• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design And Implementation Of Advanced Pulse Width Modulation Techniques And Passive Filters For Voltage Source Inverter Driven Three-phase Ac Motors

Cetin, Nebi Onur 01 July 2010 (has links) (PDF)
Advanced pulse width modulation (PWM) techniques such as space vector PWM, active zero state PWM, discontinuous PWM, and near state PWM methods are used in three-phase AC motor drives for the purpose of obtaining low PWM current ripple, wide voltage linearity range, and reduced common mode voltage (CMV). In some applications, a filter is inserted between the inverter and the motor for the purpose of reducing the stresses in the motor. The motor current PWM ripple components, terminal voltage overshoots, shaft voltage, and bearing currents, etc. can all be reduced by means of PWM techniques and passive filters. Various PWM techniques and passive filter types exist. This thesis studies the combinations of PWM techniques and filters and evaluates the performance of the motor drive in terms of the discussed stresses in the motor. PWM techniques are reviewed, a generalized algorithm for the implementation of PWM techniques is developed, and implementation on a 4 kW rated drive is demonstrated. Filter types are studied, among them the common mode inductor and the pure sine filter (PSF) configurations are investigated in detail. Filters are designed and their laboratory performance is evaluated. In the final stage the advanced PWM techniques and filters are combined, the incompatibility problem of discontinuous PWM methods with the PSF is illustrated. A cure based on rate of change limiter is proposed and its feasibility proven in the laboratory experiments. With the use of the proposed PWM algorithm and PSF, a motor drive with ideal DC to AC conversion stage (DC to pure sine) is achieved and its performance is demonstrated in the laboratory.
2

Corrente de fuga em inversores monofásicos sem transformador para conexão de sistemas fotovoltaicos à rede de distribuição de energia elétrica: análise e proposta de filtro passivo integrado de modo comum e diferencial. / Leakage current in single-phase transformerless inverters for the connection of photovoltaic systems to the distribution grid: analysis and proposal of an integrates common and differential mode passive filter.

Ricardo Souza Figueredo 21 May 2015 (has links)
Este trabalho apresenta um estudo sobre a corrente de fuga de modo comum em inversores monofásicos sem transformador utilizados para a conexão de sistemas fotovoltaicos (FV) à rede de distribuição de energia elétrica. O estudo se concentra em inversores do tipo fonte de tensão que empregam a topologia em ponte completa. A partir da adequada modelagem do sistema (rede, conversor e módulo fotovoltaico) identifica-se e quantifica-se a contribuição das tensões de modo comum e modo diferencial para a corrente de fuga. Conclui-se que a tensão de modo comum de alta frequência produzida pelo inversor, que depende da estratégia de modulação por largura de pulso (PWM Pulse Width Modulation) empregada, fornece a maior contribuição para produção da corrente de fuga. Esse estudo mostra que os inversores sem transformador, com topologia em ponte completa e modulação que produz tensão de saída com três níveis, necessitam de medidas adicionais para a minimização da corrente fuga quando aplicados em sistemas fotovoltaicos conectados à rede. Algumas soluções propostas na literatura para a minimização da corrente de fuga baseadas em topologias modificadas e filtros de modo comum são listadas e discutidas. Neste trabalho é proposto um filtro integrado de modo comum e modo diferencial com amortecimento passivo de baixas perdas, para minimizar a corrente de fuga produzida por um inversor monofásico sem transformador. Um exemplo de aplicação do filtro proposto é apresentado juntamente com seu procedimento de projeto, resultados de simulação e experimentais que validam a proposta. Além disso, a influência da variação da indutância da rede elétrica e da capacitância parasita do sistema fotovoltaico no comportamento do filtro proposto é analisada. A influência da variação da indutância da rede no comportamento do sistema de controle e o impacto da corrente de modo comum no projeto dos indutores do lado do conversor também são analisados. / This paper presents a study on the common mode leakage current in single-phase transformerless inverters for grid-connected photovoltaic (PV) systems. The study focuses on voltage source inverters (VSI) employing the full-bridge topology. The common mode and differential mode voltages that contribute to the leakage current are identified and quantified from the analysis of the system model (utility grid, converter and PV module). The system model analysis shows that the high frequency common mode voltage produced by the inverter, which depends on the Pulse Width Modulation (PWM) strategy, is the main source contributing to the leakage current. This work shows that transformerless inverters employing the full-bridge topology and a modulation strategy that produces a three-level output voltage require some leakage current minimization strategy when they are employed in grid-connected PV systems. Some solutions proposed in the literature for leakage current minimization based on modified topologies and common mode filters are listed and discussed. In this dissertation an integrated common and differential filter with low loss passive damping is proposed to minimize the leakage current produced by a single-phase transformerless PV inverter. An application example of the proposed filter is presented with design procedure, simulation and experimental results validating the proposal. Additionally, the influence of grid inductance and PV module parasitic capacitance variations on the behavior of the proposed filter is analyzed. The behavior of the control system considering the grid inductance variation and the impact of the common mode current on the converter side inductors design are also analyzed.
3

Corrente de fuga em inversores monofásicos sem transformador para conexão de sistemas fotovoltaicos à rede de distribuição de energia elétrica: análise e proposta de filtro passivo integrado de modo comum e diferencial. / Leakage current in single-phase transformerless inverters for the connection of photovoltaic systems to the distribution grid: analysis and proposal of an integrates common and differential mode passive filter.

Figueredo, Ricardo Souza 21 May 2015 (has links)
Este trabalho apresenta um estudo sobre a corrente de fuga de modo comum em inversores monofásicos sem transformador utilizados para a conexão de sistemas fotovoltaicos (FV) à rede de distribuição de energia elétrica. O estudo se concentra em inversores do tipo fonte de tensão que empregam a topologia em ponte completa. A partir da adequada modelagem do sistema (rede, conversor e módulo fotovoltaico) identifica-se e quantifica-se a contribuição das tensões de modo comum e modo diferencial para a corrente de fuga. Conclui-se que a tensão de modo comum de alta frequência produzida pelo inversor, que depende da estratégia de modulação por largura de pulso (PWM Pulse Width Modulation) empregada, fornece a maior contribuição para produção da corrente de fuga. Esse estudo mostra que os inversores sem transformador, com topologia em ponte completa e modulação que produz tensão de saída com três níveis, necessitam de medidas adicionais para a minimização da corrente fuga quando aplicados em sistemas fotovoltaicos conectados à rede. Algumas soluções propostas na literatura para a minimização da corrente de fuga baseadas em topologias modificadas e filtros de modo comum são listadas e discutidas. Neste trabalho é proposto um filtro integrado de modo comum e modo diferencial com amortecimento passivo de baixas perdas, para minimizar a corrente de fuga produzida por um inversor monofásico sem transformador. Um exemplo de aplicação do filtro proposto é apresentado juntamente com seu procedimento de projeto, resultados de simulação e experimentais que validam a proposta. Além disso, a influência da variação da indutância da rede elétrica e da capacitância parasita do sistema fotovoltaico no comportamento do filtro proposto é analisada. A influência da variação da indutância da rede no comportamento do sistema de controle e o impacto da corrente de modo comum no projeto dos indutores do lado do conversor também são analisados. / This paper presents a study on the common mode leakage current in single-phase transformerless inverters for grid-connected photovoltaic (PV) systems. The study focuses on voltage source inverters (VSI) employing the full-bridge topology. The common mode and differential mode voltages that contribute to the leakage current are identified and quantified from the analysis of the system model (utility grid, converter and PV module). The system model analysis shows that the high frequency common mode voltage produced by the inverter, which depends on the Pulse Width Modulation (PWM) strategy, is the main source contributing to the leakage current. This work shows that transformerless inverters employing the full-bridge topology and a modulation strategy that produces a three-level output voltage require some leakage current minimization strategy when they are employed in grid-connected PV systems. Some solutions proposed in the literature for leakage current minimization based on modified topologies and common mode filters are listed and discussed. In this dissertation an integrated common and differential filter with low loss passive damping is proposed to minimize the leakage current produced by a single-phase transformerless PV inverter. An application example of the proposed filter is presented with design procedure, simulation and experimental results validating the proposal. Additionally, the influence of grid inductance and PV module parasitic capacitance variations on the behavior of the proposed filter is analyzed. The behavior of the control system considering the grid inductance variation and the impact of the common mode current on the converter side inductors design are also analyzed.

Page generated in 0.1241 seconds