• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 171
  • 9
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 193
  • 193
  • 193
  • 170
  • 152
  • 71
  • 68
  • 62
  • 61
  • 51
  • 48
  • 38
  • 37
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Resistência da união da cimentação adesiva de pinos de fibra de vidro frente ao teste de remoção por extrusão / Push-out bond strength of adhesive luted glass fiber posts

Silva, Luciana Mendonça da 24 March 2009 (has links)
Este trabalho avaliou a resistência de união de pinos de fibra de vidro cimentados à dentina com o uso de um cimento resinoso convencional e um auto-adesivo. Trinta dentes bovinos unirradiculares tiveram as raízes 17mm a partir dos ápices. As raizes foram tratadas endodonticamente e divididas aleatoriamente em 3 grupos (n=10): G1- cimento resinoso convencional RelyX ARC + ScotchBond Multi Uso Plus (SBMP) fotoativado + pino de fibra de vidro; G2 RelyX ARC + SBMP quimicamente ativado + pino de fibra de vidro; G3 cimento resinoso auto-adesivo RelyX U100 + pino de fibra de vidro. Após a cimentação dos pinos, os espécimes foram armazenados por 24 horas em água destilada, à 37oC. As raízes foram cortadas sob irrigação constante para obter de 6 a 9 fatias de 1mm de espessura. O teste de resistência à extrusão foi realizado para medir a resistência adesiva nas fatias da região cervical, média e apical, a uma velocidade de 0,5mm/min. Todos os espécimes foram observados em microscópio ótico de luz para avaliar os tipos de falhas. Os valores foram submetidos à análise de variância a dois critérios (ANOVA) e teste de Tukey (p0,05). As médias gerais dos grupos 1, 2 e 3, respectivamente, (MPa) foram de 4,87 (±3,65); 5,89(±3,72); e 8,50(±4,52). Os valores de resistência adesiva regional nos terços cervical, médio e radicular, respectivamente, foram: G1- 5,26(±3,44); 5,11(±3,33); 5,01(±3,17); G2- 7,45(±3,82); 5,88(±2,50); 4,91(±2,74); G3- 10,11(±3,11); 9,12(±3,70); 4,99(±3,28). Os maiores valores de resistência adesiva foram encontrados com o cimento auto-adesivo. Ao avaliar os terços separadamente, os grupos 2 e 3 obtiveram comportamento semelhante nos terços cervical e médio. No terço apical, todos os grupos tiveram o mesmo comportamento. A resistência de união foi influenciada pelo tipo de cimento utilizado e região radicular, mas não foi alterada pela variação do modo de polimerização do sistema adesivo. / This work evaluated the bond strength of glass fiber posts to dentin using a conventional and a self-adhesive resin cement. Thirty bovine incisors had their roots sectioned 17mm from their apices, endodontically treated and assigned into 3 groups (n=10): group 1, conventional resin cement RelyX ARC + ScotchBond Multi Purpose Plus (SBMP) light activated + glass fiber post; Group 2, RelyX ARC+ SBMP chemically activated + glass fiber post; Group 3, self-adhesive resin cement RelyX U100 + glass fiber post. After luting, specimens were stored for 24 hours in distilled water at 37oC. Roots were sliced under water irrigation to obtain 1mm thick slices. Push-out test was performed on each slice with a universal testing machine with a crosshead speed of 0,5mm/min. All fractured specimens were observed using a light microscope to identify modes of failure. Values were submitted to two-way ANOVA and Tukeys test (p0,05). Mean values (MPa) and standard deviation for groups 1, 2 and 3 were, respectively: 4.87 (±3.65); 5.89(±3.72); e 8.50(±4.52). Regional bond strength values for the cervical, medium and apical were: G1- 5.26(±3.44); 5.11(±3.33); 5.01(±3.17); G2- 7.45(±3.82); 5.88(±2.50); 4.91(±2.74); G3- 10.11(±3.11); 9.12(±3.70); 4.99(±3.28). The highest bond strength values were obtained using the self-adhesive cement. Regional bond strengths were similar in the cervical and medium region in groups 2 and 3. All cements had the same performance on the apical region. Bond strength was influenced by the type of cement used and radicular region, but was not altered by the activation mode of the bonding system.
102

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Agulhari, Maria Angelica Silverio 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).
103

Avaliação longitudinal da resistência de união de pinos de fibra de vidro à dentina cimentados com quatro agentes cimentantes por meio do teste de push-out

Tawil, Rosalyn Chidiak 02 December 2008 (has links)
Avaliou-se a resistência de união do pino de fibra de vidro à dentina cimentado com quatro agentes cimentantes, por meio do teste push-out realizado após 24 horas e seis meses de armazenagem. Foram selecionados 80 dentes humanos uniradiculares, tratados endodonticamente e divididos aleatoriamente em quatro grupos (n=20), variando-se o tipo de cimento utilizado: grupo I: cimento de ionômero de vidro reforçado com resina (Fuji PlusTM, GC Corp., Tokyo, Japan); grupo II: cimento resinoso usando sistema adesivo convencional de 3 passos de aplicação (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); grupo III: cimento resinoso usando sistema adesivo autocondicionante de 1 passo de aplicação (PanaviaTM F, Kuraray, Osaka, Japan); e grupo IV: cimento resinoso auto-adesivo (BisCemTM, Bisco Inc., Schaumburg, IL). Cada grupo foi subdividido em dois subgrupos (N=10) variando-se o tempo de armazenagem (24 horas e seis meses). O teste de push-out foi realizado com uma velocidade de 1,0 mm/min, e os resultados expressos em Mega Pascal (MPa). Após o teste de push-out, todos os espécimes foram observados em microscópio óptico de fluorescência (40x) e analisado o tipo de falha apresentado entre o complexo pino/cimento/dentina radicular. Os valores médios de resistência (MPa) foram submetidos ao teste ANOVA a dois critérios e de Tukey (p<0,005). A análise estatística mostrou: 1) Diferenças significativas na resistência de união entre os cimentos utilizados, sendo que a média total do cimento resinoso RelyXTM ARC + ScotchbondTM MultipurposeTM foi superior aos dos outros cimentos após 24 horas; 2) A resistência de união dos cimentos resinosos RelyXTM ARC + ScotchbondTM MultipurposeTM e PanaviaTM F foram superiores aos outros cimentos quando testados após seis meses de armazenagem e não houve diferença significativa entre eles; 3) Após seis meses de armazenagem, observou-se um aumento na resistência de união de todos os cimentos; 4) Na análise por terços, foi observado que tanto após 24 horas quanto após seis meses, o terço cervical teve uma maior resistência de união do que o terço médio e apical; 5) Foram observadas predominantemente falhas mistas, apresentado-se na maioria dos casos a combinação de falha adesiva na interface pino/cimento e na interface cimento/dentina para todos os grupos. Concluiu-se que a resistência de união aumentou após seis meses de armazenagem graças possivelmente à expansão higroscópica e aumento da retenção friccional. / The bond strength of a glass fiber post luted to dentin with four luting agents was evaluated using the push-out test, after 24-hours and six months of storage. Eighty human single-routed teeth was selected, endodontically treated and randomly divided into four groups (n=20), modifying the luting agent used: group I: resin modified glass-ionomer (Fuji PlusTM, GC Corp., Tokyo, Japan); group II: resin cement using total-etch, three step adhesive system (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); group III: resin cement using self-etch one step adhesive system (PanaviaTM F, Kuraray, Osaka, Japan); and group IV: self-adhesive resin cement (BisCemTM, Bisco Inc., Schaumburg, IL). Each group was, then, subdivided into two subgroups (n=10) modifying the storage period (24-hours and six months). The push-out test was performed with a cross-speed of 1,0 mm/min, and the results expressed in Mega Pascal (MPa). After the test, all specimen interfaces were examined with the aid of a fluorescence optic microscope (40x) to dertemine the type of failure at the complex post/cement/dentin. The mean values of the bond strength (MPa) were analyzed with the two-way ANOVA and Tukey test (p<0,005). The statistical analysis showed: 1) Significant difference in the bond strength between the luting agents, in wich the mean total value of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM was the highest after 24 hours; 2) The bond strength of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM and PanaviaTM F were higher than the others luting agents when evaluated after six months, and there was no significant difference among both of them; 3) An increase in the bond strength of all luting agents after six months of storage in distilled water; 4) That the cervical third had a higher bond strength compared to the middle and apical thirds for all materials, during third analysis after 24-hours and six months of storage; 5) Predominantly, it was observed mixed failures, in the majority of the cases, with a combination of adhesive failure in the post/luting agent interface and in the luting agent/radicular dentin interface. Therefore, can be concluded that the bond strength of a glass fiber post luted to dentin with different luting agents can increase after six months of storage, possibly contributed by hygroscopic expansion and the increase of the frictional retention.
104

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Morais, Renata Costa de 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
105

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Renata Costa de Morais 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
106

AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA

Sánchez-ayala, Alfonso 31 January 2008 (has links)
Made available in DSpace on 2017-07-24T19:21:56Z (GMT). No. of bitstreams: 1 Alfonso Sanchez-Ayala.pdf: 4109673 bytes, checksum: f08284c2e1c48354c9d9e417e1b9484e (MD5) Previous issue date: 2008-01-31 / The aim of this study was to evaluate in vitro the adhesive effectiveness in class V cavities using four different adhesive systems, being submit to thermocycling and occlusal load cycling. The cavities had a dimension of 3x2x1.8 mm3 and were made on amelo-cement junction on buccal and lingual of 80 human premolars (n=160). The used adhesive systems were Adper Single Bond 2, AdheSE, Adper Prompt LPop and One Coat 7.0. The used composite was Synergy® D6. The adhesive and photopolymerization (600 mW/cm2) proceedings were made conventionally and following the manufacturer recommendations. The specimens were divided in 4 groups (n=40) according to adhesive system used. Each group was divided in 4 subgroups (n=10) according to applycated stress (thermocycling, occlusal load cycling and thermocycling+occlusal load cycling). Each subgroup included 1 control group without stressing. The thermocycling was made using 500 cycles, with 5-55 C, dwell time of 15 seg and transfer time of 5 seg. The occlusal load cycling was made applying a force of 40-70 N during 50000 cycles with 2 Hz of frequency. Later, the specimens were impermeabilited and immersed in tracer agent of 50 % silver nitrate solution by 2 hours. Finally, the specimens were prepared for adhesive effectiveness evaluation through optic microscopy 40X (marginal microleakage occurrence) and scanning electronic microscopy 1000X (gaps formation). The tracer agent microleakage was measured qualitative (score) and quantitatively . The gap width was measured on 3 points of center of axial wall. The Kruskal-Wallis and post-hoc de Dunn, and ANOVA two-way and post-hoc Bonferroni tests were used on statistic analysis. Despite of few differences found in used adhesive system performance, the tendency could be observed to the increase of the marginal microleakage in the submitted groups specifically to thermocycling. On the other hand, the axial gaps formation presented progressively higher width in the submitted groups to thermocycling, occlusal load cycling and thermocycling+occlusal load cycling. It was concluded that the used adhesive system presented similar adhesive effectiveness when were submitted to thermal and mechanical stress. / A proposição deste estudo foi avaliar in vitro a efetividade adesiva em cavidades de classe V utilizando quatro diferentes sistemas adesivos, sendo submetidas a termociclagem e carga cíclica oclusal. As cavidades tiveram uma dimensão de 3x2x1.8 mm3 e foram realizadas na união amelo-cementária em vestibular e lingual de 80 pré-molares humanos (n=160). Os sistemas adesivos empregados foram Adper Single Bond 2, AdheSE, Adper Prompt L-Pop e One Coat 7.0. A resina composta utilizada foi Synergy D6. Os procedimentos de adesão e fotopolomerização (600 mW/cm2) foram realizados convencionalmente e seguindo as recomendações do fabricante. Os espécimes foram divididos em 4 grupos (n=40) segundo o tipo sistema adesivo utilizado. Cada grupo foi dividido em 4 subgrupos (n=10) segundo o tipo de estresse aplicado (termociclagem, carga cíclica oclusal e termociclagem+carga cíclica oclusal). Cada subgrupo incluiu 1 grupo controle sem estresse. A termociclagem foi realizada utilizando 500 ciclos a 5-55 C, 15 seg de tempo de permanência em cada temperatura e 5 seg de tempo de transferência. A carga cíclica oclusal foi realizada aplicando uma força de 40-70 N durante 50000 ciclos com freqüência de 2 Hz. Posteriormente, os espécimes foram impermeabilizados e imersos em agente traçador de solução a 50 de nitrato de prata por 2 horas. Finalmente, os espécimes foram preparados para a avaliação da efetividade adesiva por meio de microscopia óptica 40X (ocorrência de microinfiltração marginal) e microscopia eletrônica de varredura 1000x (formação de fendas). A microinfiltração do agente traçador foi mensurada qualitativa (escore) e quantitativamente . A largura das fendas foi medida (μm) em 3 pontos do centro da parede axial. Os testes de Kruskal-Wallis e post-hoc de Dunn, e ANOVA two-way e post-hoc Bonferroni foram utilizados na análise estatística. Apesar das poucas diferenças significativas encontradas no desempenho dos sistemas adesivos utilizados, pôde-se observar a tendência ao aumento da microinfiltração marginal nos grupos submetidos especificamente a termociclagem. Por outro lado, a formação de fendas axiais apresentaram progressivamente maior largura nos grupos submetidos a termociclagem, carga cíclica e termociclagem+carga cíclica. Concluise que os sistemas adesivos avaliados apresentaram efetividade adesiva similar quando foram submetidos a estresse térmico e mecânico.
107

EFEITO DE AGENTES DESSENSIBILIZANTES INCORPORADOS AO ADESIVO NO TRATAMENTO DA HIPERSENSIBILIDADE DENTINÁRIA CERVICAL – ESTUDO IN VITRO E IN VIVO / EFEITO DE AGENTES DESSENSIBILIZANTES INCORPORADOS AO ADESIVO NO TRATAMENTO DA HIPERSENSIBILIDADE DENTINÁRIA CERVICAL – ESTUDO IN VITRO E IN VIVO / Effect of desensitizing agents incorporated into the adhesive in the treatment of cervical dentinal hypersensitivity – In vitro and in vivo study / Effect of desensitizing agents incorporated into the adhesive in the treatment of cervical dentinal hypersensitivity – In vitro and in vivo study

Zardo, Ligia Nadal 24 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:02Z (GMT). No. of bitstreams: 1 Ligia Zardo.pdf: 3241924 bytes, checksum: 551ba34ed43ba3f5c10b208bb4902ff8 (MD5) Previous issue date: 2016-02-24 / The dentin hypersensitivity (DH), characterized by discomfort caused by pain, is a common medical condition that requires the professional challenge in choosing appropriate therapy. From this perspective the present study was structured in three stages. The first consisted in the review of the literature available in PubMed, Scielo, Bireme, Cochrane, in order to discuss etiology and prevalence of cervical dentin hypersensitivity, pain mechanism theory and those adopted therapeutic procedures and their effectiveness. The second consisted of an in vitro study to evaluate the physical and chemical characteristics and the potential obliteration of dentinal tubules by desensitizing agents incorporated into the Ambar adhesive. For that were used 72 samples from 36 bovine teeth divided into 6 groups: ambar + SrCl2 group, ambar + NaF group, ambar + SnF2 group, ambar + KNO3 group, ambar + K2C204 group and ambar group. The specimens were prepared for hydraulic conductance test or dentin permeability (n = 30), Scanning Electron Microscopy (SEM) (n = 18), Spectroscopy Micro Raman (n = 12), and energy dispersive spectroscopy (EDS) (n = 12). Data were analyzed with analysis of variance (ANOVA) of one criterion and the significance level was 5%. A reduction in dentin permeability in the treated groups, but no significant differences seen between the groups (p = 0.134). By Micro Raman was possible to observe the behavior of the molecules of chemical compounds of desensitizing salts embedded in the adhesive remained adhered to dentin surface. In the SEM, to dentin surface completely covered and sealed with adhesive and the presence of the desensitizing salts, because the EDS spectrum revealed the presence of NaF and KNO3 clusters dispersed in the adhesive layer. It is concluded from this study that the occlusive agents NaF, SnF2, SrCl2, KNO3, K2C2O4 remained incorporated into the dentin adhesive, although clusters in the adhesive layer, the group was able to obliterate the tubules and reduce dentin permeability. The third stage aimed to identify the desensitizing effect of therapies and monitor the longevity of the effects of desensitizing agents on dentin hypersensitivity. Evaluated desensitizing therapies were: group 1: Ambar + NaF, group 2: Ambar + KNO3; group 3: Low level laser therapy; group 4: Led; group 5: Clinpro XT and group 6: Ambar adhesive. The radomizaded clinical trial, parallel-type, blind placebo-controlled included the participation of 60 patients, with an eligible tooth, causing pain quantified by Verbal Scale of 4 points (VRS) and Numerical Scale of 101 points (NRS 101) after tactile and thermal stimuli immediately after the procedure, 24 hours, 7, 15, 30, 90 and 180 days after the completion of the procedures. The dependent variable intensity of pain against the tactile stimulation (probe) and thermal (water) was analyzed for each trial using the non-parametric test Kruscal- Wallis. In periods when there was a statistically significant difference, the comparison of peer groups was made utilizando- the Mann-Whitney test. The ionomer sealant Clinpro XT was more effective in the immediate reduction of DH, and maintained its long-term effect. The NaF + adhesive and KNO 3 + adhesive groups were effective in the treatment of DH and responded better to treatment than just the Ambar adhesive. At the end of the six-month evaluation, all evaluated desensitizing agents were effective in reducing pain resulting from tooth sensitivity. / A hipersensibilidade dentinária (HD), caracterizada pelo desconforto causado por dores, é uma situação clínica frequente que impõe ao profissional um desafio na escolha de uma terapia adequada. Nessa perspectiva o presente estudo foi estruturado em três etapas. A primeira constituiu-se na revisão da literatura disponível nas bases Pubmed, Scielo, Bireme, Cochrane, visando discutir etiologia e prevalência da hipersensibilidade dentinária cervical, teoria de mecanismo da dor bem como as condutas terapêuticas adotadas e a eficácia das mesmas. A segunda constituiu-se de um estudo in vitro para avaliar as características físico-químicas e o potencial de obliteração dos túbulos dentinários por agentes dessensibilizantes incorporados ao adesivo Ambar. Para tanto foram utilizadas 72 amostras provenientes de 36 dentes bovinos divididos em 6 grupos experimentais: grupo ambar + SrCl2, grupo ambar + NaF, grupo ambar + SnF2, grupo ambar + KNO3, grupo ambar + K2C204 e grupo ambar. Os espécimes foram preparados para o teste de condutância hidráulica ou permeabilidade dentinária (n=30), Microscopia Eletrônica de Varredura (MEV)(n=18), Espectroscopia Micro Raman (n=12), e Espectroscopia de Energia Dispersiva (EDS)(n=12). Os dados foram analisados com Análise de Variância (ANOVA) de um critério e o nível de significância adotado foi de 5%. Houve redução da permeabilidade dentinária nos grupos tratados, porém sem diferenças consideradas significativas entre os grupos (p= 0,134). Através do Micro Raman foi possível observar o comportamento das moléculas dos compostos químicos dos sais dessensibilizantes incorporados no adesivo que permaneceram aderidos a superfície dentinária. No MEV observou-se a superfície dentinária totalmente recoberta e selada com adesivo e a presença dos sais dessensibilizantes, já o espectro do EDS revelou a presença de aglomerados de NaF e KNO3 dispersos na camada de adesivo. Conclui-se com este estudo que os agentes oclusivos NaF, SnF2, SrCl2, KNO3 e K2C2O4 permaneceram incorporados ao adesivo dentinário e que apesar de aglomerados na camada do adesivo, o conjunto foi capaz de obliterar os túbulos e reduzir a permeabilidade dentinária. A terceira etapa visou identificar in vivo o efeito dessensibilizante das terapias e acompanhar a longevidade dos efeitos do agente dessensibilizante sobre a hipersensibilidade dentinária. As terapias dessensibilizantes avaliadas foram: grupo 1: Ambar + NaF, grupo 2: Ambar + KNO3; grupo 3: Laser de baixa intensidade; grupo 4: Led, grupo 5: Clinpro XT e grupo 6: adesivo Ambar. O ensaio clínico radomizado, cego do tipo paralelo controlado por placebo contou com a participação de 60 pacientes, com um dente elegível, sendo a dor quantificada através da Escala Verbal de 4 pontos (VRS) e Escala Numérica de 101 pontos (NRS 101) após estímulos tátil e térmico, imediatamente após a realização do procedimento, 24 horas, 7, 15, 30, 90 e 180 dias após a conclusão dos procedimentos. A variável dependente intensidade de dor frente ao estímulo tátil (sonda) e térmico (água) foi analisada para cada período experimental utilizando-se o teste não paramétrico de Kruscal-Wallis. Nos períodos em que houve diferença estatisticamente significante, a comparação dos pares de grupos foi feita utilizando- se o teste de Mann-Whitney (p< 0.05). O selante ionomérico Clinpro XT mostrou-se mais efetivo na redução imediata da HD, e manteve seu efeito a longo prazo.
108

Avaliação da dureza e módulo de elasticidade da interface de união resina – dentina utilizando a técnica de nanoindentação / Assessment of hardness and elastic modulus of resin-dentin bonding area using the nanoindentation technique

Higashi, Cristian 28 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 Cristian Higashi.pdf: 1616679 bytes, checksum: a243cd9970614325c2c06ab7c7f592d1 (MD5) Previous issue date: 2008-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the hardness and elastic modulus of resin-dentin bonding area formed by an ethanol/water-based (Adper TM Single Bond 2 [SB]) and an acetone-based system (One Step Plus [OS]), under different moisture conditions and application methods. On 24 human molars, a flat superficial dentin surface was exposed by wet abrasion. Two coats of SB or OS adhesive were applied on either a dry (D) or rewetted surface (W), under active (AA) or inactive (IA) application. After polymerization of the adhesives (600 mW/cm2/20 s), composite build-ups were constructed incrementally and specimens were stored in water (24 h). They were cross-sectioned perpendicular to the resin-dentin interface to obtain slices of 1.5 mm thickness that were embedded and polished before the test. Nanoindentations were made on composite resin, adhesive system, hybrid layer and dentin regions. The results of hardness and elastic modulus (GPa) of adhesive system and hybrid layer were analyzed by a three-way ANOVA and Tukey’s multiple comparison tests (α=0.05). The mean and standard deviation of hardness and elastic modulus values of composite resin were (1.02 ± 0.07) and (14.94 ± 0.67) respectively. In dentin, the hardness was (0.69 ± 0.10) and the elastic modulus (17.94 ± 1.84). In the adhesive layer, the highest hardness (0.38 ± 0.06) and elastic modulus (6.93 ± 0.93) of SB were obtained in W group. In this same area, the elastic modulus of OS (5.91 ± 1.12) was lowest in AA group. In the hybrid layer, the hardness of both adhesive systems was highest in AA group, however statistically significant just for OS (0.51 ± 0.2). In D group the highest hardness (0.47 ± 0.24) and elastic modulus (10.98 ± 4.65) of hybrid layer were obtained with AA. It was concluded that the active application of both adhesives in dry dentin resulted in higher hardness and elastic modulus values in the hybrid layer and the moisture increased hardness and elastic modulus values of Adper TM Single Bond 2 in the adhesive layer. / O objetivo deste trabalho foi avaliar a dureza e módulo de elasticidade da interface de união resina-dentina formado por adesivos convencionais de 2 passos à base de água/etanol (Adper TM Single Bond 2 [SB]) e à base de acetona (One Step Plus [OS]), variando a umidade dentinária e forma de aplicação dos mesmos. 24 terceiros molares humanos foram lixados para a obtenção de uma superfície dentinária plana. Duas gotas do adesivo SB ou OS foram aplicadas de forma ativa (AA) ou inativa (AI) sobre uma dentina seca (S) ou reumedecida (U). Após a fotopolimerização dos adesivos (600 mW/cm2 / 20 s) os dentes foram restaurados incrementalmente e armazenados em água destilada por 24 h. Cortes perpendiculares à interface de união foram realizados para obtenção de fatias de aproximadamente 1,5 mm de espessura, que foram embutidas e polidas previamente ao teste. Nanoindentações foram realizadas nas regiões da resina composta, sistema adesivo, camada híbrida e dentina. Os valores de dureza e módulo de elasticidade (GPa) do sistema adesivo e camada híbrida foram submetidos a uma análise de variância de 3 fatores de medidas repetidas e ao teste de comparações múltiplas de Tukey (α=0,05). A média e desvio padrão dos valores de dureza e módulo de elasticidade da resina composta (GPa) foram (1,02 ± 0,07) e (14,94 ± 0,67), respectivamente. Na dentina, a dureza foi (0,69 ± 0,10) e o módulo de elasticidade (17,94 ± 1,84). Na camada de adesivo, os maiores valores de dureza (0,38 ± 0,06) e módulo de elasticidade (6,93 ± 0,93) do SB foram obtidos no grupo U. Nesta mesma região, o módulo de elasticidade do OS (5,91 ± 1,12) foi menor para o grupo AA. Na região da camada híbrida, a dureza de ambos os sistemas adesivos foi maior no grupo AA, porém significativamente somente para o OS (0,51 ± 0,2). No grupo S os maiores valores de dureza (0,47 ± 0,24) e módulo de elasticidade (10,98 ± 4,65) da camada híbrida foram obtidos com AA. Concluiu-se que a aplicação ativa de ambos os sistemas adesivos em substrato dentinário seco resultou nos maiores valores de dureza e módulo de elasticidade na região da camada híbrida e a umidade dentinária influenciou positivamente nos valores de dureza e módulo de elasticidade do sistema adesivo Adper TM Single Bond 2 na região da camada de adesivo.
109

Efeito do armazenamento em água na resistencia de União de diferenets abordagens de adesão a dentina / Effects of water storage on resin-dentin bond strengths formed by different bonding approaches

Martins, Gislaine Cristine 21 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 Gislaine Cristine Martins.pdf: 4206631 bytes, checksum: c89ea8320c5c7cd1115382f7f0e02b50 (MD5) Previous issue date: 2008-02-21 / The purpose of this study was to evaluate the effects of water storage on resindentin bond strengths [μTBS] formed by different adhesive bonding approaches. A flat superficial dentin surface the 24 human third molars were exposed and polished to create a standardized smear layer. The teeth were randomly distributed into four different: total-etch 3 step (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP), and total-etch 2 step (Adper™ Single Bond 2, 3M ESPE - SB); self-etch 2 step (AdheSE, Ivoclar/Vivadent - AD); and self-etch 1 step (Adper™ Prompt™ LPop ™, 3M ESPE - LP). Following the adhesive application (n=6), resin composite crowns were incrementally placed (Filtek™ Supreme XT - 3M ESPE) in order to obtain bonded sticks, with a cross-sectioned area of about 0,8 mm2. The bonded sticks were randomly divided and assigned to be tested immediately [IM] (n=30) or after 6 months of water storage [6M](n=30). Two-way ANOVA and Tukey’s test showed that none of the adhesives showed degradation after 6 months, except SB, which was the one that achieved the highest μTBS either in the immediate time (49.13 MPa) and after 6 months (40.27 MPa). LP showed the lowest μTBS in both periods of evaluation (18.35 and 18.34 MPa). AD and SBMP showed intermediate performance. But the SB showed lower μTBS significantly after storage anyway showed high results. Conclusion: Although a significant degradation was only observed for SB, this was the adhesive that showed the highest μTBS after 6M of water storage. It seems that the microtensile test is not sensitive to detect degradation for adhesives with low immediate μTBS. / Este estudo objetivou avaliar o efeito do armazenamento em água na resistência de união [μTBS] de diferentes abordagens de adesão à dentina. As superfícies oclusais de 24 terceiros molares hígidos foram cortadas, planificadas e, a smear layer padronizada. Os dentes foram divididos aleatoriamente em 4 grupos de acordo com a abordagem de união, ou seja, convencionais, de 3 passos (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP) e, de 2 passos (Adper™ Single Bond 2, 3M ESPE -SB); autocondicionantes, de 2 passos (AdheSE, Ivoclar/Vivadent - AD) e, de 1 passo (Adper™ Prompt™ L-Pop™, 3M ESPE - LP). Após o procedimento adesivo (n=6) os dentes foram restaurados pela técnica incremental com resina composta Filtek™ Supreme XT (3M ESPE). Obteve-se 240 espécimes em forma de palitos com área aproximada de 0,8 mm2. Dos espécimes obtidos para cada grupo (n=60), metade foi submetido ao teste de resistência de união imediato [IM] (n=30) e, a outra metade foi armazenada em água para realização do teste após 6 meses de armazenamento [6M](n=30). A ANOVA 2 fatores e o pós-teste de Tukey mostraram que não ocorreu degradação após 6M, exceto para o SB, ainda assim, a maior média da resistência de união IM e 6M foi do SB (49.13 e 40.27 MPa). O LP mostrou as menores médias nos dois períodos de avaliação (18.35 e 18.34 MPa). O AD e o SBMP apresentaram desempenho intermediário. Entretanto, o SB apresentou redução significativa da resistência de união após 6M, apesar disso, obteve os melhores resultados. Concluiu-se que embora ocorreu uma degradação significativa para o SB, este sistema foi o que apresentou maior μTBS após 6 meses de armazenamento em água. O teste de microtração não foi sensível para detectar a degradação dos sistemas adesivos com valores mais baixos de μTBS.
110

EFEITO DA INCLUSÃO DE PARTÍCULAS DE CARGA NA RADIOPACIDADE E EM PROPRIEDADES DE SISTEMAS ADESIVOS EXPERIMENTAIS / Effects of of filler addition to experimental adhesives on radiopacity and properties

Martins, Gislaine Cristine 13 November 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1 Gislaine Cristine Martins.pdf: 4074240 bytes, checksum: e09201e7bd1d75eac883e17325cc0c46 (MD5) Previous issue date: 2012-11-13 / The aim of this study was to evaluate the radiopacity, ultimate tensile strength (UTS), microhardness (KHN), degree of conversion (DC), water sorption (WS), solubility (SO), microtensile bond strength (μTBS) and of experimental dental adhesives with increased addition of barium-borosilicate zirconia nanoparticles or glass microparticles. Methods: Ten experimental adhesive systems with different concentrations of zirconia nanoparticles [0(EX0), 15(EX15), 25(EX25), 35(EX35) and 50%(EX50) and barium-borosilicate oxide microparticles [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] were formulated based on the adhesive system Ambar (FGM). The adhesive Adper Single BondTM 2 (SB, 3M ESPE) was used as commercial reference. For the radiopacity (n=5), KHN (n=5), WS (n=10) and SO (n=10) tests, adhesive specimens were constructed using a stainless steel mold (5.0 mm in diameter and 1.0 mm in deep), while for UTS (n=5), a hourglass shape metallic matrix (10 mm long, 2 mm wide, and 1 mm deep with cross-sectional area of 0.8 mm2) was employed.The FTIR spectra of uncured and cured specimens of adhesives were used to determine the DC of the materials. For μTBS, adhesives were applied to flat dentin surfaces of third molars (n=7). Resin composite buildups were constructed and sectioned to obtain resin-dentin bonded sticks to tested immediately (IM) or after 6 months (6M) of water storage. Data were submitted to a one-way ANOVA and Tukey´s test (α=0.05). Results: All experimental bonding adhesives showed radiopacity similar to enamel. Only R60 showed higher UTS than the other materials. The experimental adhesives showed higher KHN values when compared to the commercial SB. In general, the DC of the experimental solutions was not affected by filler addition and was statistically higher than SB. Although filler addition did not affect WS, it generally reduced the SO. Most of the experimental adhesives showed lower WS and SO than SB. Conclusions: Both the addition of nanoparticles as microparticles were able to confer radiopacity to adhesives experimental, and adding load influence on the properties tested. In general, it can be said that the best performance was for the addition of microparticles in a concentration of 30%. / Objetivo: Este estudo objetivou avaliar a radiopacidade, resistência máxima à tração,(RMT), microdureza (KHN), grau de conversão (GC), sorção de água (SA),solubilidade (SO), resistência de união (μTBS) de sistemas adesivos experimentais pela adição de nanopartículas de zircônia ou micropartículas de vidro de bárioborosilicato. Material e métodos: Dez sistemas adesivos experimentais com diferentes concentrações de nanopartículas de zircônia [0(EX0), 15(EX15), 25(EX25), 35(EX35) e 50%(EX50) ou com micropartículas de óxido de bário-borosilicato [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] foram formulados tendo como base o sistema adesivo Ambar (FGM). O sistema adesivo Adper Single BondTM 2 (SB, 3M ESPE) foi utilizado como referência comercial. Foram confeccionados espécimes de adesivo para os testes de radiopacidade (n=5), KHN (n=5), SA (n=10) e SO (n=10) utilizando matriz metálica com 5,0 mm de diâmetro e 1,0 mm de profundidade e, para a RMT (n=5) uma matriz metálica com 10 mm de comprimento, 2 mm de largura, 1 mm de profundidade e, área de sessão transversal de 0,8 mm2. Os espectros FTIR foram obtidos de espécimes não polimerizados e polimerizados dos adesivos para determinar o GC dos materiais. Para μTBS, aplicou-se os adesivos na superfície de dentina de dentes molares humanos (n=7). Os dentes foram reconstruídos com resina composta e cortados para obtenção de espécimes em forma de palitos que foram testados imediatamente (IM) ou após 6 meses de armazenamento em água (6M). Os dados foram submetidos a ANOVA e pós-teste de Tukey´s (α=0,05). Resultados:Todos os sistemas adesivos experimentais mostraram radiopacidade semelhante a do esmalte dental. Apenas o R60 mostrou valores de RMT mais elevado que os outros materiais. Os sistemas adesivos experimentais apresentaram valores mais altos de dureza Knoop quando comparado ao SB. Em geral, o GC dos adesivos experimentais não foi afetado pela adição de partículas e, significantemente superior ao SB. A maioria dos adesivos experimentais mostraram menor SA e SO que o SB.Conclusões: Tanto a adição de nanopartículas quanto de micropartículas foi capaz de conferir radiopacidade aos adesivos experimentais e, a adição de carga influenciou nas propriedades testadas. De modo geral, pode-se dizer que o melhor desempenho foi para a adição de micropartículas na concentração de 30%.

Page generated in 0.1184 seconds