• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 1
  • Tagged with
  • 12
  • 12
  • 12
  • 8
  • 8
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Rocket Motor Diagnostics using Tunable Diode Laser Spectroscopy for Chemically Non-Reacting Air/Water Vapor Mixture in Internal Flow

Carleton, Wesley 20 December 2013 (has links)
This research is for the implementation of non-intrusive measurement techniques in the study of high temperature pipe flow. A low pressure, laboratory scale hybrid rocket motor simulator was built to achieve high temperatures with various gases. A quartz test section was designed, built, and implemented into the existing test setup to accommodate the laser beam of the existing Tunable Diode Laser Absorption Spectrometer (TDLAS) system which was designed to observe water vapor. A super-heated water vapor injector was designed to obtain the desired water vapor concentrations. Flow characteristics were simultaneously recorded using the existing TDLAS system and the DAQ system for temperatures for later comparison. A numerical study using a commercial CFD package was used to predict the flow characteristics at certain locations for experimental comparison. Based on this study, it is concluded that the TDLAS can be used to make real time temperature measurements of heated internal gas flows.
2

Tunable Diode Laser Absorption Spectroscopy Characterization of Impulse Hypervelocity CO2 Flows

Meyers, Jason 11 September 2009 (has links)
Tunable diode laser absorption spectroscopy using an external cavity diode laser operating in the infra-red has been developed to monitor CO2 in the freestream of the Longshot hypervelocity facility at the Von Karman Institute for Fluid Dynamics. The Longshot facility offers a unique European facility for ground testing and numerical validation applications, however, some of the traditional data rebuilding aspects are in question. A non-intrusive absorption sensor could significantly aid in improving the knowledge of freestream static values thereby improving the models used in data rebuilding and numerical simulation. The design of such a sensor also expands the spectroscopic capabilities of the Von Karman Institute. The absorption sensor is designed around the single P12 (00001)-(30013) rovibrational transition near 1.6µm (6218.09cm-1 specifically) which yields relatively weak direct absorption levels at about 3.5% per meter for typical Longshot freestream conditions. However, when handled carefully, adequate signal-to-noise can be acquired to exploit significant flow information. By being able to operate in this range, total sensor cost can be easily an a factor of two or more cheaper than sensors designed for the deeper infrared. All sensor elements were mounted to a compact portable optics bench utilizing single-mode optical fibers to allow for quick installation at different facilities by eliminating tedious optical realigning. Scans at 600Hz were performed over 20ms of the 40ms test time to extract core static temperature, pressure and velocity. These results are compared with the current state of the Longshot data rebuild method. The non-uniform flow properties of the shear layer and test cabin rested gas accumulation was of an initial concern. The temperature and density gradients along with significant radial velocity components could result in DLAS temperature, pressure and velocity that are significantly different than that of the target freestream inviscid core values. Fortunately, with the proper selection of the P12 rotational number, this effect could be more or less ignored as the higher temperature and lower density gas of this region is relatively transparent. Ultimately, acquired temperature and density were moderately accurate when compared to Longshot rebuilt results owing primarily to the baseline extraction which poses issues for such low absorption signals. However, the extracted velocity data are quite accurate. This is a definite puls for the sensor as the freestream enthalpy of cold hypersonic facilities is dictated primarily by the kinetic energy contribution. Being able to compare velocity gives insight to the level of vibration non-equilibrium in the flow. The velocity of the DLAS and the Longshot rebuild are quite close. This adds more weight to the argument that vibrational excitation is very low (if present at all) in the free stream and that the van de derWaals equation of state usage and constant specific heat assumption might be an adequate model for the data rebuild after all.
3

Determination of Flame Dynamics for Unsteady Combustion Systems using Tunable Diode Laser Absorption Spectroscopy

Hendricks, Adam Gerald 06 January 2004 (has links)
Lean, premixed combustion has enjoyed increased application due to the need to reduce pollutant emissions. Unfortunately, operating the flame at lean conditions increases susceptibility to thermoacoustic (TA) instability. Self-excited TA instabilities are a result of the coupling of the unsteady heat release rate of the flame with the acoustics of the combustion chamber. The result is large pressure oscillations that degrade performance and durability of combustion systems. Industry currently has no reliable tool to predict instabilities a priori. CFD simulations of full-scale, turbulent, reacting flows remain unrealizable. The work in this paper is part of a study that focuses on developing compact models of TA instabilities, i.e. acoustics and flame dynamics. Flame dynamics are defined as the response in heat release to acoustic perturbations. Models of flame dynamics can be coupled with models of combustor enclosure acoustics to predict TA instabilities. In addition, algorithms to actively control instabilities can be based on these compact models of flame dynamics and acoustics. The work outlined in this thesis aims at determining the flame dynamics model experimentally. Velocity perturbations are imparted on laminar and turbulent flames via a loudspeaker upstream of the flame. The response of the flame is observed through two measurements. Hydroxyl radical (OH*) chemiluminescence indicates the response in chemical reaction rate. Tunable Diode Laser Absorption Spectroscopy (TDLAS), centered over two water absorption features, allows a dynamic measurement of the product gas temperature. The response in product gas temperature directly relates to the enthalpy fluctuations that couple to the acoustics. Experimental frequency response functions of a laminar, flat-flame burner and a turbulent, swirl-stabilized combustor will be presented as well as empirical low-order models of flame dynamics. / Master of Science
4

Diagnostics and modelling of atmospheric pressure chemical vapour deposition reactors

Hehn, Martin Christoph January 2014 (has links)
In the manufacturing process of float glass often atmospheric pressure chemical vapour deposition (APCVD) reactors are integrated on-line for the deposition of functional thin solid films. Such functional films have applications in architectural glass, flat panel displays and solar cells. As glass moves downstream in the process, the thin film is deposited at temperatures between 500 to 700°C. The high temperatures make it difficult to monitor the deposition process and thin film quality control is commonly done at the end of the line or at lower temperatures. A time delay therefore exists between the point of thin film deposition and subsequent quality control, which can lead to large quantities of defective product being produced before faults are detected. It is therefore desirable to monitor in the APCVD reactor for rapid feedback of unexpected deviations from desired process conditions, reaction progress and fault detection. High uniformity of film properties across the substrate are important, but APCVD reactors are often empirically designed and the detailed chemical reaction mechanism is unknown. This leads to inefficient gas flow patterns and precursor utilization as well as difficulties in the design of new reactors. The APCVD deposition of tin oxide from the mono-butyl-tin tri-chloride (MBTC) is an example of such a process. Optical monitoring instruments in-situ and in-line on the APCVD reactor provided rapid feedback about process stability and progress non-invasively. Near infrared diode laser absorption spectroscopy (NIR-LAS) monitored the concentration of the reaction species hydrogen chloride (HCl) in-situ and spatially in the coating zone. A mid-infrared grating absorption spectrometer (IR-GAS) with novel pyro-electric array detector monitored the concentration of precursor entering the coating system simultaneously. In combination these instruments provide the means for rapid process feedback. Fourier transform infrared absorption spectroscopy (FTIR) was used to investigate the unknown decomposition pathway of the precursor to find the yet unknown key tin radical that initiates film growth. Stable species forming during MBTC decomposition over a temperature range of 170 to 760°C were investigated but the tin intermediate remains unknown. Computational fluid dynamics (CFD) is routinely employed in research and industry for the numerical simulation of CVD processes in order to predict reactor flow patterns, deposition rates, chemical species distribution or temperature profiles. Two and three dimensional models with complex geometries and detailed reaction models exist. A three dimensional computational fluid dynamics (CFD) model of the used APCVD reactor was built using the Fluent CFD software. The numerical simulation included a chemical model that predicted qualitatively the chemical species distribution of hydrogen chloride in the gas phase. This was confirmed through comparison with NIR-LAS results. Design shortcomings due to inefficient flow patterns were also identified. In combination the optical tools developed provide the means for safe and efficient manufacturing of thin films in APCVD reactors. CFD simulations can be used to increase precursor utilization and film uniformity in the development of new reactor designs.
5

Combustor Exhaust Temperature Nonuniformity Sensing Using Diode Laser Absorption

Palaghita, Tudor I. 12 February 2007 (has links)
This thesis describes the development of a sensing technique for temperature nonuniformity along the line of sight through combustion exhaust, geared for gas turbine applications. Tunable diode laser absorption spectroscopy is used to measure three absorption lines and compute a variable to characterize the level of temperature nonuniformity along the laser path. Nonuniformity information is obtained from one line of sight sensor because the absorption has a nonlinear dependence on temperature. This dependence is analyzed to determine the behaviour, shape, and response of absorption lines measured through mediums with nonuniform temperature profiles. Based on this analysis a new line selection process for nonuniformity sensing is developed. A sensor for temperature nonuniformity is proposed and demonstrated through computer simulations and experiments in the exhaust of a laboratory-scale combustor. The nonuniformity variable, U, is shown to monotonically track the level of temperature nonuniformity along the laser path. The capabilities of this sensing technique are determined based on a comprehensive analysis of errors and their effect on sensor performance. Methods to mitigate these errors are described, and the overall sensor capability is determined based on the characteristics of state of the art diode laser and absorption sensor technology. Such a sensor is capable of measuring minimum temperature deviations of 17% or more, which is well within the needed capabilities for industrial applications. Furthermore, the results and knowledge presented in this thesis apply to other absorption based sensing techniques.
6

Tunable diode laser trace gas detection with a vertical cavity surface emitting laser

Vujanic, Dragan Unknown Date
No description available.
7

Tunable diode laser trace gas detection with a vertical cavity surface emitting laser

Vujanic, Dragan 11 1900 (has links)
The nature of work conducted during the course of study towards a MSc degree focused on tunable diode laser absorption spectroscopy (TDLAS). This field involves the in-situ detection of gas constituents from low concentration samples. Specifically, I will focus on TDLAS systems utilizing practical optics, readymade electronics, and commercially available near infrared vertical cavity surface emitting lasers (VCSEL). In attempting to lower the minimum detectable concentrations of constituent gases, quantifying contributory noise sources is vital. Consequently, I seek to characterize principle noise sources of a prototypical TDLAS system in order to gain understanding of the limits that inhibit detection of trace gas concentrations. The noise sources which were focused on can be categorized as follows: source laser noise, optical noise, and detection noise. Through this work it was my goal to provide the means of achieving superior sensitivities.
8

Development of diode laser-based absorption and dispersion spectroscopic techniques for sensitive and selective detection of gaseous species and temperature

Lathdavong, Lemthong January 2011 (has links)
The main aim of this thesis has been to contribute to the ongoing work with development of new diode-laser-based spectroscopic techniques and metho­do­lo­gies for sensitive detection of molecules in gas phase. The techniques under scrutiny are tunable diode laser absorption spectrometry (TDLAS) and Faraday modulation spectrometry (FAMOS). Conventional distributed-feedback (DFB) tele­communication diode lasers working in the near-infrared (NIR) region have been used for detection of carbon monoxide (CO) and temperature in hot humid media whereas a unique frequency-quadrupled external-cavity diode laser producing mW powers of continuous-wave (cw) light in the ultra violet (UV) region have been used for detection of nitric oxide (NO). A methodology for assessment of CO in hot humid media by DFB-TDLAS has been developed. By addressing a particular transition in its 2nd overtone band, and by use of a dual-fitting methodology with a single reference water spectrum for background correction, % concentrations of CO can be detected in media with tens of percent of H2O (≤40%) at T≤1000 °C with an accuracy of a few %. Moreover, using an ordinary DFB laser working in the C-band, a technique for assessment of the temperature in hot humid gases (T≤1000 °C) to within a fraction of a percent has been developed. The technique addresses two groups of lines in H2O that have a favorable temperature dependence and are easily accessed in a single scan, which makes it sturdy and useful for industrial applications. A technique for detection of NO on its strong electronic transitions by direct absorption spectrometry (DAS) using cw UV diode laser light has been deve­loped. Since the electronic transitions are ca. two or several orders of magnitude stronger than of those at various rotational-vibra­tional bands, the system is capable of detecting NO down to low ppb∙m concentrations solely using DAS. Also the FAMOS technique has been further developed. A new theoretical description expressed in terms of both the integrated line strength of the transition and 1st Fourier coefficients of a magnetic-field-modulated dispersive lineshape functions is presented. The description has been applied to both ro-vib Q-transitions and electronic transitions in NO. Simulations under different pressures and magnetic field conditions have been made that provide the optimum conditions for both cases. A first demonstration and characteri­zation of FAMOS of NO addressing its electronic transitions in the UV-region has been made, resulting in a detection limit of 10 ppb∙m. The characterization indicates that the technique can be significantly improved if optimum conditions can be obtained, which demonstrates the high potential of the UV-FAMOS technique.
9

Tunable diode laser absorption spectroscopy characterization of impulse hypervelocity CO2 flows

Meyers, Jason 11 September 2009 (has links)
Tunable diode laser absorption spectroscopy using an external cavity diode laser operating in the infra-red has been developed to monitor CO2 in the freestream of the Longshot hypervelocity facility at the Von Karman Institute for Fluid Dynamics. The Longshot facility offers a unique European facility for ground testing and numerical validation applications, however, some of the traditional data rebuilding aspects are in question. A non-intrusive absorption<p>sensor could significantly aid in improving the knowledge of freestream static values thereby improving the models used in data rebuilding and numerical simulation. The design of such a sensor also expands the spectroscopic capabilities of the Von Karman Institute.<p><p>The absorption sensor is designed around the single P12 (00001)-(30013) rovibrational transition near 1.6µm (6218.09cm-1 specifically) which yields relatively weak direct absorption levels at about 3.5% per meter for typical Longshot freestream conditions. However, when handled carefully, adequate signal-to-noise can be acquired to exploit significant flow information. By being able to operate in this range, total sensor cost can be easily an a factor of two or more cheaper than sensors designed for the deeper infrared. All sensor elements were mounted to a compact portable optics bench utilizing single-mode optical fibers to allow for quick installation at different facilities by eliminating tedious optical realigning. Scans at 600Hz were performed over 20ms of the 40ms test time to extract core static temperature, pressure and velocity.<p><p>These results are compared with the current state of the Longshot data rebuild method. The non-uniform flow properties of the shear layer and test cabin rested gas accumulation was of an initial concern. The temperature and density gradients along with significant radial velocity components could result in DLAS temperature, pressure and velocity that are significantly different than that of the target freestream inviscid core values. Fortunately, with the proper selection of the P12 rotational number, this effect could be more or less ignored as the higher temperature and lower density gas of this region is relatively transparent.<p><p>Ultimately, acquired temperature and density were moderately accurate when compared to Longshot rebuilt results owing primarily to the baseline extraction which poses issues for such low absorption signals. However, the extracted velocity data are quite accurate. This is a definite puls for the sensor as the freestream enthalpy of cold hypersonic facilities is dictated primarily by the kinetic energy contribution. Being able to compare velocity gives insight to the level of vibration non-equilibrium in the flow. The velocity of the DLAS and the Longshot rebuild are quite close. This adds more weight to the argument that vibrational excitation is very low (if present at all) in the free stream and that the van de derWaals equation of state usage and constant specific heat assumption might be an adequate model for the data rebuild after all. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
10

Ns Pulse / RF Hybrid Plasmas for Plasma Chemistry and Plasma Assisted Catalysis Applications

Gulko, Ilya Dmitrievich January 2020 (has links)
No description available.

Page generated in 0.0866 seconds