291 |
Hong Kong as a support base in the South China Sea oil explorations : research report.January 1982 (has links)
by Fung Wai-kan, Kai Siu-lung. / Abstract also in Chinese / Bibliography : leaves 106-108 / Thesis (M.B.A.)--Chinese University of Hong Kong, 1982
|
292 |
A practical bedsheet system for the non-contact and continuous monitoring of heart electric activities.January 2008 (has links)
Wu, Kin Fai. / Thesis (M.Phil.)--Chinese University of Hong Kong, 2008. / Includes bibliographical references (leaves 88-91). / Abstracts in English and Chinese. / Abstract --- p.i / 槪要 --- p.ii / Acknowledgements --- p.iii / Table of Contents --- p.iv / List of Figures --- p.vi / List of Tables --- p.x / Chapter Chapter 1 --- Introduction --- p.1 / Chapter 1.1 --- Motivation --- p.1 / Chapter 1.2 --- Outline of the Proposed Design --- p.2 / Chapter 1.3 --- Purposes of the Present Study --- p.2 / Chapter Chapter 2 --- Background and Literature Review --- p.4 / Chapter 2.1 --- Electrocardiogram --- p.4 / Chapter 2.2 --- Conventional ECG Measurement --- p.7 / Chapter 2.3 --- Heart Rate --- p.8 / Chapter 2.4 --- Heart Rate Variability --- p.9 / Chapter 2.5 --- Capacitive Sensing --- p.11 / Chapter 2.6 --- Review of ECG Monitoring System by Capacitive Sensing On a Sleeping Bed --- p.14 / Chapter Chapter 3 --- System Design and Implementation --- p.17 / Chapter 3.1 --- Hardware --- p.17 / Chapter 3.1.1 --- Bedsheet Sensor --- p.17 / Chapter 3.1.2 --- Pre-amplifier --- p.21 / Chapter 3.1.3 --- Measuring Device --- p.30 / Chapter 3.1.4 --- Power Supply & PCB Layout --- p.49 / Chapter 3.2 --- Software --- p.52 / Chapter 3.2.1 --- Detection of R Waves --- p.52 / Chapter 3.2.2 --- Tracking of HR & Mean RR Intervals --- p.55 / Chapter 3.2.3 --- Estimation of Signal-to-Noise Ratios --- p.56 / Chapter Chapter 4 --- Preliminary Tests on the Functionality of the Proposed System --- p.57 / Chapter 4.1 --- Test I - Test on the Arrangement of Electrodes --- p.57 / Chapter 4.1.1 --- Methods --- p.57 / Chapter 4.1.2 --- Results --- p.60 / Chapter 4.2 --- Test II - Test on the ECG Measurement of Subjects in Different Sleeping Postures --- p.64 / Chapter 4.2.1 --- Methods --- p.64 / Chapter 4.2.2 --- Results --- p.65 / Chapter Chapter 5 --- Experiments on the Performance of Continuous Monitoring of ECG and HR --- p.69 / Chapter 5.1 --- Experiment I - Experiment on the Reliability of the Proposed System for Continuous Monitoring of ECG and HR on Thirty Subjects --- p.69 / Chapter 5.1.1 --- Methods --- p.70 / Chapter 5.1.2 --- Results --- p.70 / Chapter 5.2 --- Experiment II - Experiment on the Feasibility of the Proposed System for Continuous Monitoring of ECG and HR on a Subject During an Eight-hour Sleep --- p.75 / Chapter 5.2.1 --- Materials --- p.76 / Chapter 5.2.2 --- Methods --- p.76 / Chapter 5.2.3 --- Results --- p.77 / Chapter Chapter 6 --- Discussions --- p.81 / Chapter 6.1 --- Selection of the Passband of the Proposed Circuit --- p.81 / Chapter 6.2 --- Arrangement of Electrodes on the Bedsheet --- p.82 / Chapter 6.3 --- Practical Design of Electrodes --- p.83 / Chapter 6.4 --- Performance of Continuous Monitoring of HR by Using the Proposed System --- p.84 / Chapter Chapter 7 --- Conclusion --- p.86 / References --- p.88
|
293 |
Trawl and gill net selectivity of yellow perch in southern Lake Michigan, 1993-2006Thomas, Nathan D. January 2007 (has links)
Selectivity of trawl and experimental gill nets was determined for yellow perch taken from southern Lake Michigan in 1993 to 2006. Gill nets were comprised of 51-, 64-and 76-mm size mesh and showed female modal lengths of 205-, 245-, and 295-mm, respectively, while values for males were 200-, 230-, and 267-mm. Differences between females and males increased with mesh size and was significant. Comparison of nine anterior morphometric features of female and male fish indicated no differences in shape were identified that would cause the disparity in selectivity. Rather, differences in male and female selectivity were more likely due the variant population size structure of the local population sampled, with females the larger sex. A new method to estimate trawl selectivity was developed using a modified catch-curve analysis, which showed a maximum selectivity length value (1.0) of 190-mm for females and 170-mm for males. However, trawls fail to capture larger yellow perch when compared to gill nets using based on length-frequency distributions. Revealing such gear biases may lead to more efficient capture methods, resulting in improved sampling and quantitative assessment of fish populations. / Department of Biology
|
294 |
Comparison of gill-net and trawl catch of the inshore fish community in southern Lake Michigan / Comparison of gill net and trawl catch of the inshore fish community in southern Lake MichiganMichaels, Samuel B. 24 July 2010 (has links)
Access to abstract permanently restricted to Ball State community only / Access to thesis permanently restricted to Ball State community only / Department of Biology
|
295 |
Influence of insertion/donning instruction on frequency-specific sound attenuation achieved with ear canal caps and earmuffs with implications for industrial noise applicationLam, Siu Tong January 1985 (has links)
A study was conducted to determine the dependency of sound attenuation capabilities of earmuffs and earcaps on various application instruction techniques including: (1) no instruction, (2) no instruction with 70 dBA auditory feedback, (3) manufacturers' package instruction, (4) detailed instruction, and (5) modeled instruction. The hearing protection devices (HPDs) studied were: two earcaps (Willson #20 Sound-Ban, Flents #055 Peace & Quiet Headband), and four earmuffs (E-A-R model 1000, Siebe Norton Industrial model 4540, Peltor H6A/v, and Willson 365A Sound Barrier). HPD comfort and wearer preferences were also assessed. Furthermore, typical excessive industrial machinery noises were sampled and analyzed across the 1/3 octave frequencies. Finally, an example is provided as to how these machinery noise spectra can be matched with HPD attenuation spectra to ascertain the protector which would afford optimal protection for a given noise situation.
Fifty subjects (twenty-five males and twenty-five females) participated in the experiment. Attenuation characteristics of the HPDs were evaluated utilizing the real-ear attenuation at threshold (REAT) method. A three-way mixed factorial design was used for data collection and analysis of attenuation results. Bipolar scales were used to assess individual HPD comfort, and the HPDs examined were ranked to obtain user preferences. In the analysis of attenuation results, analysis of variance CANOVA) and pairwise comparisons were utilized to detect statistical significance. The comfort scales and ranking scores were evaluated using the Friedman one-way block design.
Attenuation results for the earmuffs and earcaps tested showed that they were much less susceptible than earplugs (from a previous study by Epps, 1984) to changes in user insertion/donning instruction technique and also not as dependent on user gender. The main effect of gender was not significant, and in general, any instruction was better than no instruction at all but the effects of those instructions did not differ significantly among each other. As expected, there were main effect differences among the HPDs as to their attenuation capabilities, rated discomfort, and user preference. Because the main objective was on assessing donning instruction effects on HPD attenuation, the comfort/preference assessment was based on only a short (25 minutes) wearing time during the attenuation tests. Therefore, the comfort/preference ratings could likely vary given longer wearing periods and different work environments. All results found are discussed on the basis of the sample data obtained and conclusions drawn from these results should be limited to these experimental conditions and subsequent analyses, as actual attenuation achieved in practice may differ.
The example of HPD-machinery noise matching illustrates that the attenuation/spectral matching procedure may indeed be a feasible way of selecting optimal protection for workers. / Master of Science
|
296 |
A study of the seller and buyer relationship strategy in the Hong Kongbroadcast video equipment industryChan, Cheuk-ming, Jonathan., 陳卓明. January 1992 (has links)
published_or_final_version / Business Administration / Master / Master of Business Administration
|
297 |
Foundry Facilities in Industrial Arts Programs in the State of TexasLange, Robert Douglas 05 1900 (has links)
The problem of this study was to determine how much foundry equipment exists in the high schools of Texas and to determine to what extent it is being utilized. The data for this study were provided by thirty-seven metalworking instructors of Texas high schools.
Of the Texas high schools offering metalworking as a part of the industrial arts curriculum, few appear to have adequate foundry facilities. In addition, a deficiency seems evident in the background and training in foundry of the metalworking instructors.
|
298 |
A performance analysis of the hi-plan structural apparatusKashi, Mohsen Gholam-Reza January 1985 (has links)
Visual experience is a powerful pedagogic tool. Extensive use of experimental studies prior to design and construction has made conceptualization of complex structures possible. Experiments on reduced-scale structures and specimens are also vital tools for teaching structural mechanics. As such, the Department of Civil Engineering at Virginia Tech has acquired a new apparatus for use as an educational demonstration tool in the area of structural mechanics. This work presents the results of a detailed study on the performance of this device as related to its accuracy and operation.
To fulfill such objectives, two structural models (a continuous beam and a portal frame) were extensively tested under several loading and support configurations. The models were analysed using STRUDL as well as a computer program developed by the author. The comparison of the results (deformations) obtained in the two phases of the study have indicated that the apparatus is reasonably accurate to meet the requirements of a structural teaching model and adapting to a variety of structural models. / Master of Science / incomplete_metadata
|
299 |
INFRARED THERMOMETER TECHNIQUE TO EVALUATE DAILY SOIL HEAT FLUX IN SITU.Hares, Mohammed Abu. January 1982 (has links)
No description available.
|
300 |
Pneumatic conveying of flour mill stocksVenkataramana P. Reddy, 1949- January 2011 (has links)
Vita. / Digitized by Kansas Correctional Industries
|
Page generated in 0.029 seconds