Spelling suggestions: "subject:"rar, middle"" "subject:"aar, middle""
1 |
Pneumatic spaces in the petrous bone and their communications with the middle earForester, Harry Bible. January 1939 (has links)
Thesis (Ph. D.)--University of Wisconsin, 1939. / Typescript (carbon copy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves [i]-ii).
|
2 |
An experimental study of middle-ear vibrations in gerbilsEllaham, Nicolas. January 1900 (has links)
Thesis (M.Eng.). / Written for the Dept. of Biomedical Engineering. Title from title page of PDF (viewed 2008/05/13). Includes bibliographical references.
|
3 |
Two component acoustic reflex measures as a function of probe frequencyReynolds, Louise 19 April 2017 (has links)
No description available.
|
4 |
Evaluation of the Welch Allen Microtympanometer compared to conventional examination methods : the effect of general anaesthesia on microtympanograms and middle ear effusions : the use of tympanometry in pre-school audiological screening programmeBlack, John Henry 30 March 2017 (has links)
1) Test the accuracy of the Welch Allyn Microtympanometer against standard tympanometry. 2) Correlate preoperative clinical findings with: • Microtympanometry • Standard tympanometry 3) Assess influence of induction by gas anaesthesia on: • Post-induction microtympanometry • Intraoperative myringotomy findings 4) Assess the practicality of using the Welch Allyn Microtympanometer as a screening tool in Pre-School audiological testing.
|
5 |
Non-linear finite-element modelling of newborn ear canal and middle earQi, Li, January 1900 (has links)
Thesis (Ph.D.). / Written for the Dept. of BioMedical Engineering. Title from title page of PDF (viewed 2008/02/12). Includes bibliographical references.
|
6 |
Pre- and postoperative evaluation in middle ear surgeryHarris, Sten. January 1981 (has links)
Thesis (doctoral)--University of Lund, 1981.
|
7 |
Activity of middle ear muscles under certain pure tone and noise conditionsHatch, Marion Beryl January 1973 (has links)
This investigation was concerned with measurements of middle ear muscle activity. Specifically, the investigation was designed: (a) to compare reflex thresholds for pure tone(PT), octave band noise(OBN), and one-third octave band noise(TQBN); (b) to study middle ear muscle activity during a five minute exposure to these stimuli at 114 dB SPL; and (c) to compare middle ear muscle activity for stimuli of different frequencies.
Eighteen subjects were divided into two groups. Group I subjects were exposed to a 700 Hz PT, to OBN with center frequency 500 Hz, and TOBN with center frequency 630 Hz; Group II subjects were exposed to a 1400 Hz PT, to OBN with center frequency 1000 Hz, and TOBN with center frequency 1250 Hz.
A Madsen Electroacoustic Impedance Bridge and graphic recorder were used to record impedance changes during stimulation with the above stimuli. These impedance changes were assumed to reflect muscle activity. Thresholds for the acoustic reflex were determined using standard procedures.
Analysis of results indicated muscle activity decreased progressively during stimulation. Reflex decay was significantly greater for stimulation with PT than for stimulation with OBN(Groups I and II) and TOBN(Group II). It was noted that reflex decay was less during stimulation with a 700 Hz PT than during stimulation with a 1400 Hz PT.
Finally, it was observed that reflex thresholds were higher for PT than for OBN and TOBN.
Decrease in muscle activity during acoustic stimulation was discussed in terms of adaptation and possibly central mechanisms; the characteristics of the stimuli were compared and discussed, as a possible explanation for differences in results obtained for tones and noise. / Medicine, Faculty of / Audiology and Speech Sciences, School of / Graduate
|
8 |
Reflectância de orelha média na síndrome de Down / Wideband reflectance in Down syndromeSoares, Jordana Costa 13 August 2013 (has links)
INTRODUÇÃO: A síndrome de Down apresenta elevados índices de alteração da função da orelha média, bem como malformações congênitas na orelha externa, média e interna. Tais condições podem interferir na transmissão sonora pelo sistema tímpano-ossicular até a cóclea e vias auditivas centrais, afetando a compreensão da linguagem falada. Uma recente ferramenta de avaliação da orelha média, a reflectância de energia de faixa ampla, pode quantificar a energia sonora refletida ou absorvida no meato acústico externo ao longo de uma ampla faixa de frequências, mais rapidamente do que a timpanometria. OBJETIVO: Comparar as medidas de reflectância de energia de faixa ampla entre crianças com síndrome de Down e um grupo controle pareado por idade, de acordo com os achados timpanométricos. MÉTODOS: Foram analisados os dados de quatro grupos com síndrome de Down, entre 28 e 195 meses, sendo: timpanometria normal (19 orelhas), timpanometria plana (13 orelhas), timpanometria com pressão negativa moderada (6 orelhas), timpanometria com pressão negativa severa (4 orelhas). Todos os achados foram comparados a um grupo controle (21 orelhas). Os participantes foram submetidos aos exames de timpanometria e reflexo acústico ipsilateral com frequência de sonda de 226 Hz., audiometria tonal limiar, limiar de reconhecimento de fala, emissões otoacústicas evocadas por estímulo transiente e reflectância de energia na faixa de 200 a 6000 Hz. com estímulos do tipo chirp e tons puros. RESULTADOS: Os cinco grupos estudados exibiram diferentes padrões de curvas de reflectância de energia, sem diferença significativa em algumas comparações. Houve correlação negativa entre o volume do meato acústico externo e a reflectância com estímulo chirp entre 250 e 1600 Hz. e com o estímulo de tons puros entre 258 e 1500 Hz., e entre o pico de admitância da timpanometria e a reflectância com estímulo chirp em 500 e 1000 Hz. Não houve correlação entre as frequências da reflectância com estímulo chirp em 1000 e 2000 Hz e os resultados das emissões otoacústicas em 1000, 2000 Hz. e Response. A técnica de análise discriminante utilizada para classificar os dados dos participantes com base nos valores da reflectância com estímulo chirp em 1000 e 1600 Hz., alcançou um índice de classificação correta de 60% para os participantes com síndrome de Down. CONCLUSÕES: Foi possível caracterizar a curva de respostas da orelha média, para diferentes timpanogramas, na síndrome de Down, por meio da reflectância de energia de faixa ampla. Crianças com síndrome de Down com timpanograma normal apresentaram curva de reflectância semelhante ao grupo controle. A análise discriminante por meio dos resultados da timpanometria e reflectância com estímulo chirp em 1600 e 1000 Hz. classificou corretamente 60% dos dados pesquisados nas crianças com síndrome de Down / INTRODUCTION: Children with Down syndrome have high incidence of disorders of the middle ear, as well as congenital abnormalities in the external, middle and inner ear. Such conditions may change the sound transmission through the ossicular chain to the cochlea and central auditory pathways, impairing the comprehension of spoken language. An recent assessment tool of the middle ear, the wideband reflectance energy, can measure the sound energy reflected or absorbed in the ear canal over a wide frequency range, faster than tympanometry. OBJECTIVE: To compare the wideband reflectance measurements between children with Down syndrome and a control group matched by age, according to the tympanometric findings. METHODS: This study evaluated four groups with Down syndrome, between 28 and 195 months: normal tympanogram (19 ears), flat tympanogram (13 ears), moderate negative pressure tympanogram (6 ears), severe negative pressure tympanogram (4 ears). All findings were compared to a control group (21 ears). The subjects underwent to tympanometry and acoustic reflex ipsilateral with a 226 Hz probe tone frequency, pure tone audiometry, speech recognition thresholds, transient otoacoustic emissions and wideband reflectance over the 200-6000 Hz range with chirp and tone stimuli. RESULTS: Results revealed that the five groups had different reflectance curves, without significant difference in some comparisons. There was a negative correlation between the volume of the external auditory meatus and the wideband reflectance with the chirp stimulus between 250 and 1600 Hz and with the tone stimulus between 258 and 1500 Hz, and between the static acoustic admittance at the tympanic membrane level and the wideband reflectance with chirp stimulus at 500 and 1000 Hz. There was no correlation between the frequency of the chirp stimulus with reflectance at 1000 and 2000 Hz and the results of the otoacoustic emissions at 1000, 2000 Hz and general response. The discriminant analysis technique used to classify participants\' data based on the values of reflectance with chirp stimulus in 1000 and 1600 Hz, achieved a correct classification rate of 60% for participants with Down syndrome. CONCLUSIONS: The findings showed the responses of the middle ear, for different tympanograms in Down syndrome through the wideband reflectance. In this study, children with Down syndrome and normal tympanogram showed wideband reflectance curve similar to the control group. A discriminant analysis with the tympanometric results and reflectance with chirp stimulus at 1600 and 1000 Hz correctly classified 60% of the data for children with Down syndrome
|
9 |
Função da orelha média e das curvas de crescimento nas respostas das emissões otoacústicas / Middle-ear and growth functions on the responses of the otoacoustic emissionsCampos, Ualace de Paula 28 June 2011 (has links)
INTRODUÇÃO: Dentre as medidas da função coclear, a curva de crescimento das Emissões Otoacústicas por produto de distorção (CCEOA PD) permite o registro da amplitude da emissão em função do crescimento sistemático nos níveis de tons primários. A CCEOA PD fornece parâmetros específicos sobre o limiar e o comportamento não-linear das EOA PD, porém a variabilidade das respostas inter e intrasujeitos reduz a confiabilidade dessa medida na avaliação da robustez das respostas cocleares e a relação dessa robustez com os limiares auditivos. OBJETIVOS: Esta pesquisa estudou as interações entre as medidas timpanométricas da orelha média e as medidas de função coclear em adultos jovens sem queixas auditivas, de acordo com as variáveis: antecedentes de alterações de orelha média, sexo e orelha direita / esquerda. MÉTODOS: Participaram 69 indivíduos com audição normal e idades entre 18 e 34 anos, sendo 21 homens e 48 mulheres. A caracterização das condições de orelha média foi obtida pela anamnese, com a informação dos antecedentes de alterações de orelha média e pela timpanometria com sondas de admitância de 226 e 1000 Hz. A audiometria foi realizada com resolução de 01 dB NA, o que possibilitou comparações mais refinadas entre o limiar psicoacústico da audiometria tonal, a amplitude do DP-Gram e os limiares das CCEOA PD. Além dessas variáveis, a interferência dos fatores sexo e orelha foram testadas em todas as análises. RESULTADOS/DISCUSSÃO: Os resultados apontaram que as curvas de crescimento sofreram influência significativa das variáveis sexo, antecedentes de alterações de orelha média e orelha direita \\ esquerda, porém, apenas a interferência dos antecedentes foi constante e causou um padrão de modificação, ou seja, o grupo com antecedentes apresentou respostas aquém das respostas do grupo sem antecedentes. Os limiares audiométricos também apresentaram alta correlação com as amplitudes das EOA PD e com os limiares das CCEOA PD, quando identificadas as variáveis que interferiram nos resultados. Considerando que o ruído de fundo foi controlado nessa pesquisa, durante a avaliação das EOA PD e CCEOA PD, os resultados confirmaram a importância da consideração dessas variáveis na composição de grupos com audição normal em pesquisas com medidas de emissões otoacústicas. Ainda sobre os resultados, foi possível, por meio da medida da curva de crescimento (slope e limiar), demonstrar que o padrão de crescimento das CCEOA PD é diferente nos casos de modificação nas condições de orelha média e isso foi verificado tanto pelos antecedentes de alterações de orelha média quanto pelas medidas timpanométricas com sonda de admitância de 1000 Hz. CONCLUSÃO: O limiar das CCEOA - PD estudado nessa pesquisa apresentou correlação positiva com valores audiométricos e negativa com o DP-Gram. A inclinação da curva de crescimento (slope) também apresentou alta correlação com os antecedentes de alterações de orelha média, apontando o potencial valor desta medida no estudo da função coclear saudável e alterada e, conseqüentemente, sua possível utilização nas medidas prescritivas de amplificação / INTRODUCTION: The Distortion Product Otoacoustic Emissions Input/Output function (DPOAE I/O function) is a subdivision of DPOAE, where the response amplitude is recorded such as a systematic growth function in the primary tones. The DPOAE I/O function provides specific parameters about the DPOAEs threshold and non-linearity. However, the response variability reduces the measure reliability to evaluate the cochlear robustness and the relationship between robustness and hearing thresholds. OBJECTIVE: This research studied the interaction between the tympanometric measures and cochlear functions measures in young adults without hearing complaints, considering the variables: middle-ear alteration antecedents, gender and right / left ear. METHODS: 69 normal hearing subjects, aged from 18 to 34 years participated of the study. From the total, 21 were men and 48 women. To reach the proposed objectives, the middle ear conditions were assessed by anamneses and 226 and 1000 Hz admittance probe-tone tympanometry. The audiometric thresholds were searched with 01 dBHL resolution to enable refined comparisons among pure-tone audiometry and DP-Gram amplitude and DPOAE I/O function thresholds. The gender and ear interference were also evaluated in all analyses. RESULTS/DISCUSSION: The results showed that the variables gender, antecedents and ear affected the I/O functions responses, but only the middle-ear alterations antecedents presented a constant modification pattern. In other words, the group with antecedents presented mainly reduced responses in comparison with no antecedents group. The audiometric thresholds also presented high correlation with DPOAE amplitudes and DPOAE I/O functions thresholds, after the detection of the variables affecting the results. As the background noise was controlled during this study, the results confirmed the importance of monitoring these variables in the normal hearing group compositions to perform researches with DPOAE. Regarding the DPOAE I/O functions (slope and threshold), the growth pattern was modified according the middle ear conditions, verified by the antecedents of middle ear alterations and 1000 Hz admittance probe-tone tympanometry. CONCLUSION: The DPOAE I/O function threshold studied presented positive correlation with audiometric thresholds and negative correlation with DP-Gram. The DPOAE I/O functions slope also showed high correlation with antecedents of middle ear alterations, denoting the potential value of this measure in the study of the healthy and damaged cochlear function and, hence, it possible application in amplification prescriptive measures
|
10 |
Inflammatory mediator response to Gram-positive and Gram-negative bacteria in vitro and in middle ear infectionsSkovbjerg, Susann, January 2010 (has links)
Diss. (sammanfattning) Göteborg : Göteborgs universitet, 2010.
|
Page generated in 0.0457 seconds