• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bioaérosols viraux dans les usines de traitement des eaux usées : détection moléculaire et métagénomique

Brisebois, Evelyne 24 April 2018 (has links)
Les travailleurs des centres de traitement des eaux usées sont souvent atteints de maladies reliées à l’exposition virale telles que le rhume, la grippe et les infections gastro-intestinales. Dans la littérature, plusieurs études ont caractérisé les bactéries présentes dans les eaux usées ainsi que les bactéries dans les aérosols de ces centres de traitement. Les virus dans les eaux usées ont aussi été dans la mire de certaines études. Cependant, malgré le fait que les maladies affectant les travailleurs soient majoritairement de cause virale et que certains virus pathogènes aient été démontrés pour être capables de se transmettre par l’air, seule une minime quantité d’études a décrit jusqu’à présent les aérosols viraux de ces environnements. Qu’en est-il des virus aérosolisés qui peuvent provoquer ces maladies chez les travailleurs? Auxquels virus potentiellement pathogènes les travailleurs sont-ils exposés chaque jour dans ces environnements de travail? Cette étude avait pour but d’échantillonner l’air de quatre centres de traitement des eaux usées à l’aide de différents échantillonneurs pour décrire la communauté virale dans les aérosols et, ultimement, d’identifier les virus aérosolisés qui peuvent mettre en danger la santé des travailleurs. Onze virus ont été sélectionnés en fonction de leur présence dans les eaux usées et quantifiés de manière spécifique par une technique de biologie moléculaire appelée qPCR. De plus, une étude métagénomique a été effectuée sur des échantillons d’air de très grands volumes dans l’une des usines à l’étude afin de caractériser les communautés virales totales présentes dans l’air des centres de traitement. Les échantillons d’air ont été pris à deux reprises dans chaque centre, une fois durant la saison d’été et une fois durant la saison d’hiver afin de déterminer l’effet de la température de l’eau sur le type de virus aérosolisés. / Wastewater treatment center (WTCs) workers may be vulnerable to diseases caused by viruses, such as the common cold, influenza and gastro-intestinal infections. Although there is a substantial body of literature characterizing the microbial community found in wastewater, only a few studies have characterized the viral component of WTC aerosols, despite the fact that most diseases affecting WTC workers are of viral origin and that some of these viruses are transmitted through the air. In this study, we evaluated in four WTCs the presence of 11 viral pathogens of particular concern in this milieu and used a metagenomic approach to characterize the total viral community in the air of one of those WTCs. The presence of viruses in aerosols in different locations of individual WTCs was evaluated and the results obtained with four commonly used air samplers were compared. We detected four of the eleven viruses tested, including human adenovirus (hAdV), rotavirus, hepatitis A virus (HAV) and Herpes Simplex virus type 1 (HSV1). The results of the metagenomic assay uncovered very few viral RNA sequences in WTC aerosols, however sequences from human DNA viruses were in much greater relative abundance.
2

Probabilistic design of wastewater treatment plants

Talebizadehsardari, Mansour 23 April 2018 (has links)
Dans cette étude, une méthode de conception probabiliste pour la conception d'usines de traitement des eaux usées (STEP) qui permet la quantification du degré de conformité aux normes de rejet en termes de probabilité a été proposée. La méthode de conception développée est une approche basée sur un modèle dans lequel les sources pertinentes d'incertitude sont exprimées en termes de fonctions de distribution de probabilité et leur effet combiné sur la distribution de la qualité de l'effluent sont quantifiés par simulation Monte Carlo. Pour ce faire, une série de conceptions en régime permanent avec différents niveaux de sécurité ont été générés en utilisant des règles de conception et la probabilité correspondante de non-conformité aux normes de rejet ont été calculés en utilisant des simulations dynamiques avec différentes réalisations de séries temporelles d'affluent et différentes valeurs pour les paramètres du modèle de station d'épuration. Pour générer différentes réalisations de séries temporelles d'affluent, un logiciel a été développé pour la génération de séries temporelles d'affluent tenant compte des conditions climatiques locales ainsi que les caractéristiques de base des réseaux d'égout connectés. En outre, différentes réalisations des paramètres du modèle de STEP ont été générés par l'échantillonnage des fonctions de distribution de probabilité et l'effet combiné de la variabilité de l'affluent et l'incertitude du modèle sur la distribution de la qualité des effluents a été calculé en exécutant un certain nombre de simulations Monte Carlo jusqu'à ce que la convergence de la distribution de la qualité des effluents a été atteinte. Une fois la convergence atteinte, la probabilité de non-respect d'une alternative de conception peut être calculée pour un certain niveau de qualité de l'effluent. La méthode de conception probabiliste peut aider les concepteurs à éviter l'application de facteurs de sécurité conservateurs qui pourraient entraîner un dimensionnement trop petit ou trop grand de stations d'épuration. En outre, le calcul de la probabilité de non-conformité comme un critère quantitatif peut aider les concepteurs et les décideurs à prendre une décision informée des risques en vue de la meilleure configuration de traitement, son dimensionnement, ainsi que le fonctionnement de l'usine pour la conception ou la mise à niveau des stations d'épuration. Mots-clés: usine de traitement des eaux usées, de conception dans l'incertitude, de la conception en fonction du risque, analyse de l'incertitude, probabilité de non-conformité. / In this study, a probabilistic design method for the design of wastewater treatment plants (WWTP) that enables the quantification of the degree of compliance to the effluent standards in terms of probability has been proposed. The developed design method is a model-based approach in which relevant sources of uncertainty are expressed in terms of probability distribution functions and their combined effect on the distribution of the effluent quality is quantified by Monte Carlo simulation. To do so, a set of steady-state designs with different levels of safety is first generated using a design guideline and then the corresponding probability of non-compliance (PONC) to the effluent standards is calculated using dynamic simulations under different realizations of influent time series and different values for the WWTP model parameters. To generate different realizations of the influent time series, a software tool was developed for synthetic generation of influent time series data considering the local climate conditions as well as basic characteristics of the connected sewershed. Moreover, different realizations of WWTP model parameters are generated by sampling from the probability distribution functions that are assigned to uncertain model parameters. The combined effect of influent variability and model uncertainty on the effluent distributions is calculated by running a certain number of Monte Carlo simulation runs until convergence of the effluent distribution is achieved. Once convergence is reached for the effluent distribution, the PONC for a design alternative can be calculated for a certain effluent standard. The probabilistic design method can help designers avoid the application of conservative safety factors that could result in over-or under-sizing of WWTPs. Moreover, calculating the probability of non-compliance as a quantitative criterion can help designers and decision makers make risk-informed decisions on the best treatment configuration, sizing, and plant operation during the design or upgrading of WWTPs. Keywords: Wastewater treatment plant, design under uncertainty, risk-informed design, uncertainty analysis, probability of non-compliance.
3

Towards innovation-stimulating nutrient regulations : a global perspective with implications for the USA

Boisvert, Christophe 05 August 2024 (has links)
L'objectif du présent travail de maîtrise est de montrer l'effet de diverses approches de réglementation internationale sur la conception des stations d'épuration, la qualité des effluents, la conformité aux permis et les impacts sur les eaux réceptrices par le biais d'une étude de cas de modélisation réaliste. Les objectifs concrets de cette étude étaient les suivants : - Étudier l'équivalence des normes relatives aux effluents en termes de limites, d'évaluation de la conformité et d'impacts sur la qualité de l'eau. - Identifier les structures de permis efficaces en mettant l'accent sur les propriétés des permis qui pourraient contribuer à stimuler ou à inhiber l'innovation. - Développer une méthodologie permettant de comparer des permis d'eaux usées entre eux. La méthodologie de Jacobsen & Warn (1999) a été adaptée pour être utilisée avec des données de l'effluent d'une StaRRE de 78000 m$^3$/j situé en Virginie (VA) pour lequel une année complète de données était disponible. Les simulations ont été réalisées à l'aide du simulateur de traitement des eaux usées WEST (DHI, Danemark) et du modèle ASM2d. Cinq structures de permis provenant de Chine (classe 1B), des États-Unis (Nansemond + Norfolk, VA), du Canada (Québec) et des Pays-Bas ont été comparées pour un StaRRE faisant la pré-dénitrification conçu selon Metcalf & Eddy. Les permis ont été évalués en fonction de la différence de capacité de conception requise pour être conforme aux permis ainsi que de la protection de l'environnement qu'ils assurent. À cette fin, une rivière inspirée de la rivière James en Virginie a été simulée à l'aide du modèle River Water Quality Number 1. Les résultats suggèrent que la procédure de conception utilisée de Metcalf & Eddy est beaucoup plus conservateur pour l'élimination de l'azote et DBO$_5$ que pour les MeS. L'évaluation de l'impact environnemental de la décharge a montré que les pics d'OD apparaissent surtout pendant l'été tandis que les pics de NH₄ sont observés principalement pendant l'hiver. / The objective of this research project was to showcase the effect of various international regulation approaches on treatment plant design, effluent quality, permit compliance and receiving water impacts through a realistic modelling case study. The concrete objectives of this study to help advise on appropriate regulation structures were the following: - Investigating the equivalence of effluent standards in terms of limits, compliance assessment and water quality impact under variable conditions: - Identifying effective permit structures with a focus on the properties of permits that could help stimulate or inhibit innovation. - Develop a methodology that allows comparing permit structures one to another. Jacobsen and Warn (1999) studied a WRRF operating under steady state conditions to evaluate how the true effluent quality and treatment performance to be pursued is different for different permit structures. In this MSc study, their methodology was thus adapted for use with effluent quality data generated by dynamic simulations with an ASM2d WRRF model. The latter was based on a 20 MGD nitrogen-removing WRRF located in Virginia (VA) for which a full year of data was available. The simulations were conducted using the WEST wastewater treatment simulator (DHI, Denmark). Five permit structures from China (class 1B), USA (Nansemond, VA), USA (Norfolk, VA), Canada (Québec) and the Netherlands were compared for a WRRF based on Metcalf & Eddy design rules for a predenitrifying plant. The permits were evaluated in terms of the difference in design capacity that is required to achieve compliance with the regulations as well as the environmental protection they achieve. To that end, a river inspired by the James River in Virginia was simulated using IWA's RWQM1. The results suggest that the used Metcalf and Eddy design procedure is much more conservative for nitrogen and BOD$_5$ removal than for TSS. Take into account that the settler model utilized was not primarily constructed to precisely forecast the concentration of solids in the effluent, but to predict the concentration of sludge underflow. Hence, while the model can give significant insights into the system's performance concerning nitrogen and BOD$_5$ removal, its reliability may falter when predicting the efficiency of TSS removal in the effluent. Moreover, the environmental impact assessment of the discharge revealed that peaks of dissolved oxygen (DO) are predominantly seen in the summer, while ammonium (NH$_4$) peaks are mainly noticeable during the winter.
4

Comportement et caractérisation des boues d'un système de traitement des eaux usées par étangs aérés augmentés

Ridyard, Gabrielle 10 February 2024 (has links)
Le traitement des eaux usées par étangs aérés facultatifs est la méthode de traitement la plus répandue au Québec. Depuis l’adoption du ROMAEU (Règlement sur les ouvrages municipaux d’assainissement des eaux usées), plusieurs municipalités doivent faire une mise à niveau de leur station de traitement pour se conformer aux nouvelles normes de rejet, soit une concentration à l’effluent en MeS de 25 mg/L ainsi qu’une concentration en DBO5C de 25 mg/L. De plus, plusieurs stations ont, à ce jour, atteint leur vie utile et/ou leurs charges hydraulique ou organique sont dépassées. Ainsi, pour augmenter la capacité des étangs, quelques solutions ont été développées, dont le système KAMAKMC conçu par la compagnie Bionest, qui consiste en deux réacteurs à milieu fixe insérés dans un étang entre trois zones de décantation. Peu de données sont actuellement disponibles pour assurer une compréhension approfondie de ce procédé et de ses sous-systèmes. La présente étude consiste donc en l’analyse du comportement des boues au sein de cette nouvelle filière de traitement, principalement dans les zones de décantation. L’étude a été réalisée sur un système KAMAKMC installé dans le premier tiers de l’étang aéré de Grandes-Piles, en Mauricie. Le suivi de l’accumulation de boues a été effectué de mai 2016 à mai 2017 inclusivement, à raison d’une fois par mois. Les mesures ont été prises à l’aide d’une jauge à boues à différents points dans les zones de clarification. À titre de comparaison, des mesures avec un sonar ont été effectuées 3 fois durant la période du suivi (avril et octobre 2016 ainsi qu’en mai 2017). En parallèle aux mesures de hauteurs de boues, un échantillonnage a été effectué pour faire certaines analyses, dont les solides totaux (ST) et les solides totaux volatils (STV). De plus, une mesure de gaz in situ ainsi qu’en laboratoire ont été réalisées pendant la période estivale permettant de mieux caractériser la digestion anaérobie survenant dans ces zones de décantation. La température de l’eau durant la période de suivi a varié entre approximativement 2 °C et 22°C. Les taux d’accumulation trouvés pour Cl2 et Cl3 sont respectivement de 0,05m3an-1hab-1 et de 0,06m3an-1hab-1 . Par contre, la première zone de décantation possède un taux d’accumulation de boues annuel de 0. Cela suggère que l’aération fournie dans Cl1 limite l’accumulation de boues à 0,6m et que les solides primaires se déplacent vers Cl2 et Cl3. À partir du ratio STV/ST, il a été possible de remarquer qu’en température froide, le ratio était plus élevé dans les zones de décantation, tandis qu’en température chaude ce ratio était diminué. Pour la récolte de gaz in situ, des valeurs de 18 LCH4m-2d -1 et 4 LCH4m-2d -1 ont été trouvées dans ces deux zones et ils étaient composés de 62,8% de méthane en moyenne et 1,4% de CO2. Le peu de gaz carbonique est probablement attribuable à une solubilisation du gaz dans l’eau sous-jacente au montage de récolte de gaz. / In Quebec, wastewaters are mostly treated with aerated facultative lagoons. Since the adoption of the Regulation respecting municipal wastewater treatment works, many municipalities need to upgrade and improve their wastewater treatment station to comply with the new requirements, which are a concentration of suspended solids (SS) less than or equal to 25 mg/L and a concentration of the 5-day carbonaceous biochemical oxygen demand (CBOD5) less than or equal to 25 mg/L. Moreover, many stations have arrived at the end of their operating life expectancy and other stations have even exceeded their organic loads or flowrate loads. One solution that would help these municipalities would be to improve these stations with the new KAMAKMC technology developed by Bionest. This new technology incorporates two reactors containing BIONEST® inert media placed directly in a lagoon, between three clarification zones. At this time, there is a lack of technical data to ensure a good understanding of the KAMAKMC system. The aim of the present study is to characterize sludge accumulations in this new technology, especially in the clarification zones. Tests were conducted with a KAMAKMC system installed in the first third of an aerated lagoon belonging to the municipality of Grandes-Piles, in province of Québec. Between May 2016 and May 2017, measurements of sludge accumulations are taken monthly with a sludge judge in the clarification zones. To compare these measurements, sonar testing is taken 3 times during the year (April and October 2016 and May 2017). Sludge samples are taken during the year to measure total suspended solids (TSS) and volatile suspended solids (VSS). Moreover, gas sampling equipment sits over the lagoon to retrieve samples during the summer months of 2016, to allow a better characterization of anaerobic digestion in the zones. Water temperature during this follow up was between 2°C and 22°C. The sludge accumulation rate in the second and the third clarification zones were 0,05m3y -1hab-1 et de 0,06m3y -1hab-1 . In fact, the first clarification zone had a sludge accumulation rate of 0. This indicates that aeration in the first zone was high, restraining the sludge accumulation to a value of 0,6m and that primary solids were probably displaced in the next two clarification zone due to excessive aeration. The VSS/TSS ratio indicates that in cold temperature, the ratio was constant in every zone, while during the summer months a lower ratio was observed. Values of 18 LCH4m-2d -1 and 4 LCH4m2d -1 in Cl2 and Cl3 were found with the gas collector on the lagoon. Average methane concentrations in the gas collector were 62,8% and 1,4% of CO2. The low percentage of CO2 might be caused by the gas solubilization in the water.
5

Analyse environnementale et économique du cycle de vie d'un système d'épuration des eaux usées

Godin, David 18 April 2018 (has links)
Tableau d’honneur de la Faculté des études supérieures et postdoctorales, 2012-2013. / Dans le cadre de ce mémoire, les méthodologies de l’analyse de cycle de vie (ACV) et de l’analyse du cycle de coûts (ACC) sont appliquées à un système d’épuration des eaux usées municipales (STEP) afin de réaliser une évaluation intégrée du profil environnemental et économique du système. Suite à la revue de la littérature des ACVs portant sur des STEPs, des limitations ont été décelées en ce qui a trait à la définition de la fonction du système lors de la première étape de la réalisation de l’ACV. Les limitations dénotées ont mené au développement d’une méthodologie reposant sur le concept de bénéfice environnemental net (BEN) afin d’y pallier. La mise en application du concept de BEN requiert de réaliser des ACVs afin d’évaluer les impacts environnementaux potentiels évités et induits par l’épuration des eaux. Les impacts évités correspondent alors à la différence d’impacts potentiels entre un scénario hypothétique de rejet des eaux usées brutes et un scénario de rejet des eaux usées épurées par la STEP. Les impacts induits correspondent aux impacts générés par le cycle de vie du système d’épuration. Il est à noter que la présentation du concept de BEN ainsi que son application à une l’étude de cas font l’objet d’une publication (Godin et coll., 2012). Les méthodologies du BEN et de l’ACC sont appliquées à l’étude de cas d’un système d’épuration constitué d’étangs aérés facultatifs. Des inventaires des charges des polluants de l’affluent et de l’effluent de la STEP sont compilés afin d’évaluer les impacts potentiels évités en considérant les charges en matières organiques, en nutriments et en métaux lourds ainsi qu’en estimant les émissions potentielles de gaz à effet de serre des rejets directs de matière organique et d’azote au milieu récepteur. Les inventaires de caractérisation des impacts du cycle de vie du système incluent la phase de construction, l’opération ainsi que l’évaluation des impacts induits par une disposition des boues par épandage sur sol agricole et sur sol forestier. L’ACVI réalisée en ayant recours à la méthode ReCiPe et en mettant de l’avant le concept de BEN permet de constater le compromis environnemental fourni par le système d’épuration. L’évaluation comparée de l’ACC et de l’ACV du cycle de vie du système permet d’évaluer la contribution relative des différents éléments du cycle de vie sous les aspects environnementaux et économiques. La comparaison des variantes de disposition des boues permet, quant à elle, de comparer les effets sur les catégories d’impacts potentiels liées à la toxicité du choix du milieu récepteur des boues. L’application de la méthodologie du BEN lors de la réalisation d’ACV portant sur des STEPs permet de définir plus clairement la fonction principale de la STEP et permet d’éviter de considérer la STEP comme une source majeure de pollution. Elle fait de plus ressortir le manque de suivi des eaux usées en ce qui a trait à l’affluent ainsi qu’aux micropolluants. / Life cycle assessment (LCA) and life cycle costing (LCC) methodologies are applied to a municipal wastewater treatment plant (WWTP) in order to conduct an integrated environmental and economic assessment of the system. A Literature review showed that the system function definition has received little attention despite its great importance in past LCA studies applied to wastewater treatment plants (WWTPs). This has led to some limitations in the interpretation of LCA results. A new methodology to perform LCA on WWTPs is proposed to avoid those limitations. It is based on net environmental benefit (NEB) evaluation and requires assessing the potential impact of releasing wastewater without and with treatment besides assessing the impact of the WWTP’s life cycle. Interested readers can find a presentation of the NEB methodology and its application to a case study of a small municipal WWTP consisting of facultative aerated lagoons in Godin et al., (2012). This thesis presents the life cycle inventories (LCI) conducted to perform the LCAs required to estimate the NEB and also shows the inventory and results of the LCC performed on the case study. LCIs include wastewater characterization (i.e. organic matter, phosphorus, nitrogen and heavy metals load), potential greenhouse gas emissions, WWTP construction and operation inventories including sludge removal and disposal. Life cycle impact assessment (LCIA) was conducted using the ReCiPe impact assessment method. LCIA and LCC results allow comparing the relative contribution to environmental potential impacts and economic cost of the life cycle steps of the WWTP. The NEB allows showing the environmental trade-offs between avoided impact due to wastewater treatment and induced impact by the WWTP’s life cycle.
6

Simulations et stratégies de contrôle applicables à la gestion de la vidange du réservoir de rétention du site St-Sacrement du réseau sanitaire de la ville de Québec

Simoneau-Drolet, Daniel 11 April 2018 (has links)
Ce mémoire présente le développement d'un simulateur permettant d'étudier différentes stratégies applicables au contrôle de la vidange d'un réservoir de rétention du réseau sanitaire de l'est de la ville de Québec soit celui du site St-Sacrement. Dans un premier temps, le contexte du projet est présenté afin de bien comprendre les modèles qui sont proposés pour constituer le simulateur. Les modèles présentés, à prime abord, sont ceux par défaut, c'est à dire, disponibles avant la mise en service des installations. Cependant, les conditions hydrauliques de cette station de contrôle ne permettent pas de satisfaire toutes les hypothèses des modèles par défaut de telle sorte qu'une étape de calibration a été nécessaire. Suite à la réalisation de tests expérimentaux, différents modèles ont alors été calibrés afin d'augmenter la précision du simulateur. Ceci a permis de construire plusieurs simulateurs en fonction des modèles présentés (par défaut et expérimentaux). Des données expérimentales recueillies lors de la vidange contrôlée du 17 juillet 2005 ont permis de sélectionner le meilleur simulateur. Il s'est avéré que les modèles par défaut permettent de représenter le système avec précision sous réserve d'utiliser un bon délai d'écoulement entre le réservoir et la chambre de contrôle. Par ailleurs, des phénomènes en apparence complexes ont été modélisés avec des modèles relativement simples ce qui a permis d'augmenter du même coup la stabilité du simulateur. Le simulateur choisi a alors été utilisé pour tester et comparer différentes stratégies de contrôle pour la vidange du réservoir. Celui-ci a par ailleurs été modifié quelque peu afin de connaître la performance des différentes approches de contrôle présentées pour un système comportant des contraintes encore plus sévères. Les résultats montrent que les approches de contrôle plus avancées basées sur des modèles internes offrent de meilleures performances qu'un contrôleur PID mais qu'ils ne se démarquent significativement que pour les simulations utilisant des contraintes plus sévères. / This thesis presents the development of a Simulator to study various strategies applicable to control the emptying of a retention reservoir located at the St-Sacrement site, which is part of Québec City's Eastern wastewater collection network. The context of the project is first presented to fully understand the models proposed to build the Simulator. The models presented at first are default models, i.e. available before the commissioning of the facilities. However, because the hydraulic conditions of this control station could not satisfy ail the hypotheses related to the default models, some calibration was required. Following experimental tests, various models have been calibrated to increase the accuracy of the simulator. Several simulators were then built based on the models presented (default and experimental). The experimental data collected during the controlled emptying of the reservoir on July 17, 2005 was used to select the best simulator. It was found that default models can represent the network accurately provided that the flow is delayed between the basin and the control chamber. Also, some phenomena which seemed complex at first glance were simulated with relatively simple models, thus increasing the stability of the simulator. The selected simulator was then used to test and compare various control strategies for the emptying of the reservoir. The latter was later modified to assess the performance of the various control approaches for a System that included even more restrictive constraints. Results show that the more advanced control approaches, based on internal models, perform better than a PID controller. However, they stand out significantly only in simulations using more restrictive constraints.
7

Gestion intégrée des eaux usées urbaines : caractérisation et modélisation du comportement des polluants dans un bassin de rétention en réseau unitaire

Maruejouls, Thibaud 19 April 2018 (has links)
Si les débordements de réseaux unitaires sont reconnues comme étant un facteur important de l'impact environnemental du traitement des eaux usées urbaines, l'efficacité de l'implantation de bassins de rétention (BR) comme solution n'en demeure pas moins un questionnement. En effet, de plus en plus d'études tendent à prouver que l'impact de la vidange des BR sur l'efficacité de traitement d'une usine, et donc l'impact sur l'environnement, peut être négatif. L'interdisciplinarité et l'échelle géographique et temporelle de la problématique rendent l'appréhension de la problématique difficile par la seule mesure "in situ". L'intégration de plusieurs modèles du système urbain d'eaux usées se révèle être un outil puissant dans ce contexte. La simulation de différents scénarios amène à mieux anticiper les problèmes liés à la gestion des eaux usées, en temps de pluie comme en temps sec. Par conséquent, les coûts économiques et écologiques associés soit à la mise en place de nouvelles infrastructures, soit à la prise de décision concernant les stratégies de gestion du système, peuvent être optimisés. Il devient ainsi nécessaire de produire des modèles performants décrivant la qualité des eaux tout au long de leur cheminement. Les données sur le comportement des polluants dans les bassin de rétention sont peu nombreuses et la caractérisation des eaux retournées à l'usine de traitement est rarement étudiée. Par conséquent, si les connaissances des phénomènes en jeu sont souvent supposées, leur observation reste assez rare. Une partie importante du projet a donc été consacrée à la réalisation d'une campagne d'échantillonnage. Ce type d'échantillonnage s'est révélé être un exercice complexe et très contraignant en raison de l'imprévisibilité des événements orageux. L'objectif de cette campagne était de récolter des données en entrée et en sortie de bassin de rétention, principalement en ce qui concerne la matière en suspension, la demande chimique en oxygène et la distribution des vitesses de chute. Les résultats ont montré des dynamiques typiques de vidange révélant une forme en "U" des concentrations en polluants. Cette forme souligne trois phases appelées "initiale, milieu et finale" où chacune est caractérisée par une fourchette de concentrations et une distribution de vitesses de chute de particule qui lui est propre. De manière plus générale, il a été observé que plus les concentrations en MeS augmentent, plus la distribution des vitesses de chute est "lourde". Ces données couplées à des mesures en temps sec dans le collecteur et dans un bassin de décantation ont permis de comprendre les phénomènes en jeu, les interactions possibles entre les systèmes, et d'établir une structure solide pour le modèle. La littérature scientifique contient un grand nombre d'études de modélisation de la qualité de l'eau concernant les procédés de traitement. Cependant, elle est moins riche oncernant la description de la qualité des eaux en réseau et assez pauvre concernant la description de la qualité des eaux stockées en réseau ou en bassin de rétention. Les quelques modèles de BR existants décrivent assez simplement la décantation et la resuspension, qui sont pourtant les phénomènes dominant de ces systèmes. Ces modèles ont rarement été validés avec des données réelles car ces phénomènes sont difficiles à observer et à quantifier. Le projet visait donc à développer un modèle de bassin de rétention décrivant le comportement de la matière en suspension et de la demande chimique en oxygène à l'effluent d'un bassin de rétention (retour des eaux à l'usine) de sorte qu'il soit compatible avec les modèles de boue activées de type ASM de VInternational Water Association. La description des phénomènes de décantation et de resuspension est basée sur un fractionnement en classes de particules ayant différentes vitesses de chute. Ce fractionnement est directement issu de mesures de terrain réalisées en vue d'observer la variation de la distribution des vitesse de chute. Les effets d'un puits de pompage sur la sédimentation et la resuspension sont aussi décrits. Deux événements récoltés ont servi à la calibration du modèle et un autre a été utilisé pour sa validation. Cette étape est d'importance car elle n'a jamais été réalisée sur un modèle de BR. L'objectif final du modèle était qu'il soit intégré dans un système plus global (réseau - usine - rivière). Différents scénarios de gestion des vidanges de bassins de rétention ont mis en évidence les interactions entre les différents sous-systèmes en termes de masse de MeS et de masse de classes de particules. En effet, l'étude de l'évolution de la distribution des vitesses de chute des particules le long de la chaine de l'eau peut être une information utile pour anticiper les problèmes au traitement secondaire. Par exemple, une plus grande fraction de particules ayant une forte vitesse de chute peut engendrer : 1) une augmentation du temps d'hydrolyse des particules dans un système par boues activée ; ou 2) un plus grand risque de colmatage des biofiltres. Une meilleure compréhension de ces interactions peut permettre la mise en place de règles d'opération et de contrôle plus efficaces pour diminuer l'impact des rejets d'eaux usées sur l'environnement.

Page generated in 0.1259 seconds