• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 40
  • 40
  • 19
  • 17
  • 15
  • 15
  • 12
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Double-Beta Decay of 96Zr and Double-Electron Capture of 156Dy to Excited Final States

Finch, Sean January 2015 (has links)
<p>Two separate experimental searches for second-order weak nuclear decays to excited final states were conducted. Both experiments were carried out at the Kimballton Underground Research Facility to provide shielding from cosmic rays. The first search is for the two-neutrino double-beta decay of 96Zr to excited final states of the daughter nucleus, 96Mo. As a by product of this experiment, the beta decay of 96Zr was also investigated. Two coaxial high-purity germanium detectors were used in coincidence to detect gamma rays produced by the daughter nucleus as it de-excited to the ground state. After collecting 1.92 years of data with 17.91 g of enriched 96Zr, half-life limits at the level of 10^20 yr were produced. Measurements of this decay are important to test neutrinoless double-beta decay nuclear matrix element calculations, which are necessary to extract the neutrino mass from a measurement of the neutrinoless double-beta decay half-life. </p><p>The second experiment is a search for the resonantly-enhanced neutrinoless double-electron capture decay of 156Dy to excited states in 156Gd. Double-electron capture is a possible experimental alternative to neutrinoless-double beta decay, which could distinguish the Dirac or Majorana nature of the neutrino. Two clover high-purity germanium detectors were used in coincidence to investigate the decay. A 213.5 mg enriched 156Dy sample was observed for 0.635 year, producing half-life limits of 10^17 yr. The limits produced by both of these experiments are currently the most stringent limits available for these decays.</p> / Dissertation
12

An experimental study of state selective electron capture by state prepared low energy (<25 keV amu'-'1) ions in atomic and molecular hydrogen

Voulot, Didier January 2000 (has links)
No description available.
13

Determinacao de residuos de hexaclorociclohexano 'HCH' no soro sanguineo de trabalhadores expostos no arquivo historico de Joinville na decada de 80

LOIOLA, ELAINE C.D. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:58Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
14

Determinacao de residuos de hexaclorociclohexano 'HCH' no soro sanguineo de trabalhadores expostos no arquivo historico de Joinville na decada de 80

LOIOLA, ELAINE C.D. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:58Z (GMT). No. of bitstreams: 0 / O Hexaclorociclohexano (HCH) é um inseticida do grupo dos organoclorados, composto por uma mistura de isômeros formados durante a síntese química, através de sucessivas adições de cloro ao benzeno. Estes isômeros podem contaminar não só o meio ambiente como também a população que tenha contato direto ou indireto com os resíduos. Nas décadas de 70 e 80, foi utilizado um produto comercial composto pelo ativo HCH comercializado como \"Hexabel®\" no controle de insetos xilófagos no Acervo Histórico de Joinville em Santa Catarina. A aplicação do inseticida foi realizada pelos próprios funcionários do Arquivo Histórico, e houve intensa manipulação dos documentos tratados durante uma mudança do prédio o presente trabalho teve como objetivo validar uma metodologia de determinação de resíduos do HCH e seus isômeros em soro sangüíneo, e analisar o grau de exposição dos funcionários e ex-funcionários do Arquivo Histórico de Joinville ao produto. Foram realizados exames sorológicos em todos os funcionários e ex - funcionários do local e também na população que sabidamente nunca tiveram contato com o ativo, denominada população controle. As análises foram realizadas após a validação do método multiresíduos que obtém todos os ativos em uma única extração e tem detecção por Cromatografia a gás com detector de captura (GC-ECD) de elétrons. Os resultados comprovaram comprovaram a eficiência do método, através de dados em conformidade com os critérios do ensaio. Os resultados obtidos no estudo da população mostraram que a quantidade de HCH no soro sangüíneo de funcionários, ex-funcionários e da população controle estão abaixo do limite de quantificação de 0,04&mu;g dL-1 para Alfa HCH e Gama HCH \"Lindana\" e 0,08&mu;g dL-1 para Beta e Delta HCH. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
15

Determinação de resíduos de hexaclorociclohexano \"HCH\" no soro sanguíneo de trabalhadores expostos no Arquivo Histórico de Joinville na década de 80 / Determination of hexachlorcyciohexane residues on blood plasma of exposed employees of the Historical Archieve of Joinville on 80\'s decade

Elaine Cristina Damasceno Loiola 13 December 2007 (has links)
O Hexaclorociclohexano (HCH) é um inseticida do grupo dos organoclorados, composto por uma mistura de isômeros formados durante a síntese química, através de sucessivas adições de cloro ao benzeno. Estes isômeros podem contaminar não só o meio ambiente como também a população que tenha contato direto ou indireto com os resíduos. Nas décadas de 70 e 80, foi utilizado um produto comercial composto pelo ativo HCH comercializado como \"Hexabel®\" no controle de insetos xilófagos no Acervo Histórico de Joinville em Santa Catarina. A aplicação do inseticida foi realizada pelos próprios funcionários do Arquivo Histórico, e houve intensa manipulação dos documentos tratados durante uma mudança do prédio o presente trabalho teve como objetivo validar uma metodologia de determinação de resíduos do HCH e seus isômeros em soro sangüíneo, e analisar o grau de exposição dos funcionários e ex-funcionários do Arquivo Histórico de Joinville ao produto. Foram realizados exames sorológicos em todos os funcionários e ex - funcionários do local e também na população que sabidamente nunca tiveram contato com o ativo, denominada população controle. As análises foram realizadas após a validação do método multiresíduos que obtém todos os ativos em uma única extração e tem detecção por Cromatografia a gás com detector de captura (GC-ECD) de elétrons. Os resultados comprovaram comprovaram a eficiência do método, através de dados em conformidade com os critérios do ensaio. Os resultados obtidos no estudo da população mostraram que a quantidade de HCH no soro sangüíneo de funcionários, ex-funcionários e da população controle estão abaixo do limite de quantificação de 0,04&mu;g dL-1 para Alfa HCH e Gama HCH \"Lindana\" e 0,08&mu;g dL-1 para Beta e Delta HCH. / Hexachlorcyciohexane (HCH) is an organochloride insecticide formed by a mixture of chemical isomers produced during its chemical synthesis, obtained after successive inserts of chlorine atoms on benzene molecule. These isomers may contaminate both the environment and the people who had direct or indirect contact with the HCH residues. On 70\'s and 80\'s, its was used a commercial product which contained HCH on its formula and was commercialized as Hexabel®. The product was used to control the xylophage insect population on the Historical Archieve of Joinville, at Santa Catarina, Brazil. The own employees did the insecticide application and there was an intensive manipulation of the treated material during a building change. The objective of this work was to validate a methodology to quantify the HCH residues and its isomers on blood plasma and analyze the employee\'s exposure extent to the chemical. It was done serological investigation on employees, former-employees and on non-exposed people, which was classified as the control population. The analyses were done after the methodology validation. The method was capable to obtain all isomers on a unique extraction and the detection and quantification were done by gas chromatography with electron-capture detector (GC-ECD). The results obtained showed that the proposed method is accurate, and that the amount of HCH residues on blood plasma of all individuals analyzed was lower than the quantification limits established to the method, which were 0,04 &mu;g dL-1 for the alpha- and gamma- HCH (lindana) and 0,08 &mu;g dL-1 for the beta- and delta- HCH.
16

Monitoring kontaminace vody a sedimentů / Monitoring of water and sediment contamination

Grajciariková, Eva January 2011 (has links)
The diploma thesis is focused on the issue of the presence of POPs in the surface water and sediments. Monitored compounds were chosen from the group of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDE). Samples were collected in selected localities in the Slovak and the Czech Republic. Selected analytes were extracted with hexane from the aqueous matrix. Analytes were isolated by the ultrasonic extraction using a solvent mixture of hexane-dichlormethane from the solid matrix and the resulting extract was cleaned up by the column chromatography filled with the florisil and the silica gel. Target compounds were analysed by GC/ECD finally. Obtained results show the level of contamination in selected localities in the Slovak and the Czech Republic.
17

Estudo dos poluentes orgânicos persistentes (POPS) em regiões industriais da Grande São Paulo - via cromatografia a gás acoplada a espectrometria de massas (GC-MS) e captura de elétrons (GC-ECD) / Study of persistent organic pollutants (POPs) in industrial areas of Greater São Paulo - via gas chromatography-mass spectrometry (GC-MS) and electron capture (GC-ECD)

OLIVEIRA, JUSTINE P.R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:50Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
18

Determinação da taxa de desintegração de Tc-99m e In-111 em sistemas de coincidências / Desintegration rate of Tc-99m and In-111 radioactive solutions in coincidence systems

BRITO, ANDREIA B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
19

Estudo dos poluentes orgânicos persistentes (POPS) em regiões industriais da Grande São Paulo - via cromatografia a gás acoplada a espectrometria de massas (GC-MS) e captura de elétrons (GC-ECD) / Study of persistent organic pollutants (POPs) in industrial areas of Greater São Paulo - via gas chromatography-mass spectrometry (GC-MS) and electron capture (GC-ECD)

OLIVEIRA, JUSTINE P.R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:50Z (GMT). No. of bitstreams: 0 / O estudo objetivou desenvolver e validar um método para identificar e quantificar poluentes orgânicos persistentes, conhecidos como POPs, em solo de regiões industriais dos municípios de Caieiras e Franco da Rocha SP, via cromatografia a gás acoplada a Espectrometria de Massas (GC-MS) e Detector por Captura de Elétrons (ECD). Em observância ao Tratado de Estocolmo, patrocinado pela Organização das Nações Unidas ONU, que prevê o banimento de pelo menos doze dos POPs, e no qual o Brasil é um dos 113 países signatários, o trabalho visou colaborar positivamente com essa questão ambiental tão importante. Estes compostos são tóxicos e altamente estáveis no ambiente e em organismos vivos, dentre os quais, são abordados nesse trabalho o clordano cis/trans (C10H6Cl8), o heptacloro (C10H5Cl7), o heptacloro epóxido cis/trans (C10H5Cl7) e os isômeros &alpha;-, &beta;-, &gamma;- e &delta;-BHC (C6Cl6). Para garantir a confiabilidade das análises realizadas, foram realizados ensaios de Validação da metodologia, com base nas diretrizes do INMETRO. A técnica de extração utilizada foi o QuEChERS, obtendo resultados de recuperação na faixa de 70 a 120% para a maioria dos compostos estudados, considerados aceitáveis para matrizes complexas. Os limites de detecção e quantificação do método compreenderam a faixa de 0,0002 e 0,01 &mu;g.g1, respectivamente. As amostras analisadas apresentaram contaminação pelos compostos hexaclorobenzeno &alpha;-, &beta;-, &gamma;- e &delta;-, muitas das quais estão acima dos limites máximos permissíveis, de acordo com as legislações nacionais e internacionais vigentes. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
20

Determinação da taxa de desintegração de Tc-99m e In-111 em sistemas de coincidências / Desintegration rate of Tc-99m and In-111 radioactive solutions in coincidence systems

BRITO, ANDREIA B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta os métodos de padronização de 111In e 99mTc, em sistemas de coincidências 4&pi;&beta;-&gamma;. O 111In foi produzido em cíclotron pela reação 111Cd(p, n)111In; decai com uma meia vida de 2,8 dias pelo processo de captura eletrônica populando os níveis excitados do 111Cd, emitindo raios gama de 171 keV e 245 keV. O 99mTc decai com uma meia vida de 6,007 h por transição isomérica do decaimento radioativo do 99Mo . A padronização do 111In foi feita no sistema 4&pi;&beta;-&gamma; constituído de um detector proporcional em geometria 4&pi; acoplado a dois cristais cintiladores de NaI(Tl) com eletrônica convencional. A radiação gama selecionada para medida em coincidência foi de (171 + 245) keV. A escolha da janela gama foi baseada na análise da previsão da curva de extrapolação obtida na simulação de Monte Carlo. A padronização do 99mTc foi feita num sistema 4&pi;&beta;-&gamma; usando um contador proporcional de janela fina acoplado a um cristal de cintilação NaI (Tl). A eficiência beta foi variada por discriminação eletrônica, usando sistema de coincidências por software (SCS). A padronização do 99mTc foi feita pela seleção de dois intervalos gama, um no pico de absorção total de 140 keV e outro no pico de absorção total dos raios X de 20 keV. O resultado da atividade experimental de duas soluções de 111In concorda com o resultado obtido pela simulação de Monte Carlo. As atividades experimentais do 99mTc para os dois intervalos gama selecionados estão de acordo dentro da incerteza experimental, indicando que a metodologia adotada é adequada. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0201 seconds