• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 11
  • 2
  • 2
  • 1
  • Tagged with
  • 35
  • 35
  • 35
  • 24
  • 13
  • 11
  • 10
  • 10
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular : análise da distribuição das tensões pelo método da fotoelasticidade /

Ferraço, Renato. January 2009 (has links)
Resumo: A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture - fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) "I" bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) "I" bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Stefan Fiuza de Carvalho Dekon / Banca: Marcelo Coelho Goiato / Banca: Fellippo Ramos Verri / Mestre
22

The use of "fluid-resins" for relining partial dentures a thesis submitted in partial fulfillment ... in denture prosthesis ... /

Cabrera-Diaz, Renato. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971.
23

Plaque formation and gingival inflammation as influenced by the major connector design of the mandibular removable partial denture a thesis submitted in partial fulfillment ... denture prosthodontics /

Vafa, Mehrangiz. January 1979 (has links)
Thesis (M.S.)--University of Michigan, 1979.
24

A survey of partial denture construction at University of Michigan School of Dentistry, 1965-1966 a thesis submitted in partial fulfillment ... denture prosthesis ... /

Gingles, Carl E. January 1900 (has links)
Thesis (M.S.)--University of Michigan, 1967.
25

The use of "fluid-resins" for relining partial dentures a thesis submitted in partial fulfillment ... in denture prosthesis ... /

Cabrera-Diaz, Renato. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971.
26

Plaque formation and gingival inflammation as influenced by the major connector design of the mandibular removable partial denture a thesis submitted in partial fulfillment ... denture prosthodontics /

Vafa, Mehrangiz. January 1979 (has links)
Thesis (M.S.)--University of Michigan, 1979. / eContent provider-neutral record in process. Description based on print version record.
27

Efeito da reabilitação protetica removivel bucal na espessura muscular e força de mordida em crianças na dentição mista / Effect of the removable prosthetic rehabilitation on muscle thickness and bite force of children in the mixed dentition

Serra-Vicentin, Marcia Diaz 22 February 2006 (has links)
Orientador: Maria Beatriz Duarte Gavião / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T02:26:00Z (GMT). No. of bitstreams: 1 Serra-Vicentin_MarciaDiaz_M.pdf: 1071000 bytes, checksum: 4ba29129af85ef19f21717f7287f9119 (MD5) Previous issue date: 2006 / Resumo: O objetivo deste estudo foi avaliar a força de mordida e a espessura dos músculos mastigatórios em 25 crianças com perda precoce de dentes decíduos posteriores antes e após reabilitação bucal com prótese parcial removível. Para tanto, o estudo é composto de três capítulos. No capítulo 1, intitulado Maximum bite force ¿ a review of the literature, realizou-se a revisão de literatura sobre força de mordida e discorreu-se sobre as variáveis influenciadoras. A revisão mostrou que a força de mordida tem sido amplamente avaliada e associada às variáveis morfológicas e funcionais do sistema mastigatório. No capítulo 2 intitulado A six-month evaluation of maximum bite force in wearing a removable dental prosthesis avaliou-se a força de mordida das crianças, e no capítulo 3, intitulado Masseter and temporalis muscle thickness of children wearing removable dental prosthesis ¿ a six-month evaluation avaliou-se a espessura dos músculos masseter e porção anterior temporal através da ultra-sonografia. Avaliou-se também as variáveis corporais, representadas por proporções faciais, peso e altura nos capítulos 2 e 3. A força de mordida foi obtida utilizando-se um transmissor constituído de um tubo de fibra reforçada, pressurizado, conectado ao sensor de pressão (MPX 5700 Motorola). A espessura dos músculos foi avaliada nas posições mandibulares de máxima contração e repouso, com o equipamento digital Just Vision 200 (Toshiba Corporation, Japão), com transdutor linear de 56 mm, banda-larga de 10 MHz. As proporções faciais foram determinadas através de mensurações da face em fotografias padronizadas. Na análise dos dados do segundo e terceiro capítulo utilizou-se o teste de Shapiro-Wilk para verificação da normalidade da distribuição dos dados. Os testes t pareado e t independente, Wilcoxon, Mann-Whitney, Correlação de Pearson ou de Spearman e modelos de regressão ajustados foram aplicados quando indicados, com nível de significância de 5%. Os resultados mostraram que não houve diferenças estatísticas entre os sexos para nenhuma das variáveis (p>0,05). Houve aumento significativo de espessura muscular entre contração e repouso; entre força de mordida e espessura do masseter (relaxado e contraído) após 6 meses da instalação do aparelho protético; o músculo temporal relaxado mostrou-se maior antes da instalação do aparelho protético (p<0,05), o que não aconteceu para o temporal contraído (p>0,05). Não foram encontradas correlações entre proporções faciais e espessura muscular ou força de mordida (p>0,05). Considerando as variáveis corporais, houve correlação significativa entre espessura do masseter relaxado e altura corpórea na primeira sessão de exames, e entre espessura do masseter (contraído e relaxado) e todas as variáveis corporais na segunda sessão (p<0,05); com relação ao temporal, foi encontrada correlação significativa entre o músculo contraído e altura corpórea na primeira sessão e entre o músculo relaxado e peso corpóreo na segunda sessão de exames (p<0,05). Com relação à força de mordida foi encontrada correlação com altura corpórea somente segunda sessão de exames (p<0,05). Dentro dos limites deste estudo podemos concluir que a prótese parcial removível influenciou os aspectos morfológicos dos músculos, determinado aumento da espessura muscular, e o aspecto funcional, aumentando a força de mordida / Abstract: The aim of this study was to evaluate the maximum bite force and the thickness of the masseter and anterior portion of the temporalis muscles in twenty-five children with early loss of primary teeth, before and six months after oral rehabilitation with removable dental prosthesis. Three chapters compose the study. In chapter 1, entitled Maximum bite force ¿ a review of the literature, a review of the pertinent literature about maximum bite force was done, and the influencing variables were discussed. The review showed that bite force has been widely evaluated and associated to the morphological and functional variables of the masticatory system. The second chapter, entitled A six-month evaluation of maximum bite force in wearing a removable dental prosthesis it was evaluated the bite force of the children; and in chapter 3, entitled Masseter and temporalis muscle thickness of children wearing removable dental prosthesis ¿ a six-month evaluation evaluated the thickness of the masseter and anterior portion of the temporalis muscles by means of ultrasonography. Also, it was evaluated the body variables, represented by facial proportions, weight and height in chapters 2 and 3. Bite force was determined with a pressurized transducer, which consisted of a pressurized rubber tube connected to a sensor element (MPX 5700, Motorola SPS, Austin, TX, USA). Muscle thickness was measured during relaxation and maximum clenching, using the Just-vision 200 digital ultrasonography system (Toshiba Corporation, Japan) with a high-resolution real-time 56 mm/10-MHz linear-array transducer. Facial proportions were determined through measurements of the face in standard photographs. For data analysis in the second and third chapters, the normality of the distributions was assessed by the Shapiro-Wilks W-test. The t paired or unpaired tests, Wilcoxon, Mann-Whitney, Pearson¿s or Spearman¿s Correlations and linear regression were applied as indicated, with significance level of 5%. The results showed no statistical differences between genders for any of the variables (p>0.05). There was statistical significant increase in muscle thickness from relaxation to clenching; between bite force and masseter muscle thickness both during clenching and relaxation from the first to the second evaluation; the temporalis muscle was thicker in before the placement of the prosthetic device (p<0.05), which did not happen for the contracted temporalis. There were not correlations between facial proportions and muscle thickness or bite force (p>0.05). Considering the body variables, there was a significant correlation between masseter muscle thickness during relaxation and body height in the first evaluation, and between masseter muscle thickness (both contracted and relaxed) and all the body variables in the second evaluation (p<0.05). In relation to the temporalis muscle, it was found a significant correlation between the contracted muscle and height in the first evaluation, and between the relaxed muscle and weight in the second evaluation (p<0.05). In relation to the bite force, there was only a correlation with body height in the second evaluation (p<0.05). Within the limitations of this study, it can be concluded that the removable dental prosthesis influenced the morphology of the muscles, determining an increase in muscle thickness, and the function, increasing the bite force / Mestrado / Odontopediatria / Mestre em Odontologia
28

Função mastigatoria em crianças apos a reabilitação protetica removivel bucal / Masticatory function in children after oral rehabilitation

Gambareli, Flavia Riqueto 24 February 2006 (has links)
Orientador: Maria Beatriz Duarte Gavião / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T08:16:33Z (GMT). No. of bitstreams: 1 Gambareli_FlaviaRiqueto_M.pdf: 685304 bytes, checksum: 895caadd40aaa440b444f7b5a65c183a (MD5) Previous issue date: 2006 / Resumo: O objetivo deste trabalho foi avaliar a performance mastigatória, a atividade eletromiográfica dos músculos masseter e porção anterior do temporal e a mastigação de alimentos de diferentes consistências em crianças na fase de dentição mista, com perda precoce de dentes decíduos posteriores, antes e após reabilitação protética. Para tanto, o estudo foi composto por três capítulos. No capítulo 1, intitulado Influence of measurement technique, test food, teeth and muscle force interactions in masticatory performance evaluation, realizou-se a revisão de literatura sobre performance mastigatória e discorreu-se sobre as variáveis influenciadoras. A revisão mostrou que a performance mastigatória tem sido amplamente avaliada e associada às variáveis morfológicas e funcionais do sistema mastigatório. No capítulo 2, intitulado Masticatory performance before and after oral rehabilitation in children, avaliou-se a performance mastigatória com alimento teste artificial. No capítulo 3, intitulado The influence of oral rehabilitation on muscle activity and chewing behavior in partially edentulous children, avaliou-se a atividade eletromiográfica dos músculos masseter e porção anterior do temporal e o comportamento mastigatório com alimentos de diferentes consistências. Avaliou-se também as variáveis corporais, peso e altura em ambos os capítulos. A performance mastigatória foi avaliada através da mastigação de um material à base de silicona, utilizando o sistema de peneiragem fragmentada para determinar o tamanho das partículas após mastigação. Para o registro eletromiográfico, foram utilizados o sistema de aquisição de sinais (EMG System do Brasil Ltda.) e o software Aqdados ¿ versão 5.0 da Lynx Eletrônica Ltda. O sinal eletromiográfico foi captado em contração voluntária máxima bilateral tendo o material Parafilm entre os molares e em mastigação habitual com alimento teste artificial. Os alimentos utilizados para avaliação da mastigação foram: goma de mascar (Trident tutti fruit, Adams), cenoura crua, queijo polenghi, banana nanica, torrada industrializada. Na análise dos dados do segundo e terceiro capítulos utilizou-se o teste de Shapiro-Wilk para verificação da normalidade da distribuição dos dados. Os Testes t pareado, Wilcoxon, Kruskal-Wallis e post hoc Dun, Correlação de Pearson e Spearman e regressão linear foram aplicados quando indicados, com nível de significância de 5%. Os resultados mostraram que não houve diferença estatística entre os sexos para nenhuma das variáveis (p>0.05). Houve um decréscimo significativo para o tamanho da partícula mediana antes e após 6 meses da instalação do aparelho protético (p<0,001). A atividade muscular foi significativamente maior na segunda avaliação durante a mastigação do alimento artificial (p<0,05). Considerando as variáveis corporais, houve correlação negativa significativa entre performance mastigatória, altura e peso na primeira sessão de exames (p<0,05), e não houve correspondentes correlações na segunda sessão de exames (p>0,05). Houve diferenças significativas no número de ciclos mastigatórios até a deglutição, duração da mastigação e a quantidade de alimento ingerida tanto para os alimentos duros quanto macios nas duas avaliações. A prótese parcial removível influenciou os aspectos funcionais dos músculos, determinando melhora da eficiência mastigatória e aumento da atividade muscular / Abstract: The aim of this study was to evaluate the masticatory performance, the electromyographic activity of the masseter and temporal anterior muscles and the chewing of foods of different consistency in children in the phase of mixed dentition, with early loss of posterior deciduous teeth, before and six months after oral rehabilitation with removable dental prosthesis. Three chapters compose the study. In chapter 1, entitled Influence of measurement technique, test food, teeth and muscle force interactions in masticatory performance evaluation, a review of the pertinent literature about masticatory performance was done, and the influencing variables were discussed. The review showed that masticatory performance has been widely evaluated and associated to the morphological and functional variables of the masticatory system. The second chapter entitled Masticatory performance before and after oral rehabilitation in children evaluated the masticatory efficiency with artificial test food. The third chapter entitled The influence of oral rehabilitation on muscle activity and chewing behavior in partially edentulous children evaluated the electromyographic activities of the masseter and temporal anterior muscles and the chewing of foods of different consistency. Also, it was evaluated the body variables, weight and height, in these two chapters. The masticatory performance was evaluated by the mastication of a silicone impression material, using the fragmented sieving system to determine the size of the chewed particles. For the electromyographic record, were used the system of acquisition of signs (EMG System of Brazil Ltd.) and software Aqdados-version 5.0 of Lynx Eletrônica Ltd. The electromyographic sign was captured in maximum bilateral voluntary contraction having the Parafilm material among the molars and in habitual mastication with artificial tests food. The foods for the chewing evaluation were: chewing gum raw carrot, polenghi cheese, banana and industrialized toast. For data analysis in the second and the third chapters, the normality of the distributions was assessed by the Shapiro-Wilks W-test. The t paired tests, Wilcoxon, Kruskal-Wallis and pos hoc Dun, Pearson¿s or Spearman¿s Correlations and linear regression were applied as indicated, with significance level of 5%. The results showed no statistical differences between genders for any of the variables (p>0.05). There was a significant decrease in the median particle size from first to second evaluation (p=0.000). The muscle activity was significantly greater on the second evaluation during the chewing of the artificial food (p<0.05). Considering the body variables, there was a significant negative correlation between masticatory efficiency, body height and weight in the first session of exams. After 6 months of the placement of the prosthesis no significant correlations were found for these variables (p<0.05). It was observed significant differences in number of cycles until swallowing, chewing duration and amount of food ingested for the soft and hard foods, at the two evaluations. Within the limitations of this study, it can be concluded that the removable dental prosthesis influenced the function of the muscles, determining an increase in the masticatory efficiency and an increasing in the muscle activity. It was considered that the body alterations could have been consequences of the enhancement in the masticatory function determined by the oral rehabilitation / Mestrado / Odontopediatria / Mestre em Odontologia
29

Ispitivanje biokompatibilnosti i mehaničkih karakteristika polimera za bazu zubne proteze / The investigation of biocompatibility and mechanical properties of denture base resins

Potran Michal 05 November 2015 (has links)
<p>U uvodnom delu doktorske disertacije opisuje se kompleksnost problematike kori&scaron;ćenja polimera za bazu zubne proteze, sa osvrtom na njihove op&scaron;te osobine, stepen biokompatibilnosti i njihove mehaničke karakteristike. Detaljno je opisana problematika ispitivanja stomatolo&scaron;kih materijala i napravljeno je poređenje i korelacija između in vitro i in vivo načina ispitivanja biokompatibilnosti. Drugi deo obuhvata ispitivanje čvrstoće polimera za bazu zubne proteze i analizu uticaja osobina materijala u odnosu na biolo&scaron;ku sredinu u kojoj obavljaju svoju funkciju, i u odnosu na sile kojima su tokom funkcije materijali izloženi. Cilj doktorske disertacije je utvrđivanje stepena biokompatibilnosti i mehaničkih karakteristika toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata za bazu zubne proteze. Istraživanje je obuhvatilo 3 komercijalna materijala iz grupe akrilata, koji se razlikuju po hemijskom sastavu i načinu polimerizacije. Ispitivanje biokompatibilnosti rađeno je u in vitro i in vivo uslovima. Ispitivanje na ćelijskim kulturama obuhvatalo je dve ćelisjke linije (MRC 5 i L929) sa dva načina kontakta između ćelija i materijala (direktan, indirektan) i dva načina određivanja biolo&scaron;kog ishoda (MTT test, Agar difuzioni test). Istraživanje urađeno in vivo obuhvatalo je test subkutane implantacije, na animalnom modelu pacova, i test iritacije oralne sluzokože na animalnom modelu hrčka. Oba testa rađena su u skladu sa standardom ISO 10993. Cilj in vivo istraživanja bio je ispitivanje reakcije tkiva na implantirani materijal, računajući i zavr&scaron;nu integraciju ili dezintegraciju implantiranog materijala. Prednost in vivo istraživanja nalazi seu analizi uticaja materijala na sterilno živo tkivo, uz praćenje imunolo&scaron;ke reakcije, kao dopuna prethodnom istraživanju na ćelijskim kulturama. Dopunski deo in vivo ispitivanja biokompatibilnosti određen je prema kliničkoj upotrebi ispitivanih materijala, zbog čega je odabran test oralne iritacije sluzokože. Sluzokoža bukalne kesice sirijskog hrčka sastoji se od pločasto slojvitog epitela sa orožavanjem, &scaron;to je predstavljao dobar model za ispitivanje polimera za bazu zubne proteze, po&scaron;to zubna proteza naleže na sluzokožu nepca i rezidualnog alveolarnog grebena koja takođe orožava. Drugi deo disertacije obuhvatao je ispitivanje mehaničkih karakteristika, pri čemu su urađeni test zatezne čvrstoće, test savojne čvrstoće, test čvrstoće loma i mikrotvrdoće, uz dopunsku analizu pratećih parametara. Rezultati ispitivanja biokompatibilnosti pokazali su da su testovi biokompatibilnosti osetljivi na upražnjeni metodolo&scaron;ki postupak. Ispitivanjem na ćelijskim kulturama nisu utvrđene značajne razlike u citotoksičnosti između toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata. Takođe, rezultati su se razlikovali u odnosu na tip ćelijske kulture i način provere biolo&scaron;kog ishoda, &scaron;to se slaže sa prethodnim navodima o kompleksnoj problematici njihovog međusobnog poređenja. Ispitivanjem biokompatibilnosti subkutanom implantacijom praćen je inflamatorni odgovor tkiva u vremenskom intervalu od 90 dana. Reakcija organizma na implantirani materijal posmatrana je kroz ćelijske i tkivne parametre, u skladu sa ISO 10993. Dodatno je urađena i analiza hrapavosti implantiranih materijala. Histolo&scaron;kom analizom utvrđena je razlika u inflamatornom odgovoru u odnosu na kori&scaron;ćeni materijal, kao i prema vremenskom intervalu implantacije. Test oralne iritacije sluzokože nije se pokazao kao dovoljno senzitivan za ispitivanje ovih vrsta materijala. Ispitivanjem mehaničkih karakteristika utvrđene su razlike između toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata. Najveći stepen čvrstoće utvrđen je kod toplopolimerizujućih akrilata dok je najveća konzistentnost rezultata bila u grupi termoplastičnih akrilata. Prezentovano istraživanje predstavlja prvu detaljnu analizu biokompatibilnosti i mehaničkih karaktestistika polimera za bazu zubne proteze.</p> / <p>The introduction describes the complexity of use of denture base materials, with regard to their general characteristics, biocompatibility and mechanical properties. Issues related to the testing of dental materials is described in detail and comparison is made between in vitro and in vivo methods of biocompatibility testing. The second part further covers the determination of strength of previously used materials, in relation to biological environment in which their function is conducted and in relation to the influence of masticatory forces which can contribute to their mechanical failure. The aim of the presented research was to assess the degree of biocompatibility and mechanical properties of cold curing, hot curing and thermoformed denture base materials. The research included three denture base materials, which differed according to their chemical composition and polymerization protocols. The biocompatibility testing was carried out in in vitro and in vivo conditions. The in vitro experiments covered two different cell lines (MRC 5 human lung fibroblasts and L929 mouse fibroblasts) with two types of contact (direct, indirect) and two different types of quantification of biological outcome (MTT assay and Agar overley test). The in vivo assessment of biocompatibility covered the subcutaneous implantation test, on the animal model of Wistar rat, and oral mucosa irritation test, on the animal model of sirian hamster. Both tests were conducted according to the ISO 10993. The aim of the in vivo investigation was to evaluate tissue reactions to the implanted materials, including the final integration or disintegration of the tested materials. The advantage of in vivo investigation included the possibility of monitoring the materials influence on living tissues, with the analysis of imunological response as an addition to the previously conductedresearchon cell cultures. The supplemental part of in vivo investigation was chosen according to the clinical use of the tested materials, which included the oral mucosa irritation test.The mucosa of hamster buccal pouch consists of stratified squamos epithelium, which is considered to be an adequate replacement for the human denture supporting tissues, which also consist of the same type of epithelium. The second part of thesis includes the determination of mechanical properties of denture base materials. It consists of four types of tests: tensile strength test, bending strength test, fracture toughness test and microhardness tests, followed by the analysis of corresponding parameters. The results of the biocompatibility tests showed that the biological outcome of the applied method is highly depended on the methodological procedure. The investigation conducted in vitro, on two different cell lines, did not show significant difference in cytotoxicity between hot curing, cold curing and thermoformed denture base materials. Also, the results were influenced by the type of cell culture and the evaluation method of biological outcome, which agrees with the previous allegations about the complexicity of their mutual comparison. The subcutaneous implantation test covered the inflammatory response in the time period of 90 days. The organism reaction to the implanted material was determined through the cell and tissue parameters of organism response, evaluation of which was conducted according to the ISO 10993. Additionally, the surface roughness of the implanted specimens of materials was also measured. The inflammatory response of the ogranism was influenced by the type of the implanted material and the time interval of implantation. The oral mucosa irritation test has proven not to be sufficiently sensitive for testing of this type of materials. Testing of the mechanical properties od denture base materials, revealed the difference between the cold curing, hot curing and thermofomed denture base materials. The highest strength was observed in hot curing materials, while the highest consistency of the results was observed in thermoformed resins. The presented investigation presents the first detail analysis of the biocompatibility and mechanical properties of the denture base materials, and as such presents a novelty in the field of dental materials characterization.</p>
30

Estudo comparativo entre um novo método de transferência de planos guias no preparo de boca para Próteses Parciais Removíveis e outras duas técnicas / Comparative study between a new method for tranferring guide planes on mouth preparation for Removable Partial Denture and two other techniques

Yamaguchi, Cláudio Akira 18 August 2011 (has links)
A confecção de uma prótese parcial removível exige a correta determinação do eixo de inserção e, consequentemente, o preparo cuidadoso de planos guias para satisfazer os princípios de retenção e estabilidade. Entretanto, grande parte dos profissionais negligencia esta etapa, seja por desconhecimento de sua importância, dificuldade técnica, quantidade limitada de opções cientificamente comprovadas de seus resultados, ou pela aparente e ilusória economia de tempo e de trabalho que sua realização possa tomar. Então, em função do número limitado de técnicas eficientes para transferência de planos guias e da necessidade de um método que otimize o tempo dos profissionais de forma prática e didática, o presente estudo buscou introduzir uma nova maneira de transferir os planos guias. A nova técnica consiste na utilização de uma placa de vacuum-form (PV), comparando-a com preparos realizados em delineador e com duas outras técnicas pré-existentes: à mão livre (ML) e coroas-guia (CG), analisando sua eficácia e precisão. Réplicas idênticas (n=44) de um modelo de gesso representativo da arcada inferior foram divididas em 11 grupos, com 4 modelos cada. Cada um dos onze estudantes de Odontologia recebeu 4 modelos - em um deles os planos guias já tinham sido previamente preparados com delineador, os quais serviram apenas de referência para que fossem empregados os outros métodos. As diferenças angulares dos planos guias nos 44 modelos, nos sentidos ântero-posterior, látero-lateral e cruzado foram mensuradas por meio de uma máquina de medição por coordenadas. A análise de variância para medidas repetidas e o Teste de Comparações Múltiplas (método de Tukey) revelaram que tanto no sentido látero-lateral, como na avaliação cruzada, houve diferença significativa na média dos preparos feitos no delineador em relação a todas as outras técnicas. No entanto, não foram identificadas diferenças importantes entre os três métodos. Para a avaliação ântero-posterior, verificou-se diferença relevante somente entre os preparos feitos no delineador e CG, o que não foi detectado entre ML, PV e delineador. Observou-se também, que os preparos obtidos com delineador apresentaram variações angulares próximos de zero, indicando paralelismo quase absoluto e que os planos guias preparados nesse dispositivo demonstraram média e variabilidade menores que os outros métodos. As demais técnicas (ML, CG e PV) se comportaram de forma estatistica semelhante, exceto no sentido ântero-posterior, onde a CG apresentou maior variação angular. Concluiu-se que a técnica proposta apresentou resultados satisfatórios em relação aos padrões adotados neste estudo, quando comparada às demais técnicas e ao delineador. Portanto, a mesma pode ser considerada viável, já que sua utilização oferece uma confecção de próteses removíveis de forma mais criteriosa, atendendo às necessidades profissionais, em termos de facilidade e tempo gasto em sua execução. / The confection of a removable partial denture requires accurate determination of the path of insertion and consequently, the careful preparation of guide planes to meet the principles of retention and stability. However, a great number of professionals neglect this step because of unconsciousness of its importance, or technical difficulty, or limited options of techniques or because of apparent and illusory saving of time and work. Due to the limited number of proven effective techniques for guide planes preparation and the need of an effective method for optimizing time of dental surgeons in a clear and practical way, this present study aimed the introduction of a new technique for transferring guide planes. The new technique consists on the use of a vacuum form splint (VF). To measure its efficiency and accuracy it was compared with the preparations carried out in a dental surveyor and with two other pre-existing techniques: freehand (FH) and acrylic resin guide crown (GC). Identical replicas (n=44) of a gypsum model representing a dental lower arch were divided into 11 groups of four. Each of the eleven dental students received four models - in one of the models, the guide planes were previously prepared with the surveyor to be used as a reference for the application of the three transfer techniques in the other three remaining models. The angular differences of the the prepared guide planes on the 44 models were measured by a coordinate measuring machine in the anteroposterior, laterolateral and crossed views. The Analysis of Variance and Tukey method revealed that, for the laterolateral evaluation and crossed evaluation, significant differences were found in the average of the preparations obtained by the surveyor in relation to all other techniques. There were no significant differences among the three techniques. Anteroposterior evaluation showed significant difference between the average of the preparations made by the surveyor and by the GC, which was not observed between the FH and PV groups compared to the surveyor. It was also found that the angular variation obtained by preparations using the surveyor was close to zero degree, indicating almost absolute parallelism. The FH, GC and VF techniques were statistically similar, except for the anteroposterior evaluation. In the anteroposterior evaluation the GC presented higher angular variation. It was concluded that the proposed technique showed satisfactory results concerning the adopted standards in the present study when compared with the preparations made by other techniques and the surveyor. Thus, the VF technique can be considered viable, since it improves the quality of the Removable Partial Denture and meets the professional needs, saving time in the procedures.

Page generated in 0.317 seconds