• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 19
  • 8
  • 1
  • 1
  • Tagged with
  • 78
  • 43
  • 34
  • 18
  • 17
  • 15
  • 14
  • 12
  • 10
  • 9
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Optimization of the MgS:Eu:Sm phosphor for potential use as an optically stimulated personnel dosimeter

Hill, Michael David January 1988 (has links)
Magnesium sulfide activated with europium and samarium is a candidate phosphor for laser stimulated personnel dosimeters. Optically stimulated luminescence (OSL) dosimeters are advantageous in that they provide a faster, isothermal dose measurement than conventional thermoluminescent dosimeters. The effects of activator concentration and chemical substituents are examined in order to increase OSL intensity, improve the OSL emission wavelength and to increase the chemical stability of the MgS lattice. In addition, UV photoluminescence and thermoluminescence of the MgS:Eu:Sm phosphor was investigated to improve the understanding of the optical processes in MgS:Eu:Sm phosphors. / Master of Science
22

Evaluation of plastic scintillator and high-purity germanium detectors for use in beta spectroscopy

Stuewe, Robert Brian January 2011 (has links)
Typescript (photocopy). / Digitized by Kansas Correctional Industries
23

Evaluation of a four-element beta gamma personnel dosimetry badge

Tietze, Lorrie R. January 1985 (has links)
Call number: LD2668 .T4 1985 T53 / Master of Science
24

Estudo das respostas de TLD tipo LiF para caracterização de campos mistos / LiF TLD response study for mixed fields characterization

Paiva, Fabio de 24 March 2016 (has links)
A Terapia por Captura de Nêutrons, NCT (Neutron Capture Therapy) é uma técnica radioterápica em que a energia útil do tratamento vem da energia liberada em uma reação nuclear e não do feixe primário, como comumente utilizado em outros procedimentos radioterápicos. O Boro, por constituir-se em um elemento de baixa toxicidade e por apresentar um isótopo (10B) com alta seção de choque para a reação 10B(n,α)7Li tem sido o elemento mais utilizado nas pesquisas que visam o aprimoramento e a promoção desta técnica, derivando daí o termo BNCT (Boron Neutron Capture Therapy). Para fins de pesquisa em BNCT foi construída ao longo de um dos extratores de feixes (BH - Beam Hole) do reator IEA-R1 uma instalação, onde filtros e moderadores são posicionados entre o núcleo do reator e a posição de irradiação com o objetivo de modular o feixe de irradiação, otimizando a componente útil do feixe, os nêutrons térmicos, e reduzindo os contaminantes, raios gama e nêutrons em outras faixas energéticas. Tem-se realizado estudos visando a implementação de melhorias na caracterização e otimização do feixe obtido nesse arranjo instalado no BH-3. Atualmente a monitoração dos nêutrons é feita através de folhas de ativação, e a componente gama pelo TLD-400. Uma nova metodologia de monitoração tem sido estudada pelo grupo. A referida técnica consiste em usar TLDs de tipos diferentes, ou seja, que possuam sensibilidades distintas aos nêutrons térmicos, em virtude de diferenças na concentração dos isótopos de Lítio. No estudo dessa nova metodologia têm sido usados os TLD-600 e TLD-700. Este trabalho propõe uma metodologia usando o par TLD-100 e TLD-700. Inicialmente foi verificada a reprodutibilidade das respostas dos TLDs 700, 400 e 100 frente a campos gama puro e campos mistos, gama e nêutron. Campos estes obtidos em arranjos usando fontes de 60Co e 241AmBe. A partir de simulações usando o VI MCNP5 foi projetado e construído um Irradiador de campos mistos, que permitiu expor os dosímetros em campos mistos com diferentes espectros energéticos. As condições criadas no irradiador permitiram verificar, como a resposta do TLD é modificada pelas mudanças no espectro energético de um campo misto gama e nêutrons de baixo fluxo. O irradiador de campo misto permitiu condições para estabelecer uma relação entre o formato da curva termoluminescente e a composição do campo misto. A relação estabelecida relaciona o fluxo relativo e a razão entre a resposta das duas regiões de interesse dos TLDs 700 e 100. A partir de campos mistos com condições controladas, esse trabalho permitiu verificar a viabilidade do uso do par de TLD-100 e TLD-700 para monitoração de nêutrons térmicos na instalação de BNCT. / Neutron Capture Therapy (NCT), is a radiotherapy technique in which the useful treatment energy comes from the energy released in a nuclear reaction and not from the primary beam, as commonly used in other radiotherapc procedures. Boron, an element of low toxicity presents an isotope (10B) with high cross-section for the (n, α) reaction and therefore has been the element mostly used in research aimed at the improvement and promotion of this technique, deriving hence the term BNCT (Boron Neutron Capture Therapy). For BNCT research purposes, a facility was built along one of radiation extractors of the IEA-R1 reactor. In this facility filters and moderators are positioned between the reactor core and the irradiation position aiming to modulate the irradiation beam by optimizing the useful component of the beam, thermal neutrons, and reducing its contaminants, gamma rays and neutrons in higher energy bands. We have conducted studies aimed at implementing improvements in the characterization of and optimization of the beam. Currently, neutron flux monitorion is done through activation foils, and the gamma component by TLD-400. A new methodology has been studied by the group. The technique consists in using different types of TLD, having different sensitivities to thermal neutrons due to differences in the concentration of lithium isotopes. In the study of this new methodology TLD 600 and TLD-700 have been used. This work presents a series of studies in order to apply a methodology using the TLD-100 and TLD-700 pair. TLDs 700, 400 and 100 responses pure gamma and mixed irradiation fields, obtained in arrangements using a 60Co and AmBe sources, were evaluaterd. MCNP simulations were run in order to both discriminating the radiation components and designing one mixed fields irradiator, which allowed exposing dosimeters in mixed fields with different energy spectra. The conditions created in the irradiator allowed to verify, as the TLD response is modified by changes in the energy spectrum of a mixed gamma neutron fields. VIII This irradiator provided irradiation conditions so to establish a relationship between the shape of the LiF glow curves and the composition of the mixed field. This work has shown the feasibility of using the TLD-100 and TLD-700 pair for gamma and thermal neutrons monitoration in the BNCT facility.
25

Avaliação de dosímetros termoluminescentes empregando objetos simuladores equivalentes à água para aplicação na dosimetria de feixes clínicos de elétrons / Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

Bravim, Amanda 26 January 2011 (has links)
A dosimetria em Radioterapia prevê a calibração do feixe de radiação e a dosimetria de rotina para controle de qualidade, pois o seu principal objetivo é determinar, com maior precisão, a dose absorvida pelo tumor. Este trabalho tem como objetivo avaliar o comportamento de três dosímetros termoluminescentes na dosimetria de feixes clínicos de elétrons. O desempenho de detectores de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN foi comparado com o de dois dosímetros comercialmente disponíveis pela Harshaw, ambos denominados TLD-100, porém com dimensões distintas. Os dosímetros foram caracterizados com a utilização de objetos simuladores de água, água sólida RMI-457 e PMMA em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV. Também foram realizadas medidas em feixes de fótons de 6 e 15 MV (2 e 5 MeV) apenas para comparação de resultados. As curvas de dose-resposta foram obtidas para a radiação gama do 60Co no ar e em condições de equilíbrio eletrônico e para feixes clínicos de fótons e elétrons nas profundidades de máxima dose. A sensibilidade, a reprodutibilidade, a eficiência intrínseca e a dependência energética dos dosímetros termoluminescentes foram estudadas. O CaSO4:Dy apresentou comportamento semelhante ao dos TLD-100 com uma vantagem em relação à sensibilidade para os feixes e doses de radiação estudados. Sendo assim, o dosímetro produzido pelo IPEN pode ser considerado uma nova alternativa para a dosimetria nos departamentos de Radioterapia. / The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO4: Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO4: Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments.
26

Avaliação de dosímetros termoluminescentes empregando objetos simuladores equivalentes à água para aplicação na dosimetria de feixes clínicos de elétrons / Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

Amanda Bravim 26 January 2011 (has links)
A dosimetria em Radioterapia prevê a calibração do feixe de radiação e a dosimetria de rotina para controle de qualidade, pois o seu principal objetivo é determinar, com maior precisão, a dose absorvida pelo tumor. Este trabalho tem como objetivo avaliar o comportamento de três dosímetros termoluminescentes na dosimetria de feixes clínicos de elétrons. O desempenho de detectores de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN foi comparado com o de dois dosímetros comercialmente disponíveis pela Harshaw, ambos denominados TLD-100, porém com dimensões distintas. Os dosímetros foram caracterizados com a utilização de objetos simuladores de água, água sólida RMI-457 e PMMA em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV. Também foram realizadas medidas em feixes de fótons de 6 e 15 MV (2 e 5 MeV) apenas para comparação de resultados. As curvas de dose-resposta foram obtidas para a radiação gama do 60Co no ar e em condições de equilíbrio eletrônico e para feixes clínicos de fótons e elétrons nas profundidades de máxima dose. A sensibilidade, a reprodutibilidade, a eficiência intrínseca e a dependência energética dos dosímetros termoluminescentes foram estudadas. O CaSO4:Dy apresentou comportamento semelhante ao dos TLD-100 com uma vantagem em relação à sensibilidade para os feixes e doses de radiação estudados. Sendo assim, o dosímetro produzido pelo IPEN pode ser considerado uma nova alternativa para a dosimetria nos departamentos de Radioterapia. / The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO4: Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO4: Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments.
27

Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom / Μετρήσεις της περιφερειακής ζώνης σε πέντε κλινικές περιπτώσεις ακτινοθεραπείας με ανιχνευτές Mosfet σε ανθρωπόμορφο ομοίωμα

Παπαθανάσης, Χαράλαμπος 19 January 2010 (has links)
In the current study, we present measurements of peripheral dose that is absorbed by specific radio-sensitive organs outside the radiation field for five clinical cases, and compare them with the corresponding values that are given by ISIS 3D Treatment Planning System, as well as with the values given by a software that can calculate peripheral doses called ‘Peridose’. The measurements were made with MOSFET dosimeters in anthropomorphic phantom. / Στην παρούσα εργασία, παρουσιάζουμε μετρήσεις της περιφερειακής δόσης που απορροφάται από συγκεκριμένα ακτινευαίσθητα όργανα εκτός του πεδίου ακτινοβόλησης για πέντε κλινικές περιπτώσεις, και τις συγκρίνουμε με τις αντίστοιχες τιμές που δίνονται από το ISIS 3D Treatment Planning System καθώς και από τις τιμές που δίνει ένα πρόγραμμα το οποίο μπορεί να υπολογίσει περιφερειακές δόσεις που λέγεται ‘Peridose’. Οι μετρήσεις έγιναν με δοσίμετρα MOSFET σε ανθρωπόμορφο ομοίωμα.
28

Estudo e levantamentos de parametros para dosimetria de fontes de Iodo-125 aplicadas em braquiterapia / Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy

MOURA, EDUARDO S. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:12Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
29

Desenvolvimento e estudo de materiais termoluminescentes baseados em óxido de alumínio para aplicação em dosimetria / Development and study of thermoluminescent materials based on aluminium oxide for dosimetry application

FUKUMORI, DAVID T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:58Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:11Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
30

Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico – VMAT / Application of the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques to determinate the isodose curves in a cancer treatment planning simulation using volumetric modulated arc therapy - VMAT

BRAVIM, AMANDA 02 September 2015 (has links)
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2015-09-02T12:47:25Z No. of bitstreams: 0 / Made available in DSpace on 2015-09-02T12:47:25Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.2875 seconds