• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análises e ajustes adaptativos da proteção aplicada a um sistema de distribuição na presença de geração distribuída / Analysis and adaptive adjustments of the protection applied to a distribution system in the presence of distributed generation

Furlan, Renan Hermogenes 24 May 2019 (has links)
A proteção de Sistemas de Distribuição (SDs) é de fundamental importância considerando as condições adversas de operação e faltas elétricas a que os mesmos podem estar submetidos. A crescente utilização de Geradores Distribuídos (GDs) conectados aos SDs e as possíveis operações em ilhamento promovem interferências consideráveis aos dispositivos de proteção. Dessa forma, evidencia-se a importância de estudos para esses novos cenários. Neste contexto, esta pesquisa tem como proposta analisar o desempenho do sistema de proteção, quando na presença de uma elevada contribuição de geração distribuída, e aprimorar a proteção tradicional, quando tem-se a mudança do cenário de operação para o modo ilhado. Sendo assim, evidencia-se através de simulações no Real-Time Digital Simulator (RTDS) os efeitos da perturbação nos Relés de Sobrecorrente (RSC). Na metodologia desenvolvida implementa-se um sistema de proteção adaptativo, cujos parâmetros são definidos por um algoritmo de otimização. Também são adicionadas as proteções associadas aos GDs, recomendadas por norma. Tal prática é dificilmente abordada em trabalhos correlatos a pesquisa, no entanto através dos resultados observou-se que esses dispositivos podem influenciar na respostas dos elementos de proteção implementados nos SDs. Como diferencial também buscou-se implementar todo o sistema de controle dos GDs e utilizou-se da simulação em malha fechada com relés comerciais, afim de aproximar a modelagem da realidade encontrada nos SDs. Por fim, evidenciou-se que a utilização de relés adaptativos pode viabilizar a operação em ilhamento. / The protection of Distribution Systems (DSs) is of fundamental importance, considering the adverse operating conditions and electrical faults to which they may be submitted. The increasing usage of Distributed Generators (DGs) connected to DSs, and possible islanded operations promote considerable interference to protective devices. Thus, it is evident the importance of studies for these new scenarios.This research aims to analyze the performance of the protection system, when in the presence of a massive contribution of distributed generation, and to improve the traditional protection when there is a change from the operating scenario to island mode. Thus, via simulations, carried out in the Real-Time Digital Simulator (RTDS), the effects of the disturbance on the Overcurrent Relays (OCs) were evident. The developed methodology implements an adaptive protection system, whose parameters are defined by an optimization algorithm. The protections associated with DGs were also added, as recommended by the standard. This practice is hardly approached in related studies however, through the results, it was observed that these devices could influence the responses of the protective elements implemented. The closed-loop simulations carried out considering the standard controls systems regarding DGs and commercial intelligent eletronic devices, ensuring the test bed verisimilitude to actual DSs. This approach is not standard on the literature related. Finally, it was evidenced that the use of adaptive relays can contribute to the islanded operation.
2

Metodologia híbrida para alocação, coordenação, dimensionamento e adequação do sistema de proteção em sistemas de distribuição de energia elétrica com geração distribuída diretamente acoplada / Hybrid methodology for protection system placement, sizing, coordination and adequation in electric distribution systems with directly coupled distributed generation

Guarda, Fernando Guilherme Kaehler 01 February 2017 (has links)
This work aims to allocate, size and coordinate protective devices in electric power systems with directly coupled distributed generation and also to adequate protection systems to accommodate these sources. Currently, it is possible to observe distributed generation penetration growth in distribution systems, being encouraged by new laws and implementation costs reduction, the last one due to technological maturity. Dispersed generation brings several benefits in electric networks operation such as: reduction of technical losses, voltage profiles maintenance, increase in energy quality, etc. However, this rise in distributed generation penetration in traditional distribution systems also causes important issues that must be considered. Distribution systems candidate to receive distributed generation have their protection systems already sized and coordinated. Distributed generation contribution alters the devices sensibility, causing miscoordination and the need for new protection studies. These problems are separately treated by authors, however, they are connected. In this work, the objective is to determine protective devices allocation and develop a solution to accommodate distribution generation. Firstly, the allocation, sizing and coordination of protective device is carried out, aiming to reduce reliability indices. Else, it was developed a method to reduce recloser - fuse miscoordination in the presence of distributed generation. To solve the miscoordination problem, Fault Current Limiters are sized and placed. These are inert devices in normal operation, but insert a high impedance in series with a feeder in a short circuit situation, limiting distributed generation contribution for a fault. The protective devices allocation problem is treated using a multiobjective particle swarm algorithm, aiming to reduce reliability indices, which priority is defined by the weight associated with each index. With the optimal protective devices placement established, distributed generation penetration is considered. Then, fault current limiters allocation and sizing is carried out to the best solutions of the protective devices allocation problem. To determine fault current limiters placement, a multiobjective particle swarm algorithm is also applied, aiming to reduce current differences due to distributed generation penetration, maintaining fuse cutout selectivity and also minimize fault current limiter size. The proposed method was tested in two IEEE test systems, presenting quality solutions for protective devices placement and also in adequating these systems to receive distributed generation. / Este trabalho tem o intuito de alocar, dimensionar, coordenar e adequar o sistema de proteção em redes de distribuição de energia elétrica na presença de fontes de geração distribuída (GD) diretamente acopladas à rede. Atualmente, é possível observar o crescimento na inserção de fontes de GD em sistemas de distribuição, sendo isso incentivado por novas legislações e pela redução no custo de implantação dessas fontes, devido à crescente maturidade tecnológica alcançada. A geração dispersa de energia traz diversos benefícios na operação da rede elétrica, podendo-se citar a redução de perdas técnicas, manutenção de perfis de tensão, aumento da qualidade de energia, entre outros. Porém, esse incremento na penetração da GD nas redes elétricas tradicionais também traz problemas que devem ser considerados. Um sistema de distribuição passível à inserção de fontes de GD, possuí dispositivos de proteção já alocados e sua coordenação determinada. A contribuição das fontes de GD para a corrente de falta altera a sensibilidade desses dispositivos, provocando diversas descoordenações e a necessidade de novos estudos de proteção. Esses problemas são tratados separadamente por pesquisadores, porém, são relacionados. Neste trabalho, buscou-se realizar a alocação de dispositivos de proteção e desenvolver uma solução para acomodar as fontes de GD. Primeiramente, é realizada a alocação, dimensionamento e coordenação dos dispositivos de proteção, visando a redução dos indicadores de continuidade responsáveis por avaliar quantitativamente a qualidade do serviço de energia elétrica. Aliado à isto, foi desenvolvido um método para reduzir a descoordenação entre dispositivos religadores e elos fusíveis na presença de GD. Para isso, foi considerada a instalação de Limitadores de Corrente de Falta (LCF), que são dispositivos que não causam interferência no sistema quando em funcionamento normal, porém, na ocorrência de um curto-circuito, inserem uma impedância considerável, limitando assim a contribuição da GD para a corrente de falta. O problema de alocação de dispositivos de proteção foi tratado utilizando algoritmo de enxame de partículas multiobjetivo, visando minimizar os indicadores de continuidade com sua prioridade definida pelo peso que cada um desses recebe do operador na função objetivo. Com as soluções obtidas, é considerada a inserção de fontes de GD no sistema. Então a alocação e dimensionamento de LCF é realizada para as melhores soluções obtidas de alocação de dispositivos de proteção. Para determinar essa alocação, o algoritmo de enxame de partículas multiobjetivo também foi utilizado, com o intuito de reduzir a diferença entre as correntes de falta com e sem GD, garantindo a seletividade entre elos fusíveis e a coordenação religador – elo fusível, bem como reduzir a dimensão do LCF (minimização do custo). Complementando o método, a filosofia operacional dos religadores é verificada, buscando evitar a contribuição da GD para faltas durante a operação rápida deste. O método proposto foi testado em dois sistemas IEEE, apresentando soluções de qualidade tanto na alocação dos dispositivos de proteção quanto na eficiência operacional do sistema de proteção em redes de distribuição com geração distribuída.
3

Identificação de faltas de alta impedância em sistemas de distribuição.

SANTOS, Wellinsílvio Costa dos. 07 May 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-07T20:46:33Z No. of bitstreams: 1 WELLINSÍLVIO COSTA DOS SANTOS – TESE (PPGEE) 2016.pdf: 10591682 bytes, checksum: 97299060f7fb8f9c7f837b25352da777 (MD5) / Made available in DSpace on 2018-05-07T20:46:33Z (GMT). No. of bitstreams: 1 WELLINSÍLVIO COSTA DOS SANTOS – TESE (PPGEE) 2016.pdf: 10591682 bytes, checksum: 97299060f7fb8f9c7f837b25352da777 (MD5) Previous issue date: 2016-08-15 / Capes / Uma técnica baseada em análise de transitórios eletromagnéticos é proposta para identificar faltas de alta impedância (FAI) em redes de distribuição. O algoritmo dispensa conhecimento dos parâmetros dos alimentadores e faz uso da transformada wavelet discreta (TWD) para monitorizar fenômenos transitórios associados a distúrbios no sistema de distribuição. A metodologia proposta é avaliada através de simulações em um programa de transitórios eletromagnéticos (EMTP) em um sistema de 13,8 kV, que foi modelado a partir de dados de uma rede de distribuição brasileira real. Além de FAI, foram simulados outros tipos de distúrbios, tais como faltas de baixa impedância, chaveamentos de novas linhas e bancos de capacitores. Os resultados obtidos demonstraram que o método é capaz de detectar a perturbação logo após o seu início e distingui-la de outros distúrbios, além de proporcionar uma redução significativa da região de localização da FAI. / An electromagnetic transient analysis-based technique is proposed to identify high impedance faults (HIF) in distribution networks. The algorithm dispenses knowledge of the feeder parameters and makes use of discrete wavelet transform (TWD) to monitor transient phenomena associated with disturbances in the distribution system. The proposed methodology is evaluated through simulations in an electromagnetic transient program (EMTP) in a 13.8 kV system, which was modeled from actual Brazilian distribution network data. Besides HIF, other types of disturbances were simulated, such as low impedance fault, and switching of lines and capacitor banks. Obtained results have shown that the method is able to detect the disturbance soon after its inception and distinguish it from other disorders, as well as providing a significant reduction in the region of its location for maintenance crews.

Page generated in 0.1772 seconds