1

Modélisation du comportement des micropolluants dans une station d'épuration

Cloutier, Frédéric 18 April 2018 (has links)
Le but de ce travail était de modéliser le comportement de micropolluants en plus des polluants traditionnels dans une station d'épuration. Deux études de cas ont ainsi été réalisées. La première concerne une usine pilote de la station d'épuration de Lynetten à Copenhague, au Danemark. Un modèle tenant compte à la fois de la dégradation aérobie par une bactérie spécifique et de la sorption sur les matières en suspension a été développé afin d'y décrire le comportement de composés organiques xénobiotiques. Les expériences ont été effectuées avec un perturbateur endocrinien, le Bisphénol A. Les résultats démontrent que le modèle parvient à représenter adéquatement la dynamique d'enlèvement du Bisphénol A. Le processus utilisé pour évaluer l'adaptation de la biomasse afin de valider le modèle n'épouse pas parfaitement les données mesurées, mais il permet toutefois de prédire la structure générale du comportement du Bisphénol A. La seconde étude concerne la station de Norwich, au Royaume-Uni. Dans ce cas-ci, le modèle, qui considère la sorption des métaux lourds sur les matières en suspension comme processus réactionnel, a été évalué à partir de données recueillies à même la station. Les résultats démontrent la grande sensibilité du modèle face aux variations instantanées des concentrations de métaux lourds dans l'affluent. Il est néanmoins capable de prévoir l'évolution des concentrations des métaux lourds à l'intérieur de la station ainsi qu'à l'effluent.
2

Greenhouse gas emissions from and storm impacts on wastewater treatment plants : process modelling and control

Guo, Li Sha 20 April 2018 (has links)
Cette thèse étudie l'interaction entre les stations d’épuration (STEP) et le changement climatique: soit en premier lieu la production ainsi que les émissions de gaz à effet de serre (GES), en particulier le protoxyde d’azote (N2O), généré à la STEP et en second lieu l’effet des pluies plus intenses dues aux changements climatiques sur la STEP. Des campagnes de mesure sur le terrain et la modélisation à échelle réelle ont été utilisées conjointement dans cette recherche. Une campagne de mesure d'une durée d’un mois a été réalisée dans une STEP traitant les eaux usées de 750,000 équivalents habitants, soit la STEP d’Eindhoven aux Pays-Bas. Des capteurs en ligne ont été installés dans la zone d'aération du bioréacteur. Une usine virtuelle de grande échelle, soit la STEP décrit par le Benchmark Simulation Model No.2 (BSM2), ainsi qu’une usine réelle de grande échelle, soit la STEP d’Eindhoven aux Pays-Bas, étaient incluses dans cette étude. Dans les deux cas, les modèles ont été modifiés afin de prendre en compte les GES, en particulier la production de N2O. Deux modèles de boues activées (ASM) ont été développés, soit l’ASMG1 et l’ASMG2d. En plus de la conversion de N2O par les bactéries hétérotrophes, les deux modèles sont en mesure de simuler la production de N2O par la dénitrification catalysée par les bactéries oxydant l'ammoniac (AOB). Les modèles décrivent aussi l'effet de l’oxygène dissous (OD) sur la cinétique de production de N2O par les AOB grâce à une modification de la cinétique d’Haldane. Les résultats montrent que les AOB produisent beaucoup de N2O tandis que les hétérotrophes en consomment considérablement. Les émissions de N2O augmentent lorsque les concentrations de NH4+ sont élevées et que les concentrations d’OD sont modérées (jusqu’à 2.5 mg O2/l dans cette étude). Ces conditions peuvent avoir été créées par le contrôle en cascade de NH4+-OD qui vise à réduire la consommation d'énergie en diminuant les concentrations d'OD lorsque la concentration de NH4+ est suffisamment faible. En outre, ce contrôleur en cascade est une stratégie de rétroaction à gain faible. C'est-à-dire, un retard significatif se produit entre la détection d'une augmentation de NH4+ et l'accroissement de l'aération. Toutes ces propriétés produisent des conditions favorables à la production de N2O par les bactéries AOB. Différents scénarios alternatifs ainsi que des stratégies de contrôle ont été comparés selon la qualité de l'effluent, le coût d’opération et les émissions de GES. Dans le cadre de BSM2, un bon équilibre entre la qualité de l'effluent, le coût d’opération et les émissions de GES a été obtenu avec à la mise en œuvre d'un contrôleur rétroactif pur de l’OD sur la première zone d'aération et d’un contrôleur en cascade de NH4+-DO sur les deux zones d'aération suivantes et en utilisant soit une stratégie d'alimentation étagée ou le contrôle du recyclage des boues afin de gérer les pics de débits. Mots-clés: Traitement des eaux usées par boues activées, contrôle de procédé, campagne de mesures en terrain, modélisation mathématique à échelle grandeur réelle, gaz à effet de serre, protoxyde d’azote, temps de pluie. / This PhD thesis studied the interaction between wastewater treatment plants (WWTPs) and climate change, i.e. the production and emission of greenhouse gases (GHGs), especially nitrous oxide (N2O), from WWTPs and the effect of the climate change induced more intense rain events on WWTPs. Both field measurements and full-scale modelling were pursued in this research. A one-month measurement campaign was performed by installing on-line sensors at the aeration zone of the bioreactor of a 750,000 person equivalents WWTP, i.e. the Eindhoven WWTP in the Netherlands. The models of a full-scale virtual plant, i.e. the Benchmark Simulation Model No.2 (BSM2), and a full-scale real plant, i.e. the Eindhoven WWTP in the Netherlands, were extended with respect to GHG emissions, especially the pathways involving N2O. Two types of extended Activated Sludge Models (ASM) were developed, i.e. ASMG1 for COD/N removal and ASMG2d for COD/N/P removal. Besides heterotrophic N2O production, both proposed models include N2O production by nitrite denitrification by ammonia-oxidizing bacteria (AOB) and describe the DO effect on AOB N2O production by a modified Haldane kinetics term. Results showed that AOB are the major producer of N2O while the heterotrophs consume N2O considerably. The high N2O emissions occurred under high NH4+ and intermediate DO concentrations (up to 2.5 mg O2/l in this work). Such conditions can be created by NH4+-DO cascade control which aims at reducing energy consumption by lowering the DO concentrations when the NH4+ concentration is sufficiently low. Moreover, this cascade controller is a low-gain feedback control strategy, i.e. a significant delay will occur between the detection of a NH4+ increase and the increase in aeration. All these properties lead to conditions favourable to N2O production by AOB. Different alternative scenarios and control strategies were compared in terms of effluent quality, operational cost and GHG emissions. In the framework of BSM2, a good balance among effluent quality, operational cost and GHG emissions was realized by implementing a pure DO feedback controller in the first aeration zone and a NH4+-DO cascade controller in the following two aeration zones and using either step feed or sludge recycling control to deal with hydraulic shocks. Keywords: Activated sludge, wastewater treatment, process control, field measurements, full-scale mathematical modelling, greenhouse gases, nitrous oxide, wet weather conditions.
3

Caractérisation de la matière organique des eaux naturelles et traitées par spectroscopie de fluorescence 3D

Bernier, Annie 23 April 2018 (has links)
Cette étude porte sur la caractérisation de la matière organique dans les eaux naturelles et traitées avec la technique de spectroscopie de fluorescence 3D. Au total, deux usines ont été étudiées entre 2009 et 2011: Usine du Secteur-centre de la ville de Québec, Usine de traitement des eaux potables de Victoriaville. Les paramètres de qualité d’eau mesurés sont la turbidité à l’eau brute, l’absorptivité UV, le carbone organique dissous, le carbone organique dissous biodégradable et la fluorescence. Cette étude utilise la fluorescence afin de démontrer son potentiel pour suivre les variations de la nature de la MON dans une source d’eau de surface et en cours de traitement. Les données de fluorescence ont été analysées par deux méthodes: par pic (maximums locaux) et par déconvolution 3D en fluorophores unitaires (Parallel factor analysis – PARAFAC). La fluorescence s’avère un outil utile pour évaluer l’efficacité du traitement. / This study focuses on the characterization with fluorescence spectroscopy of the organic matter in natural and treated waters. In this study, two Drinking Water Treament Plants (DWTP) were studied between 2009 and 2011: DWTP of Quebec City, DWTP of Victoriaville. The main parameters to monitor water quality are raw water turbidity, UV absorbance, dissolved organic carbon, biodegradable dissolved organic carbon and fluorescence. Fluorescence spectroscopy is a simple and rapid technique that requires very little sample preparation and that can help in monitoring the organic matter through treatment, specifically some fractions such as humic acids, fulvic acids and amino acids associated with proteins as tryptophan and tyrosine. Fluorescence could also be used to monitor continuously in DWTP and be a good indicator of the effectiveness of treatment.
4

Comparaison à l'échelle réelle des performances d'un filtre conventionnel et d'un filtre au charbon activé en grains précédés d'une inter-ozonation

Déry, Alexandre 19 April 2018 (has links)
Un suivi de deux filtres granulaires pleine échelle a été fait à une des usines de production d’eau potable de la Ville de Québec qui a une capacité de production de plus de 220 000 m3/jour. Un des filtres contient du sable et de l’anthracite, et l’autre du sable et du charbon activé en grains (CAG). Les deux filtres, qui sont précédés d’une inter-ozonation, ont été opérés dans les mêmes conditions pendant l’étude. Les qualités de l’eau brute, décantée, ozonée et filtrée ont été suivies pendant 32 semaines, de mai à décembre 2011, à raison de 2 échantillonnages dans un cycle de filtration à chaque deux semaines. Cette période correspond à peu près à la deuxième année d’opération après le changement des milieux filtrants dans cette usine. Le filtre avec CAG s’est avéré plus performant pour presque tous les paramètres de qualité d’eau considérés, en particulier en termes d’enlèvement de la matière organique biodégradable et non-biodégradable. Par contre, et contrairement à ce qui a été observé antérieurement, la réduction de la turbidité a été plus forte dans le filtre avec anthracite. Une analyse économique préliminaire et partielle montre que le meilleur enlèvement de la matière organique réalisé par le filtre avec CAG pourrait amener une économie significative due à une réduction de la demande en chlore mais que celle-ci serait masquée par le coût d’achat très élevé du CAG par rapport à l’anthracite. / A water quality monitoring was conducted on two full scale granular filters of the biggest water treatment plant of Québec City. One of the filters contains anthracite and sand layers, while the other contains granular activated carbon (GAC) and sand layers. Both filters, which are preceded by an inter-ozonation step, were operated in the same conditions during the study which happened during the second year of operation of these filters. The qualities of raw water, settled water, ozonated water and filtered water were monitored for 32 weeks, from May to December 2011, two times in a filtration cycle every two weeks. Globally, the GAC filter exhibited better organic matter removal performances but a lower turbidity removal performance than the anthracite filter. This allows a potential reduction in chlorine consumption for the GAC filter but this economy is shadowed by the very high cost of this filter media.