• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utilização de Doppler como fator prognóstico e suas correlações com marcadores imunoistoquímicos no mastocitoma cutâneo canino

Costa, Sabrina dos Santos [UNESP] 11 November 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-11-11Bitstream added on 2014-06-13T19:41:10Z : No. of bitstreams: 1 costa_ss_dr_botfmvz.pdf: 1745465 bytes, checksum: 6163d7d6432dccda5910a889a705ab7b (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O mastocitoma (MCT) cutâneo é uma das neoplasias malignas mais comuns em cães, representa 11% dos tumores de pele nesta espécie e apresenta comportamento biológico variável. Este trabalho dá continuidade a pesquisas com biomarcadores prognósticos em MCTs cutâneos em cães. Foi realizado um estudo em busca de critérios complementares ao exame clínico (ultrassonografia pelo método Doppler), que auxiliem na determinação do potencial de recidiva e metástase do tumor, correlacionando-os com a expressão da proteína KIT, densidade microvascular (DMI), tamanho, número de tumores, tempo de evolução, ulceração, tempo de sobrevida e graduação histopatológica. Além disso, foi realizada uma análise dos parâmetros clínicos, incluindo dados epidemiológicos, achados histológicos e moleculares e a correlação destes com o comportamento biológico do MCT. Foram avaliados 20 cães, que totalizaram 28 tumores. A ultrassonografia (US) pelo método Doppler permitiu a identificação de vasos em 54% dos tumores. Não houve correlação entre a presença de vasos e a DMI, a localização da proteína KIT, os graus histológicos, o tempo de evolução, o tamanho, a ocorrência de recidivas e metástases, e o tempo de sobrevida, mas sim com a presença de ulceração tumoral. Observou-se correlação estatística entre o grau histológico, a DMI, a presença de ulceração e o número de tumores e também da expressão de Ki-67 com os padrões de marcação da proteína KIT. O grau histológico no MCT cutâneo canino não deve ser avaliado isoladamente, mas sim em conjunto com a expressão da proteína KIT, DMI, proliferação celular, presença de ulceração, número de tumores e ocorrência de recidivas e metástases. Indicamos que estudos adicionais... / Cutaneous mast cell tumor (MCT) is one of the most common malignant neoplasms in dogs, representing 11% of skin tumors in this species and shows a variable biological behavior. This article maintains the search on prognostic biomarkers in cutaneous MCTs in dogs. A study was conducted to find additional criteria to the clinical examination (Doppler ultrasound) to add in determining the potential for recurrence and metastasis of tumors, correlating them with KIT protein expression, intratumoral microvessel density (IMD), size, number of tumors, duration time, ulceration, survival rates and histological classification. In addition, we performed an analysis of clinical parameters, including epidemiological data, histological and molecular ones and correlate them with the biological behavior of MCT. We evaluated 20 dogs, in a total of 28 tumors. The Doppler ultrasound (US) allowed the identification of vessels in 54% of tumors. There was no correlation between the presence of vessels and IMD, KIT protein location, histological grades, duration time, tumor size, recurrence and metastasis, and survival rates, but with ulceration. We have observed statistical correlation between histological grade, IDM, presence of ulceration and number of tumors and also the expression of Ki-67 with patterns of KIT protein. The histological grade in canine cutaneous MCT should not be assessed in isolation but in conjunction with expression of KIT protein, IDM, cell proliferation, presence of ulceration, number of tumors and recurrences and metastases rates. We suggest that additional studies should be done to further evaluate the use of Doppler US as a noninvasive method to chacarterize the vascularization and blood flow in... (Complete abstract click electronic access below)
2

Processamento de sinais Doppler para obtenção de sonograma em tempo real

Baggio, João Fernando Refosco January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T20:48:39Z (GMT). No. of bitstreams: 1 195465.pdf: 1562512 bytes, checksum: 8a74f5600fbb13f8bf0569fe7bf2cf80 (MD5) / A aterosclerose reduz a luz de vasos sanguíneos, causando isquemia. Para manter a irrigação distal à lesão, realizam-se cirurgias de reconstrução vascular que estabelecem um caminho alternativo para o fluxo do sangue. A monitoração pós-operatória de cirurgias de reconstrução vascular periférica é de grande importância para a detecção de possíveis erros técnicos. Tais erros podem ter como consequência a amputação do membro afetado ou mesmo, a morte do paciente. O diagnóstico prematuro destas falhas possibilita uma segunda intervenção para correção do problema. Pesquisas vêm sendo realizadas para o emprego de parâmetros quantitativos para avaliar o sucesso de cirurgia de reconstrução vascular. Estes parâmetros são obtidos a partir de formas de onda do fluxo sanguíneo amostradas com ultra-som Doppler. Visando construir um sistema versátil que possa contribuir para com estas investigações, este trabalho aborda o desenvolvimento de software para aquisição, registro e processamento de sinais Doppler. Estes sinais são gerados por uma placa de ultra-som Doppler de ondas contínuas. O programa computa o sonograma e as curvas de velocidade máxima e média velocidade, como também os exibe em tempo real na tela do PC. Buscando reduzir os custos e aumentar a flexibilidade de tais sistemas, o programa desenvolvido substitui Placa de Processamento Digital de Sinais inserido em slot do PC que vem sendo utilizada para realizar tais tarefas. A amostragem dos sinais é realizada com a Placa de Som existente em PCs comerciais. Bibliotecas otimizadas e técnicas de programação permitem realizar este processamento em tempo real. Como o sistema MS-Windows# não foi desenvolvido para aplicações em tempo real, este trabalho discute as técnicas utilizadas para garantir os resultados obtidos.
3

Utilização de Doppler como fator prognóstico e suas correlações com marcadores imunoistoquímicos no mastocitoma cutâneo canino /

Costa, Sabrina dos Santos. January 2011 (has links)
Orientador: Renée Laufer Amorim / Coorientador: Carlos Roberto Daleck / Banca: Mirela Tinucci Costa / Banca: Sabryna Gouveia Calazans / Banca: Luiz Henrique de Araújo Machado / Banca: Renata Alonso Sobral / Resumo: O mastocitoma (MCT) cutâneo é uma das neoplasias malignas mais comuns em cães, representa 11% dos tumores de pele nesta espécie e apresenta comportamento biológico variável. Este trabalho dá continuidade a pesquisas com biomarcadores prognósticos em MCTs cutâneos em cães. Foi realizado um estudo em busca de critérios complementares ao exame clínico (ultrassonografia pelo método Doppler), que auxiliem na determinação do potencial de recidiva e metástase do tumor, correlacionando-os com a expressão da proteína KIT, densidade microvascular (DMI), tamanho, número de tumores, tempo de evolução, ulceração, tempo de sobrevida e graduação histopatológica. Além disso, foi realizada uma análise dos parâmetros clínicos, incluindo dados epidemiológicos, achados histológicos e moleculares e a correlação destes com o comportamento biológico do MCT. Foram avaliados 20 cães, que totalizaram 28 tumores. A ultrassonografia (US) pelo método Doppler permitiu a identificação de vasos em 54% dos tumores. Não houve correlação entre a presença de vasos e a DMI, a localização da proteína KIT, os graus histológicos, o tempo de evolução, o tamanho, a ocorrência de recidivas e metástases, e o tempo de sobrevida, mas sim com a presença de ulceração tumoral. Observou-se correlação estatística entre o grau histológico, a DMI, a presença de ulceração e o número de tumores e também da expressão de Ki-67 com os padrões de marcação da proteína KIT. O grau histológico no MCT cutâneo canino não deve ser avaliado isoladamente, mas sim em conjunto com a expressão da proteína KIT, DMI, proliferação celular, presença de ulceração, número de tumores e ocorrência de recidivas e metástases. Indicamos que estudos adicionais... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Cutaneous mast cell tumor (MCT) is one of the most common malignant neoplasms in dogs, representing 11% of skin tumors in this species and shows a variable biological behavior. This article maintains the search on prognostic biomarkers in cutaneous MCTs in dogs. A study was conducted to find additional criteria to the clinical examination (Doppler ultrasound) to add in determining the potential for recurrence and metastasis of tumors, correlating them with KIT protein expression, intratumoral microvessel density (IMD), size, number of tumors, duration time, ulceration, survival rates and histological classification. In addition, we performed an analysis of clinical parameters, including epidemiological data, histological and molecular ones and correlate them with the biological behavior of MCT. We evaluated 20 dogs, in a total of 28 tumors. The Doppler ultrasound (US) allowed the identification of vessels in 54% of tumors. There was no correlation between the presence of vessels and IMD, KIT protein location, histological grades, duration time, tumor size, recurrence and metastasis, and survival rates, but with ulceration. We have observed statistical correlation between histological grade, IDM, presence of ulceration and number of tumors and also the expression of Ki-67 with patterns of KIT protein. The histological grade in canine cutaneous MCT should not be assessed in isolation but in conjunction with expression of KIT protein, IDM, cell proliferation, presence of ulceration, number of tumors and recurrences and metastases rates. We suggest that additional studies should be done to further evaluate the use of Doppler US as a noninvasive method to chacarterize the vascularization and blood flow in... (Complete abstract click electronic access below) / Doutor
4

Sistema ultra-sonico dopler pulsatil para medição de fluxo sanguineo em circulação extracorporea

Dantas, Ricardo Grossi, 1974- 22 April 1999 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T08:36:04Z (GMT). No. of bitstreams: 1 Dantas_RicardoGrossi_M.pdf: 7105342 bytes, checksum: 54d821c8ddbe041c7401811d9837aee2 (MD5) Previous issue date: 1999 / Resumo: Em operações cardíacas, freqüentemente há a necessidade de se realizar intervenções em estruturas internas do coração, e a circulação e oxigenação do sangue são feitas por meios artificiais, fora do corpo do paciente, em um procedimento denominado circulação extracorpórea (CEC) ou "bypass" cardio-pulmonar. Durante uma rotina de CEC, um dos parâmetros mais importantes, e que exige constante monitoração, é o fluxo sangüíneo. Em muitos casos, são utilizados estimadores de fluxo baseados na velocidade de rotação das bombas (peristálticas) ou medidores que utilizam o princípio eletromagnético (bombas peristálticas ou centrífugas). Estes métodos são de tecnologia bastante difundida, mas nem sempre confiáveis para sistemas de CEC, em função de suas características intrínsecas. Neste trabalho, foi desenvolvido um medidor de fluxo sangüíneo baseado no sistema ultra-sônico Doppler pulsátil destinado a sistemas de circulação extracorpórea. Foi utilizado um transdutor de 2MHz, medindo vazões de O a 5 litros/min, acoplado externamente à linha arterial de tubulação de CEC destinada à perfusão de adultos (9,53mm de diâmetro), com a vantagem de não entrar em contato com o sangue do paciente. Este medidor apresenta o valor do fluxo em um indicador numérico de 2 dígitos, disponibilizando esta informação também de forma analógica ou digital, esta última com resolução de 8 bits. Testes realizados indicaram um desvio máximo de 3,5% do fundo de escala. Este medidor fornece resultados de forma contínua e confiável, e não apresenta as limitações encontradas nos outros métodos. Além disso, pelo fato de não haver contato com o sangue, ele não é descartável e não necessita de esterilização, reduzindo custos operacionais e viabilizando seu uso / Abstract: : In cardiac surgeries it is frequently necessary to carry out interventions in internal heart structures, and where the blood circulation and oxygenation are made by artificial ways, out of the patient' s body, in a procedure known as extracorporeal circulation (EC) or heart-lung bypass. During an EC procedure, one of the most important parameters, and that demands constant monitoring, is the blood flow. Quite often, blood flow estimators based in the pump rotation speed (for peristaltic pumps) or those using the electromagnetic principle (for peristaltic or centrifugal pumps) are used. The technology available for these methods is relatively well known, but not very reliable for EC systems due to their intrinsic characteristics. In this work, an ultrasonic pulsed Doppler blood flowmeter, to be used in an extracorporeal circulation system, was developed. It was used a 2MHz ultrasonic transducer, measuring flows from 0 to 5 liters/min, coupled externally to the EC arterial line destined to adults perfusion (diameter of 9.53mm or 3/8"), with the advantage of not entering in contact with the patient blood. This flowmeter presents the flow value in a 2 digit numerical display, allowing this information to be used both in analog and digital forms (8 bits resolution). The results indicated a maximum deviation of3.5% of full scale. This flowmeter supplies the results in a continuous and trustworthy way, and it does not present the limitations found in those flowmeters based in other transduction methods. Moreover, due to the fact of not being in contact with the blood, it is not disposable and it does not need sterilization, reducing operational costs and facilitating its use / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
5

Projeto de um sistema ultra-sonico doppler pulsatil para avaliação da vascularização periferica

Gamba, Humberto R 09 June 1989 (has links)
Orientador : Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T20:51:19Z (GMT). No. of bitstreams: 1 Gamba_HumbertoR_M.pdf: 9020235 bytes, checksum: f58f0f0b6af91cdd429e14d1ee2e9ab9 (MD5) Previous issue date: 1989 / Resumo: A utilização de sistemas ultra-sônicos, baseados no princrpio Doppler, para detecção de estenoses arteriais, constitui uma área de grande interesse no diagnóstico médico. Os equipamentos de fabricação nacional para esta finalidade trabalham com emissão e recepção de ultra-som no modo contínuo. Devido à esta característica, estes sistemas só conseguem detectar a existência de turbulências produzidas por obstruções que comprometem praticamente 50 % da luz do vaso. Os Com a finalidade de detectar a presença de turbulências produzidas por estenoses de pequeno grau (menores que 30%), projetou-se e construiu-se a primeira parte de um sistema ultra-sônico Doppler pulsátiI de múltiplos canais. O protótipo, embora ainda com apenas um canal , é capaz de analisar lâminas de fluxo com espessura de aproximadamente 2,3 mm (ângulo de incidência de 75 graus) em profundidades de até 70 mm. Seu sistema de controle permite a ampliação até o máximo de 15 canais. O transdutor utilizado neste equipamento possui um único cristal, tanto para emissão quanto para recepção, emitindo pulsos ultra-sônicos de 5 MHz em intervalos fixos de 50 µ ou 100 , sendo a duração de cada pulso ajustável entre 0,1 e 1 µ . Os resultados obtidos com este primeiro protótipo, demonstram a capacidade do sistema em detectar turbulências produzidas por obstruções de até 22 % de comprometimento da luz do vaso / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
6

Desenvolvimento e aplicação de sistema para obtenção de imagens acústicas pelo método do beamforming para fontes em movimento

Fonseca, William D'Andrea January 2009 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2009. / Made available in DSpace on 2012-10-24T09:49:50Z (GMT). No. of bitstreams: 1 267094.pdf: 208789903 bytes, checksum: 344e69fc3816d5727d93dc2277f1e4e0 (MD5) / Com a evolução das técnicas de avaliação de ruído foi possível criar mapas de imagens acústicas que determinam com maior precisão as regiões de ruído proeminente; esse é o princípio básico da técnica de beamforming. Estendendo-se a técnica para fontes em movimento, é possível fazer o mesmo tipo de avaliação, e localizar assim as fontes que são geradas por efeitos do movimento, como: rolamento de um carro ou as turbulências do ar geradas por um avião. O trabalho desenvolvido compreende toda a implementação do sistema de beamforming para que as medições de fontes móveis fossem possíveis. Isso inclui a construção, calibração e validação dos microfones e do array que os sustenta. Na aplicação para fontes em movimento, o direcionamento do trabalho visou a uma aplicação prática e real. Nesse sentido, o teste de Pass-by Noise regulamentado para medição veicular foi utilizado como base para as medições de fontes em movimento. De forma sucinta, esse trabalho demonstra uma breve revisão teórica a respeito dos fundamentos de acústica, processamento de sinais e Efeito Doppler, baseando-se nas referências. Desse modo, a cadeia de medição utilizada é apresentada e validada. Em sequência a isso, são apresentados os métodos de medição e análise, bem como os resultados do beamforming para o ruído de passagem de veículos.
7

Método Doppler de posicionamento por satélites NNSS

Romao, Verônica Maria Costa January 1982 (has links)
Reproduçao eletrostatica / Orientador: José Bittencourt de Andrade / Dissertaçao (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Terra, Programa de de Pós-Graduação em Ciências Geodésicas / Bibliografia: f. 122-126 / Resumo: O objetivo deste trabalho descrever os princípios do método de posicionamento Doppler que utiliza o U . S . Navy Navigation Satellite System (NNSS) desenvolvido pelo U.S. Applied Physics Laboratory. Também é introduzida uma revisão sobre alguns modelos matemáticos utilizados na transformação de sistemas geodésicos, com o objetivo de uma futura determinação dos parâmetros que interligam os sistemas Doppler e o Datum Sul Americano - 1969 (DSA-69) e dos erros sistemáticos não solucionados da rede de triangulação brasileira. / Abstract:The purpose of this thesis is to describe the basic principles of the Doppler satellite positioning method which utilizes the U.S. Navy Navigation Satellite System ( N N S S ). developd by the U.S. Applied Physics Laboratory. Also, the thesis offers an extensive review of the literature concerning some mathematical models used in the trans formation of geodetic systems, with the objective of determining the parameters that connect the Doppler system with the South American Datum (SAD-69) and obtaining the unsolved systematic errors of the Brazilian tri angul ati on network.
8

Analise da dopplervelocimetria feto-placentaria em gestantes hipertensas e resultados perinatais segundo a idade gestacional

Ferreira Neto, Pedro Pires 14 December 2006 (has links)
Orientador: Anibal Faundes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-08T03:02:55Z (GMT). No. of bitstreams: 1 FerreiraNeto_PedroPires_D.pdf: 756822 bytes, checksum: 391b94a37ae61d1eb12c2c4f4b8aeacb (MD5) Previous issue date: 2006 / Resumo: Objetivo: Avaliar a capacidade dos índices de pulsatilidade das artérias umbilical e cerebral média e a relação do índice de pulsatilidade umbilico-cerebral em fetos de gestantes hipertensas de predizer risco de resultados perinatais adversos de acordo com a idade gestacional. Métodos: No período de janeiro de 2000 a agosto de 2004 foi realizada a avaliação dopplervelocimétrica dos índices de pulsatilidade da artéria umbilical (IPAU), da artéria cerebral média (IPACM) e da relação do índice de pulsatilidade umbilical/cerebral (IPAU/IPACM) de 289 gestantes com hipertensão artérial, com idade gestacional entre 24 a 41 semanas de gestação. Os resultados doplervelocimétricos que apresentaram IPAU acima do percentil 95 ou fluxo diastólico ausente ou reverso, IPACM abaixo do percentil 5 e relação IPAU/IPACM acima do percentil 95, foram avaliados quanto à capacidade de prever resultados perinatais adversos (Apgar do 5º minuto < 7, recém-nascido pequeno para a idade gestacional (RN PIG), ocorrência da doença da síndrome do desconforto respiratório (SDR), ocorrência da síndrome hipóxico-isquêmica (SHI) e óbito perinatal. Estes resultados foram comparados entre si sem ajuste e com ajuste pela idade gestacional no parto. Resultados: Os resultados alterados da dopplervelocimetria não estiveram associados ao risco de Apgar do 5º minuto < 7, antes de ajustar por idade gestacional. Com o ajuste, o risco aumentou. Entretanto, apenas a associação com alteração do IPAU alcançou significação estatística. O risco de ocorrência de recém-nascido PIG aumentou entre cinco e sete vezes na análise sem ajuste e em torno de três vezes na análise ajustada, e foi estatisticamente significativa para todos os parâmetros da dopplervelocimetria estudados. O risco de SHI aumentou entre duas e cinco vezes antes do ajuste. O aumento do risco ajustado foi significativo apenas para IPAU e relação IPAU/IPACM. Quanto ao risco da SDR houve aumento de duas a seis vezes na análise sem ajuste, mas na análise ajustada não houve aumento. Na análise da mortalidade perinatal o risco não ajustado foi entre três e dez vezes maior, nos casos com alteração do IPAU, IPACM e na relação IPAU/IPACM. Na análise ajustada apenas o IPAU alterado apresentou associação com risco quase três vezes maior e foi estatisticamente significativo. Conclusão: Neste grupo selecionado de gestantes hipertensas, a análise isolada do IPAU apresentou melhor correlação com os resultados perinatais do que a análise do IPACM ou da relação IPAU/IPACM, particularmente quando a análise foi feita com o ajuste da idade gestacional / Abstract: Objetive: To evaluate the capacity of the pulsatility Index of the umbilical artery and of the median cerebral artery and of the umbilical/cerebral ratio to predict adverse perinatla outcomes. Métodos: Dopplervelocimetric evaluation of the pulsatility Index of the umbilical artery (IPAU) and of the Median cerebral artery (IPACM) and of the umbilical/cerebral ratio (IPAU/IPACM) was carried out 289 pregnant women with hypertension at 24 through 41 weeks of gestation. Abscent or reverse diastolic flux and, IPAU above the 95 percentil, IPACM below percentil 10 and IPAU/IPACM ratio over the 95 percentil were evaluated in relation to its associasaion with adverse perinatal outcomes (5 minutes Apgar score < 7, small for gestational age (PIG), hialine membrane disease (DMH), hipoxic ischemic syndrome (SHI) and perinatal death. These results were compare before and after adjustment by gestational age at birth. Results: Abnormal Doppler results were not associated with the risk of 5 minutes Apgar score < 7 before adjustment by gestational age. After adjustment the risk increased, but only adnormal IPAU was significantly associated with. 5 minutes Apgar score < 7. The risk of PIG was 5 to 7 times higher before adjustment and arround 3 times and significantly higher after adjustment in cases with alterations in any of the three Doppler indicators studied. The risk of SHI was increased between 2 and 5 times before adjustment, but after adjustment the risk was significantly higher when the IPAU and the IPAU/IPACM ratio were adnormal. The risk DMH appeared to be between 2 and 6 times higher before adjustment, but became insignificant for the three indicators after adjustment. The risk of perinatal death before adjustment was between 3 and 10 times higher in cases with alteration in the IPAU, IPACM and the IPAU/IPACM ratio. After adjustment, only adnormal IPAU was associated with a three folds increase risk, that was statistiocally significant. Conclusion: In this selected group of preganat women with hypertension the isolated analysys of IPAU showed the best correlation with adverse perinatal outcomes, particularly after adjustment by gestational age / Doutorado / Tocoginecologia / Doutor em Tocoginecologia

Page generated in 0.0742 seconds