• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Correção do efeito Schlieren e integração de unidades de extração e pré-concentração em fase sólida em microssistemas de análise

Magalhães, Laiz de Oliveira 05 August 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2016-02-15T11:46:31Z No. of bitstreams: 1 2015_LaizOliveiraMagalhaes.pdf: 3662735 bytes, checksum: aa0ab1f8c6445e875927f84003af42c2 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-02-15T16:31:12Z (GMT) No. of bitstreams: 1 2015_LaizOliveiraMagalhaes.pdf: 3662735 bytes, checksum: aa0ab1f8c6445e875927f84003af42c2 (MD5) / Made available in DSpace on 2016-02-15T16:31:12Z (GMT). No. of bitstreams: 1 2015_LaizOliveiraMagalhaes.pdf: 3662735 bytes, checksum: aa0ab1f8c6445e875927f84003af42c2 (MD5) / Este trabalho descreve o desenvolvimento de microssistemas fluídicos de uretano-acrilato integrados com coluna empacotada para a extração em fase sólida com trocador aniônico e detecção fotométrica com correção do efeito Schlieren. Um diodo emissor de luz (LED) emitindo sequencialmente em diferentes comprimentos de onda (470, 530 e 625 nm) foi utilizado para adquirir o sinal referente apenas ao efeito Schlieren e outro sinal referente ao efeito e também ao analito, permitindo a correção pela subtração dos sinais. Foi demonstrado que o referido efeito é eliminado ou minimizado mesmo quando soluções de trabalho com elevadas diferenças de concentração são gerenciadas no interior do dispositivo, permitindo a determinação de íons NO2- em meios com elevada concentração de eletrólitos, Cr (VI) em meios com elevada acidez e Fe (II) em amostras de medicamentos com elevado teor de sacarose, propiciando, neste último caso, erros relativos menores que 10% por meio da comparação com o método de referência. Um dispositivo com microesferas de resina aniônica Dowex 1X8 foi construído empacotando-se manualmente o material sólido em um reservatório com dimensões de 25 × 2,0 × 1,0 mm, previamente ao procedimento de selagem. O microssistema proposto não apresentou entupimentos ou vazamentos na região da coluna e a sua aplicação à determinação de íons NO2- em águas superficiais do lago Paranoá (Brasília-DF) proporcionou um fator de pré-concentração de aproximadamente quatro vezes a partir de um volume de apenas 3,80 mL da solução da amostra, permitindo a detecção do analito na faixa de 0,05 a 0,20 mg L-1 com limite de detecção de 0,04 mg L-1 (0,01 mg L-1 N), o qual é cerca de 100 vezes inferior ao limite máximo estabelecido pela legislação brasileira (CONAMA 357). A repetibilidade para quatro injeções do padrão de 0,10 mg L-1 foi estimada em 5,35%. Adicionalmente, recuperações na faixa de 96 a 101% foram estimadas para o analito em todas as amostras avaliadas, demonstrando a possível aplicação do dispositivo para este tipo de análise a partir de um procedimento com baixo consumo de reagentes e pequena geração de resíduos. ______________________________________________________________________________________________ ABSTRACT / This work describes the development of urethane-acrylate fluidic microsystems integrated with packed column for solid phase extraction based on anionic exchanger and photometric detection with Schlieren effect correction. A lighting emitting diode (LED) that sequentially emits on different wavelengths (470, 530 e 625 nm) was used to acquire a signal referent to the schlieren effect only and other signal for the sum of the effect with the analyte response, providing the correction of the effect by subtraction of the two signals. It was demonstrated that the effect is eliminated or quite reduced even when working solutions with elevated differences on concentrations are managed inside the microfluidic devices, allowing the determination of NO2- in a medium with high electrolyte concentrations, Cr (VI) in solutions with high acidity and Fe (II) in solutions with great concentration of saccharose, allowing, in this last case, relative errors lower than 10% by the comparison with the reference method. A microfluidic device, containing micro-spheres of the anionic exchanger Dowex 1X8, was constructed by manually packing the solid phase on a photolithographed reservoir with dimensions of 25 × 2.0 × 1.0 mm prior the sealing of the structures. The proposed microsystem presents no clogging or leaking in the region of the packed column and its application for the determination of NO2- in surface waters of Paranoá Lake (Brasília-DF) provided a pre-concentration factor of approximately four fold, using only 3.80 mL of sample solution, permitting the detection of analyte in the concentration range of 0.05 a 0.20 mg L-1 with a limit of detection of 0.04 mg L-1 (0.01 mg L-1 N), which is approximately 100 times lower than the maximum concentration permited by Brazilian regulations (CONAMA 357). The repetibility for four injections of the 0.10 mg L-1 standart was estimated in 5,35%. In addition, recoveries in the range of 96 to 101% were estimated for the analyzed samples, demonstrating the possible application of the proposed device for nitrite analysis using a procedure with low consumption of reagents and reduced generation of residues.
2

Determinação do teor de NaCl, Glicose e KCI em medicamentos injetáveis por fotometria usando exploração do efeito Schlieren em Sistemas FIA e PLS1 / Determination of NaCl, KCl and Glucose Content in Injectable Pharmaceuticals by Photometry Exploring the Schlieren Effect in FIA Systems and PLS1

Diniz, Paulo Henrique Gonçalves Dias 01 October 2010 (has links)
Made available in DSpace on 2015-05-14T13:21:52Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2728710 bytes, checksum: 6517b3a8e30d4a561eb90e4be9c69916 (MD5) Previous issue date: 2010-10-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study evaluated using the Schlieren effect in FIA systems as a new strategy to determine the amounts of sodium chloride, potassium chloride and glucose, each respectively in intravenous drugs. The proposed methodology was based on the difference between the refractive indices of sample zones and the carrier stream. With this perspective, photometric detection was used based on an LED and a phototransistor to investigate the different analytical profiles related to the Schlieren effect in low flow rate conditions. Adjustment studies of the parameters and flow settings (which were most suitable to exploit Schlieren profiles), were performed. The proposed methodology generates a large amount of chemical information and therefore requires the use of chemometric tools. Data evaluation was performed with the application of a partial least squares regression (PLS1), employing the standard solutions of each analyte to construct and validate the models. The models were then used to predict the content of each analyte in their real samples. The results demonstrated the predictive ability of the constructed PLS1 models, and the predicted concentration values were in agreement with the reference values, with 95% of confidence. The main advantages of using the Schlieren effect in the chemical analysis is that no reagent is employed, low volumes of samples are used and no expensive radiation detectors are used. / Neste trabalho foi avaliada a exploração do efeito Schlieren em sistemas FIA para a implementação de uma nova estratégia para determinar o teor de cloreto de sódio, cloreto de potássio e glicose em amostras de soro fisiológico, KCl injetável e soro glicosado, respectivamente. A metodologia proposta se baseia na diferença entre os índices de refração das zonas da amostra e do fluido carregador. Nesta perspectiva, foi empregada detecção fotométrica baseada em LED e fototransistor para investigar diferentes perfis analíticos associados ao efeito Schlieren em condições de baixa vazão. Estudos para ajuste dos parâmetros e configurações de fluxo mais adequados nos quais os perfis Schlieren podem ser explorados foram realizados. A metodologia proposta gera uma grande quantidade de informações químicas e, por isso, requer a utilização de ferramentas quimiométricas. A avaliação dos resultados foi realizada com a aplicação da regressão por mínimos quadrados parciais (PLS1), a qual empregou as soluções padrão de cada analito para construção e validação dos modelos. Em seguida, os modelos construídos foram utilizados para a previsão do teor de cada analito em suas respectivas amostras reais. Os resultados obtidos demonstraram a boa capacidade preditiva dos modelos PLS1 construídos, pois os valores das concentrações previstos pelos modelos foram concordantes com os valores de referência, no nível de 95% de confiança. As maiores vantagens da exploração do efeito Schlieren na análise química são que nenhum reagente é empregado, que utiliza baixo volume de amostras e que não emprega caros detectores de radiação.

Page generated in 0.181 seconds