Spelling suggestions: "subject:"ecocardiografia bidimensional"" "subject:"ecocardiografia idimensional""
1 |
Avaliação miocárdica por speckle tracking bidimensional em coelhos sob diferentes modalidades ventilatórias. /Marinho, Fabrício Andrade. January 2017 (has links)
Orientador: Aparecido Antonio Camacho / Resumo: O objetivo do presente estudo foi investigar a função miocárdica pela técnica de ecocardiografia bidimensional speckle tracking (2D STE) em pacientes submetidos à procedimentos anestésico prolongado, com a intenção de se detectar possível disfunção sistólica. Inicialmente para se determinar o intervalo normal da função sistólica na espécie, foram utilizados 31 coelhos da raça Nova Zelândia, adultos, hígidos, machos, com peso médio de 4,0 ± 0,53 kg, nos quais foram obtidos os índices sistólicos radiais como, velocidade rotacional e radial, deslocamento rotacional e radial, strain radial e strain rate radial. Posteriormente, para investigação da função sistólica sob diferentes modalidades ventilatórias, 32 coelhos foram distribuídos, aleatoriamente, em quatro grupos de modalidades ventilatórias diferentes constituídos de 8 animais cada, denominados grupo ventilação ciclada à pressão (GP), grupo ventilação ciclada à pressão associada à PEEP (GPP), grupo ventilação mandatória intermitente sincronizada (GM) e grupo ventilação espontânea (GE). Em todos os grupos, os parâmetros foram mensurados 40 minutos após a indução anestésica (M0) e reavaliados a cada vinte minutos, durante duas horas ininterruptas (M1, M2, M3 e M4). Portanto, o resultado demonstrados na presente investigação cientifica revelam que nenhuma modalidade ventilatória estudada proporcionou um quadro de disfunção sistólica a luz da técnica 2D STE quando foram comparados em cada momento de avaliação anestésica. / Abstract: The aim of this thesis was to investigate the cardiac function of patients undergoing prolonged anesthesia with the use of a two-dimensional speckle tracking (2D STE) technique to detect systolic dysfunction in order to maintain safety during anesthetic procedure. The study was carried out in healthy rabbits because this species is widely used as a model of experimentation for both humans and other animal species. Initially, the normal range of left ventricular radial systolic function was measured, for this purpose, 31 healthy male adults New Zealand rabbits were used, with average weight of 4.0 ± 0.53 kg, from a specialized producer; radial systolic indices were obtained, such as rotational and radial speed, rotational and radial displacement, radial strain and strain rate. Subsequently, 32 rabbits were randomly assigned to four groups of different ventilatory modalities consisting of 8 animals each, referred to as pressure-cycling ventilation group (GP), pressure-cycling ventilatory group associated with PEEP (GPP), synchronized intermittent mandatory ventilation group (GM) and spontaneous ventilation group (GE). In all groups, the parameters were measured 40 minutes after anesthetic induction (M0) and reevaluated every twenty minutes, for two uninterrupted hours (M1, M2, M3 and M4). Therefore, the results demonstrated in the present scientific investigation reveal that no studied ventilatory modality provided a picture of systolic dysfunction in light of the 2D STE techni... (Complete abstract click electronic access below) / Doutor
|
2 |
Estudo comparativo da mensuração de ventrículo esquerdo por meio de ecocardiografia nos modos M e bidimensional, nos cortes transversal e longitudinal em cães adultos normais da raça Pastor Alemão / Comparative study of left ventricular measurement by bidimensional and M mode echocardiography performed in short-axis and long-axis in adult normal German ShepherdsOliveira, Valéria Marinho Costa de 18 December 2009 (has links)
A avaliação do ventrículo esquerdo (VE) é uma das principais contribuições da ecocardiografia no estudo da função cardíaca e inclui a mensuração dos diâmetros da cavidade e espessura das paredes em diástole e sístole. O estudo por meio do modo M tem sido usado como padrão para a realização da mensuração e para o cálculo de índices sistólicos, mas o modo bidimensional também é utilizado para este fim. As medidas podem ser adquiridas a partir de dois planos de imagem: transversal e longitudinal. A definição de intervalos de confiança para valores normais de VE permite a identificação de remodelamento ventricular, concêntrico ou excêntrico, decorrente de doenças cardiovasculares ou sistêmicas. Assim sendo, o objetivo deste estudo foi comparar as medidas ecocardiográficas desta câmara obtidas pelos seguintes métodos: modo M em corte transversal, modo M em corte longitudinal, modo bidimensional em corte transversal e modo bidimensional em corte longitudinal. Adicionalmente, estudou-se o comportamento do efeito do peso e do sexo nos métodos mencionados. Foram selecionados 40 cães adultos da raça Pastor Alemão sem alterações cardiovasculares. A realização do ecocardiograma de cada animal inclui os quatro métodos descritos acima, de acordo com o recomendado pela literatura. Foram pesquisados os efeitos do corte e do método, bem como a influência do peso e do sexo, sobre cada medida estudada, linear ou derivada. O peso apresentou correlação com todas as medidas lineares de VE em pelo menos um dos métodos, mas não com fração de encurtamento (FE) e fração de ejeção (FEj). Utilizando-se a análise univariada, verificou-se que machos apresentaram todas as medidas estudadas significativamente maiores que fêmeas em pelo menos um dos métodos, exceto FE e FEj, cujos valores não foram diferentes entre os sexos. Observou-se efeito isolado do corte apenas sobre diâmetro diastólico final do ventrículo esquerdo (DdFVE), com medidas maiores obtidas no corte transversal, e mudança de comportamento do sexo nos cortes com influência significativa do peso sobre septo interventricular em diástole (SIVd). Houve efeito isolado do modo sobre os índices de função sistólica FE e FEj, com valores maiores fornecidos pelo modo M. O peso teve efeito isolado positivo sobre parede livre de ventrículo esquerdo em diástole (PLVEd), exceto no modo M em corte transversal e (diâmetro sistólico final de ventrículo esquerdo (DsFVE). O sexo, retirada a influência do peso, teve efeito isolado apenas sobre DdFVE, com machos apresentando valores significativamente maiores que fêmeas em ambos os cortes no modo bidimensional. Os resultados Os resultados mostram que há risco de erro de interpretação quando valores normais de referência, gerados a partir de determinado método, são utilizados para a avaliação de um paciente examinado por técnica de mensuração diversa, especialmente quando se obtém resultados nos limites superior ou inferior de normalidade. / Left ventricle (LV) evaluation is one of the most important contributions of echocardiography in the assessment of cardiac function. It includes measurements of internal diameter and wall thickness at end-diastole and end-sistole of this chamber. M Mode echocardiography has been widely used for measuring linear dimensions and quantifying systolic function, but bidimensional mode is also used with the same purpose. The LV measurement can be derived from transverse or longitudinal images of the heart. The establishment of normal confidence intervals of LV dimensions allows identification of concentric or excentric ventricular remodeling process secondary to cardiovascular and systemic diseases. The aim of this study was to compare LV measurements obtained from four methods: M mode in short-axis, M mode in long-axis, bidimensional mode in short-axis and bidimensional mode in long-axis view of the heart. In addition the effect of weight and gender over measures was studied in the methods mentioned above. Forty adult German Shepherds without cardiovascular diseases were selected. The echocardiogram of each animal included the four described methods, according previous referenced recommendations. The effects of axis and mode as well as weight and gender were studied for each linear or derived LV measure. Weight correlated with all linear LV measures at least in one method, but not with ejection fraction (EF) and shortening fraction (SF). All LV measures of males were greater than those of females at least in one method, except for EF and SF, which did not differ between sexes. Isolated effect of the axis was observed only for LV end diastolic diameter (LVEDD), with greater values obtained from short-axis views. The combined effect of axis, gender and weight was identified in interventricular septal end diastolic thickness. There was isolated effect of mode over EF and SF, with greater measures derived from bidimensional mode methods. Weight had isolated significant positive effect over LV enddiastole posterior wall thickness in all methods, except from M mode performed in short axis, and LV end-sistolic diameter. Gender had isolated effect only over LVEDD, males showing greater values than females in bidimensional mode in short and long axis. Professionals should be aware of the possibility of erroneous interpretation when using data obtained by a different method of that used in the patient exam as reference, mainly for the values situated in inferior and superior limits of confidence intervals.
|
3 |
Estudo comparativo da mensuração de ventrículo esquerdo por meio de ecocardiografia nos modos M e bidimensional, nos cortes transversal e longitudinal em cães adultos normais da raça Pastor Alemão / Comparative study of left ventricular measurement by bidimensional and M mode echocardiography performed in short-axis and long-axis in adult normal German ShepherdsValéria Marinho Costa de Oliveira 18 December 2009 (has links)
A avaliação do ventrículo esquerdo (VE) é uma das principais contribuições da ecocardiografia no estudo da função cardíaca e inclui a mensuração dos diâmetros da cavidade e espessura das paredes em diástole e sístole. O estudo por meio do modo M tem sido usado como padrão para a realização da mensuração e para o cálculo de índices sistólicos, mas o modo bidimensional também é utilizado para este fim. As medidas podem ser adquiridas a partir de dois planos de imagem: transversal e longitudinal. A definição de intervalos de confiança para valores normais de VE permite a identificação de remodelamento ventricular, concêntrico ou excêntrico, decorrente de doenças cardiovasculares ou sistêmicas. Assim sendo, o objetivo deste estudo foi comparar as medidas ecocardiográficas desta câmara obtidas pelos seguintes métodos: modo M em corte transversal, modo M em corte longitudinal, modo bidimensional em corte transversal e modo bidimensional em corte longitudinal. Adicionalmente, estudou-se o comportamento do efeito do peso e do sexo nos métodos mencionados. Foram selecionados 40 cães adultos da raça Pastor Alemão sem alterações cardiovasculares. A realização do ecocardiograma de cada animal inclui os quatro métodos descritos acima, de acordo com o recomendado pela literatura. Foram pesquisados os efeitos do corte e do método, bem como a influência do peso e do sexo, sobre cada medida estudada, linear ou derivada. O peso apresentou correlação com todas as medidas lineares de VE em pelo menos um dos métodos, mas não com fração de encurtamento (FE) e fração de ejeção (FEj). Utilizando-se a análise univariada, verificou-se que machos apresentaram todas as medidas estudadas significativamente maiores que fêmeas em pelo menos um dos métodos, exceto FE e FEj, cujos valores não foram diferentes entre os sexos. Observou-se efeito isolado do corte apenas sobre diâmetro diastólico final do ventrículo esquerdo (DdFVE), com medidas maiores obtidas no corte transversal, e mudança de comportamento do sexo nos cortes com influência significativa do peso sobre septo interventricular em diástole (SIVd). Houve efeito isolado do modo sobre os índices de função sistólica FE e FEj, com valores maiores fornecidos pelo modo M. O peso teve efeito isolado positivo sobre parede livre de ventrículo esquerdo em diástole (PLVEd), exceto no modo M em corte transversal e (diâmetro sistólico final de ventrículo esquerdo (DsFVE). O sexo, retirada a influência do peso, teve efeito isolado apenas sobre DdFVE, com machos apresentando valores significativamente maiores que fêmeas em ambos os cortes no modo bidimensional. Os resultados Os resultados mostram que há risco de erro de interpretação quando valores normais de referência, gerados a partir de determinado método, são utilizados para a avaliação de um paciente examinado por técnica de mensuração diversa, especialmente quando se obtém resultados nos limites superior ou inferior de normalidade. / Left ventricle (LV) evaluation is one of the most important contributions of echocardiography in the assessment of cardiac function. It includes measurements of internal diameter and wall thickness at end-diastole and end-sistole of this chamber. M Mode echocardiography has been widely used for measuring linear dimensions and quantifying systolic function, but bidimensional mode is also used with the same purpose. The LV measurement can be derived from transverse or longitudinal images of the heart. The establishment of normal confidence intervals of LV dimensions allows identification of concentric or excentric ventricular remodeling process secondary to cardiovascular and systemic diseases. The aim of this study was to compare LV measurements obtained from four methods: M mode in short-axis, M mode in long-axis, bidimensional mode in short-axis and bidimensional mode in long-axis view of the heart. In addition the effect of weight and gender over measures was studied in the methods mentioned above. Forty adult German Shepherds without cardiovascular diseases were selected. The echocardiogram of each animal included the four described methods, according previous referenced recommendations. The effects of axis and mode as well as weight and gender were studied for each linear or derived LV measure. Weight correlated with all linear LV measures at least in one method, but not with ejection fraction (EF) and shortening fraction (SF). All LV measures of males were greater than those of females at least in one method, except for EF and SF, which did not differ between sexes. Isolated effect of the axis was observed only for LV end diastolic diameter (LVEDD), with greater values obtained from short-axis views. The combined effect of axis, gender and weight was identified in interventricular septal end diastolic thickness. There was isolated effect of mode over EF and SF, with greater measures derived from bidimensional mode methods. Weight had isolated significant positive effect over LV enddiastole posterior wall thickness in all methods, except from M mode performed in short axis, and LV end-sistolic diameter. Gender had isolated effect only over LVEDD, males showing greater values than females in bidimensional mode in short and long axis. Professionals should be aware of the possibility of erroneous interpretation when using data obtained by a different method of that used in the patient exam as reference, mainly for the values situated in inferior and superior limits of confidence intervals.
|
4 |
Identificação de lesões coronárias graves por meio do strain bidimensional longitudinal do ventrículo esquerdo na síndrome coronariana aguda sem elevação do segmento ST / Severe coronary artery stenosis identification by two dimensional strain in non-ST- elevation acute coronary syndromeVilela, Andréa de Andrade 20 October 2014 (has links)
Estimativas nacionais e internacionais indicam que a síndrome coronariana aguda é uma das principais causas de internação hospitalar e óbito. A maioria desses pacientes tem diagnóstico de síndrome coronariana aguda sem supradesnivelamento do segmento ST (SCASSSST) e possui amplo espectro de gravidade, que varia de acordo com características clínicas e laboratoriais. A estratificação de risco é essencial para auxiliar na decisão clínica, discriminando quais pacientes se beneficiam de estratégias mais agressivas. Os escores TIMI e GRACE são os mais utilizados e com valor prognóstico estabelecido por estudos de coorte prospectiva. O strain longitudinal bidimensional (S2DL) permite a quantificação da deformidade miocárdica por meio do rastreamento de \"marcas acústicas\" naturais do músculo cardíaco pelo ultrassom, apresentando valores reduzidos na presença de isquemia miocárdica. O objetivo principal desse trabalho foi identificar, por meio do S2DL do ventrículo esquerdo, quais pacientes com SCASSSST apresentam estenose coronariana maior ou igual a 70%. Os objetivos secundários foram: 1) Identificar a porcentagem de pacientes categorizados como de baixo risco e moderado risco, segundo os escores TIMI e GRACE, que apresentaram estenose coronária maior ou igual a 70%; 2) Determinar um valor de corte do S2DL e número mínimo de segmentos adjacentes acometidos que se correlacionem com o território irrigado pela coronária comprometida (com estenose maior ou igual a 70%) nos pacientes portadores de SCASSSST. Total de 100 pacientes com Idade de 60±11,4, 62% do sexo masculino e predomínio de pacientes (p) de baixo e moderado risco cardiovascular (80% pelo escore TIMI e 99% pelo escore GRACE). Divididos em grupo A (34p) com estenose coronária < 70% e grupo B (66p) com estenose coronária >=70%. Os escores clínicos foram maiores no grupo B (TIMI 3,59±1,4; p=0,008 e GRACE 88,7±24,18; p=0,040). O strain longitudinal global (SLG) permitiu identificar os pacientes com estenose coronária >=70% (AUC=0,72, sensibilidade=50%, especificidade=90%, valor preditivo positivo= 75,1% e valor preditivo negativo=74,9%). No grupo B, 72,8% e 98,5% foram categorizados como de baixo e moderado risco pelos escores TIMI e GRACE, respectivamente. O strain longitudinal segmentar (SLS) permitiu identificar a coronária culpada pelo evento isquêmico, com valor de cut-off e número mínimo de segmentos estimados em: -14 e 4 segmentos para coronária descendente anterior, -16 e 3 segmentos para a coronária circunflexa e coronária direita. Concluímos que o SLG mostrou ser acurado em discriminar pacientes com estenose coronária grave, mesmo naqueles com escore de risco baixo e moderado pelos escores TIMI e GRACE. O SLS permite estimar a área de miocárdio isquêmico por meio do número de segmentos com deformidade alterada, e conhecer a coronária culpada mais provável. / National and international estimates indicate that acute coronary syndrome is one of the major causes of hospitalization and death. Most of these patients have a diagnosis of non-ST-elevation acute coronary syndrome (NSTE-ACS) and have wide spectrum of severity. Risk stratification is essential to assist in clinical decision. The TIMI and GRACE risk scores are the most used and the prognostic values were established by prospective cohort study. Myocardial strain by speckle tracking is a technique based on widely available two-dimensional grayscale echocardiography, enabling the accurate evaluation of global and regional myocardial function, and it is has been shown to be sensitive to abnormalities caused by ischemia. The main objective of this study was to identify, through global longitudinal strain, whose patients (p) with NSTE-ACS had >= 70 % coronary stenosis. The secondary objectives were: 1) Identify the percentage of p categorized as low or moderate risk according to the TIMI and GRACE risk scores , who showed coronary stenosis >= 70 % ; 2) Determine a cutoff value of regional strain and the minimum number of segments allowing the identification of the culprit coronary artery in p with NSTE-ACS. Hundred (p) with diagnosis NSTE-ACS were stratified according to TIMI and GRACE risk scores, and all p underwent coronary angiography. Global longitudinal strain (GLS) and territorial strain (TS) were calculated. Age 60 ± 11.4, 62% male. Majority were low and moderate cardiovascular risk (TIMI score by 80 % and 99 % by the GRACE score). They were divided into group A (34p) with coronary stenosis < 70 % and group B (66p) with coronary stenosis >= 70 %. Clinical scores were higher in group B (TIMI 3.59 ± 1.4, p = 0.008 and 88.7 ± GRACE 24.18, p = 0.040). SLG was accurate identifying p with coronary stenosis >= 70 % (AUC = 0.72, p=0.001, sensitivity = 50 %, specificity = 90 %, positive predictive value = 75.1 % and negative predictive value = 74.9 %). Group B were low and moderate cardiovascular risk 72.8 % by TIMI risk score and 98.5 % by GRACE risk scores. TS was able to identify the culprit coronary in an ischemic event with cutoff values and minimum number of damaged segments as follow: -14 and 4 segments for anterior descending coronary, -16 and 3 segments to the circumflex coronary and right coronary. SLG has proved accurate in discriminating patients with severe coronary stenosis, even in those with low and moderate risk by TIMI and GRACE risk scores. TS estimates the area of ischemic myocardium by the number of segments with abnormal deformity, and suggests the most likely culprit coronary.
|
5 |
Correlação entre medidas ecocardiográfica e invasiva da pressão diastólica final do ventrículo esquerdo em coronariopatas com fração de ejeção preservada / Correlation between echocardiographic and invasive measurements of left ventricular end-diastolic pressure in patients with coronary artery disease and preserved ejection fractionCalvilho Junior, Antonio Amador 19 April 2016 (has links)
A doença arterial coronária é importante e prevalente manifestação da aterosclerose. A avaliação da função diastólica pelos parâmetros mitrais obtidos com Doppler ecocardiográfico possui limitações nos coronariopatas com fração de ejeção do ventrículo esquerdo (FEVE) preservada. Nestes, a disfunção diastólica, independentemente da FEVE, associa-se a maior incidência de desfechos desfavoráveis. A elevação da pressão diastólica final (PD2) do ventrículo esquerdo (VE) é a principal consequência fisiológica da disfunção diastólica. A pesquisa por melhores formas de determinação da PD2 do VE estendeu-se às modernas técnicas ecocardiográficas de quantificação da mecânica cardíaca. O objetivo deste estudo é correlacionar as medidas de deformação miocárdica, obtidas pelo speckle-tracking ecocardiográfico bidimensional, com a medida invasiva da PD2 do VE em pacientes com insuficiência coronariana e FEVE preservada. Métodos: foram avaliados 81 coronariopatas (idade: 61 ±8 anos) com FEVE >50%, encaminhados para cineangiocoronariografia eletiva, 40 destes com PD2 elevada (>16 mm Hg). Todos os indivíduos foram submetidos à avaliação ecocardiográfica convencional imediatamente antes do cateterismo e subsequente avaliação offline, com ecocardiografia speckle tracking (EST) para obtenção de medidas sistólicas e diastólicas de strain e strain rate circunferenciais e longitudinais, e estudo rotacional do VE. Foram analisadas as variáveis diastólicas da EST, tanto de forma isolada, quanto combinada com a velocidade da onda E ao Doppler. Resultados: Comparativamente, os pacientes do grupo com PD2 do VE elevada (n=40) mostraram aumento do volume indexado do átrio esquerdo (22 ±6 mL vs 26 ±8,26 mL p=0,04), velocidade da onda E (65 ±15 cm/s vs 78 ±20 cm/s p=0,02), relação E/e\' médio (8,14 ±2,0 vs 11,54 ±2,7 p=0,03) e relação E/strain rate global circunferencial (SRGC) pico E (39 cm vs 46 cm p <0,01). Nos 81 pacientes a correlação de Spearman com a medida invasiva da PD2 do VE foi de 0,56 para a relação E/e\' (p=0,03) e de 0,43 para a relação E/ESRGC pico E (p<0,01). A área sob a curva ROC foi significativa em ambas, sendo 0,83 e 0,73 respectivamente (p<0,05). Conclusão: A relação E/SRGC pico E é capaz de identificar elevação da PD2 do VE em coronariopatas com FEVE preservada, com menor desempenho que a relação E/e\'. / Introduction: Coronary artery disease (CAD) is important and prevalent manifestation of atherosclerosis. The assessment of diastolic function by mitral Doppler echocardiographic parameters has limitations in patients with CAD and preserved left ventricular ejection fraction (LVEF). Diastolic dysfunction is associated with higher incidence of unfavorable outcomes in these patients, regardless of LVEF. The increase in left ventricle end-diastolic pressure (LVEDP) is the main physiological consequence of diastolic dysfunction. The search for better ways of determining the LVEDP extended to the quantitative evaluation of cardiac mechanics with the modern echocardiographic techniques. The aim of this study is to correlate the invasive mesures of LVEDP and myocardial deformation measurements obtained by the two-dimensional speckle-tracking echocardiography in patients with coronary artery disease and preserved LVEF. Methods: 81 CAD patients (age: 61 ± 8 years) with LVEF >50%, scheduled for elective coronary angiography were evaluated, 40 of these with high LVEDP (>16 mm Hg). All subjects underwent conventional echocardiography immediately before catheterization and subsequent offline assessment with speckletracking echocardiography (STE) to obtain systolic and diastolic values of circumferential and longitudinal strain and strain rate, and rotational LV study. Diastolic variables of EST were analyzed both isolated and combined with the speed of the transmitral Doppler E wave. Results: Patients in the group with the high LVEDP (n =40) showed increased left atrial volume index (22 ± 6 mL vs 26 ± 8.26 mL p =0.04), E wave velocity (65 ± 15 cm/s vs 78 ±20 cm/s p = 0.02), E/e\' (average) ratio ( 8.14 ± 2.0 vs 11.54 ± 2.7 p = 0.03) and E/global circumferential strain rate (GCSR) peak E (39 cm vs 46 cm p <0.01). In 81 patients, Spearman\'s correlation with the invasive measurement of LVEDP was 0,56 (p =0.03) for the E/e\' ratio and 0.43 for the E/GCSR peak E (p <0.01). The area under the ROC curve was significant for both (p < 0.05): 0.83 and 0.73 respectively. Conclusion: The E/GCSR peak E ratio is able to identify elevated LVEDP in CAD patients with preserved LVEF, with less performance than the E/e\' ratio.
|
6 |
Correlação entre medidas ecocardiográfica e invasiva da pressão diastólica final do ventrículo esquerdo em coronariopatas com fração de ejeção preservada / Correlation between echocardiographic and invasive measurements of left ventricular end-diastolic pressure in patients with coronary artery disease and preserved ejection fractionAntonio Amador Calvilho Junior 19 April 2016 (has links)
A doença arterial coronária é importante e prevalente manifestação da aterosclerose. A avaliação da função diastólica pelos parâmetros mitrais obtidos com Doppler ecocardiográfico possui limitações nos coronariopatas com fração de ejeção do ventrículo esquerdo (FEVE) preservada. Nestes, a disfunção diastólica, independentemente da FEVE, associa-se a maior incidência de desfechos desfavoráveis. A elevação da pressão diastólica final (PD2) do ventrículo esquerdo (VE) é a principal consequência fisiológica da disfunção diastólica. A pesquisa por melhores formas de determinação da PD2 do VE estendeu-se às modernas técnicas ecocardiográficas de quantificação da mecânica cardíaca. O objetivo deste estudo é correlacionar as medidas de deformação miocárdica, obtidas pelo speckle-tracking ecocardiográfico bidimensional, com a medida invasiva da PD2 do VE em pacientes com insuficiência coronariana e FEVE preservada. Métodos: foram avaliados 81 coronariopatas (idade: 61 ±8 anos) com FEVE >50%, encaminhados para cineangiocoronariografia eletiva, 40 destes com PD2 elevada (>16 mm Hg). Todos os indivíduos foram submetidos à avaliação ecocardiográfica convencional imediatamente antes do cateterismo e subsequente avaliação offline, com ecocardiografia speckle tracking (EST) para obtenção de medidas sistólicas e diastólicas de strain e strain rate circunferenciais e longitudinais, e estudo rotacional do VE. Foram analisadas as variáveis diastólicas da EST, tanto de forma isolada, quanto combinada com a velocidade da onda E ao Doppler. Resultados: Comparativamente, os pacientes do grupo com PD2 do VE elevada (n=40) mostraram aumento do volume indexado do átrio esquerdo (22 ±6 mL vs 26 ±8,26 mL p=0,04), velocidade da onda E (65 ±15 cm/s vs 78 ±20 cm/s p=0,02), relação E/e\' médio (8,14 ±2,0 vs 11,54 ±2,7 p=0,03) e relação E/strain rate global circunferencial (SRGC) pico E (39 cm vs 46 cm p <0,01). Nos 81 pacientes a correlação de Spearman com a medida invasiva da PD2 do VE foi de 0,56 para a relação E/e\' (p=0,03) e de 0,43 para a relação E/ESRGC pico E (p<0,01). A área sob a curva ROC foi significativa em ambas, sendo 0,83 e 0,73 respectivamente (p<0,05). Conclusão: A relação E/SRGC pico E é capaz de identificar elevação da PD2 do VE em coronariopatas com FEVE preservada, com menor desempenho que a relação E/e\'. / Introduction: Coronary artery disease (CAD) is important and prevalent manifestation of atherosclerosis. The assessment of diastolic function by mitral Doppler echocardiographic parameters has limitations in patients with CAD and preserved left ventricular ejection fraction (LVEF). Diastolic dysfunction is associated with higher incidence of unfavorable outcomes in these patients, regardless of LVEF. The increase in left ventricle end-diastolic pressure (LVEDP) is the main physiological consequence of diastolic dysfunction. The search for better ways of determining the LVEDP extended to the quantitative evaluation of cardiac mechanics with the modern echocardiographic techniques. The aim of this study is to correlate the invasive mesures of LVEDP and myocardial deformation measurements obtained by the two-dimensional speckle-tracking echocardiography in patients with coronary artery disease and preserved LVEF. Methods: 81 CAD patients (age: 61 ± 8 years) with LVEF >50%, scheduled for elective coronary angiography were evaluated, 40 of these with high LVEDP (>16 mm Hg). All subjects underwent conventional echocardiography immediately before catheterization and subsequent offline assessment with speckletracking echocardiography (STE) to obtain systolic and diastolic values of circumferential and longitudinal strain and strain rate, and rotational LV study. Diastolic variables of EST were analyzed both isolated and combined with the speed of the transmitral Doppler E wave. Results: Patients in the group with the high LVEDP (n =40) showed increased left atrial volume index (22 ± 6 mL vs 26 ± 8.26 mL p =0.04), E wave velocity (65 ± 15 cm/s vs 78 ±20 cm/s p = 0.02), E/e\' (average) ratio ( 8.14 ± 2.0 vs 11.54 ± 2.7 p = 0.03) and E/global circumferential strain rate (GCSR) peak E (39 cm vs 46 cm p <0.01). In 81 patients, Spearman\'s correlation with the invasive measurement of LVEDP was 0,56 (p =0.03) for the E/e\' ratio and 0.43 for the E/GCSR peak E (p <0.01). The area under the ROC curve was significant for both (p < 0.05): 0.83 and 0.73 respectively. Conclusion: The E/GCSR peak E ratio is able to identify elevated LVEDP in CAD patients with preserved LVEF, with less performance than the E/e\' ratio.
|
7 |
Identificação de lesões coronárias graves por meio do strain bidimensional longitudinal do ventrículo esquerdo na síndrome coronariana aguda sem elevação do segmento ST / Severe coronary artery stenosis identification by two dimensional strain in non-ST- elevation acute coronary syndromeAndréa de Andrade Vilela 20 October 2014 (has links)
Estimativas nacionais e internacionais indicam que a síndrome coronariana aguda é uma das principais causas de internação hospitalar e óbito. A maioria desses pacientes tem diagnóstico de síndrome coronariana aguda sem supradesnivelamento do segmento ST (SCASSSST) e possui amplo espectro de gravidade, que varia de acordo com características clínicas e laboratoriais. A estratificação de risco é essencial para auxiliar na decisão clínica, discriminando quais pacientes se beneficiam de estratégias mais agressivas. Os escores TIMI e GRACE são os mais utilizados e com valor prognóstico estabelecido por estudos de coorte prospectiva. O strain longitudinal bidimensional (S2DL) permite a quantificação da deformidade miocárdica por meio do rastreamento de \"marcas acústicas\" naturais do músculo cardíaco pelo ultrassom, apresentando valores reduzidos na presença de isquemia miocárdica. O objetivo principal desse trabalho foi identificar, por meio do S2DL do ventrículo esquerdo, quais pacientes com SCASSSST apresentam estenose coronariana maior ou igual a 70%. Os objetivos secundários foram: 1) Identificar a porcentagem de pacientes categorizados como de baixo risco e moderado risco, segundo os escores TIMI e GRACE, que apresentaram estenose coronária maior ou igual a 70%; 2) Determinar um valor de corte do S2DL e número mínimo de segmentos adjacentes acometidos que se correlacionem com o território irrigado pela coronária comprometida (com estenose maior ou igual a 70%) nos pacientes portadores de SCASSSST. Total de 100 pacientes com Idade de 60±11,4, 62% do sexo masculino e predomínio de pacientes (p) de baixo e moderado risco cardiovascular (80% pelo escore TIMI e 99% pelo escore GRACE). Divididos em grupo A (34p) com estenose coronária < 70% e grupo B (66p) com estenose coronária >=70%. Os escores clínicos foram maiores no grupo B (TIMI 3,59±1,4; p=0,008 e GRACE 88,7±24,18; p=0,040). O strain longitudinal global (SLG) permitiu identificar os pacientes com estenose coronária >=70% (AUC=0,72, sensibilidade=50%, especificidade=90%, valor preditivo positivo= 75,1% e valor preditivo negativo=74,9%). No grupo B, 72,8% e 98,5% foram categorizados como de baixo e moderado risco pelos escores TIMI e GRACE, respectivamente. O strain longitudinal segmentar (SLS) permitiu identificar a coronária culpada pelo evento isquêmico, com valor de cut-off e número mínimo de segmentos estimados em: -14 e 4 segmentos para coronária descendente anterior, -16 e 3 segmentos para a coronária circunflexa e coronária direita. Concluímos que o SLG mostrou ser acurado em discriminar pacientes com estenose coronária grave, mesmo naqueles com escore de risco baixo e moderado pelos escores TIMI e GRACE. O SLS permite estimar a área de miocárdio isquêmico por meio do número de segmentos com deformidade alterada, e conhecer a coronária culpada mais provável. / National and international estimates indicate that acute coronary syndrome is one of the major causes of hospitalization and death. Most of these patients have a diagnosis of non-ST-elevation acute coronary syndrome (NSTE-ACS) and have wide spectrum of severity. Risk stratification is essential to assist in clinical decision. The TIMI and GRACE risk scores are the most used and the prognostic values were established by prospective cohort study. Myocardial strain by speckle tracking is a technique based on widely available two-dimensional grayscale echocardiography, enabling the accurate evaluation of global and regional myocardial function, and it is has been shown to be sensitive to abnormalities caused by ischemia. The main objective of this study was to identify, through global longitudinal strain, whose patients (p) with NSTE-ACS had >= 70 % coronary stenosis. The secondary objectives were: 1) Identify the percentage of p categorized as low or moderate risk according to the TIMI and GRACE risk scores , who showed coronary stenosis >= 70 % ; 2) Determine a cutoff value of regional strain and the minimum number of segments allowing the identification of the culprit coronary artery in p with NSTE-ACS. Hundred (p) with diagnosis NSTE-ACS were stratified according to TIMI and GRACE risk scores, and all p underwent coronary angiography. Global longitudinal strain (GLS) and territorial strain (TS) were calculated. Age 60 ± 11.4, 62% male. Majority were low and moderate cardiovascular risk (TIMI score by 80 % and 99 % by the GRACE score). They were divided into group A (34p) with coronary stenosis < 70 % and group B (66p) with coronary stenosis >= 70 %. Clinical scores were higher in group B (TIMI 3.59 ± 1.4, p = 0.008 and 88.7 ± GRACE 24.18, p = 0.040). SLG was accurate identifying p with coronary stenosis >= 70 % (AUC = 0.72, p=0.001, sensitivity = 50 %, specificity = 90 %, positive predictive value = 75.1 % and negative predictive value = 74.9 %). Group B were low and moderate cardiovascular risk 72.8 % by TIMI risk score and 98.5 % by GRACE risk scores. TS was able to identify the culprit coronary in an ischemic event with cutoff values and minimum number of damaged segments as follow: -14 and 4 segments for anterior descending coronary, -16 and 3 segments to the circumflex coronary and right coronary. SLG has proved accurate in discriminating patients with severe coronary stenosis, even in those with low and moderate risk by TIMI and GRACE risk scores. TS estimates the area of ischemic myocardium by the number of segments with abnormal deformity, and suggests the most likely culprit coronary.
|
Page generated in 0.0835 seconds