• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterización de una Aleación Superelástica CuZnAl Extruida, Considerada para Disipadores de Energía Sísmica

Vera Stuardo, Armando Darío January 2007 (has links)
Los disipadores de energía sísmica permiten evitar daños en estructuras civiles. Para dichas aplicaciones es posible considerar a las aleaciones con memoria de forma (SMA), bajo condiciones de comportamiento superelástico, en relación con la transformación martensítica inducida por esfuerzo. En este contexto, el objetivo de la presente memoria es caracterizar la microestructura y las propiedades mecánicas (tradicionales y superelásticas) de una aleación Cu-17,0 %p.Zn7.2 %p.Al policristalina, preparada por fusión en un laboratorio nacional. Luego de forja y extrusión en caliente, se fabricaron probetas de 7 mm de diámetro, para ensayos de tracción estática y dinámica a distintas temperaturas (13-16, 25 y 50oC) y frecuencias ((0,1 a 2 Hz, precisando que la mayoría de los ensayos se realizó a 1Hz). La microestructura de las probetas era austenítica, con coexistencia de granos equiaxiales (recristalizados) y alargados (no recristalizados); el tama˜no de grano medio era superior a 0,1 mm. Los ensayos de tracción se realizaron con control de avance del cabezal; se utilizó un extensómetro de 25 mm. Por calorimetría diferencial de barrido, se estableció un valor de temperatura de fin de transformación austenítica, Af, de 22oC. Los ensayos de tracción estática mostraron una tendencia del esfuerzo de transformación martensítica a crecer con la temperatura, según lo esperado teóricamente. El análisis fractográfico, por microscopia electrónica de barrido, mostró fractura transgranular, con zonas de clivaje y otras con hoyuelos. Las deformaciones máximas a la fractura (con carga) estuvieron entre 4,4 % y 6,3 %. De los ensayos de tracción dinámica, realizados a 1Hz, con series de 10 ciclos, e incrementando la deformación serie a serie, se concluye: -Existe una razonable similitud entre la envolvente de los ensayos cíclicos y la respectiva curva de tracción. -El valor de deformación correspondiente a la cota superior del rango superelástico está entre 1 y 2,1. -El coeficiente de amortiguamiento presenta una tendencia predominantemente creciente al aumentar la deformación impuesta. -Los mayores valores amortiguamiento corresponden al rango de deformaciones postsuperelásticas, donde hay deformaciones permanentes (en el primer ciclo de una serie), y luego ciclos de histéresis. -El calentamiento adiabático observado en el rango superelástico es de hasta 4oC -Existe una relación lineal entre la temperatura alcanzada en la probeta, en cada serie, y el área de los ciclos superlásticos correspondientes. En ensayos realizados a distintas frecuencias (0,1, 0,5, 1, 1,5 y 2 Hz), se encontró que, al crecer la frecuencia, tanto el esfuerzo de transformación como el módulo secante decrecen. La frecuencia no parece afectar significativamente el calentamiento adiabático, en el rango de condiciones experimentales de este estudio.
2

Comportamiento Superelástico de una Aleación Cu-11,8% pA1-0,5%pBe en Ensayos de Tracción Cíclicos bajo Condiciones tipo Sísmicas

González Banda, Giovanni Francisco January 2007 (has links)
En el presente tema de Memoria se estudió el comportamiento mecánico de una aleación superelástica Cu-11,8%p.Al-0,5%p.Be, dentro del rango de temperatura y frecuencia propias de un fenómeno sísmico (0,1 a 5 [Hz]; -20 a + 50 [ºC]). Para esto, se realizaron ensayos de tracción de tipo tradicional (monotónicos) y cíclico. Este trabajo es parte de una línea de investigación relacionada con la caracterización de materiales, particularmente de materiales Superelásticos, pertenecientes a las aleaciones con Memoria de Forma, que puedan servir para la fabricación de dispositivos de disipación de energía sísmica en estructuras civiles. Las características relevantes de los materiales superelásticos, es que ellos presentan, en ciclos de carga-descarga, valores relativamente importantes de deformaciones recuperables y de energía disipada por ciclo. Este comportamiento se relaciona con la transformación de fase Austenita-Martensita. Para esta memoria se contó con una aleación CuAlBe, fabricada por Trefimétaux, bajo la forma de barras de 3 [mm] de diámetro; ensayos preliminares a temperatura ambiente indican que este material es superelástico. Los parámetros considerados en los ensayos son los siguientes: Tamaño de Grano Austenítico (64, 95 y 250 [ µm]); Frecuencia (0.1 y 1 [Hz]); Amplitud de Deformación de los ensayos cíclicos (hasta 4% aprox.); y Temperatura del ensayo (20 y 50 [ºC]). El comportamiento del material se caracterizó bajo los términos siguientes: • En ensayos de tracción uniaxial se caracterizaron algunas propiedades mecánicas del material (Módulo Elástico, Esfuerzos de Fluencia, Esfuerzo Máximo y de Rotura, Deformación Máxima, Ductilidad). • En ensayos de tracción cíclicos, se determinó: el esfuerzo y la deformación asociados a la máxima deformación superelástica alcanzable; los esfuerzos asociados al inicio de las transformaciones martensíticas directa e inversa; módulo elástico de la austenita; módulo secante; y coeficiente de amortiguamiento. Finalmente, los resultados se discutieron en la perspectiva de las relaciones microestructura-propiedades pertinentes y de la aplicación considerada.
3

Modelización numérica del comportamiento estructural de barras de pandeo restringido

Castro Medina, Juan Carlos 27 June 2011 (has links)
The energy dissipators are passive components that are incorporated into buildings and other structures undergoing dynamic excitations, especially earthquakes. Its purpose is to absorb the greatest part of the input energy, thus protecting the main structure. These devices are not a part of the main load-carrying system and therefore can be easily replaced after suffering serious damage. These devices are connected to the structure to be protected in such a way that they experience large strains under the action of the earthquakes; such strains produce the energy absorption. In building structures, the dissipators are installed in frames, usually in concentric bracing bars (either diagonal or chevron braces) since the interstory drifts generate significant distortions in these elements. Various types of dissipators have been proposed for building structures. Those based on yielding of metals, commonly known as hysteretic, are distinguished by their simplicity, economy and robustness; among them, the so-called buckling restrained braces have experienced a remarkable development because of their important advantages. The buckling restrained braces consist of concentric bracing bars composed by a slender steel core surrounded by a stockier casing, usually made of mortar and / or steel. It is crucial that there is a sliding interface between the core and the cover, to prevent relevant shear stress transfer. When the core is pulled or pushed it yields; the casing prevents the buckling of the core. These cycles of tensile and compressive yielding constitute the hysteresis loops through which the energy is dissipated. Despite relevant experience exists on buckling restrained braces (both on research and practical applications) many questions still remain unanswered. In particular, no reliable and accurate model of the structural behavior has been proposed. This lack prevents a deep understanding of the complex phenomena that occur during the operation of these elements, and hinders the development of innovative solutions. This work aims to improve the knowledge about the behavior of these devices, developing a comprehensive numerical model that opens the door for future developments. The results obtained with the proposed numerical model are compared with experimental results obtained at the University of Girona and the University of California.
4

Análisis sísmico comparativo entre un edificio de gran altura con sistema convencional y disipadores de energía

Oblitas Gonzales, Mario January 2024 (has links)
El Perú está ubicado en la franja del cinturón de fuego donde han sucedido más del 80% de sismos de gran magnitud. Entre los sismos más relevantes se tuvo en abril del 2016 en Manta Ecuador y el de Concepción Chile en febrero del 2010 donde colapsaron edificaciones de varios niveles ocasionando 602 y 525 muertes respectivamente. Por lo tanto, es de mucha importancia implementar sistemas de protección sísmica a las edificaciones para disipar la energía ante un evento sísmico moderado a severo y salvaguardar la vida de sus ocupantes. Teniendo en cuenta ello en la presente investigación se hace una comparación entre un sistema convencional y otro implementado con disipadores de fluido viscoso Chevron (DFVC) en un edificio de gran altura en la ciudad de Chiclayo. Como primer paso de la metodología se hizo la caracterización del sitio a través del ensayo de penetración estándar (SPT), estudios geofísicos de refracción sísmica (RS) y análisis multicanal de ondas superficiales (MASW). Posteriormente se realizó el modelado y análisis dinámico modal espectral (ADME) según la norma E.030 para la estructura convencional y el análisis tiempo historia no lineal (ATHNL) para la estructura implementada con DFVC con la Norma ASCE7-16. Como resultados se determinó un suelo S₂, los desplazamientos de la estructura con DFVC se redujeron en 66.66 % y 56.46 % estos disipadores absorben un 60.38 % y 61.26 % de la energía del sismo en dirección X-X e Y-Y respectivamente. / Peru is located in the belt of fire where more than 80% of large earthquakes have occurred. Among the most relevant earthquakes were in April 2016 in Manta Ecuador and Concepción Chile in February 2010 where multi-level buildings collapsed, causing 602 and 525 deaths respectively. Therefore, it is very important to implement seismic protection systems in buildings to dissipate energy in the event of a moderate to severe seismic event and save the lives of its occupants. Taking this into account, in the present investigation, a comparison is made between a conventional system and another implementation with Chevron viscous fluid dissipators (DFVC) in a high-rise building in the city of Chiclayo. As the first step of the methodology, the characterization of the site was carried out through the standard (SPT) penetration test, geophysical studies of seismic refraction (RS) and multichannel analysis of surface waves (MASW). Subsequently, spectral modal dynamic modeling and analysis (ADME) was carried out according to the E.030 standard for the conventional structure and the nonlinear time history analysis (ATHNL) for the structure implemented with DFVC with the ASCE7-16 Standard. As a result, a floor S₂ is calculated, the displacements of the structure with DFVC were reduced by 66.66% and 56.46% these dissipators absorbed 60.38% and 61.26% of the earthquake energy in the X-X and Y-Y direction respectively.es el resumen traducido al idioma inglés.

Page generated in 0.0541 seconds