Spelling suggestions: "subject:"codistribution atemsystem model"" "subject:"codistribution atemsystem godel""
1 |
Development of a Chlorine Decay and Trihalomethane Formation Modeling Protocol Using Initial Distribution System Evaluation DataCooper, James P. 23 December 2009 (has links)
No description available.
|
2 |
Untersuchung und Modellierung der Bildung partikulärer Ablagerungen in TrinkwasserverteilungsnetzenRipl, Klaus 09 September 2016 (has links)
Das Auftreten von Braunwasser in Trinkwasserverteilungsnetzen ist eine Beeinträchtigung der Trinkwasserqualität, die durch mobilisierte partikuläre Ablagerungen verursacht wird. Die Partikel gelangen durch verschiedene Prozesse, wie z. B. der Korrosion metallischer Leitungen und den Eintrag am Wasserwerk, kontinuierlich in sehr geringen Massenströmen in das Rohrnetz. Durch die Akkumulation der Partikel an Rohroberflächen können sich Ablagerungsmengen bilden, die bei ansteigenden Strömungsgeschwindigkeiten resuspendiert werden und zu unerwünschten Braunwassererscheinungen führen.
Die vorliegende Arbeit behandelt die experimentelle Untersuchung des Transportes von Partikeln, die für Trinkwassernetze typisch sind, in Rohrströmungen. Es werden Einflussfaktoren identifiziert, die für den Partikeltransport von Bedeutung sind. Ein neu entwickeltes dynamisches Modell beschreibt den Transport von Partikeln und die Ablagerungsbildung in Rohrströmungen und vermaschten Rohrnetzen. Das Modell wurde in einer Anwendersoftware implementiert und an einem Trinkwasserverteilungsnetz für das Nachvollziehen der beobachteten Ablagerungsbildung eingesetzt.
Im Vergleich zu bestehenden dynamischen Modellen werden partikelbezogene Prozesse unter Berücksichtigung der für trinkwasserbürtige Partikel und Ablagerungen typischen Eigenschaften mathematisch genauer beschrieben. Stationäre und dynamische Ereignisse bezüglich Wasserqualität und Ablagerungsbildung können jetzt durch die Berücksichtung zahlreicher zeitabhängiger Einflussfaktoren nachvollzogen werden. / The occurrence of discoloured water in drinking water distribution systems is a disturbance of the water quality, which is induced by mobilised particulate deposits. Different processes result in the continuous entry of small mass flow rates of particles into the piping, for instance the corrosion of metallic pipes as well as the entry at the water works outlet. By the accumulation of these particles, significant amounts of deposits can be formed and at higher flow rates be resuspended, which leads to unwanted events with discoloured water.
This study examines the experimental investigation of the transport of particles, which are typical for drinking water distribution systems, in pipe flow. Influencing factors are identified, which are of importance for the particle transport. With a newly developed model, the transport of particles and the deposit formation in pipe flow and in piping is described. The model is implemented into a software application and deployed at a drinking water distribution system to understand the observed deposit formation.
In comparison with existent dynamic water quality models, particle-related processes are described mathematically in more details, under consideration of characteristics typical for particles and deposits in drinking water distribution systems. Hence, observed steady-state and dynamic events can be followed using several influencing time-dependent factors.
|
3 |
Vliv disperzních zdrojů na DS 22 kV při vřazení transformovny TR 110/22 KV / Effect of distributed generation on medium voltage 22 kV distribution system operation with a new 110/22 kV feederKonopová, Tamara January 2018 (has links)
This thesis deals with the issue of power flow analysis in a medium voltage (22kV) distribution network with a focus on the influence of distributed energy generation recources. At first the issue of operation of distributed energy resources and their reverse effects on the distribution system is presented in the thesis. Furtherly there are described their operational conditions from the legislation point of view. The part dealing with calculation compares two network configurations in terms of power quality and how the power quality is impacted by distributed energy resources. The attention is given to voltage conditions, short-circuit power, power conditions, losses and flicker. The first configuration corresponds to the real situation in the network, the other one is describing the changes after the new 110/22 kV substation implementation to the power supply area and the overal change of network configuration. The network model and run simulation is done using the E-Vlivy program.
|
Page generated in 0.088 seconds