• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Transformadas wavelet aplicadas à proteção diferencial de transformadores de potência / Wavelet transform applied to differential protection in power transformers

Jorge, David Calhau 28 March 2003 (has links)
Transformadores de potência são dispositivos que requerem atenção especial devido a sua grande importância ao sistema elétrico de potência no qual ele está conectado. Geralmente relés diferenciais são utilizados como proteção primária em transformadores de potência. Nestes relés, a corrente diferencial é comparada com um nível de ajuste e caso ocorra uma falta interna, o transformador deverá ser desconectado do restante do sistema. Entretanto, a simples detecção da presença de uma corrente diferencial não é suficiente para distinguir faltas internas de outras situações que também podem produzir tal corrente. Tais situações surgem durante a energização dos transformadores, devido a saturação dos transformadores de corrente, entre outras, as quais podem resultar em uma incorreta atuação da proteção. Uma rápida e correta discriminação entre faltas internas e outras situações é um dos desafios da moderna proteção de transformadores de potência. A respeito da identificação de faltas internas ou situações de energização, além da mencionada lógica diferencial é acrescentado uma subrotina baseada na restrição de harmônicas. Neste método, a corrente de energização é reconhecida através da presença de uma segunda harmônica obtida por filtros de Fourier. No entanto, o método de filtragem pode algumas vezes retardar a operação da proteção. Além disto, uma componente de segunda harmônica pode também estar presente durante uma falta interna. Este trabalho propõe a utilização da transformada Wavelet - uma poderosa ferramenta matemática - empregada como um meio rápido e eficiente de analisar as formas de onda de transformadores de potência e como uma alternativa a tradicional transformada de Fourier. Os sinais das correntes diferenciais são processados pelas transformadas discretas Wavelet, visando obter uma discriminação entre ambas situações (energização e falta). Um nível de limiar é utilizado após a decomposição Wavelet do sinal para discriminar entre as situações descritas. A janela de dados utilizada para este propósito pode ser variada. Para testar o algoritmo proposto, as simulações de energização e falta foram implementadas, utilizando o programa ATP (\"Alternative Transient Program\"). Em situações onde a janela de dados é reduzida para 1/4 de ciclo o critério de discriminação pode ser otimizado utilizando a transformada discreta de Wavelet auxiliada com técnicas de reconhecimento de padrões. Este trabalho apresenta a utilização de redes neurais artificiais para tal finalidade como exemplo. Resultados encorajadores são apresentados sobre a capacidade de discriminação para as situações descritas assim como a rapidez de resposta quando comparados aos métodos tradicionais. / Power transformers are devices that require special maintenance and care due to their importance to the electrical system to which they are connected. Generally, differential relays are used for the primary protection of large transformers. In such relays, differential currents are compared to a threshold and in the case of an internal fault, the transformer should be disconnected from the rest of the system. However, a simple detection of a differential current is not sufficient to distinguish internal faults from other situations that also produce such a current. Some of these situations appear during transformer energization (inrush currents), CT (current transformer) saturation, among others, which can result in an incorrect trip. A correct and fast distinction of internal faults from the other situations mentioned is one of the challenges for modern protection of power transformers. Concerning the identification of internal faults as opposed to inrush currents, the approach tarditionally used is the aforementioned differential logic together with harmonic restraint. In this method, transformer inrush current due to energization is recognized on the basis of second harmonic components obtained by Fourier filters. However, the filtering method can sometimes delay the protection process. In addition to this, a second harmonic component can also be present during internal faults. This work proposes Wavelet transform - a powerful mathematical tool - employed as a fast and effective means of analyzing waveforms from power transformers, as an alternative to the traditional Fourier transform. The differential signals are processed by discrete Wavelet transform to obtain the discrimination between both situations (inrush and fault). A threshold level is utilized after the Wavelet decomposition to discriminate the situations describeb. The time window used for such purpose can be varied. In order to test proposed algorithm, simulations of fault and inrush currents in a power transformer were implemented using ATP ( \"Alternative Transient Program\") software. When the time window is reduced to only 1/4 of the cycle the discrimination criteria should be optimized using a pattern recognition technique to aid the Discrete Wavelet transform. This study shows as a sample for this purpose the use of artificial neural networks. Very encouraging results are presented concerning the capacity of discrimination of the described situations as well as the speed of response when compared to the traditional method.
2

Transformadas wavelet aplicadas à proteção diferencial de transformadores de potência / Wavelet transform applied to differential protection in power transformers

David Calhau Jorge 28 March 2003 (has links)
Transformadores de potência são dispositivos que requerem atenção especial devido a sua grande importância ao sistema elétrico de potência no qual ele está conectado. Geralmente relés diferenciais são utilizados como proteção primária em transformadores de potência. Nestes relés, a corrente diferencial é comparada com um nível de ajuste e caso ocorra uma falta interna, o transformador deverá ser desconectado do restante do sistema. Entretanto, a simples detecção da presença de uma corrente diferencial não é suficiente para distinguir faltas internas de outras situações que também podem produzir tal corrente. Tais situações surgem durante a energização dos transformadores, devido a saturação dos transformadores de corrente, entre outras, as quais podem resultar em uma incorreta atuação da proteção. Uma rápida e correta discriminação entre faltas internas e outras situações é um dos desafios da moderna proteção de transformadores de potência. A respeito da identificação de faltas internas ou situações de energização, além da mencionada lógica diferencial é acrescentado uma subrotina baseada na restrição de harmônicas. Neste método, a corrente de energização é reconhecida através da presença de uma segunda harmônica obtida por filtros de Fourier. No entanto, o método de filtragem pode algumas vezes retardar a operação da proteção. Além disto, uma componente de segunda harmônica pode também estar presente durante uma falta interna. Este trabalho propõe a utilização da transformada Wavelet - uma poderosa ferramenta matemática - empregada como um meio rápido e eficiente de analisar as formas de onda de transformadores de potência e como uma alternativa a tradicional transformada de Fourier. Os sinais das correntes diferenciais são processados pelas transformadas discretas Wavelet, visando obter uma discriminação entre ambas situações (energização e falta). Um nível de limiar é utilizado após a decomposição Wavelet do sinal para discriminar entre as situações descritas. A janela de dados utilizada para este propósito pode ser variada. Para testar o algoritmo proposto, as simulações de energização e falta foram implementadas, utilizando o programa ATP (\"Alternative Transient Program\"). Em situações onde a janela de dados é reduzida para 1/4 de ciclo o critério de discriminação pode ser otimizado utilizando a transformada discreta de Wavelet auxiliada com técnicas de reconhecimento de padrões. Este trabalho apresenta a utilização de redes neurais artificiais para tal finalidade como exemplo. Resultados encorajadores são apresentados sobre a capacidade de discriminação para as situações descritas assim como a rapidez de resposta quando comparados aos métodos tradicionais. / Power transformers are devices that require special maintenance and care due to their importance to the electrical system to which they are connected. Generally, differential relays are used for the primary protection of large transformers. In such relays, differential currents are compared to a threshold and in the case of an internal fault, the transformer should be disconnected from the rest of the system. However, a simple detection of a differential current is not sufficient to distinguish internal faults from other situations that also produce such a current. Some of these situations appear during transformer energization (inrush currents), CT (current transformer) saturation, among others, which can result in an incorrect trip. A correct and fast distinction of internal faults from the other situations mentioned is one of the challenges for modern protection of power transformers. Concerning the identification of internal faults as opposed to inrush currents, the approach tarditionally used is the aforementioned differential logic together with harmonic restraint. In this method, transformer inrush current due to energization is recognized on the basis of second harmonic components obtained by Fourier filters. However, the filtering method can sometimes delay the protection process. In addition to this, a second harmonic component can also be present during internal faults. This work proposes Wavelet transform - a powerful mathematical tool - employed as a fast and effective means of analyzing waveforms from power transformers, as an alternative to the traditional Fourier transform. The differential signals are processed by discrete Wavelet transform to obtain the discrimination between both situations (inrush and fault). A threshold level is utilized after the Wavelet decomposition to discriminate the situations describeb. The time window used for such purpose can be varied. In order to test proposed algorithm, simulations of fault and inrush currents in a power transformer were implemented using ATP ( \"Alternative Transient Program\") software. When the time window is reduced to only 1/4 of the cycle the discrimination criteria should be optimized using a pattern recognition technique to aid the Discrete Wavelet transform. This study shows as a sample for this purpose the use of artificial neural networks. Very encouraging results are presented concerning the capacity of discrimination of the described situations as well as the speed of response when compared to the traditional method.
3

Differential relay model development and validation using real time digital simulator

Vijapurapu, Vamsi Krishna 13 December 2008 (has links)
The protection system in a shipboard power system plays a vital role in detecting the fault conditions, isolating the faulted zone and preventing the fault propagation into other vital sections onboard the ship. The protection system should be able to remove faults and restore the service to all the vital loads rapidly. In order to design the protection system, preliminary hardware-in-the-loop testing is done using bus differential relay hardware and a Real Time Digital Simulator (RTDS). In this thesis work, based upon the functionalities of the relay hardware the software differential relay model is designed and simulated using the RSCAD Version 2.00 software suite and RTDS. The software differential relay model developed in RSCAD was tested on a terrestrial power system and a shipboard power system test case for various fault conditions, and its functionalities are validated based upon the hardware-in-the-loop test results.
4

Proteção diferencial digital de linhas de transmissão com compensação série / Digital differential protection of series compensated transmission lines

Navarro, Eduardo Coelho 22 August 2002 (has links)
A proteção diferencial é o esquema preferido para proteção de equipamentos e linhas de transmissão. A proteção diferencial exige que informações de todos terminais de zona sob proteção sejam usados para calcular a corrente diferencial. Se esta corrente excede um determinado limite significa que uma falta pode existir na zona protegida. Tais cálculos devem ser executados em cada terminal, consequentemente deve existir um rápido canal de comunicação entre todos os terminais de linha. Este trabalho apresenta o desenvolvimento do algoritmo de uma proteção diferencial digital de linhas de transmissão com compensação em série. O algoritmo proposto foi implementado em Matlab e foi testado com os mais diferentes tipos de faltas simuladas no programa ATP (Alternative Transients Program). Os resultados comprovam o correto funcionamento do algoritmo. O uso de tecnologias atuais de sincronização por GPS (Global Positioning System) e transmissão de dados em banda larga, resolvem antigos problemas da implementação de proteções diferenciais em linhas de transmissão. / The differential protection is the preferred scheme to protect equipment and transmission lines. The differential protection needs information from all terminals of a protected zone to be used to calculate the differential current. If the current exceeds the threshold level, it means that a fault may exist in the protected zone. These computations must be made on each terminal, consequently a fast communication channel connecting all terminals must exist. This work presents the development of a digital differential protection algorithm for series compensated transmission lines. The algorithm was implemented in Matlab and it was tested with the most different variety of faults simulated with ATP (Alternative Transients Program) software. The results proved the correct operation of the algorithm. The use of modern technologies of synchronization such as GPS (Global Positioning System) and data transmission by wide band solved old problems presented by the implementation of differential protection in transmission lines.
5

Proteção diferencial digital de linhas de transmissão com compensação série / Digital differential protection of series compensated transmission lines

Eduardo Coelho Navarro 22 August 2002 (has links)
A proteção diferencial é o esquema preferido para proteção de equipamentos e linhas de transmissão. A proteção diferencial exige que informações de todos terminais de zona sob proteção sejam usados para calcular a corrente diferencial. Se esta corrente excede um determinado limite significa que uma falta pode existir na zona protegida. Tais cálculos devem ser executados em cada terminal, consequentemente deve existir um rápido canal de comunicação entre todos os terminais de linha. Este trabalho apresenta o desenvolvimento do algoritmo de uma proteção diferencial digital de linhas de transmissão com compensação em série. O algoritmo proposto foi implementado em Matlab e foi testado com os mais diferentes tipos de faltas simuladas no programa ATP (Alternative Transients Program). Os resultados comprovam o correto funcionamento do algoritmo. O uso de tecnologias atuais de sincronização por GPS (Global Positioning System) e transmissão de dados em banda larga, resolvem antigos problemas da implementação de proteções diferenciais em linhas de transmissão. / The differential protection is the preferred scheme to protect equipment and transmission lines. The differential protection needs information from all terminals of a protected zone to be used to calculate the differential current. If the current exceeds the threshold level, it means that a fault may exist in the protected zone. These computations must be made on each terminal, consequently a fast communication channel connecting all terminals must exist. This work presents the development of a digital differential protection algorithm for series compensated transmission lines. The algorithm was implemented in Matlab and it was tested with the most different variety of faults simulated with ATP (Alternative Transients Program) software. The results proved the correct operation of the algorithm. The use of modern technologies of synchronization such as GPS (Global Positioning System) and data transmission by wide band solved old problems presented by the implementation of differential protection in transmission lines.

Page generated in 0.0683 seconds