistemas adesivos multi-mode e cimentos resinosos de polimerização química e dual sobre a superfície da dentina. Quarenta terceiros molares humanos não cariados foram separados em 5 grupos (n=8). Uma superfície plana em dentina foi obtida para cada dente. Blocos de 3,0x12x12 mm de resina composta indireta (Lava Ultimate) foram jateados com partículas óxido de alumínio e cimentados na superfície de dentina, formando os seguintes grupos: I- All Bond Universal fotoativado (AB)/C&B Bond Cement (CB); II- Scotchbond Universal fotoativado (SBU)/RelyXUltimate químico (RXU); III- SBU fotoativado/RXU fotoativado, IV- SBU químico/RXU fotoativado, V- SBU químico /RXU químico. Após a cimentação, os dentes foram mantidos em umidade relativa a 37?C por 24 horas. Os dentes foram seccionados para obter palitos de aproximadamente 0,8 mm². Os espécimes foram posicionados na máquina de ensaio universal EZ-Test para o ensaio de resistência de união com uma velocidade de 0,5 mm/min. Os dados foram estatisticamente analisados por ANOVA um fator e Teste de Fisher's PLSD (?=0,05). Os modos de fratura foram analisados e classificados em microscópio eletrônico de varredura. Para análise das interfaces dentina/adesivo/cimento, cinco espécimes de cada grupo foram corados com Rodamina B a 1% por uma hora e analisados em microscópio confocal de varredura a laser. Nenhuma diferença estatística de resistência da união (MPa) foi observada entre os grupos: I- 59,9 (9,3); II- 57,6 (15,9); III- 63,9 (12,7) e IV- 53,7 (13,9), e todos foram diferentes estatisticamente do grupo V, que apresentou o menor valor de resistência da união 16,2 (6,4). O modo de fratura coesivo foi predominante na interface entre o adesivo e cimento resinoso em todos os grupos. A análise ultraestrutural sugere a interação entre os sistemas adesivos multi-mode e o cimento resinoso na dentina, quando o adesivo ou o cimento resinoso foi fotoativado. A interação adesiva ocorreu entre os adesivos multi-mode e cimentos resinosos, sempre que o adesivo e/ou o cimento resinoso foi fotoativado / Abstract: This study evaluated the dentin surface interaction effect of multi-mode adhesives on bonding to chemical-cured and dual-cured resin cements. Forty non-carious human third molars were divided into five groups (n=8). A flat dentin surface was created for each tooth. Indirect resin composite block 3,0x12x12 mm (Lava Ultimate) were sandblasted with aluminum oxide particles and cemented to the dentin surface following the treatment groups: I- All Bond Universal light-cured/C&B Bond (self-cured cement), II- Scotchbond Universal (SBU) light-cured/RelyX Ultimate (RXU) self-cured, III- SBU light-cured/RXU light-cured, IV - SBU no light-cured/RXU light-cured and V- SBU no light-cured/RXU self-cured. After 24 h, the teeth were sectioned into beans to produce a cross-sectional area of 0.8 mm². Specimens of each group were individually mounted on a jig and placed on a tensile testing universal machine. A tensile force was applied at a 0.5mm/min cross-speed. The bond strength was recorded and failure modes were classified using scanning electron microscopy. In order to observe dentin/adhesive-cement interface, selected beans from each group were stained with 0.1% Rodhamine B for 1 h and analyzed using Confocal Laser Scanning Microscopy. Statistical analysis was performed using ANOVA and Fisher¿s PLSD test (?=0.05). For bond strength (MPa) no statistical difference of was observed among the groups: I - 59.9 (9.3); II- 57.6 (15.9); III - 63.9 (12.7) and IV- 53.7 (13.9). Group V showed statistical lower average value 16.2 (6.4) compared with all others groups. Cohesive failure modes occurred predominately along of adhesive and resin cement to all groups. The ultrastructural observation suggested the dentin surface interaction between multi-mode adhesives and resin cement when the adhesive or resin cement was light-cured. The adhesive interaction occurred between multi-mode adhesive systems and resin cements whenever the adhesive and/or resin cement was light-activated / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários
|
56 |
The association between deciduous dentin sclerosis and calcium hydroxide methyl cellulose base materialKlein, Arthur Irving, 1922- January 1958 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Seventy five children in the early mixed dentition stage with
operative dentistry completed on 351 deciduous teeth were observed
from 4 to 28 months with periodic bitewing radiographs taken at intervals
of from 4 to 10 months. These cases contained 191 deciduous
teeth in which a calcium hydroxide methyl cellulose base material was
placed beneath the alloy restorations (test teeth) and 160 deciduous
teeth in which no base material was utilized beneath the alloy restorations (control teeth). In each instance all carious dentin was removed before the base material or restoration was completed.
A visual densitometric evaluation utilizing sclerotic index
which is an estimation of the occurrence and intensity of dentin
sclerosis by inspection of bitewing radiographs. This evaluation
indicates that 93% of the test teeth gave evidence of dentin sclerosis
beneath the area of calcium hydroxide base material while 99% of
the control teeth showed no radiographic evidence of dentin sclerosis.
An instrumental densitometric evaluation was made of the projected
bitewing x-ray film images of 115 deciduous teeth utilizing
the Elwood Densitometer. The results of this evaluation indicate
a localized increase of dentin sclerosis, or dentin calcification.
Ranging from 0% to 125% in the test teeth, immediately beneath the
calcium hydroxide base material. The control teeth showed an increased
dentin density range of from 0% to 20% immediately beneath
the alloy restoration.
Histologic examination, both ground and deca1cified sections,
Were made of 20 deciduous teeth with and without calcium hydroxide
ethyl cellulose base material beneath their alloy restorations. The sections
indicated that the sclerotic areas seen radiographically
beneath the calcium hydroxide base material cannot be correlated
with the histologic picture. Microscopically this shows a markedly
irregular secondary dentin characterized by a definite
diminution of dentinal tubules, with an increased amount of dentin matrix.
These changes could have taken place as a result of age, caries or cavity preparation.
From the results of this research it is apparent that a calcium hydroxide methyl cellulose base material is effective in the production of sclerotic dentin in deciduous teeth. There is no doubt that the “white area” seen radiographically is an area of sclerosis of the existing dentin and not an area of recalcification of carious dentin.
|
57 |
Studies of tertiary dentin formation in monkey teeth utilizing vital dyesFischer, Francis M., 1938- January 1967 (has links)
Indiana University-Purdue University Indianapolis (IUPUI)
|
58 |
Avaliação in vitro da condutibilidade hidráulica da dentina após a irradiação de diferentes parâmetros de laser associados ou não com verniz fluoretado / In vitro evaluation of dentin hydraulic conductance after irradiation with different LASER parameters, associated or not with a fluoride varnishRizzante, Fabio Antonio Piola 24 February 2015 (has links)
Os tratamentos que visam a remissão dos sintomas provocados pela hipersensibilidade dentinária são baseados na obliteração física dos túbulos dentinários com o objetivo de reduzir a condutibilidade hidráulica da dentina. Nesse contexto, diversos tratamentos têm sido avaliados, entre eles, a irradiação da superfície dentinária com laser. O objetivo do presente estudo foi avaliar a condutibilidade hidráulica da dentina radicular bovina, após irradiação com um laser de diodo (980nm), associado ou não com um verniz fluoretado. Sessenta espécimes de dentina radicular bovina com dimensões 5,5 X 5,5 X 1mm foram divididos em 6 grupos (n=10): Grupos 1, 3 e 5 (laser de diodo com 0,5; 0,7 e 1W respectivamente); Grupos 2, 4 e 6 (associação entre verniz fluoretado e laser de diodo com 0,5; 0,7 e 1W). A condutibilidade hidráulica da dentina, avaliada em FLODEC, foi analisada em 4 momentos: após criação da smear layer (permeabilidade mínima), após condicionamento com gel de ácido fosfórico a 37% (permeabilidade máxima), após os tratamentos propostos e após o desafio ácido com ácido cítrico a 6%. Os dados obtidos foram avaliados pela ANOVA a 2 critérios e teste de Tukey para comparação entre os diferentes grupos e ANOVA 1 critério de medidas repetidas e teste de Tukey para comparação entre as diferentes leituras dentro de cada grupo, sempre com p<0,05%. As análises demonstraram um melhor resultado conforme o aumento da potência de irradiação, principalmente se esta for associada à aplicação do verniz fluoretado, garantindo uma melhor estabilidade dos tratamentos, mesmo após o desafio ácido. Após essa última etapa, os espécimes foram avaliados quanto à composição mineral em EDX, apresentando como principais alterações nos grupos irradiados com laser, um aumento na proporção de ions Cálcio e Fósforo, associada à redução dos íons Carbono e Oxigênio. Dessa forma, a irradiação da dentina exposta com laser de diodo promoveu redução significante na condutibilidade hidráulica, principalmente com densidades de energia mais elevadas e quando associado ao verniz fluoretado. / The dentin hypersensitivity treatments are based on the physical obliteration of dentinal tubules in order to reduce the dentin hydraulic conductance. Hence, many treatments have been evaluated, such as the dentin surface laser irradiation. The aim of the present study was to evaluate the bovine root dentin hydraulic conductance after 980nm diode laser irradiation, associated or not with a fluoride varnish. Sixty bovine root dentin specimens were divided into six groups (n=10): Groups 1, 3 and 5 (0.5, 0.7 and 1W diode laser respectively); Groups 2, 4 and 6 (association between fluoride varnish application and 0.5, 0.7 and 1W diode laser irradiation). The dentin hydraulic conductance was evaluated at 4 moments, with FLODEC: after smear layer (minimum permeability), after 37% phosphoric acid gel etching (maximum permeability), after the treatments and after 6% citric acid challenge. The analysis demonstrated a better result with increased irradiation power, especially if the diode laser irradiation was associated with the application of a fluoride varnish, ensuring a greater treatment stability, even after acid challenge. After the citric acid challenge, the specimens were evaluated for mineral composition in EDX. The irradiated groups showed, as major changes after laser irradiation, an increase in the proportion of calcium and phosphorus ions, associated with the reduction of carbon and oxygen ions. In conclusion, the laser irradiation of the exposed dentin promoted a significant reduction in hydraulic conductance, mainly with higher energy densities and when combined with a fluoride varnish.
|
59 |
Laboratory simulation of microleakage in class 5 composite resin restorations placed without retention a thesis submitted in partial fulfillment ... restorative dentistry, operative ... /Tay, Hock Hin. January 1988 (has links)
Thesis (M.S.)--University of Michigan, 1988.
|
60 |
Comparison of digital and optical criteria used for detecting sound dentin a thesis submitted in partial fulfillment ... in restorative dentistry (operative) ... /Anderson, Maxwell H. January 1982 (has links)
Thesis (M.S.)--University of Michigan, 1982.
|
Page generated in 0.0589 seconds