• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 11
  • 2
  • Tagged with
  • 52
  • 52
  • 16
  • 12
  • 10
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Méthodes statistiques applicables à la recherche de l'évolution des paramètres de qualité des eaux superficielles : application à des données relatives au bassin du Rhône français.

Cochet, Yannick, January 1900 (has links)
Th. 3e cycle--Pharm., métrol. des polluants dans l'aliment. et l'environ.--Montpellier 1, 1981.
2

Modélisations numérique et expérimentale du ruissellement : effet de la rugosité sur les distances de transfert /

Darboux, Frédéric. January 1999 (has links)
Th. univ.--Rennes 1, 1999. / Textes en français ou en anglais. Bibliogr. p. 161-170. Notes bibliogr. Résumés en français et en anglais.
3

Étude des transferts dispersifs en estuaire par simulation numérique.

Meyer-Branski, Joël, January 1900 (has links)
Th. doct.-ing.--Méc.--Toulouse--I.N.P., 1981 : 181.
4

Devenir du phosphore apporté sur les sols et risques de contamination des eaux de surface : cas des boues de stations d'épuration /

Vanden Bossche, Hugues. January 2003 (has links)
Th. doct.--Rennes 1, 1999. / Contient des textes en anglais. Bibliogr. p. 273-291. Résumé en français et en anglais.
5

Contribution des eaux souterraines aux débits et à la qualité des eaux de surface : exemple de la Garonne, de ses sources à la confluence du Tarn /

Danneville, Laurent. January 1997 (has links)
Th. univ.--Sci.--Paris 11, 1995. / Bibliogr. p. 327-336. Résumé en français et en anglais.
6

Simulation numérique des échanges rivière-nappe alluviale en présence d'une ballastière : essai méthodologique.

Khammari, Boudjema, January 1900 (has links)
Th. doct.-ing.--Nancy, I.N.P.L., 1978.
7

Performances des pratiques de gestion optimales des eaux pluviales : cas du stationnement Roland-Beaudin

Hamidou, Rachida 19 September 2022 (has links)
Cette étude de cas réalisée au complexe sportif de Ste-Foy avait pour objectif principal d'évaluer les performances hydrauliques et épuratoires des pratiques de gestion optimales (PGOs), en l'occurrence des systèmes de bio-rétention, dans un climat nordique comme au Québec. À partir de cet objectif général, plusieurs objectifs spécifiques ont été ressortis. Sur le plan qualitatif, il s'agissait d'effectuer la caractérisation du ruissellement urbain, la mesure de l'impact d'une fosse de décantation et enfin l'étude de l'homogénéité des polluants sur un stationnement. Les concentrations en polluants obtenues sont de façon générale, 22 à 317 mg /L pour les matières en suspension (MeS), < 0,3 à 2,6 mg/L pour l'azote total (NT), < 0,03 à 1,74 mg/L pour le phosphore total (PT) et 36 à 419 mg/L pour la demande chimique en oxygène (DCO). Ces différentes concentrations ont été obtenues à l'entrée ayant la plus grande aire tributaire. En effet, les concentrations en polluants ne sont pas homogènes sur tout le stationnement et dépendent des facteurs tels que le trafic et l'aire de drainage. Par ailleurs, la fosse de décantation n'a pas eu d'impact sur la concentration en MeS. L'efficacité épuratoire de la bio-rétention n'a pu être démontrée en raison des conditions du site. / The main objective of this case study at the Ste-Foy sports complex was to evaluate the hydraulic and purification performance of best management practices, in this case bio-retention systems in a northern climate such as Quebec. From this general objective, several specific objectives have emerged. Qualitatively, the objective was to characterize urban runoff, measuring the impact of a settling pit and finally studying the homogeneity of pollutants on a parking lot. The pollutant concentrations obtained are from 22 to 317 mg /L for suspended matter (SS), < 0.3 to 2.6 mg /L for total nitrogen (TN), < 0.03 to 1.74 mg /L for total phosphorus (TP) and 36 to 419 mg /L for chemical oxygen demand(COD). These different concentrations were obtained at the entrance with the largest tributary area. Indeed, pollutant concentrations are not homogeneous throughout the parking lot and depend on factors such as traffic and drainage area. In addition, the settling pit had no impact on the SS concentration. The performance of the bio-retention could not be demonstrated due to site conditions.
8

Performances des pratiques de gestion optimales des eaux pluviales : cas du stationnement Roland-Beaudin

Hamidou, Rachida 13 December 2023 (has links)
Cette étude de cas réalisée au complexe sportif de Ste-Foy avait pour objectif principal d'évaluer les performances hydrauliques et épuratoires des pratiques de gestion optimales (PGOs), en l'occurrence des systèmes de bio-rétention, dans un climat nordique comme au Québec. À partir de cet objectif général, plusieurs objectifs spécifiques ont été ressortis. Sur le plan qualitatif, il s'agissait d'effectuer la caractérisation du ruissellement urbain, la mesure de l'impact d'une fosse de décantation et enfin l'étude de l'homogénéité des polluants sur un stationnement. Les concentrations en polluants obtenues sont de façon générale, 22 à 317 mg /L pour les matières en suspension (MeS), < 0,3 à 2,6 mg/L pour l'azote total (NT), < 0,03 à 1,74 mg/L pour le phosphore total (PT) et 36 à 419 mg/L pour la demande chimique en oxygène (DCO). Ces différentes concentrations ont été obtenues à l'entrée ayant la plus grande aire tributaire. En effet, les concentrations en polluants ne sont pas homogènes sur tout le stationnement et dépendent des facteurs tels que le trafic et l'aire de drainage. Par ailleurs, la fosse de décantation n'a pas eu d'impact sur la concentration en MeS. L'efficacité épuratoire de la bio-rétention n'a pu être démontrée en raison des conditions du site. / The main objective of this case study at the Ste-Foy sports complex was to evaluate the hydraulic and purification performance of best management practices, in this case bio-retention systems in a northern climate such as Quebec. From this general objective, several specific objectives have emerged. Qualitatively, the objective was to characterize urban runoff, measuring the impact of a settling pit and finally studying the homogeneity of pollutants on a parking lot. The pollutant concentrations obtained are from 22 to 317 mg /L for suspended matter (SS), < 0.3 to 2.6 mg /L for total nitrogen (TN), < 0.03 to 1.74 mg /L for total phosphorus (TP) and 36 to 419 mg /L for chemical oxygen demand(COD). These different concentrations were obtained at the entrance with the largest tributary area. Indeed, pollutant concentrations are not homogeneous throughout the parking lot and depend on factors such as traffic and drainage area. In addition, the settling pit had no impact on the SS concentration. The performance of the bio-retention could not be demonstrated due to site conditions.
9

Impacts des conditions hydrométéorologiques sur la qualité des eaux de surface d'un bassin versant mixte agricole-forestier de l'Est du Canada

Brault, Benoit 12 April 2024 (has links)
Titre de l'écran-titre (visionné le 27 avril 2023) / Une eau de qualité adéquate est essentielle au maintien de la vie aquatique et à un approvisionnement en eau potable salubre. La plupart des travaux passés portant sur la qualité de l'eau des rivières reposent sur des échantillonnages occasionnels, ce qui peut entraîner une incertitude considérable lors de l'estimation des charges en polluants à l'échelle annuelle. L'objectif de cette étude est d'identifier et quantifier l'impact des conditions hydrométéorologiques (e.g. pluie et fonte de la neige) sur les paramètres physico-chimiques de l'eau de rivière d'un bassin versant mixte agricole-forestier à partir d'observations à haute fréquence. Le site d'étude est le bassin versant de la rivière Beaurivage de 709 km² dans le sud du Québec (46,66°N; 71,29°O), en amont d'une importante prise d'eau municipale, et dont l'occupation du sol est dominée par la forêt (52%) et des champs agricoles (41%). Une campagne de terrain a eu lieu de décembre 2020 à mars 2022, avec des mesures en continu du débit, de la turbidité et de la conductivité électrique dans l'eau, et le suivi des conditions météorologiques. Au cours de 12 événements hydrométéorologiques associés à la dégradation de la qualité de l'eau (10 événements de pluie et 2 crues printanières), des mesures intensives de plusieurs paramètres de la qualité de l'eau ont été effectuées. Nos résultats montrent qu'il est possible d'estimer la concentration en azote total, en matière en suspension et en phosphore total à partir d'une relation empirique avec le débit. Pour chacune de ces relations, un point de rupture à 18,4 m³ s⁻¹ suggère qu'il y a deux phases ou plus dans la dynamique de transport des contaminants. Il est aussi possible d'estimer la concentration en carbone organique total à partir de la conductivité, et le nombre le plus probable de Escherichia coli dans l'eau à partir de la turbidité. Les résultats indiquent aussi que la charge événementielle de l'azote total, du carbone organique total, de la matière en suspension et du phosphore total peut être estimée par une relation empirique avec le 3ᵉ quartile de la distribution des débits enregistrés pendant un événement. Enfin, le bilan de la charge totale annuelle pour l'année 2021 est de 1 [0,5, 1,4] tonne N km⁻² pour l'azote total, de 14 [9, 18] tonnes C km⁻² pour le carbone organique total, de 34 [20, 70] tonnes km⁻² pour la matière en suspension et de 90 [55, 171] kg P km⁻² pour le phosphore total. / An adequate water quality is essential to maintain aquatic life and to supply safe drinking water. Most studies on river water quality are based on occasional sampling, which can bring considerable uncertainty when estimating pollutants concentrations or annual loads. The objective of our research is to identify and quantify the impact of hydrometeorological conditions (e.g. rain and snowmelt) on physico-chemical parameters of a river in a mixt agricultural-forest watershed based on high frequency observations. The study site is the Beaurivage river watershed (709 km² ) in the south of the province of Québec (46,66°N; 71,29°W). This watershed is mostly occupied by forest (52%) and agricultural fields (41%), and it is located upstream of a drinking water facility. A field campaign took place between December 2020 and March 2022 to obtain continuous measurement of the river flow, turbidity and electric conductivity, and the monitoring of meteorological conditions. During 12 hydrometeorological events associated with water quality degradation (10 rain and 2 snowmelt events), measurements of multiple water quality parameters have been carried out. Our results show that it is possible to estimate total nitrogen, suspended sediments and total phosphorus concentration with an empirical relation with the flow. For each of these relations, a fracture point at 18,4 m³ s⁻¹ suggested that there are two or more phases in the dynamic transport of contaminants. Also, it is possible to estimate the total organic carbon concentration with a relation using the conductivity, and the most probable number of E. coli in the river water using the turbidity. The results also indicate that the event load of total nitrogen, total organic carbon, suspended sediments and total phosphorus can be estimated with a empirical relation using the 3ᵗʰ quartile of the event flow distribution. Finally, the total annual load for the year 2021 is 1 tonne N/km² for the total nitrogen, 14 tonnes C/km² for the total organic carbon, 34 tonnes/km² for the suspended sediments and 90 kg P/km² for the total phosphorus.
10

Analyse spatiale de la composition chimique des ruisseaux vosgiens

Nedeltcheva, Théodora Dambrine, Etienne. January 2005 (has links) (PDF)
Thèse doctorat : Géosciences et Environnement : Nancy 1 : 2005. / Titre provenant de l'écran-titre.

Page generated in 0.0638 seconds