• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 508
  • 90
  • 62
  • 51
  • 41
  • 34
  • 13
  • 9
  • 6
  • 6
  • 6
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 1039
  • 1039
  • 181
  • 178
  • 178
  • 162
  • 98
  • 82
  • 81
  • 79
  • 73
  • 68
  • 65
  • 64
  • 61
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Roles of polydadmacs, dithiocarbamates and activated carbons in formation of N-nitrosamine contaminants in water

Padhye, Lokesh Pradeep 12 May 2010 (has links)
N-Nitrosamines are an emerging group of disinfection byproducts characterized by high carcinogenic risks at ng/L levels and by their frequent detection in water and wastewater treatment systems in the U.S. and other parts of the world. The overall goal of this research is to achieve a better understanding of the roles of common nitrosamine precursors in leading to N-nitrosamine formation in water and wastewater treatment systems. The specific objectives of this research are: (a) To probe the mechanisms of nitrosamine formation from commonly employed water treatment polymers, particularly polyDADMACs, during ozonation, (b) To evaluate the role of dithiocarbamate compounds as nitrosamine precursors in reaction with common water disinfection oxidants, and (c) To investigate the potential enhancement effect of activated carbons (AC) to promote transformation of amines to nitrosamines and identify the involved reaction mechanism. Results of this research show that, upon ozonation, polyDADMACs may yield N-nitrosodimethylamine (NDMA) at levels up to two orders of magnitude higher than current advisory guidelines for NDMA. Radical pathways may be responsible for the degradation of the quaternary ammonium ring groups in polyDADMACs to release of dimethylamine (DMA). Detection of significant amounts of nitrite after ozonation of polyDADMACs and DMA suggests the potential role of nitrosation pathway in NDMA formation. Study results also reveal dithiocarbamates as potent nitrosamine precursors with significant nitrosamine yields upon ozonation and monochloramination. Identification and quantification of reaction products suggest nitrosation and chlorinated-UDMH oxidation as primary reaction mechanisms in nitrosamine formation from ozonation and monochloramination of dithiocarbamates compounds, respectively. This research also demonstrates that many commercial AC materials may catalyze transformation of secondary amines to yield trace levels of N-nitrosamines under ambient aerobic conditions. This is a novel discovery with far-reaching implications because of the widespread usage of AC materials in numerous analytical and environmental applications. The study results show that the properties of AC materials and reaction conditions play a crucial role in the catalyzed nitrosamine formation and should be carefully selected to minimize analytical errors and undesirable nitrosamine formation in water samples. Overall, the mechanistic information obtained in this research will be useful for the water industry and research communities to develop more effective strategies to control undesirable nitrosamine formation in water and wastewater treatment systems and thus better protect the public health.
322

Endotoxins detection and control in drinking water systems

Parent Uribe, Santiago. January 2007 (has links)
Endotoxins are a constituent of the lipopolysaccharide (LPS) complexes present in the outer layer of the cell wall of most Gram-negative bacteria and some cyanobacteria. The ingestion by a typical adult of amounts exceeding 1,000 endotoxin units (EUs) can cause fever, diarrhoea, vomiting, acute respiratory illnesses, and lung inflammation. In contrast, much smaller doses may lead to protective immunity against allergic diseases. / Endotoxins can be released in the air as well as in the water; previous studies have mainly focused on airborne endotoxins. Although many studies on endotoxins in raw and treated drinking waters have been performed, few have assessed seasonal variations and none have been conducted in Eastern Canada. Furthermore, a clear understanding of removal of endotoxins by various water treatment processes is still required. / Two methods to measure the concentrations of endotoxin were used and compared, the Limulus Amebocyte Lysate test (LAL) and the recombinant Factor C test (rFC). Raw water samples were taken from various drinking water sources around the Island of Montreal. The effects of free chlorine, UV radiation, and ozone were studied in batch experiments on filtered water samples via typical dosages and fluences used in drinking water treatment facilities. Residual concentrations for free chlorine were 0.8 and 1.6 mg/L; ozone doses were 0.5 and 1 mg/L; UV fluences were 40 and 100 mWs/cm2. Detention times of 20 and 60 minutes were tested for chlorine and 5 and 20 minutes for ozone. Grab sampling from three drinking water treatment plants in the Montreal area was performed during the months of June and late August/September 2006 and January 2007. Processes at these plants include coagulation and flocculation, sand filtration, ozonation and disinfection by chlorine. To test the variation in endotoxin concentrations during a sand filter cycle, samples were withdrawn directly from a filter in one of the treatment plants studied. The filtration cycle, from one backwash to the next one, lasts 72 h. Samples were collected immediately before the backwash, at the beginning and at the end of the ripening period, at the beginning of the filtration cycle and 48 h later, which corresponds to a half cycle period. / Of the two endotoxin detection methods used, LAL consistently gave slightly higher values compared to rFC; rFC also required more expensive hardware, but the method was less tedious and reagent costs were lower. Results presented, unless otherwise stated, were obtained with the rFC method. Endotoxin levels decreased in raw water samples between June and September. Concentrations ranged from 20 to 30 EU/mL in June, and decreased to 10 to 14 EU/mL in August and beyond. For the disinfection processes, the UV and free chlorine doses tested had little or no effect on the endotoxin concentrations, but ozone reduced the concentrations by up to 75%. Sand filtration and flocculation showed significant endotoxin removal efficiencies (50--60%). Levels remained around 5 EU/mL throughout the remaining treatment processes regardless of the influent concentration. Hence, endotoxin inactivation by free chlorine and UV does not occur with typical doses used in drinking water treatment plants; in contrast, flocculation and sand filtration, as well as ozonation, are much more effective.
323

Using quantitative microbial risk assessment to determine if health risk warrants boil water advisories in Newfoundland and Labrador : time for a new approach

Dawe, Paula V. 28 October 2013 (has links)
The effectiveness of Boil Water Advisories (BWAs) as a public health risk management tool is increasingly being questioned. Newfoundland and Labrador's zero-risk policy for issuing BWAs on public drinking water systems has resulted in over 210 active BWAs annually, the majority classified as long-term BWAs. BWAs are more likely to occur on small systems, in communities with low economic capacity, and in communities without a certified operator. No relationship was found relating confirmed cases of water-related illness to BWAs. Quantifiable health risk associated with BWAs was evaluated using Quantitative Microbial Risk Assessment (QMRA). Data on source water pathogen concentrations and epidemiological data was used to evaluate and calibrate the QMRA Model. The study demonstrated the application of QMRA in determining whether health risk warranted issuing a BWA. Eleven recommendations were made on how the province could adopt QMRA in establishing an alternative drinking water risk management and advisory framework.
324

Ultraviolet disinfection kinetics for potable water production.

Amos, Steve A. January 2008 (has links)
Irradiation with ultraviolet (UV) light is used for the disinfection of bacterial contaminants in the production of potable water, and in the treatment of selected wastewaters. However, efficacy of UV disinfection is limited by the combined effect of suspended solids concentration and UV absorbance. Limited published UV disinfection data are available that account for the combined effects of UV dose, suspended solids concentration and UV absorbance. This present lack of a rigorous quantitative understanding of the kinetics of UV disinfection limits process optimisation and wider application of UV treatment. The development and validation of an adequate model to describe UV disinfection kinetics presented in this thesis can therefore be justified by an increased confidence of reliability of design for UV disinfection. Using the published data of Nguyen (1999), four established model forms were assessed to account for the combined effect of suspended solids and/or soluble UV absorbing compounds, and UV dose on the efficacy of disinfection. The four model forms were: a log-linear form, Davey Linear-Arrhenius (DL-A), Square-Root (or Ratkowsky- Belehradek) and a general nth order Polynomial (nOP) form that was limited to a third order. Criteria for assessment of an adequate predictive model were established including: accuracy of predicted against observed values, percent variance accounted for (%V), and; appraisal of residuals. The DL-A model was shown to best fit the data for UV disinfection of Escherichia coli (ATCC 25922); followed by the nOP, log-linear and Square-Root forms. However, the DL-A form must be used in conjunction with a first-order chemical reaction equation, and was shown to predict poorly at high experimental values of UV dose (> 40,000 μWs cm-2). The DL-A model was not amenable to extrapolation beyond the observed UV dose range. To overcome the shortcomings of the Davey Linear-Arrhenius model synthesis of two new, non-linear model forms was undertaken. The two models were a modified exponentially damped polynomial (EDPm) and a form based on the Weibull probability distribution. The EDPm model has three terms: a rate coefficient (k), a damping coefficient (λ), and; a breakpoint dose ([dose]B). The rate coefficient governs the initial rate of disinfection prior to the onset of tailing, whilst the breakpoint is the UV dose that indicates the onset of tailing. The damping coefficient controls curvature in the survivor curve. The Weibull model has just two terms: a dimensionless scale parameter (β0), and; a shape parameter (β1). The scale parameter represents the level of disinfection in the tail of the survivor curve (as log10 N/N0), whilst the shape parameter governs the degree of curvature of the survivor data. Each model was assessed against the independent and published UV disinfection data of Nelson (2000) for treatment of faecal coliforms in a range of waste stabilisation pond effluents. Both models were found to be well suited to account for tailing in these UV disinfection data. Overall, the EDPm model gave a better fit to the data than the Weibull model form. To rigorously validate the suitability of the new EDPm and Weibull models a series of experimental trials were designed and carried out in a small-scale pilot UV disinfection unit. These trials included data determined specifically at low values of UV dose (<10,000 μWs cm-2) to fill the gap in the experimental data of Nguyen (1999). The experimental trials were carried out using a commercially available, UV disinfection unit (LC5TM from Ultraviolet Technology of Australasia Pty Ltd). Purified water contaminated with Escherichia coli (ATCC 25922) with a range of feed water flow rates (1 to 4 L min-1) was used. E. coli was selected because it is found in sewage, or water contaminated with faecal material, and is used as an indicator for the presence of enteric pathogens. E. coli should not be present in potable water. The hydrodynamics of water flow within the disinfection unit were established using digital video photography of dye trace studies with Methylene Blue. Nominal UV dose (2,700 to 44,200 μWs cm-2) was controlled by manipulating the flow rate of feed water through the UV disinfection unit (i.e. residence time), or by varying the exposed length of the control volume of the disinfection unit. The transmittance of the feed water (at 254 nm) was adjusted by the addition of either a soluble UV absorbing agent (International RoastTM instant coffee powder; 0.001 to 0.07 g L-1), or by addition of suspended matter as diatomaceous earth (Celite 503TM; 0.1 to 0.7 g L-1, with a median particle size of 23 μm). The absorbing agent (instant coffee), when in a comparable concentration, was found to produce a greater reduction in water transmission than the suspended material (Celite 503TM). It therefore contributed to a greater reduction in the initial rate of disinfection. Neither agent was found to produce a systematic reduction in the observed efficacy of disinfection however. Experimental results highlight that in the absence of soluble absorbing agents, or suspended solids, the initial rate of disinfection is higher when fewer viable bacteria are initially present. Both the new EDPm and Weibull forms gave a good fit to the experimental data. The EDPm better fitted the data on the basis of residual sum-of-squares (0.03 to 2.13 for EDPm cf. 0.16 to 4.37 for the Weibull form). These models are both of a form suitable for practical use in modelling UV disinfection data. Results of this research highlight the impact of water quality, as influenced by the combined effect of UV dose, suspended solids concentration and UV absorbance, on small-scale UV disinfection for potable water production. Importantly, results show that the concentration of soluble UV absorbing agents and suspended solids are not in themselves sufficient criteria on which to base assessment of efficacy of UV disinfection / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1342403 / Thesis (M.Eng.Sc.) - University of Adelaide, School of Chemical Engineering, 2008
325

Ultraviolet disinfection kinetics for potable water production.

Amos, Steve A. January 2008 (has links)
Irradiation with ultraviolet (UV) light is used for the disinfection of bacterial contaminants in the production of potable water, and in the treatment of selected wastewaters. However, efficacy of UV disinfection is limited by the combined effect of suspended solids concentration and UV absorbance. Limited published UV disinfection data are available that account for the combined effects of UV dose, suspended solids concentration and UV absorbance. This present lack of a rigorous quantitative understanding of the kinetics of UV disinfection limits process optimisation and wider application of UV treatment. The development and validation of an adequate model to describe UV disinfection kinetics presented in this thesis can therefore be justified by an increased confidence of reliability of design for UV disinfection. Using the published data of Nguyen (1999), four established model forms were assessed to account for the combined effect of suspended solids and/or soluble UV absorbing compounds, and UV dose on the efficacy of disinfection. The four model forms were: a log-linear form, Davey Linear-Arrhenius (DL-A), Square-Root (or Ratkowsky- Belehradek) and a general nth order Polynomial (nOP) form that was limited to a third order. Criteria for assessment of an adequate predictive model were established including: accuracy of predicted against observed values, percent variance accounted for (%V), and; appraisal of residuals. The DL-A model was shown to best fit the data for UV disinfection of Escherichia coli (ATCC 25922); followed by the nOP, log-linear and Square-Root forms. However, the DL-A form must be used in conjunction with a first-order chemical reaction equation, and was shown to predict poorly at high experimental values of UV dose (> 40,000 μWs cm-2). The DL-A model was not amenable to extrapolation beyond the observed UV dose range. To overcome the shortcomings of the Davey Linear-Arrhenius model synthesis of two new, non-linear model forms was undertaken. The two models were a modified exponentially damped polynomial (EDPm) and a form based on the Weibull probability distribution. The EDPm model has three terms: a rate coefficient (k), a damping coefficient (λ), and; a breakpoint dose ([dose]B). The rate coefficient governs the initial rate of disinfection prior to the onset of tailing, whilst the breakpoint is the UV dose that indicates the onset of tailing. The damping coefficient controls curvature in the survivor curve. The Weibull model has just two terms: a dimensionless scale parameter (β0), and; a shape parameter (β1). The scale parameter represents the level of disinfection in the tail of the survivor curve (as log10 N/N0), whilst the shape parameter governs the degree of curvature of the survivor data. Each model was assessed against the independent and published UV disinfection data of Nelson (2000) for treatment of faecal coliforms in a range of waste stabilisation pond effluents. Both models were found to be well suited to account for tailing in these UV disinfection data. Overall, the EDPm model gave a better fit to the data than the Weibull model form. To rigorously validate the suitability of the new EDPm and Weibull models a series of experimental trials were designed and carried out in a small-scale pilot UV disinfection unit. These trials included data determined specifically at low values of UV dose (<10,000 μWs cm-2) to fill the gap in the experimental data of Nguyen (1999). The experimental trials were carried out using a commercially available, UV disinfection unit (LC5TM from Ultraviolet Technology of Australasia Pty Ltd). Purified water contaminated with Escherichia coli (ATCC 25922) with a range of feed water flow rates (1 to 4 L min-1) was used. E. coli was selected because it is found in sewage, or water contaminated with faecal material, and is used as an indicator for the presence of enteric pathogens. E. coli should not be present in potable water. The hydrodynamics of water flow within the disinfection unit were established using digital video photography of dye trace studies with Methylene Blue. Nominal UV dose (2,700 to 44,200 μWs cm-2) was controlled by manipulating the flow rate of feed water through the UV disinfection unit (i.e. residence time), or by varying the exposed length of the control volume of the disinfection unit. The transmittance of the feed water (at 254 nm) was adjusted by the addition of either a soluble UV absorbing agent (International RoastTM instant coffee powder; 0.001 to 0.07 g L-1), or by addition of suspended matter as diatomaceous earth (Celite 503TM; 0.1 to 0.7 g L-1, with a median particle size of 23 μm). The absorbing agent (instant coffee), when in a comparable concentration, was found to produce a greater reduction in water transmission than the suspended material (Celite 503TM). It therefore contributed to a greater reduction in the initial rate of disinfection. Neither agent was found to produce a systematic reduction in the observed efficacy of disinfection however. Experimental results highlight that in the absence of soluble absorbing agents, or suspended solids, the initial rate of disinfection is higher when fewer viable bacteria are initially present. Both the new EDPm and Weibull forms gave a good fit to the experimental data. The EDPm better fitted the data on the basis of residual sum-of-squares (0.03 to 2.13 for EDPm cf. 0.16 to 4.37 for the Weibull form). These models are both of a form suitable for practical use in modelling UV disinfection data. Results of this research highlight the impact of water quality, as influenced by the combined effect of UV dose, suspended solids concentration and UV absorbance, on small-scale UV disinfection for potable water production. Importantly, results show that the concentration of soluble UV absorbing agents and suspended solids are not in themselves sufficient criteria on which to base assessment of efficacy of UV disinfection / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1342403 / Thesis (M.Eng.Sc.) - University of Adelaide, School of Chemical Engineering, 2008
326

Ultraviolet disinfection kinetics for potable water production.

Amos, Steve A. January 2008 (has links)
Irradiation with ultraviolet (UV) light is used for the disinfection of bacterial contaminants in the production of potable water, and in the treatment of selected wastewaters. However, efficacy of UV disinfection is limited by the combined effect of suspended solids concentration and UV absorbance. Limited published UV disinfection data are available that account for the combined effects of UV dose, suspended solids concentration and UV absorbance. This present lack of a rigorous quantitative understanding of the kinetics of UV disinfection limits process optimisation and wider application of UV treatment. The development and validation of an adequate model to describe UV disinfection kinetics presented in this thesis can therefore be justified by an increased confidence of reliability of design for UV disinfection. Using the published data of Nguyen (1999), four established model forms were assessed to account for the combined effect of suspended solids and/or soluble UV absorbing compounds, and UV dose on the efficacy of disinfection. The four model forms were: a log-linear form, Davey Linear-Arrhenius (DL-A), Square-Root (or Ratkowsky- Belehradek) and a general nth order Polynomial (nOP) form that was limited to a third order. Criteria for assessment of an adequate predictive model were established including: accuracy of predicted against observed values, percent variance accounted for (%V), and; appraisal of residuals. The DL-A model was shown to best fit the data for UV disinfection of Escherichia coli (ATCC 25922); followed by the nOP, log-linear and Square-Root forms. However, the DL-A form must be used in conjunction with a first-order chemical reaction equation, and was shown to predict poorly at high experimental values of UV dose (> 40,000 μWs cm-2). The DL-A model was not amenable to extrapolation beyond the observed UV dose range. To overcome the shortcomings of the Davey Linear-Arrhenius model synthesis of two new, non-linear model forms was undertaken. The two models were a modified exponentially damped polynomial (EDPm) and a form based on the Weibull probability distribution. The EDPm model has three terms: a rate coefficient (k), a damping coefficient (λ), and; a breakpoint dose ([dose]B). The rate coefficient governs the initial rate of disinfection prior to the onset of tailing, whilst the breakpoint is the UV dose that indicates the onset of tailing. The damping coefficient controls curvature in the survivor curve. The Weibull model has just two terms: a dimensionless scale parameter (β0), and; a shape parameter (β1). The scale parameter represents the level of disinfection in the tail of the survivor curve (as log10 N/N0), whilst the shape parameter governs the degree of curvature of the survivor data. Each model was assessed against the independent and published UV disinfection data of Nelson (2000) for treatment of faecal coliforms in a range of waste stabilisation pond effluents. Both models were found to be well suited to account for tailing in these UV disinfection data. Overall, the EDPm model gave a better fit to the data than the Weibull model form. To rigorously validate the suitability of the new EDPm and Weibull models a series of experimental trials were designed and carried out in a small-scale pilot UV disinfection unit. These trials included data determined specifically at low values of UV dose (<10,000 μWs cm-2) to fill the gap in the experimental data of Nguyen (1999). The experimental trials were carried out using a commercially available, UV disinfection unit (LC5TM from Ultraviolet Technology of Australasia Pty Ltd). Purified water contaminated with Escherichia coli (ATCC 25922) with a range of feed water flow rates (1 to 4 L min-1) was used. E. coli was selected because it is found in sewage, or water contaminated with faecal material, and is used as an indicator for the presence of enteric pathogens. E. coli should not be present in potable water. The hydrodynamics of water flow within the disinfection unit were established using digital video photography of dye trace studies with Methylene Blue. Nominal UV dose (2,700 to 44,200 μWs cm-2) was controlled by manipulating the flow rate of feed water through the UV disinfection unit (i.e. residence time), or by varying the exposed length of the control volume of the disinfection unit. The transmittance of the feed water (at 254 nm) was adjusted by the addition of either a soluble UV absorbing agent (International RoastTM instant coffee powder; 0.001 to 0.07 g L-1), or by addition of suspended matter as diatomaceous earth (Celite 503TM; 0.1 to 0.7 g L-1, with a median particle size of 23 μm). The absorbing agent (instant coffee), when in a comparable concentration, was found to produce a greater reduction in water transmission than the suspended material (Celite 503TM). It therefore contributed to a greater reduction in the initial rate of disinfection. Neither agent was found to produce a systematic reduction in the observed efficacy of disinfection however. Experimental results highlight that in the absence of soluble absorbing agents, or suspended solids, the initial rate of disinfection is higher when fewer viable bacteria are initially present. Both the new EDPm and Weibull forms gave a good fit to the experimental data. The EDPm better fitted the data on the basis of residual sum-of-squares (0.03 to 2.13 for EDPm cf. 0.16 to 4.37 for the Weibull form). These models are both of a form suitable for practical use in modelling UV disinfection data. Results of this research highlight the impact of water quality, as influenced by the combined effect of UV dose, suspended solids concentration and UV absorbance, on small-scale UV disinfection for potable water production. Importantly, results show that the concentration of soluble UV absorbing agents and suspended solids are not in themselves sufficient criteria on which to base assessment of efficacy of UV disinfection / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1342403 / Thesis (M.Eng.Sc.) - University of Adelaide, School of Chemical Engineering, 2008
327

Perfluorinated compounds and trihalomethanes in drinking water sources of the Western Cape, South Africa

Booi, Xolelwa January 2013 (has links)
Thesis submitted in partial fulfilment of the requirements for the degree of MAGISTER TECHNOLOGIAE: CHEMICAL ENGINEERING in the FACULTY OF ENGINEERING at the CAPE PENINSULA UNIVERSITY OF TECHNOLOGY 2013 / This study focused on quantifying two types of internationally regulated contaminants found in drinking water: 1) Trihalomethanes (THMs) and 2) Perfluorinated compounds (PFCs). The first contaminants monitored were THMs, classified as a group of chemicals that are formed along with others during the disinfection of water using liquid chlorine, chlorine dioxide or chlorine gas. Hence, the resulting compounds are called disinfection by-products (DBPs). The disinfectant reacts with natural organic matter in water to form common THMs, which include chloroform (CHCl3 or CF), bromodichloromethane (CHCl2Br or BDCM), dibromochloromethane (CHClBr2 or DBCM) and bromoform (CHBr3 or BF), with chloroform being the most common in chlorinated water systems. The current study has focused on THMs for two primary reasons: 1) THMs have raised significant concern as a result of evidence that associate their presence in drinking water with potential adverse human health effects, including cancer and 2) the levels of THMs in drinking water post-treatment is not monitored regularly in South Africa and thus far, there is inadequate and limited information about their concentration levels for drinking water treatment plants (DWTPs) and distribution stations (DWDSs) of the Western Cape, South Africa before, distribution to various suburbs, including townships. THMs normally occur at higher levels than any other known DBPs and their presence in treated water is a representative of the occurrence of many other DBPs. THMs were quantified in chlorinated drinking water obtained from seven (7) DWTPs, namely; Atlantis, Blackheath, Faure, Brooklands, Steenbras, Voelvlei and Wemmershoek, and one DWDS in Plattekloof. This included determining THMs concentration in tap water collected from various suburbs including townships, to assist local authorities in obtaining information on their concentration and whether or not the presence of residual chlorine and organic matter on post-treatment results has increased THMs at the point of use. THM analysis was performed using liquid-liquid extraction/gas chromatography with electron capture detector (LLE-GC-ECD) analytical process according to the EPA method 501.2, which was used with minor modifications. The instrument operational conditions were as follows: Column → DB5-26, 30 mm, 0.53 mm, 1.0 μm df HP-1 (Agilent Technologies, USA); Carrier gas → Helium at a constant inlet pressure of 15 kPa; Make-up gas → 99.9% Nitrogen gas at 60 L/min; Injector temperature → 40°C; Oven temperature → 270°C and Detector temperature → 300°C. Since natural organic matter (NOM) in raw water is a precursor for THM formation, NOM analysis was performed as total organic carbon (TOC) using Spectroquant TOC test kits. Other drinking water quality parameters analysed were pH, residual free chlorine, conductivity and total dissolved solids (TDS). The average Total THM concentrations detected from seven of the DWTPs, including the DWDS, ranged from 26.52 μg/L (for Plattekloof) to 32.82 μg/L (for Brooklands), with the observed concentrations being comparable. The average chloroform concentrations were the highest in all the water samples, ranging from 11.74 μg/L (for Plattekloof) to 22.29 μg/L (for Voelvlei), while DBCM had the lowest concentration. The only DWTP that was not comparable with the seven DWTPs was Atlantis, with the highest average TTHM concentration of 83.48 μg/L and a chloroform concentration of 46.06 μg/L. From the tap water samples collected from 14 Western Cape suburbs, the average TTHM concentrations ranged from 5.30 ug/L (for Mandalay) to 13.12 μg/L (for Browns Farm, Philippi), and all these concentrations were lower than the TTHM concentrations detected in the water samples from the DWTP. Overall, the average total THM and individual THM species concentrations were below the recommended SANS 241:2011 and WHO drinking water guideline limits. This included the observed pH (6.39 to 7.73), residual free chlorine (0.22 to 1.06 mg/L), conductivity (121 to 444 μS/cm), TDS (93.93 to 344.35 mg/L) and TOC (0.38 to 1.20 mg/L). All these water quality parameters were within the specification limits stipulated in SANS 241. However, the average residual free chlorine concentration for Atlantis was very low (0.06 mg/L), which was below the WHO minimum residual free chlorine concentration guideline value of 0.2 mg/L for a distribution network – an indication that suggested the need for a re-chlorination station prior to distribution to households. Low chlorine content might result in the formation of unwanted biofilms in the distribution network, thus reducing the organoleptic properties of the water. Additionally, there was no direct link between several water quality parameters quantified (i.e. pH, TOC and water temperature) to TTHM formation. However, a high chlorine dose was observed to result directly in a higher concentration of chloroform in treated water prior to distribution. The second contaminants monitored were Perfluorinated compounds (PFCs), which are non-biodegradable, persistent and toxic organic chemicals known for their ability to contaminate environmental matrices, including drinking water sources. In recent years, many researchers considered it essential to identify and quantify PFC levels in drinking water worldwide with the main focus being on the two most abundant PFCs; namely Perfluorooctanoic acid (PFOA) and Perfluorooctane sulfonate (PFOS). Their toxic effects to human health, plants and wildlife were also evaluated, classifying them as possible carcinogens. We know from the literature reviewed that, although the presence of PFCs in drinking water has been documented worldwide, there is limited information about their presence specifically in South African drinking water sources, even about less studied PFCs such as Perfluoroheptanoic acid (PFHpA), Perfluorododecanoic acid (PFDoA), Perfluorononanoic acid (PFNA), Perfluoroundecanoic acid (PFUA), Perfluorodecanoic acid (PFDeA) and the well-known PFOA including PFOS. Although several other PFCs have been detected in water sources and reported in various studies, the USEPA only issued drinking water guideline limits for Perfluorooctanoic acid (PFOA) and Perfluorooctane sulfonate (PFOS) of 400 ng/L and 200 ng/L, respectively, with no mention of the other PFCs. However, these PFCs have similar properties to those of PFOA and PFOS as they have been shown to impose similar detrimental health effects on human health. This study thus focused on the detection of PFCs in both raw and treated drinking water in the Western Cape DWTPs such as Atlantis, Blackheath, Faure, Brooklands, Steenbras, Voelvlei and Wemmershoek, and one DWDS in Plattekloof. Water samples (raw and treated water) used in this study for PFC analysis were collected in 2L polypropylene screw capped bottles. PFC analysis was performed in four sample batches for each location collected through the period of October to December 2012 (summer). PFCs were analysed in accordance with a modified EPA method 537, which entails solid phase extraction (SPE) followed by analysis using a liquid chromatography/tandem mass spectrometer (LC/MS/MS). The slight modification was with the water sample volume used for extraction, which was increased from 250 mL to 500 mL. The instrument used was an HPLC - Ultimate 3000 Dionex HPLC system and MS model - Amazon SL Ion Trap, with the following MS/MS operational conditions and Ion mode: MS Interface → ESI; Dry temp → 350C; Nebulizing pressure → 60 psi; Dry gas flow → 10 L/min; Ionisation mode → negative; capillary voltage → +4500V; End plate offset → −500V while the separation column was a Waters Sunfire C18, 5 μm, 4.6 × 150 mm column (Supplier: Waters, Dublin, Ireland) with an operational temperature of 30C. From the results obtained in this study, seven different PFCs (i.e. PFHpA, PFDoA, PFNA, PFUA, PFDeA, PFOA and PFOS), were detected in raw and treated water with PFOA and PFOS being the least detected PFCs as they were detected only in raw water (PFOA) from Faure, as well as raw and treated water (PFOS) from Brooklands. The highest concentration observed in treated water was for PFHpA, which was quantified at a maximum average concentration of 43.80 ng/L (Plattekloof). The maximum average concentrations of other PFCs detected were as follows: PFDoA - 4.415 ng/L for Faure raw water; PFNA - 2.922 ng/L for Plattekloof outlet; PFUA - 7.965 ng/L for Brooklands treated water and PFDeA - 2.744 ng/L for Faure raw water. Another observation from the results was that the concentration of the majority of the PFCs detected in treated water was higher than that quantified in raw water, suggesting possible contamination by materials used during water treatment. In conclusion, THMs detected in treated water from various DWTPs and one DWDS in the Western Cape met the required local and international drinking water quality guidelines, while the presence of PFOS, PFOA, PFHpA, PFDoA, PFNA, PFUA and PFDeA in treated water requires that local water professionals continue to monitor their presence to ensure that measures for their reduction are in place. Furthermore, the National standards (SANS 241) for municipal drinking water guidelines must be updated to include the monitoring of PFCs, including the lesser known and less studied PFCs such as PFHpA, PFDoA, PFNA, PFUA and PFDeA.
328

Household Water Filter Use Characterization in Rural Rwanda: Signal Interpretation, Development and Validation

Tellez Sanchez, Sarita Lucia 19 July 2016 (has links)
Access to safe drinking water is an important health factor in many developing countries. Studies have shown that unsafe drinking water and poor sanitation practices leads to diarrheal disease, which is one of the leading causes of death of children under five in developing countries. Provision and proper use of household water filters have been shown to effectively improve health. This thesis is focused on the refinement and validation of algorithms for data collected from pressure transducer sensors that are used in household water filters (the Vestergaard Frandsen LifeStraw Family 2.0) deployed in Rwanda by the social enterprise DelAgua Health. Statistical and signal processing techniques were used to detect the use of the LifeStraw water filters and to estimate the amount of water filtered at the time of usage. An algorithm developed by Dr. Carson Wick at Georgia Institute of Technology was the baseline for the analysis of the data. The algorithm was then refined based on data collected in the SweetLab at Portland State University, which was then applied to field data. Laboratory results indicated that the mean error of the improved algorithm is 11.5% as compared with the baseline algorithm mean error of 39%. The validation of the algorithm with field data yielded a mean error of 5%. Errors may be attributed to real-world behavior of the water filter, electronic noise, ambient temperature, and variations in the approximation made to the field data. This work also presents some consideration of the algorithm applied to soft-sided water backpacks.
329

Možnosti odstraňování kovů ze zdrojů pitné vody vodárenskými procesy / Possibilities of removing metals from drinking water sources by water treatment processes

Marzinová, Kristýna January 2022 (has links)
In my diploma thesis I focused on the issue of metals, their occurrence in drinking water sources in the Czech Republic and the possibility of their removal by water supply processes. Heavy metals degrade the quality of water resources, so more complex water treatment technologies are needed. The first part describes the metals, their properties, their significance and occurrence in water, then the possibility of removing metals using water supply processes. In the practical part of the diploma thesis I performed a laboratory experiment to remove iron, manganese and nickel by adsorption on selected filter materials, which are Filtrasorb F100, Filtrasorb F 400, Bayoxide E33 and GEH. The experiment was used to compare the effectiveness of selected sorption materials.
330

Determining the effectiveness of water treatment process barriers for the removal of viruses in drinking water.

Setlhare, Khomotso Charity January 2018 (has links)
M. Tech (Department of Biotechnology, Faculty of Applied and Computer Sciences) Vaal University of Technology. / The presence of enteric viruses in drinking water poses a health risk to consumers. It is therefore very important for drinking water suppliers to provide water that is pathogen free and fit for human consumption. This can be achieved by an effective water treatment system that ensures the safety of water from the treatment plant until the water reaches the consumer. This study assessed the ability of a conventional water treatment system to remove viruses. The system consisted of three unit processes, namely, clarification, sand filtration and disinfection. These processes were simulated on a bench-scale to determine the effectiveness of each one at removing viruses. Clarification was conducted using a Phipps and Bird jar testing system and three different chemical treatments: (i) Polyelectrolyte (SUDFLOC 3835), (ii) a combination of lime and activated silica and (iii) a combination of lime, activated silica and ferric chloride. Sand filtration was simulated using a Phipps and Bird column filtration system. Disinfection was conducted using free chlorine. The findings from this study showed that the removal or inactivation of viruses increased with an increase in the concentration of chemicals added. For clarification, the combination of lime, activated silica and ferric chloride was the most effective treatment for the removal or inactivation of viruses. Sand filtration was found to be ineffective for the removal of viruses. Disinfection was shown to be the most effective process for the removal or inactivation of viruses. While clarification, sand filtration and disinfection did not remove or inactivate viruses equally, the entire treatment chain is still essential. This is because even if a barrier does not directly remove viruses it ensures that subsequent processes can function effectively. Overall the treatment processes should not be considered as discrete barriers but rather an integrated system that must function throughout to avoid a risk to customers.

Page generated in 0.1077 seconds