• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Optimisation de la source synchrotron cohérente dans le domaine des Térahertz pour la spectroscopie à haute résolution de molécules d'intérêt astrophysique / Optimization of a coherent synchrotron radiation source in the Terahertz range for high-resolution spectroscopy of molecules of astrophysical interest

Barros, Joanna 18 December 2012 (has links)
La spectroscopie par transformée de Fourier est l’outil multiplexe de mesure de spectres à haute résolution le plus utilisé dans l’infrarouge. Son extension au domaine Térahertz se révèle de grand intérêt pour la spectroscopie de molécules présentes dans le milieu interstellaire, mais se heurte à différents obstacles : en particulier, aucune source large bande n'est suffisamment intense et stable pour ces applications. Cette thèse présente des développements instrumentaux basés sur l’exploitation du rayonnement synchrotron cohérent (CSR) sur la ligne AILES du synchrotron SOLEIL, optimisée pour l'infrarouge lointain. Les conditions de production du CSR sont étudiées pour les besoins des analyses spectroscopiques à haute résolution ; les performances de cette source sont caractérisées et comparées à celles du rayonnement incohérent. La mise en place d'un système de double détection permet une correction de l'effet des instabilités de la source et une augmentation conséquente du rapport signal-sur-bruit. Ces développements sont appliqués à la mesure de spectres de rotation pure ; une modélisation améliorée du spectre dans l'état fondamental de la molécule de propynal a ainsi pu être faite, prouvant la complémentarité de la source étudiée vis-à-vis des sources micro-onde ou infrarouge classiques. / Fourier Transform spectroscopy is the most used multiplex tool for high-resolution measurements in the infrared range. Its extension to the Terahertz domain is of great interest for spectroscopic studies of interstellar molecules. This application is however hampered by the lack of dedicated, broadband sources with a sufficient intensity and stability. In this work, Coherent Synchrotron Radiation (CSR) was used as a source for molecular spectroscopy at high resolution on the AILES infrared and Terahertz beamline of SOLEIL synchrotron. The beamline being optimized for far-infrared, we could characterize the properties of CSR and compare them to the incoherent synchrotron radiation. A double detection system allowed to correct the effect of the source-related instabilities, hence to significantly increase the signal-to-noise ratio. Pure rotational spectra were measured using these developments. The case of the propynal molecule, for which a refined set of rotational and centrifugal distortion constants was calculated, proves the complementarity between CSR and the classical microwave or infrared sources.
2

Stanovení vybraných komponent v lidské moči elektroforézou v krátké kapiláře. / Determination of selected components in human urine with electrophoresis in short capillary.

Makrlíková, Anna January 2015 (has links)
Capillary zone electrophoresis is frequently used in various analyses. In this diploma thesis a hydrodynamic sample introduction method controlled by pressure pulse has been proposed for short-capillary electrophoresis. The base electrolyte flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. At the time when the sample zone reached the capillary, a short pressure impulse is generated in the electrolyte stream, which provides injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. This new sample introduction method was tested in the determination of ammonia, histidine, creatinine, uric acid and hippuric acid in human urine and for rapid screening of the contents of the inorganic ions in cerebrospinal fluid and blood plasma. The determination was performed in a capillary with an overall length of 10,5 cm and two base electrolytes was tested - 50 mM MES + 5 mM NaOH (pH 5,10) and 1 M acetic acid + 1,5 mM crown ether 18-crown-6 (pH 2,40). Using dual detection techniques contactless conductivity and UV spectrometric detection, anorganic and organic substances in the sample could...

Page generated in 0.0649 seconds