• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 100
  • 5
  • 3
  • Tagged with
  • 108
  • 68
  • 54
  • 21
  • 19
  • 14
  • 14
  • 13
  • 12
  • 11
  • 11
  • 10
  • 10
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação da efetividade do laser terapêutico no controle de índice de dor de pacientes em tratamento ortodôntico

Martins, Isabela Parsekian [UNESP] 15 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-15Bitstream added on 2014-06-13T19:15:33Z : No. of bitstreams: 1 martins_ip_me_arafo.pdf: 359151 bytes, checksum: 80f28aedb7d3c2c8701cee1f7592cef1 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a aplicação do laser diodo AsGaAl no controle da sensação dolorosa de paciente em procedimento de separação dental dos 1os molares inferiores. Participaram da pesquisa 62 pacientes com idade média de 19,7 anos que iniciaram o tratamento ortodôntico na Clínica de Pós-Graduação da Disciplina de Ortodontia do Departamento de Clínica Infantil da Faculdade de Odontologia de Araraquara - UNESP. Os pacientes foram divididos em 4 grupos alternando a aplicação do laser com e sem efeito terapêutico e de acordo com rodízio do lado do início de sua aplicação: GrupoI- Início laser lado direito; Grupo II- Início placebo lado direito; Grupo III- Início laser lado esquerdo Grupo IV -Início placebo lado esquerdo. O laser, com ou sem efeito terapêutico, foi aplicado antes da separação, 24 e 48 horas após a separação. A dor foi avaliada por uma escala visual analógica. O índice de dor foi registrado antes e após a aplicação do laser com ou sem efeito terapêutico dependendo do grupo, e imediatamente após a separação. Após 24 e 48 horas, o registro da dor se deu antes e após as aplicações de laser com ou sem efeito terapêutico dependendo do grupo. Antes e após a irradiação, a média dos escores da EVA para o grupo placebo e laser foi de zero. Logo após a separação, a média da EVA para o grupo placebo foi de 1,6, significantemente maior que a média de 1,1 registrada para o grupo laser 17 (p=0,013). Após 24 horas e antes da nova irradiação, os valores de dor registrados entre os grupos não se mostraram diferentes, com valores de 2,6 e 2,2 para os grupos placebo e laser, respectivamente. Após a irradiação, os valores caíram para 1,8 e 1,6 não se mostrando diferentes. Após 48 horas, os valores... / The objective of this research was to compare the effect single low-level laser therapy (LLLT) irradiation on pain perception in patients having fixed appliance treatment in the clinic of postgraduate discipline Orthodontics Department, Araraquara-UNESP. Sixty-two patients with mean age, 19.7 years, were recruited to participate in this randomized, double-blinded, placebo-controlled study. The pacients were assigned to 4 groups: Group I- Laser on the right side; Group II- Placebo on the right side; Group III- Laser on the left side; Group IV- Placebo on the left. The laser or placebo was applied before separation, 24 and 48 hours after separation of their first permanent molars in the lower arch. The pain was recorded by a visual analog scale. The data of the pain’s scale was recorded before and after the laser’s or placebo’s irradiation depending on the group, and immediately after separation and then after 24 and 48 hours. Before and after irradiation, the average of the scores of EVA to the placebo group and laser was zero. Just after the separation, the average of the EVA for the placebo group was 1.6, significantly greater than the average of 1.1 registered for the laser Group (p = 0.013). After 24 hours and before the new irradiation, the values registered among the different groups did not show any diferences, with values from 2.2 to 2.6 and placebo groups and laser, respectively. After irradiation, the values dropped to 1.8 and 1.6 not showing 19 differences. After 48 hours, the values continued dropping without any differences. In relation to the gender, only after the first irradiation in placebo group, the female had a level of pain (0.1) significantly higher (p = 0.04) compared to male, and after 48 hours, the group where the laser was applied had a difference (p = 0.04) among the gender with a value of lower pain... (Complete abstract click electronic access below)
42

Ressonância magnética detectada eletricamente em diodos de Alq3 / Electrically detected magnetic resonance of Alq3 based diodes

George Barbosa da Silva 02 September 2004 (has links)
Ressonância magnética detectada eletricamente (RMDE) de banda-X (9 GHz) e de banda-K (24 GHz) foram usadas para estudar diversos diodos baseados em tris-8(hidroxiquinolinolato) de alumínio III (Alq3). A técnica de RMDE consiste, basicamente, em medir a variação da condutividade quando o sistema entra na condição de ressonância magnética; assim, é possível relacionar propriedades de transporte elétrico com as funções de onda das moléculas envolvidas no processo. Para este estudo foram confeccionados diodos eletroluminescentes e unipolares de multicamadas no Laboratoire d'Optoélectronique des Materiaux Moléculaire (LOMM), da École Polytechnique Fédérale de Lausane (EPFL), Suíça, pelo Dr. Frank Nüesch. Faz parte também deste trabalho a montagem experimental do sistema de RMDE de banda-K, onde a maior parte dos dados foram obtidos. O sinal de RMDE dos diodos unipolares, da ordem de 1E-6, é atribuído ao processo dependente de spin de saltos eletrônicos que ocorre próximo às interfaces. O sinal típico de RMDE dos diodos eletroluminescentes é mais intenso, da ordem de 1E-4, e é atribuído à ressonância de spin-1/2 na formação dos éxcitons. O espectro de RMDE, por meio de ajuste de curvas, pôde ser decomposto em duas gaussianas: uma com largura de linha pico-a-pico DHPP de 1,6 mT, independente do campo elétrico aplicado no dispositivo, e outra variando de 2,0 mT a 3,4 mT. A componente mais estreita se deve à ressonância do radical positivo de Alq3, enquanto que a componente mais larga àquela do negativo. O estudo da forma de linha e de sua dependência com o campo elétrico dos espectros de RMDE de diodos unipolares dão suporte à ambas as atribuições. Neste trabalho, a questão da eficiência quântica e da zona de recombinação também são discutidas. / Electrically Detected Magnetic Resonance (EDMR) at X-band (9GHz) and K-band (24 GHz) were used to investigate Alq3 based diodes. EDMR technique consists basically of measuring conductivity variation at magnetic resonance conditions; thus, it is possible to correlate electrical transport properties with wave functions of the molecules involved in the process. Electroluminescent and unipolar multilayer diodes were prepared in the Laboratoire d'Optoélectronique des Materiaux Moléculaire (LOMM), at on École Polytechnique Fédérale de Lausane EPFL, Switzerland by Dr. Frank Nüesch. The experimental setup of the K-band EDMR system, where most of the data were obtained, was also part of this work. The unipolar diodes EDMR signal is of the order of 1E-6 and is attributed to spin dependent hopping process close to the interfaces. The electroluminescent diodes typical EDMR signal is more intense, of the order of 1E-4 , and is attributed to exciton´s formation spin-1/2 resonance. The EDMR spectrum can be decomposed into two Gaussians: one with peak-to-peak line width (DHPP) of 1.6 mT, independent of the electrical field applied to the devices, and other one whit DHPP of 2.0 mT to 3.4 mT. The narrower component is due to the resonance of positive Alq3 radical, while the larger component is due to the negative. Both attributions are supported by the investigation of line shape and its dependence of electrical field in the unipolar diodes EDMR spectra. In this work, the quantum efficiency and the recombination zone issues are also discussed.
43

Transport through leaked Majorana modes in quantum dots and adatoms / Transporte através de modos de Majorana em pontos quânticos e adátomos

Poliana Heiffig Penteado 05 November 2013 (has links)
We investigate quantum resonant transport in two different systems: (i) a ferromagnetic Scanning Tunneling Microscope (STM) tip coupled to an adatom (interacting) on a host surface (metallic or semiconductor), and (ii) a quantum dot connected to source and drain leads and side-coupled to a superconducting nanowire sustaining Majorana zero modes (Kitaev chain). Both problems are studied within the Green’s functions approach, which allows us to determine the transport properties of the system. In the first setup, due to the ferromagnetic and nonmagnetic ‘natures’ of the tip and host, respectively, it is possible to obtain the spin-diode effect, which occurs only in the singly occupied regime. In addition, because of the presence of the adsorbed atom on the surface, Friedel oscillations are observed in the current. The second system differs from the first mainly because it is spinless and there is no Coloumb interaction. Interestingly, we find that the Majorana mode of the wire leaks into the dot thus giving rise to a Majorana (zero mode) resonance in the dot, pinned to the Fermi level of the leads. Surprisingly, this resonance occurs even when the gate-controlled dot level is far above or far below the Fermi level of the leads. We study three possible experimental scenarios to probe unambigoulsy this Majorana mode in wires via these leaked/pinned modes. / Nesta tese investigamos transporte quântico ressonante em dois sistemas diferentes: (i) uma ponta STM ferromagnética acoplada a um átomo (interagente) adsorvido em uma superfície metálica ou semicondutora, e (ii) um ponto quântico conectado a reservatórios de elétrons e lateralmente acoplado a um nanofio supercondutor que possui modos de Majorana (cadeia Kitaev). Ambos os problemas são estudados no contexto de funções de Green, o que nos permite determinar as propriedades de transporte do sistema. Na primeira configuração, devido à natureza ferromagnética e não magnética da ponta STM e da superfície e, respectivamente, é possível obter o efeito diodo de spin, que ocorre apenas no regime em que o adátomo está ocupado com um único elétron. Além disso, por causa da presença do átomo adsorvido sobre a superfície, oscilções de Friedel são observadas na corrente. O segundo sistema é diferente do primeiro, principalmente pela ausência da interação de Coloumb e pelo fato de não ter spin. Curiosamente, vemos que o modo de Majorana do fio vai para o ponto quântico dando origem assim a um modo com energia zero no ponto quântico localizado sempre no nível de Fermi dos contatos. Surpreendentemente, essa ressonância ocorre mesmo quando o nível do ponto quântico, controlado por uma tensão externa, está muito acima ou muito abaixo do nível de Fermi dos contatos. Propomos três possíveis cenários experimentais para identificar de maneira conclusiva este modo de Majorana em fios através do modo que aparece no ponto quântico.
44

\"Avaliação da desinfecção da dentina radicular em profundidade provocada pela irradiação do laser de diodo de alta potência\" / Evaluation of root canal dentin desinfection in depth caused by high power diode laser irradiation.

Eliana Barbosa de Souza 07 February 2007 (has links)
A presença de microrganismos no interior do sistema de canais radiculares é a principal causa do fracasso na terapia endodôntica. A importância da sanificação durante o preparo do canal fica clara, portanto. Dentre os microrganismos isolados nos casos de insucesso o Enterococcus faecalis é comumente encontrado. O E. faecalis é um microrganismo resistente à terapia endodôntica, à medicação intracanal de hidróxido de cálcio e sua presença contribui para o insucesso em Endodontia. A radiação laser apresenta características antimicrobianas que podem auxiliar no tratamento endodôntico. Esse estudo tem por objetivo avaliar o grau de descontaminação provocado pelo uso do laser de diodo de alta potência na dentina radicular em profundidade, após preparo químico-cirúrgico in vitro. Foram utilizadas 30 raízes de dentes unirradiculares ? esterilizadas em autoclave - que depois de inoculadas por E. faecalis cepa ATCC 29212 durante 4 semanas, foram divididas em 3 grupos: grupo 1 instrumentação rotatória - K3 (Sybron Endo, Orange, CA, EUA) com hipoclorito de sódio 0,5 % e creme Endo PTC, irrigação final com EDTA-T 17 % e posterior irradiação com laser de diodo de alta potência com comprimento de onda 830 nm na potência de 3 W por 5 s com 4 repetições segundo Gutknecht; grupo 2 instrumentação, como grupo 1, sem irradiação e grupo 3 apenas irrigação com 20 mL de solução fisiológica estéril. Os espécimes foram divididos em três terços (cervical, médio e apical), tiveram suas paredes dentinárias desgastadas por brocas Batt e as raspas, bem como o cilindro externo restante de dentina foram imersos em 1 mL de água peptonada. Assim alíquotas foram semeadas em meio seletivo mEnterococcus, em triplicata para contagem de unidades formadoras de colônias. Os resultados foram tratados estatisticamente pelo teste Kruskal-Wallis com método de comparação Dunn e apresentaram as seguintes médias: Grupo 1 ? 0, Grupo 2 ? 2,77 X 102, Grupo 3 ? 171 X 102 u.f.c./mL; com diferenças estatísticas significantes entre os 3 grupos (p<0,05). Em porcentagens, a redução da microbiota provocada pelo Grupo 1 foi de 100% e do Grupo 2 de 98,39% ambas em relação ao Grupo 3 (controle). A irradiação do laser de diodo nos parâmetros e amostras testadas foi eficaz na redução da contaminação em profundidade da dentina radicular frente ao Enterococcus faecalis. / The main cause for failure in Endodontics is the presence of microorganisms in root canal system. Enterococcus faecalis is a resistant microorganism presents in failure endodontic treatment. Therefore the disinfection plays fundamental rule in endodontic therapy. The laser irradiation presents properties that may improve the treatment success rates, reducing the microbial contamination. The aim of this study is evaluate the disinfection degree in depth caused by diode laser irradiation after chemomechanical procedures in vitro. Thirty extracted dental roots were sterilized by autoclave, inoculated by strain of Enterococcus faecalis ATCC 29212 during 4 weeks, and then randomly divided in 3 groups. Group 1: 10 specimens were instrumented by rotary files K3 (Sybron Endo, Orange, CA, USA) with 0.5 % sodium hypochlorite and urea peroxide (Endo PTC cream, Oficinalis Farmácia de Manipulação, São Paulo, SP, Brazil). At the end irrigation by 17 % EDTA-T was performed. The specimens were irradiated intracanal by diode laser 830 nm wavelength 3 W during 5 seconds, four times. Group 2: same procedures of group 1 without laser irradiation. Group 3: irrigation by saline solution. The specimens were divided in three thirds (apical, middle and cervical). Samples of dentin were obtained with carbide burs from inner canal walls of each third. The samples were immersed in 1 mL of peptonic water, and then aliquots were sowed to count viable cells in mEnterococcus agar (Difco?, Becton Drive, NJ, USA). The groups showed the following means: Group 1 ? 0, Group 2 ? 2,77 X 102 and Group 3 ? 171 X 102 CFU/mL. The disinfection degree achieved was 100 % in group 1, 98,39 % in group 2 both compared with group 3. The Kruskal-Wallis statistical analysis with Dunn method of comparison shows better results in group with diode laser irradiation (p<0.05), followed by group 2 and 3. Irradiation by diode laser in that samples and parameters achieved disinfection improvement in root dentin depth.
45

Desenvolvimento de sistema LIBS-LIF / Development of a LIBS-LIF system

André Fragalli 07 November 2017 (has links)
A espectroscopia de emissão atômica de plasma induzido por laser (LIBS, do inglês Laser Induced Breakdown Spectroscopy) é uma técnica multi-elementar que tem ganhado destaque recentemente devido à sua facilidade de uso em diversas aplicações. Entretanto, o limite de detecção da técnica é alto para alguns elementos se comparada com outras técnicas (e.g. ICP). Assim, o objetivo deste trabalho é aperfeiçoar a sensibilidade de um sistema LIBS na configuração de pulso único, através da integração com a técnica de fluorescência induzida por laser (LIF). Isso é feito por meio da inserção de um laser com um comprimento de onda em uma transição ressonante do elemento cuja intensidade de emissão deseja-se ter elevada, visando a redução dos efeitos de matriz das amostras. Para este fim, foram desenvolvidos um laser de diodo contínuo de cavidade estendida e sua eletrônica de controle, almejando um sistema robusto, estável em frequência, com baixo ruído espectral e resistente a estresses mecânicos, elétricos e térmicos. Os mesmos foram integrados a um sistema LIBS para ser feita a comprovação da eficiência da técnica LIBS-LIF. / The laser-induced breakdown plasma spectroscopy (LIBS) is a multi-elemental technique that has been gainning prominence recently due to its easy usability in various applications. However, the limit of detection of this technique is high for some elements compared to other techniques (e.g. ICP). Thus, the objective of this work is to improve the sensitivity of LIBS on the single pulse configuration, through integration with the laser-induced fluorescence (LIF) technique. This is done adding a laser with a wavelength in a resonant transition of the element whose emission intensity needs to be improved, focusing on reducing the matrix effects of samples. To achieve this purpose, a continuous external cavity diode laser was developed and its control driver, aiming to create a robust system, stable in frequency, with low spectral noise and resistant to adverse mechanical, electrical and thermal stresses. Both were integrated with a LIBS system for the evaluation of the LIBS-LIF technique efficiency.
46

Excitação coerente de um vapor atômico por trens de pulsos ultracurtos e lasers contínuos

Souza, Marco Polo Moreno de 31 January 2012 (has links)
Submitted by Danielle Karla Martins Silva (danielle.martins@ufpe.br) on 2015-03-06T15:13:28Z No. of bitstreams: 2 tese_MarcoPoloMoreno.pdf: 5025898 bytes, checksum: ac91337962a78e4573af92599eea0dec (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-06T15:13:28Z (GMT). No. of bitstreams: 2 tese_MarcoPoloMoreno.pdf: 5025898 bytes, checksum: ac91337962a78e4573af92599eea0dec (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012 / CNPq ; CAPES; FACEPE, / Apresentamos uma abordagem, com ênfase no domínio das frequências, para o problema da excitação de átomos por um trem de pulsos ultracurtos. Trabalhamos no regime de acumulação coerente, no qual o intervalo de tempo entre os pulsos é menor do que os tempos de relaxação do meio. Primeiramente, revisamos os fundamentos da interação coerente entre lasers, contínuos e pulsados, e sistemas atômicos, onde introduzimos o formalismo da matriz densidade para um sistema de dois níveis. Este formalismo é depois estendido para sistemas de três níveis na configuração tipo lambda e em cascata. Utilizamos a solução numérica das equações de Bloch integradas no tempo para modelar a impressão do pente de frequências no perfil Doppler de um vapor de átomos de rubídio na presença de um feixe de prova contínuo. No regime de campo fraco, apresentamos um tratamento teórico para a coerência atômica induzida por um trem de pulsos em átomos de dois níveis, que nos permitiu chegar a uma solução fechada para a coerência em termos dos modos do pente de frequências. Essa abordagem, no domínio da frequência, é usada para analisar o armazenamento coerente de população em um sistema de três níveis do tipo lambda, nas proximidades das ressonâncias de um e de dois fótons. A partir de resultados numéricos e analíticos, obtemos um pente de linhas de transparência eletromagneticamente induzida (EIT). Propomos a observação experimental desse pente de EIT no perfil Doppler através de um feixe de prova contínuo. Por fim, empregamos a abordagem no domínio das frequências para modelar resultados de dois experimentos. No primeiro, usamos um laser de diodo contínuo para sondar o bombeio óptico induzido por um laser de Ti:safira com 1 GHz de taxa de repetição em vapor de átomos de rubídio. A alta taxa de repetição permitiu resolver as transições hiperfinas para os estados 5P1/2 e 5P3/2. Discutimos os resultados obtidos a partir das técnicas de espectroscopia seletiva em velocidade e da espectroscopia com taxa de repetição. No segundo experimento, usamos a ação combinada do laser de diodo e do trem de pulsos ultracurtos na transição ressonante por dois fótons 5S−5P−5D para fazer espectroscopia dos níveis hiperfinos 5D3/2 e 5D5/2. O experimento é realizado sem travar a frequência de off-set do laser de Ti:safira, a qual estimamos a partir dos resultados experimentais.
47

Desenvolvimento de um sistema simplificado de laser e célula de vapor para espectroscopia em átomos de cálcio / Simplified laser system and vapor cell for spectroscopy of calcium atoms

Fernandez Apolinario, Ulices, 1988- 12 October 2010 (has links)
Orientador: Luis Eduardo Evangelista de Araujo / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-17T12:16:24Z (GMT). No. of bitstreams: 1 FernandezApolinario_Ulices_M.pdf: 3294486 bytes, checksum: d7134abb4e7c7345ce3358e57af0e8db (MD5) Previous issue date: 2010 / Resumo: Nesta tese, descrevemos o desenvolvimento de um sistema laser simplificado que opera em 423 nm (baseado em um laser de diodo) e a construção de uma célula de vapor de cálcio com potencial uso em espectroscopia de alta resolução. Nosso trabalho começou com a construção de um laser de diodo em cavidade estendida operando em 846 nm e com uma potência útil de 158 mW que foi montado em configuração Littrow. Em seguida, foi duplicada a freqüência deste laser para 423 nm através de um cristal BIBO (BiB3O6), utilizado dentro de uma cavidade óptica de amplificação. A estabilização da cavidade óptica duplicadora de freqüência foi feita pela técnica de Hänsch-Couillaud para travar uma ressonância da cavidade ao laser infravermelho de entrada. Um máximo de potência de 20 mW no azul foi obtido, mas problemas relacionados ao travamento da cavidade duplicadora dificultam seu uso. Por isto, um segundo laser de diodo em cavidade estendia, similar ao anterior, mas com uma potência útil de 75 mW, foi usado com uma potência máxima de 4 mW no azul e apresentado similares dificuldades ao sistema desenvolvido anteriormente. Uma célula de vapor de cálcio foi construída tendo como fonte de átomos de cálcio um dispensador ¿Alvasource¿ da empresa ¿Alvatec¿. Uma primeira caracterização da célula através de espectroscopia de absorção foi realizada demonstrando seu potencial uso para experimentos em Física Atômica / Abstract: In this thesis, we describe the development of a simplified laser system that operates at 423 nm (based on a diode laser) and the construction of calcium vapor cell with potential use in high resolution spectroscopy. Our work began with the construction of a extended-cavity diode laser operating at 846 nm with an output of 158 mW that was mounted in Littrow configuration. Then, the laser¿s frequency was doubled to 423 nm through a BIBO (BiB3O6) crystal used within a power enhancement cavity. The stabilization of the frequency doubling cavity was made by Hänsch-Couillaud technique to lock a cavity resonance to the input infrared laser. A maximum power of 20 mW was obtained in the blue, but problems related to locking the doubling cavity hamper its use. Therefore, a second extended-cavity diode laser, similar to the above but with an output of 75 mW was tried, reaching a maximum power of 4 mW in the blue. However, it presented similar difficulties to the system developed earlier. A calcium vapor cell was constructed based on Ca ¿Alvasource¿ dispenser by ¿Alvatec¿. A first characterization of the cell by absorption spectroscopy was performed demonstrating its potential use for experiments in atomic physics / Mestrado / Ótica / Mestre em Física
48

Endodontic treatment of teeth with periapical lesion in one session with photodynamic therapy as an adjuvant: study "in vivo" / Tratamento endodôntico de dentes portadores de lesão periapical em sessão única tendo como coadjuvante a terapia fotodinâmica: estudo in vivo

Supercilio Barros Filho 23 March 2012 (has links)
Hypothesis of the study: It is assumed that the use of photodynamic therapy (PDT) as an adjuvant in root canal therapy can promote the repair of teeth with periapical lesions treated in one session. Objectives: This in vivo study was to evaluate the effects of photodynamic therapy as an adjuvant in root canal therapy in one session for the repair of periapical lesions. Method: Fourteen human teeth with mortification pulp and periapical lesions were randomly divided into two groups (n=7): G1- endodontic treatment was performed in one session and G2 underwent endodontic therapy in one session associated with photodynamic therapy. The photodynamic therapy used methylene blue dye (100&#956;/mL) for five minutes and diode laser low power (685nm, 100mW) for three minutes. The follow-ups were performed by periapical radiographs. The images were evaluated by the computer program Adobe Photoshop CS 5.1, using the system K values. By which we assessed the area of periapical bone healing. Radiographs were taken prior to execution, immediately after treatment, and six months following the treatment. Results: There were statistically significant differences between the G2- endodontic therapy in one session associated with photodynamic therapy and G1- endodontic therapy in one session (p<0.05) without PDT. Conclusion: The endodontic treatment in one session associated with photodynamic therapy was more effective in repair of the periapical lesion. / Hipótese do estudo: O emprego da terapia fotodinâmica (PDT) como coadjuvante do tratamento endodôntico possa favorecer a reparação de dentes portadores de lesão periapical, tratados em sessão única. Objetivos: Este estudo in vivo, teve por objetivo avaliar, os efeitos da terapia fotodinâmica como coadjuvante do tratamento endodôntico em sessão única, na reparação de lesões periapicais. Método: Quatorze dentes humanos portadores de mortificação pulpar e lesão periapical, foram aleatoriamente divididos em dois grupos (n=7): G1- foi realizado tratamento endodôntico em sessão única, G2- foi submetido à terapia endodôntica em sessão única, associado à terapia fotodinâmica. Para a terapia fotodinâmica utilizou-se como corante o azul de metileno (100&#956;/mL) por cinco minutos e o laser de diodo de baixa potência (685nm, 100mW) por três minutos. A proservação foi realizada por meio de radiografias periapicais. As imagens foram avaliadas por um programa de computador Adobe Photoshop CS 5.1, valendo-se dos valores médios de K. Pelo qual foi avaliado a área de cicatrização óssea periapical. As radiografias foram tomadas antes da execução do tratamento endodôntico, imediatamente após e proservado com cento e oitenta dias após o tratamento. Resultados: Houve diferença estatísticamente significante entre o grupo G2- terapia endodôntica em sessão única associado à terapia fotodinâmica e G1- terapia endodôntica em sessão única (p< 0,05). Conclusão: O tratamento endodôntico em sessão única associado à terapia fotodinâmica mostrou-se mais eficaz na reparação da lesão periapical.
49

"Interação do laser de diodo de alta potência com a superfície radicular. Efeito na morfologia, na variação de temperatura e na adesão e proliferação de fibroblastos em cultura" / Interaction between high power diode laser and dental root surface. Thermal, morphological and biocompatibility analysis

Patrícia Haypek 23 February 2006 (has links)
O objetivo do estudo foi analisar a interação entre o laser de diodo de alta potência e a superfície radicular através da análise de: variação de temperatura (Fase A), morfologia superficial das raízes dentárias (Fase B), adesão e a proliferação de fibroblastos cultivados sobre estas superfícies (Fase C). Vinte e um dentes unirradiculares foram utilizados nas 3 fases dos experimentos. Os grupos experimentais foram: Grupo controle - só recebeu o tratamento inicial de raspagem e alisamento radicular; Grupo INT - recebeu o mesmo tratamento do controle seguido de irradiação com o laser de diodo de alta potência, com comprimento de onda de 808 nm e fibra óptica de 400 µm de diâmetro, posicionada paralela à superfície radicular no parâmetro de 1,5 W (597,1 W/cm 2 na ponta da fibra) durante 30 s no modo interrompido; e Grupo CW - onde foi usado o mesmo tratamento do grupo INT, porém com o laser no modo contínuo. Na fase A utilizaram-se termopares para monitorar a temperatura intrapulpar; na Fase B, microscopia eletrônica de varredura (MEV) das superfícies tratadas dos 3 grupos experimentais, e na Fase C, fibroblastos foram plaqueados sobre as superfícies tratadas e em eletromicrografias de varredura as células foram contadas em 24 (adesão), 48 e 72 h (proliferação) após o plaqueamento. A monitoração de temperatura demonstrou que, com os parâmetros utilizados, houve aumento de temperatura dentro dos limites biocompatíveis e que esse aumento foi significantemente maior no grupo CW do que no grupo INT. Nos grupos irradiados observou-se presença de smear-layer modificada, exibindo uma superfície com áreas de aspecto mais liso correspondendo às áreas de fusão e ressolidificação, entremeadas por zonas de aspecto mais corrugado. Túbulos dentinários abertos não foram observados. Os fibroblastos plaqueados sobre as superfícies irradiadas aderiram e aumentaram em número no decorrer do tempo experimental. As curvas de crescimento celular sobre as superfícies irradiadas com os dois modos do laser apresentaram comportamento biológico similar entre si e com o controle. Pode-se concluir, nas condições deste estudo, que o uso do laser de diodo de alta potência é seguro do ponto de vista térmico, e causa alterações morfológicas superficiais similares, independentemente dos modos de irradiação. Adicionalmente, essas superfícies radiculares irradiadas são biocompatíveis, possibilitando a adesão e a proliferação celular / The aim of this study was to analyze the interaction between the high power diode laser and the dental root surface through the temperature variation analysis (Step A), root surface morphological observation (Step B), adhesion and proliferation of fibroblasts cultured on the top of the root surfaces (Step C). Twenty-one uniradicular teeth were used in the 3 steps of the experiments. The experimental groups were, as follows: Control group - root planning and scaling using Gracey curets; INT group - the root surfaces received the same treatment as control group followed by laser irradiation (high power diode laser, wavelength 808 nm, 400 µm optical fiber used parallel to the root surface, 1,5 W for 30 s, 597,1 W/cm 2 ), and CW - treated as the INT group however in a continuous wave. For the step A thermocouples were used; for step B, scanning electron microscopy (SEM) of the treated root surfaces of the 3 experimental groups, and at the Step C, fibroblasts were plated on the top of the root surfaces, and in scanning electronmicrographs the attached cells were counted 24 (adhesion), 48 e 72 h (proliferation) after plating. The temperature monitorization showed that, with the parameters used, there was an increase in temperature within the biological safety limits and, this increase was significantly higher for the CW group. At the root surfaces of irradiated groups a modified smear-layer was observed exhibiting rough areas intermingled to smooth areas corresponding to areas of fusion and resolidification of dental hard tissues. Open dentinal tubules were not observed. The fibroblasts plated on the top of the irradiated surfaces adhered and proliferated throughout the experimental time (0 to 3 days). The growth curves of the irradiated groups, independently of the irradiation mode, showed biological behavior similar between them and with the control group. At the conditions of this study, we concluded that the use of high power diode laser for root surface conditioning is thermically safe and causes similar superficial morphological changes independently of the irradiation mode used. Additionally, these root surfaces are biocompatible because did not impair the cell adhesion and growth
50

Sistema de laser de diodo de cavidade estendida para padrões de frequência / Extended cavity diode laser system for primary frequency standards

Jair De Martin Junior 10 May 2013 (has links)
Este trabalho tem como objetivo principal desenvolver uma nova fonte de laser de diodo compacta e robusta, além de um novo drive de controle para serem utilizados em padrões primário de tempo e frequência tipo chafariz de átomo de Césio e padrões compacto baseados em átomos frios. Um dos requisitos para utilização de laser de diodo em padrões primários de tempo e frequência é sua estabilidade em frequência e baixíssimo ruído espectral. Além disto, dada à aplicação embarcada, o laser deve ser extremamente robusto com relação às condições adversas: mecânicas, térmicas e elétricas. Tanto a parte optomecânica, quanto os controles eletrônicos do novo laser foram desenvolvidos neste trabalho. Vale salientar que tal sistema, em sua concepção, é de grande interesse para diversos outros tipos de aplicação, como espectroscopia de gases (LIDAR), referências em outras frequências e experimentos de física atômica e molecular, que possuem elevados níveis de exigência com relação a ruídos espectrais. / This work has as main objective to develop a new source of diode laser compact and robust, beyond a new drive control for use in primary of time and frequency standards type cesium atom fountain and compact standards-based cold atoms. One of the requirements for the use of diode laser in primary of time and frequency standards are their stability in frequency and are very low spectral noise. Furthermore, given the embedded application, the laser must be extremely robust with respect to adverse conditions: mechanical, thermal and electrical. Both opto-mechanical part, as the electronic controls of the new laser were developed in this work. It is noteworthy that such a system, in its conception, is of great interest to many other types of applications such as spectroscopy of gases (LIDAR), references in other frequencies and experiments of atomic and molecular physics, which have high levels of demand with respect to spectral noise.

Page generated in 0.0422 seconds