• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Antal tvärsektioners påverkan på djupmodeller producerad av SeaFloor HydroLite ™ enkelstråligt ekolod : En jämförelse mot djupmodeller producerad av Kongsberg EM 2040P MKII flerstråligt ekolod

Hägg, Linnéa, Stenberg Jönsson, Simon January 2023 (has links)
Hydroakustiska mätningar har gjorts i nästan två hundra år. Det kan liknas med topografiska mätningar på land och visar hur sjö- eller havsbottnar ser ut. Idag används ekolod vilket är en teknik som skickar ut ljudvågor i vattnet för att mäta hur lång tid det tar för ljudet att studsa på bottnen och sedan komma upp till instrumentet igen. Därefter går det att räkna ut djupet med hjälp av ljudhastighetsberäkningar. Vid inmätning av enkelstråligt ekolod rekommenderas användande av tvärsektioner som kontroll av data. Flerstråligt ekolod behöver däremot inte tvärsektioner då övertäckning mellan stråken används som kontroll. I denna studie undersöks hur antalet tvärsektioner påverkar djupkartor skapade av Seafloor HydroLite TM enkelstråligt ekolod. Detta är även en undersökning av hur djupkartor producerade av SeaFloor HydroLite TM enkelstråligt ekolod skiljer sig mot djupkartor producerade av Kongsberg EM 2040 MK11 flerstråligt ekolod. Studieområdet är 1820 m2 och är beläget vid Forsbackas hamn i Storsjön, Gävle kommun. Vid inmätning av flerstråligt ekolod användes en övertäckning av lägst 50 %. Fem huvudstråk och sju tvärsektioner mättes med enkelstråligt ekolod för området. Djupkartor med olika antal tvärsektioner gjordes i Surfer 10 från enkelstråligt ekolod. Därefter jämfördes djupkartor av enkelstråligt ekolod mot kartor gjorda av data från flerstråligt ekolod för att se hur djupkartorna skiljer sig och för att se hur djupkartorna av enkelstråligt ekolod påverkas av olika antal tvärsektioner. Med användande av flerstråligt ekolod som referens mot djupkartor gjorda av enkelstråligt ekolod blev resultaten att RMS och standardosäkerhet minskar med 1 cm i RMS-värde och med 2 cm i standardosäkerhet. Jämförelse mellan ekolods systemen visar att skillnaden av djupvärderna är runt 10 cm. Slutsatserna från denna studie är att tvärsektioner endast förbättrar kvalitén på djupkartor marginellt vid jämn och enhetlig bottentopografi, men fyller en viktig funktion genom att kontrollera kvalitén av inmätningsdatat. Samt att SeaFloor HydroLite TM klarar av order 1b vid ett djup omkring en till fyra meter om ej kravet på full bottentäckning beaktas. Seafloor HydroLite TM skapar en översiktlig djupkarta medan djupmodellerna från Kongsberg EM 2040 MKII ser mera detaljer. / Hydroacoustic measurements have been conducted for almost two hundred years. It can be compared to topographic measurements on land and shows the appearance of lake or ocean floors. Today, echosounders are used, which is a technique that sends out sound waves into the water to measure the time it takes for the sound to bounce off the bottom and return to the instrument. Sound velocity calculations can then be used to calculate the depth. The use of cross-sections is recommended as a data control of single beam echosounder. However, multi beam echosounders only use overlap as control. This study examines how the number of cross-sections affects depth maps created by Seafloor HydroLite TM single beam echosounder. It also investigates the differences between depth maps produced by the SeaFloor HydroLite TM single beam echosounder and the Kongsberg EM 2040 MK11 multi beam echosounder. The study area covers 1820 m2 and is located at Forsbackas Harbor in Storsjön, Gävle municipality. A minimum overlap of 50% was used for the surveying with the multi beam echosounder. Five main lines and seven cross-sections were measured using the single beam echosounder. Depth maps with different numbers of cross-sections were created using data from the single beam echosounder. The maps from the single beam echosounder were compared to maps created from the data obtained by the multi beam echosounder to assess the differences and the impact of varying numbers of cross-sections on the depth maps from the single beam echosounder. By using the multi beam echosounder as a reference for the depth maps created by the single beam echosounder, the results showed a decrease of 1 cm in RMS value and 2 cm in standard deviation. The comparison between the echosounder systems revealed a difference of around 10 cm in depth values. The conclusions from this study are that cross-sections only marginally improve the quality of depth maps in cases of even and uniform bottom topography but serve an important function in validating the quality of the survey data. Additionally, the SeaFloor HydroLite TM is capable of meeting Order 1b at depths ranging from one to four meters if the requirement for full bottom coverage is not considered. The Seafloor HydroLite TM creates a general overview of the depth map, while the depth models from the Kongsberg EM 2040 MKII provide more detailed information.
2

Modulating Depth Map Features to Estimate 3D Human Pose via Multi-Task Variational Autoencoders / Modulerande djupkartfunktioner för att uppskatta människans ställning i 3D med multi-task-variationsautoenkoder

Moerman, Kobe January 2023 (has links)
Human pose estimation (HPE) constitutes a fundamental problem within the domain of computer vision, finding applications in diverse fields like motion analysis and human-computer interaction. This paper introduces innovative methodologies aimed at enhancing the accuracy and robustness of 3D joint estimation. Through the integration of Variational Autoencoders (VAEs), pertinent information is extracted from depth maps, even in the presence of inevitable image-capturing inconsistencies. This concept is enhanced through the introduction of noise to the body or specific regions surrounding key joints. The deliberate introduction of noise to these areas enables the VAE to acquire a robust representation that captures authentic pose-related patterns. Moreover, the introduction of a localised mask as a constraint in the loss function ensures the model predominantly relies on pose-related cues while disregarding potential confounding factors that may hinder the compact representation of accurate human pose information. Delving into the latent space modulation further, a novel model architecture is devised, joining a VAE and fully connected network into a multi-task joint training objective. In this framework, the VAE and regressor harmoniously influence the latent representations for accurate joint detection and localisation. By combining the multi-task model with the loss function constraint, this study attains results that compete with state-of-the-art techniques. These findings underscore the significance of leveraging latent space modulation and customised loss functions to address challenging human poses. Additionally, these novel methodologies pave the way for future explorations and provide prospects for advancing HPE. Subsequent research endeavours may optimising these techniques, evaluating their performance across diverse datasets, and exploring potential extensions to unravel further insights and advancements in the field. / Human pose estimation (HPE) är ett grundläggande problem inom datorseende och används inom områden som rörelseanalys och människa-datorinteraktion. I detta arbete introduceras innovativa metoder som syftar till att förbättra noggrannheten och robustheten i 3D-leduppskattning. Genom att integrera variationsautokodare (eng. variational autoencoder, VAE) extraheras relevant information från djupkartor, trots närvaro av inkonsekventa avvikelser i bilden. Dessa avvikelser förstärks genom att applicera brus på kroppen eller på specifika regioner som omger viktiga leder. Det avsiktliga införandet av brus i dessa områden gör det möjligt för VAE att lära sig en robust representation som fångar autentiska poseringsrelaterade mönster. Dessutom införs en lokaliserad mask som en begränsning i förlustfunktionen, vilket säkerställer att modellen främst förlitar sig på poseringsrelaterade signaler samtidigt som potentiella störande faktorer som hindrar den kompakta representationen av korrekt mänsklig poseringsinformation bortses ifrån. Genom att fördjupa sig ytterligare i den latenta rumsmoduleringen har en ny modellarkitektur tagits fram som förenar en VAE och ett fullständigt anslutet nätverk i en fleruppgiftsmodell. I detta ramverk påverkar VAE och det fullständigt ansluta nätverket de latenta representationerna på ett harmoniskt sätt för att uppnå korrekt leddetektering och lokalisering. Genom att kombinera fleruppgiftsmodellen med förlustfunktionsbegränsningen uppnår denna studie resultat som konkurrerar med toppmoderna tekniker. Dessa resultat understryker betydelsen av att utnyttja latent rymdmodulering och anpassade förlustfunktioner för att hantera utmanande mänskliga poser. Dessutom banar dessa nya metoder väg för framtida utveckling inom uppskattning av HPE. Efterföljande forskningsinsatser kan optimera dessa tekniker, utvärdera deras prestanda över olika datamängder och utforska potentiella tillägg för att avslöja ytterligare insikter och framsteg inom området.

Page generated in 0.0204 seconds